HP StorageWorks 8B Fabric OS Reference Manual (Version 3.0)
HP StorageWorks 8B - FC Entry Switch Manual
View all HP StorageWorks 8B manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 8B manual content summary:
- HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 1
reference manual version 3.0 fabric os www.hp.com - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 2
, duplication, or disclosure by government is subject to restrictions as set forth in subdivision (c) (1) (ii) of the Rights in Technical service names are or may be trademarks or service marks of, and are used to identify products of services of their respective owners. Safety notices Any servicing - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 3
Preface Chapter 1 Fabric OS Reference About This Guide xi Related Publications xi System Requirements and Compatibility xiii Getting Help xiii Getting Software Updates xiii Telnet Commands agtcfgDefault 1-1 agtcfgSet 1-3 agtcfgShow 1-5 aliasShow 1-7 aliAdd 1-8 aliCreate 1-9 aliDelete - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 4
cfgEnable 1-23 cfgRemove 1-24 cfgSave 1-25 cfgShow 1-26 cfgTransAbort 1-28 cmemRetentionTest 1-29 cmiTest 1-30 configDefault 1-32 configDownload 1-33 configShow 1-35 configUpload 1-37 configure 1-39 crossPortTest 1-47 date 1-51 diagClearError 1-52 diagDisablePost 1-53 diagEnablePost - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 5
fspfShow 1-75 fwAlarmsFilterSet 1-77 fwAlarmsFilterShow 1-78 fwClassInit 1-79 fwConfigure 1-80 fwConfigReload 1-83 fwHelp 1-84 fwMailCfg 1-85 fwSetToCustom 1-87 fwSetToDefault 1-88 fwShow 1-89 gbicShow 1-91 h 1-93 help 1-94 i 1-95 ifModeSet 1-97 ifModeShow 1-98 ifShow 1-99 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 6
licenseRemove 1-116 licenseShow 1-117 linkCost 1-118 login 1-119 logout 1-120 LSDbShow 1-121 mcastShow 1-124 msConfigure 1-125 msPlatShow 1-127 msPlClearDB 1-128 msPlCapabilityShow 1-129 msPlMgmtActivate 1-130 msPlMgmtDeactivate 1-131 msTDEnable 1-132 msTDDisable 1-133 nbrStatsClear - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 7
perfCfgSave 1-153 perfClrAlpaCrc 1-154 perfDelEEMonitor 1-155 perfHelp 1-156 perfDelFilterMonitor 1-157 perfSetPortEEMask 1-158 perfShowAlpaCrc 1-160 perfShowEEMonitor 1-161 perfShowFilterMonitor 1-163 perfShowPortEEMask 1-165 portCfgEport 1-167 portCfgGport 1-168 portCfgLport 1-169 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 8
psShow 1-202 qloopAdd 1-203 qloopCreate 1-204 qloopDelete 1-205 qloopRemove 1-206 qloopShow 1-207 qlDisable 1-209 qlEnable 1-210 qlPartner 1-211 qlPortDisable 1-212 qlPortEnable 1-213 qlPortShowAll 1-214 qlShow 1-215 qlStatsShow 1-217 quietMode 1-218 ramTest 1-219 reboot 1-221 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 9
statsTest 1-245 supportShow 1-246 switchBeacon 1-248 switchCfgSpeed 1-249 switchCfgTrunk 1-250 switchDisable 1-251 switchEnable 1-252 switchName 1-253 switchShow 1-254 switchStatusPolicySet 1-257 switchStatusPolicyShow 1-259 switchStatusShow 1-261 syslogdIpAdd 1-262 syslogdIpRemove 1- - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 10
Error Messages 3-19 Licensed Telnet Commands Zoning Commands 4-1 QuickLoop Commands 4-2 QuickLoop Fabric Assist Mode Commands 4-3 Extended Fabric Command 4-3 Fabric Watch Commands 4-4 FC 6164 Commands 4-4 Trunking Commands 4-5 Performance Monitoring Commands 4-5 x Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 11
the telnet commands used to administer and configure HP Brocade switches (HP Surestore FC 1Gb/2Gb Entry Switch 8B, HP Surestore FC 1Gb/2Gb Switch 8B, HP Surestore FC 1Gb/2Gb Switch 16B, HP Brocade 2400 and 2800 switches, and HP Surestore FC Switch 6164). About This Guide This guide provides the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 12
Web site at http://www.hp.com/support/fc8B: • HP Surestore FC 1Gb/2Gb Entry Switch 8B and FC 1Gb/2Gb Switch 8B Getting Started Guide (A7346-90902) • HP Surestore FC 1Gb/2Gb Entry Switch 8B and FC 1Gb/2Gb Switch 8B Installation and Reference Guide • Fabric OS Reference Manual, version 3.0 • Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 13
about configuring FC Entry Switch 8B, FC Switch 8B, FC 16B, HP Brocade 2400/2800, and FC 6164 products to operate in the same fabric, contact your switch supplier. Getting Help For information for the FC Entry Switch 8B and FC Switch 8B, visit the HP Web site at http://www.hp.com/support/fc8B - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 14
xiv Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 15
admin Description Use this command to reset the configuration of the SNMP agent to default values: • sysDescr - The default value is Fibre Channel Switch. • sysLocation - The default value is End User Premise. • sysContact - The default value is Field Support. • swEventTrapLevel - The default - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 16
1 Telnet Commands Example To set the SNMP agent configuration parameters to default values, and verify they were set: switch:admin> agtcfgDefault Committing configuration...done. agent configuration reset to factory default switch:admin> switch:admin> agtcfgShow Current SNMP Agent Configuration - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 17
