installation instructions hp StorageWorks SAN switch rack mount kit Second Edition (June 2003) Part Number: AV-RU6YB-TE This document provides step-by-step instructions for installing the SAN Switch 2/8, SAN Switch 2/16 or SAN Switch 2/32 using the hp StorageWorks SAN switch rack mount kit. For the - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 2
this document is subject to change without notice. BROCADE, the Brocade B weave logo, Brocade: the Intelligent Platform for Networking Storage, SilkWorm, an additional warranty. Printed in the U.S.A. SAN Switch Rack Mount Kit Installation Instructions Second Edition (June 2003) Part Number: AV-RU6YB - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 3
SAN Switch 2/32, SAN Switch 2/16, and SAN Switch 2/8 in an HP Series 9000 or comparable EIA rack, or in an HP System/e rack using the SAN Switch Rack your switch. For the latest information, documentation, and firmware releases, please visit the following StorageWorks website: http://www.hp.com/ - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 4
coupled. ■ Only one rack component is extended at any time. A rack may become unstable if more than one rack component is extended for any reason. 4 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 5
SAN Switch in one of the following ways: ■ As a stand-alone unit on a flat surface. ■ In an Electronics Industries Association (EIA) cabinet (like the HP 9000 Series Rack). ■ In an HP switch. ■ If installing the switch in the HP into the switch chassis by HP logo. HP recommends installing the switch - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 6
supply circuit, line fusing, and wire size, as specified by the electrical rating on the switch nameplate ■ Voltage capability of 85-264 VAC ■ Input voltage frequency of 47-63 Hz secondary connection to a branch circuit, such as a power strip. 6 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 7
basis, particularly if the switch is installed in a closed or multi-rack assembly. ■ Verify that the additional weight of the switch does not exceed the cabinet movement. Note: For proper air flow, the SFP media side of the switch must face the rear of the rack. This mounting allows air to enter - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 8
the SAN Switch Rack Mount Kit This section provides instructions for installing the SAN Switch 2/32, SAN Switch 2/16, or SAN Switch 2/8 in an HP System/e rack, or in an HP 9000 Series or comparable EIA rack using the SAN Switch Rack Mount Kit, part number 331148-B21. Figure 1: SAN Switch 2/16 rack - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 9
16-inch Phillips pan-head screw with thread lock (10) #10-32 x 1/2-inch Phillips pan-head screw with captive star lock washer (8) #10 alignment washer (8) #10 adapter washer (2) 1/4-20 hex nut with captive star lock washer (2) 1/4-inch flat washer SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 10
of the two brackets with (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and (2) #10 adapter washers as shown in Figure 2. Figure 2: Installing the rear mounting brackets (HP 9000 Series or comparable EIA rack) 10 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 11
in Figure 3. Figure 3: Installing the rear mounting brackets (HP System/e rack-left rear upright) Note: This kit contains both left rails and right rails. The rails are marked with Right and Left to distinguish the rails from each other. SAN Switch Rack Mount Kit Installation Instructions 11 - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 12
star lock washers attached loosely as shown in Figure 4. Don't tighten them. The nuts will be tightened later in step 8. Figure 4: Installing the outer rails (HP 9000 Series or comparable EIA rack) 12 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 13
-32 x 1/2-inch Phillips pan-head screws with captive star lock washers and two #10 adapter washers in the upper and lower hole locations of the left rail. See Figure 5. Figure 5: Assembling the outer rails (HP 9000 Series or comparable EIA rack) SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 14
with thread lock required to assemble the inner rails by referring to Table 1. Table 1: Number of screws required to assemble the inner rails Switch SAN Switch 2/32 SAN Switch 2/16 SAN Switch 2/8 Number of #8-32 x 3/16-inch Screws 12 10 14 14 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 15
can cause damage to internal components. Note: The inner rails work for all three SAN switches-SAN Switch 2/32, SAN Switch 2/16, and SAN Switch 2/8. The mounting holes in the inner rails are marked with 32, 16, and 8. Use the appropriately labeled mounting holes when installing the inner rails on - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 16
screws. Attaching both inner rails requires ten screws. Figure 7: Assembling the inner rails Note: For factory integration only, tighten the #8-32 x 3/16-inch Phillips pan-head screw with thread lock and torque between 6 to 8 inch-pounds. 16 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 17
. If the plenum is not preinstalled on the SAN Switch 2/8, refer to the HP StorageWorks SAN Switch 2/8 Version 3.1.x Installation Guide for complete plenum installation instructions. Figure 8: Assembling the inner rails on a SAN Switch 2/8 with plenum SAN Switch Rack Mount Kit Installation - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 18
the switch into a rack (HP 9000 Series or comparable EIA rack) Insert the switch into the rack and install (2) #10-32 x 1/2-inch Phillips pan-head screws with captive star lock washers with one on each side. See Figure 9 and Figure 10. 18 SAN Switch Rack Mount Kit Installation Instructions - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 19
/e rack) 8. Tighten the nuts installed in step a of step 4 on page 12. See Figure 4. Note: To uninstall a switch, remove the middle #10-32 x 1/2-inch Phillips pan head screw with captive star lock washer from either side of the rack uprights. SAN Switch Rack Mount Kit Installation Instructions 19 - HP StorageWorks 8B | SAN switch rack mount kit installation instructions - Page 20
20 SAN Switch Rack Mount Kit Installation Instructions
installation
instructions
hp
StorageWorks
SAN switch
rack mount kit
Second Edition (June 2003)
Part Number:
AV–RU6YB–TE
This document provides step-by-step
instructions for installing the SAN Switch 2/8, SAN Switch
2/16 or SAN Switch 2/32 using the hp StorageWorks SAN switch rack mount kit.
For the latest version of these Installation Instructions and other documentation, access the HP
storage website at:
.