configuration. Synopsis agtcfgSet Availability admin Description Use this command to modify the configuration of the SNMP agent in the switch. Set the values for the following items: • sysDescr - Specify the switch each with a respective trap recipient, supported by the agent. The first three - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 18
the previous character, erases the whole line, sysDescr: [FC Switch] sysLocation: [End User Premise] sysContact: [Field Support] swEventTrapLevel: (0..5) [3] 4 authTrapsEnabled (true, t, false, f): [true] SNMP community and trap recipient configuration: Community (rw): [Secret C0de] Trap - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 19
command to display the configuration of the SNMP agent in the switch. The following information is displayed: • sysDescr - Displays the switch description. • sysLocation - Displays the location of the switch , each with a respective trap recipient, supported by the agent. The first three communities - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 20
1 Telnet Commands Example To display SNMP agent configuration information: switch:admin> agtcfgShow Current SNMP Agent Configuration Customizable MIB-II system variables: sysDescr = FC Switch sysLocation = End User Premise sysContact = Field Support. swEventTrapLevel = 3 authTraps = 1 (ON) SNMPv1 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 21
member address IDs. Operands None. Example To display the entries in the local alias server: switch:admin> aliasShow The Local Alias Server has 1 entry Alias ID Creator Token [rb, type, grptype, qlfr] Member List fffb01 fffffd [40, 05, 10, 60000010 12000069] {021200 0208e2} See Also fabricShow - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 22
alias. The alias member list cannot contain another zone alias. Operands This command has the following operands: aliName Specify the name of a zone alias the following aliases: switch:admin> aliAdd "array2", "1,2" switch:admin> aliAdd "array1", "21:00:00:20:37:0c:72:51" switch:admin> aliAdd " - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 23
allowed). The alias member list cannot contain another zone alias. Operands This command has the following operands: aliName Specify a name for the zone alias worldwide names: switch:admin> aliCreate "array1", "3,5; 3,8" switch:admin> aliCreate "array2", "21:00:00:20:37:0c:66:23" switch:admin> - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 24
the change to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to flash memory using the cfgSave command. Operands This command has the following operands: aliName Specify the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 25
are removed, the zone alias is deleted. This command changes the Defined Configuration. For the change to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be saved to flash memory using - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 26
zone alias names; those that match in the defined configuration are displayed. Operands This command has the following operands: pattern A POSIX style regular beginning with "arr": switch:admin> aliShow "arr*" alias: array1 21:00:00:20:37:0c:76:8c alias: array2 21:00:00:20:37:0c:66:23 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 27
optional. Specify the command with no operand to display the current setting. Example To display the current backspace character and change it to DEL: switch:admin> backSpace BackSpace character is BACKSPACE (hex 08) switch:admin> backSpace 1 Committing configuration...done. BackSpace character - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 28
the ports is displayed as a set of hexadecimal bit maps. For more information on reading hexadecimal bit maps, refer to the Fabric OS User's Guide. Operands None. Examples To display the broadcast routing information for all ports in the switch: switch:admin> bcastShow Group Member Ports Member - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 29
correct. The CAM is used by QuickLoop to translate the SID. Note: This command may not be executed on an enabled switch. You must first disable the switch using the switchDisable command. Operands This command has the following operand: passCount Specify the number of times to execute this test - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 30
and data bus of the ASIC SRAMs that serve as central memory. Note: This command may not be executed on an enabled switch. You must first disable the switch using the switchDisable command. Operands This command has the following operands: passCount Specify the number of times to execute this test - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 31
See Also ramTest portRegTest cmiTest sramRetentionTest turboRamTest camTest statsTest filterTest portLoopbackTest spinSilk 1 Telnet Commands Fabric OS Reference 1-17 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 32
Note: This command requires a Zoning License. Operands This command has the following operands: cfgName Specify a name for the zone configuration in quotation marks required. Example To add two new zones to the configuration "Test_cfg": switch:admin> cfgAdd "Test_cfg", "zone2; zone3; loop1" - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 33
with the same name. After clearing the transaction buffer using the cfgClear command, use the cfgDisable command to commit the transaction, and clear the zone configuration in flash for all the switches. Note: This command requires a Zoning License. Operands None. Example To clear all zones, then - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 34
this command to create a new zone configuration. A zone configuration name command requires a Zoning License. Operands This command has the following operands: cfgName Specify a name for the zone configuration To create a configuration containing three zones: switch:admin> cfgCreate "Test_cfg - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 35
admin Description Use this command to delete a zone configuration. This command changes the Defined Configuration. For the change to become effective, an appropriate zone configuration must be enabled using the cfgEnable command. For the change to be preserved across switch reboots, it must be - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 36
After clearing the transaction buffer using the cfgClear command, use the cfgDisable command to commit the transaction, and clear the zone configuration in flash for all the switches. If a transaction is open on a different switch in the fabric when this command is run, the transaction on the other - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 37
zone configuration. This command ends the current zoning transaction. The specified zone configuration is built by checking for undefined zone names, zone alias names, or other inconsistencies; by expanding zone aliases, removing duplicate entries, and then installing the effective configuration. If - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 38
command to remove a member from an existing zone configuration members. For example, if a zone configuration contains "cfg2; cfg3; cfg4" then removing removed, the zone configuration is deleted. Note: This command requires a Zoning zone from a configuration: switch:admin> cfgRemove "Test_cfg - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 39
Availability admin Description Use this command to save the current zone configuration. The defined configuration and the name of the enabled configuration are written to flash memory in all switches in the fabric. The saved configuration is automatically reloaded by the switch on power up and, if - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 40
is displayed. If an operand is specified, it is used as a pattern to match zone configuration names in the defined configuration; those that match the pattern are displayed. The defined configuration is the complete set of all zone objects that have been defined in the fabric. There can be multiple - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 41
Commands To show all configuration information: switch:admin> cfgShow Defined configuration: cfg: USA1 cfg: USA_cfg zone: Blue_zone zone: Red_zone alias: array1 alias: array2 alias: loop1 Blue_zone Red_zone; Blue_zone 1,1; array1; 1,2; array2 1,0; loop1 21:00:00:20:37:0c:76:8c; 21:00:00:20 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 42
was started will be removed and the zone configuration database restored to the state before the transaction was started. Note: This command requires a Zoning License. Operands None. Example To abort the current transaction: switch:admin> cfgTransAbort See Also cfgSave cfgDisable cfgEnable - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 43
verify data retention in the central memory SRAMs in the ASIC. Note: This command may not be executed on an enabled switch. You must first disable the switch using the switchDisable command. Operands This command has the following operand: passCount Specify the number of times to execute this test - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 44
destination quad and that a message with a good checksum does not set an error or interrupt bit in any ASIC. Note: This command may not be executed on an enabled switch. You must first disable the switch using the switchDisable command. The Test method is displayed below. Complete the following for - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 45
DIAG-CMINOCAP DIAG-CMICKSUM DIAG-CMIINVCAP DIAG-CMIDATA DIAG-INTNIL DIAG-BADINT See Also ramTest portRegTest centralMemoryTest sramRetentionTest turboRamTest camTest statsTest filterTest portLoopbackTest spinSilk 1 Telnet Commands Fabric OS Reference 1-31 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 46
Note: Refer to the configure command for more information on default values for configuration parameters. Note: This command may not be executed on an enabled switch. You must first disable the switch using the switchDisable command. Some configuration parameters are cached by the system - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 47
of the password operand selects FTP. A switch's identity cannot be changed by configDownload. These parameters (such as the switch's name and IP address) are ignored. The download process is additive; that is, the lines read from the file are added to the current switch configuration. This enables - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 48
:admin> configDownload "citadel","jdoe","config.txt" Committing configuration...done. download complete Errors See Also Listed below are possible reasons for a failure of this command: • The host name is not known to the switch • The host IP address cannot be contacted • The user does not have - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 49
marks that limits the output of the command to only those entries that contain the text string. The filter does not apply to the ethernet MAC address and NVRAM data display settings. Example To display system configuration settings: switch:admin> configShow Ethernet address: 0:60:69:0:60 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 50
1 Telnet Commands See Also agtcfgShow configure diagDisablePost diagEnablePost ipAddrShow licenseShow syslogdIp 1-36 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 51
Use this command to upload the switch configuration to a host file. The upload process uses either FTP or the RSHD protocol (TPC service 514). Both of these services are widely available on UNIX hosts, but less so on WIndows hosts. On Windows NT, the FTP server may have to be installed from the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 52
]: user21 File Name [config.txt]: config-switch.txt Protocol (RSHD or FTP) [FTP]: ftp Password: xxxxxx upload complete switch:admin> Errors See Also Listed below are possible reasons for a failure of this command: • The host name is not known to the switch • The host IP address cannot be contacted - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 53
configuration settings: • Fabric parameters • Virtual channel settings • Switch Operating Mode • Zoning Operation parameters • RSCN Transmission Mode • NS Pre-zoning Mode • Arbitrated Loop parameters • System services • Portlog events enable Note: Do not run this command on an operational switch - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 54
: Table 1-1 Configure Command Fabric parameters Field Default Domain 1 BB Credit 16 R_A_TOV 10000 E_D_TOV 2000 Data Field Size 2112 Sequence Level Switching 0 Disable Device Probing 0 Suppress Class F Traffic 0 SYNC IO mode 0 VC Encoded Address Mode 0 Core Switch PID Format - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 55
1 Telnet Commands Data Field Size The data field size specifies the largest possible value, in bytes, and advertises this value to other switches in the fabric during construction of the fabric as well as to other devices when they connect to the fabric. Setting this to a value smaller than 2112 may - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 56
default values can improve switch performance, but can also degrade performance. Do not change these settings without fully understanding the effects of the changes. The Virtual Channel Setting fields are as follows: Table 1-2 Configure Command Virtual Channel Settings Field Default Range VC - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 57
Pre-zoned responses Mode Specify 0 for Standard Mode, or 1 for Pre-zoning On. Arbitrated Loop Settings The Arbitrated Loop Setting fields are as follows: Table 1-3 Configure Command Arbitrated Loop Settings Field Default Send FAN frames? 1 Always send RSCN? 0 Enable CLOSE on OPEN received - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 58
1 Telnet Commands System Services The System Services fields are as follows: Table 1-4 Configure Command System Services Parameters Field Default rstatd Off rusersd Off rapid On Disable RLS probing On Range On/Off On/Off On/Off On/Off Descriptions of the system service setting fields - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 59
Enable Use these parameters to specify which events create an entry in the port log. The Portlog Events fields are as follows: Table 1-5 Configure Command Portlog Events parameters Field (Valid Values) Default Value start: a switch start or re-start event (on, off): [on] disable: a port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 60
1 Telnet Commands Example To set the configuration parameters for a switch: switch:admin> configure Configure... Fabric parameters (yes, y, no, n): [no] yes Domain: (1..239) [1] BB credit: (1..27) [16] R_A_TOV: (4000..120000) [10000] E_D_TOV: (1000..5000) [2000] 5000 Data field size: (256..2112) [ - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 61
through an external fiber cable into another port receiver. This command exercises all of the switch components from the main board to the GBIC, from the testing, ports connected should be from different ASICs. For example, in the FC 16B, ports 0-3 are assigned to ASIC 0, ports 4-7 are assigned to - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 62
a test loop between two ports on a single ASIC. GBIC (SFP) Mode Use the setGbicMode command to activate GBIC mode by executing the following command prior to executing the crossPortTest command: switch:admin> setGbicMode 1 When activated, only ports with SFPs present are tested by the crossPortTest - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 63
state of GBIC mode is saved in flash memory and remains active after reboots or power cycles until it is disabled as follows: switch:admin> setGbicMode 0 This command has the following operands: passCount Specify the number of times (or number of frames per port) to execute this test. This number - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 64
1 Telnet Commands Example To execute a functional test of all the ports on a switch 100 times: switch:admin> crossPortTest 100, 1 Running Cross Port Test ....... One moment please ... switchName: switch switchType: 2.2 switchState: Testing switchRole: Disabled switchDomain: 1 ( - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 65
set the switch date and time. Synopsis date ["newDate"] Availability All users (display) admin (set) Description Use this command with no operands to display date and time. Use the newdate operand to set not support daylight saving time or time zones. All switches maintain current date and - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 66
settings are displayed by using the diagShow command. This command resets the flag to allow the bad port to be retested; otherwise the test skips the port. This command does not clear the error log entry Valid values for port number vary depending on the switch type. This operand is optional. If no - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 67
command. A switch rebooted without POST enabled issues the following DIAG-POSTSKIPPED error message: 0x10fc0c10 (tSwitch): Apr 6 13:24:42 test. • filterTest - Functional test of filter configuration. • portLoopbackTest - Functional test of switch by sending and receiving frames from the same port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 68
using the diagDisablePost command. POST includes the following tests: • ramTest - Bit write and read test of SDRAMS in the switch. • portRegTest - . • filterTest - Functional test of filter configuration. • portLoopbackTest - Functional test of switch by sending and receiving frames from the same - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 69
command to display diagnostic command information. Operands None. Example To display information about diagnostic commands: switch Test Central Mem Data Retention diagnostic Cross-connected port diagnostic Cross-connected line-speed exerciser Clear diag error on specified port Disable Power-On-Self - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 70
the last boot. Synopsis diagShow [nSeconds] Availability All users Description Use this command to print the following information generated since the last switch reboot: • State of all ports in the switch resulting from diagnostics run since the last reboot. Ports that passed diagnostic testing - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 71
1 Telnet Commands Example To print the diagnostic results since the last boot. switch:admin> diagShow Diagnostics Status: Wed Apr 5 03:09:20 2000 port#: 0 1 2 3 4 5 6 7 diags: OK OK OK OK OK OK OK OK state: UP UP UP UP UP UP UP UP speed: 1G 1G 1G 1G - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 72
1 second. Use this command only if devices connected to the fabric cannot handle occasional routing changes. Operands None. Examples To disable the dynamic load sharing option. switch:admin> dlsReset Committing configuration...done. switch:admin> dlsShow DLS is not set See Also dlsSet dlsShow - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 73
iodSet command), routes are not available for a few seconds after a fabric change. The time needed to reset the fabric routing varies based on the size of dynamic load sharing option. switch:admin> dlsSet Committing configuration...done. switch:admin> dlsShow DLS is set See Also dlsReset dlsShow - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 74
of the Dynamic Load Sharing (DLS) option. Synopsis dlsShow Availability All users Description Use this command to display whether DLS is on or off. There can be two messages displayed: DLS is set The DLS option is turned on. Load sharing is reconfigured with every change in the fabric. DLS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 75
Availability All users (display) admin (set) Description Use this command to view or configure the error levels that are displayed on on the front panel. Note: This command can only be used on a switch with a front panel display. Operands This command has the following operand: level Specify - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 76
page breaks. This command displays the same information as errShow, but errShow enables you to scroll through the entries using the Enter button. See errShow for a description of the error log. Operands None. Example To display the error log without page breaks: switch:admin> errDump Error - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 77
is 999. Error Type An upper case string showing the firmware module and error type. The switch manual contains a detailed explanation of error types. Error Level 0 = panic (the switch reboots) 1 = critical 2 = error 3 = warning 4 = information 5 = debug Error Message Additional information - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 78
1 Telnet Commands Diagnostic Error Codes The following table lists the error code numbers, the POST test that generates this error number, and the type of error. Table 1-6 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 79
1 Telnet Commands Table 1-6 Diagnostic Error Codes (Continued) Error Number Test 1F27 2030 2031 2032 2033 cmemRetentionTest cmiTest cmiTest cmiTest cmiTest 2034 cmiTest 2035 cmiTest 2036 223B 223C - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 80
1 Telnet Commands Table 1-6 Diagnostic Error Codes (Continued) Error Number Test 3045 3046 3047 304F 305F crossPortTest crossPortTest crossPortTest crossPortTest crossPortTest 3060 crossPortTest 3061 crossPortTest 3062 306E 306F - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 81
1 Telnet Commands Example The following illustrates two entries in the error log: switch:admin> errShow Error 02 -------0x10fbd880 (tSwitch): Feb 5 17:03:19 Error DIAG-POST_SKIPPED, 3, Skipped POST tests: assuming all ports are healthy, Err# 0004 Type - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 82
Description Use this command to display information about switches and multicast switches. "sw180" is the principal switch. Three of the switches are configured to run IP over Fibre Channel. There is one multicast alias group. switch:admin> fabricShow Switch ID Worldwide Name Enet IP Addr FC - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 83
Display fan status. Synopsis fanShow Availability All users Description Use this command to display the current status of the switch fans.The format of the display varies according to the switch model and number of fans. Some switch models show fan speed measured in RPM (revolutions per minute - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 84
, bypassing POST. Synopsis fastboot Availability admin Description Use this command to reboot the switch, bypassing Power On Self Test (POST). The reboot takes effect immediately as the switch resets and executes normal power-on booting sequence. However, POST is skipped. This reduces boot time - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 85
9 Zone A&B match and ALPA match List B 10 Zone A|B match and ALPA match Frozen 11 Zone A|B match and ALPA match Discard Operands This command has the following operand: passcount Specify the number of times to execute this test. The default value is 1. This operand is optional. Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 86
1 Telnet Commands Example To run the filterTest: switch:admin> filterTest Running Filter Test passed. See Also ramTest portRegTest cmiTest centralMemoryTest sramRetentionTest turboRamTest camTest statsTest portLoopbackTest spinSilk 1-72 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 87
admin Description Use this command to download a switch firmware file from a host into the switch flash memory. The download process uses either FTP (File Transfer Protocol) or the RSHD protocol (TCP service 514). On Windows NT, the FTP server may have to be installed from the distribution media - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 88
1 Telnet Commands Example To download a firmware file: switch:admin> firmwareDownload "citadel","jdoe","/home/firmware/v2.2" 55696+6984+133172, csum 7eca writing flash 0 writing flash 1 download complete Errors See Also The following can cause the download to fail: • The host - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 89
protocol information. Synopsis fspfShow Availability All users Description Use this command to display the Fibre Channel Shortest Path First (FSPF) domainID: isl_ports: Version of FSPF protocol. Domain number of local switch. Bit map of all E_Ports. minLSArrival: FSPF constant. minLSInterval - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 90
1 Telnet Commands Examples To display FSPF protocol information: switch:admin> fspfshow version = 2 domainID = 3 isl_ports = 0x00000020 minLSArrival = 3 minLSInterval = 5 LSoriginCount = 0 startTime = 16784 fspfQ = 0x10f48f10 fabP = 0x10f49f90 agingTID = 0x10f3c100 agingTo = - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 91
This command has the following operand: 0 | 1 Specify 1 for enabling the alarms, 0 for disabling the alarms. The default value is 0 (alarms are deactivated). This operand is optional. Example To enable alarms in Fabric Watch: switch:admin> fwAlarmsFilterSet Committing configuration...done - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 92
alarm filtering is enabled or disabled. Note: This command requires a Fabric Watch License. Operands none Example To display the status of alarm filtering in Fabric Watch: switch:admin> fwAlarmsFilterShow FW: Alarms are enabled switch:admin> fwAlarmsFilterShow FW: Alarms are disabled See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 93
to initialize all classes under Fabric Watch. Note: This command requires a Fabric Watch License. Operands None Example To initialize all classes under Fabric Watch: switch:admin> fwClassInit gbicRegister: re-register 0x0 0x10f6c260 fwClassInit: Fabric Watch initialized See Also fwConfigReload - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 94
Watch configuration and status. Synopsis fwConfigure Availability admin Description Use this command to display and modify threshold information for the Fabric Watch configuration. Switch word Invalid CRC count Receive performance Transmit performance State changes 1-80 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 95
1 Telnet Commands Table 1-9 fwConfigure Fabric Watch classes and areas (Continued) Class Area E_Port Link failure count Loss of synchronization count Loss of signal count Primitive sequence protocol - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 96
1 Telnet Commands Example To display the Fabric Watch configuration and status: switch:admin> fwConfigure 1 : Environment class 2 : GBIC class 3 : Port class 4 : Fabric class 5 : E-Port class 6 : F/FL Port (Copper) class 7 : F/FL Port (Optical) class 8 : quit Select a class => : (1..8) [8] 1 1 : - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 97
Use this command to reload the Fabric Watch configuration. This command should only be used after downloading a new Fabric Watch configuration file from a host. Note: This command requires a Fabric Watch License. Operands None Example To reload the saved Fabric Watch configuration: switch:admin - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 98
commands: switch:admin> fwHelp fwAlarmsFilterSet fwAlarmsFilterShow fwClassInit fwConfigure fwConfigReload fwSetToCustom fwSetToDefault fwShow fwMailCfg switch:admin> Configure Watch classes Configure Fabric Watch Reload Fabric Watch configuration Set boundary & alarm level to custom Set boundary & - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 99
command is executed a menu of configuration tasks are displayed. Select the configuration task by entering a value 1 through 6: 1 : Show Mail Configuration Information 2 : Disable EmailAlert 3 : Enable EmailAlert 4 : Send Test Mail 5 : Set , [email protected]. Operands None. Fabric OS Reference 1-85 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 100
1 Telnet Commands Example To configure an email address recipient in Fabric Watch: switch:admin> fwMailCfg 1 : Show Mail Configuration Information 2 : Disable EmailAlert 3 : Enable EmailAlert 4 : Send Test Mail 5 : Set Mail Address for EmailAlert 6 : quit Select an item => : (1..6) [6] 5 Mail Config - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 101
and alarm levels to custom for all classes and areas for Fabric Watch. Note: This command requires a Fabric Watch License. Operands none Example To set alarm levels to custom values: switch:admin> fwSetToCustom Committing configuration...done. See Also fwSetToDefault Fabric OS Reference 1-87 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 102
alarm levels to default for all classes and areas for Fabric Watch. Note: This command requires a Fabric Watch License. Operands none. Example To set alarm levels to default values: switch:admin> fwSetToDefault Committing configuration...done. See Also fwSetToCustom 1-88 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 103
threshold is displayed and printed. Note: This command requires a Fabric Watch License. Operands This command has the following operand: pattern Specify a POSIX style regular expression enclosed in quotation marks and used to match zone configuration names. Patterns can contain: • Question mark - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 104
1 Telnet Commands Example To display the thresholds monitored by Fabric Watch: switch:admin> fwShow Name Label Last :50:21 on 02/01/2000 Lower bound: 0 C Upper bound: 75 C Buffer Size: 10 Value history: 33 C Disabled? No Locked? No See Also fwClassInit fwConfigReload fwConfigure - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 105
GBICs provide extended information that describes the GBICs capabilities, interfaces, manufacturer, and other information. Use this command with no operand to display a summary of all GBICs in the switch. The summary shows the GBIC type (see switchShow for an explanation of the two letter codes) and - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 106
No: 103960 port 3: sw port 4: sw port 5: cu port 6: sw port 7: sw switch:admin> switch:admin> gbicShow 2 Identifier: 1 GBIC Connector: 1 SC Transceiver: 010d102202000000 100_MB/s SM M5 M6 Longwave Inter_dist Encoding: 1 8B10B Baud Rate: 12 (units 100 megabaud) Length 9u: 100 (units 100 meters - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 107
be edited. The command h displays the 20 most recent commands typed into the shell; old commands fall off the top as new ones are entered. To edit a command, press ESC to access edit mode, then use vi commands. The ESC key switches the shell to edit mode. The RETURN key gives the line to the shell - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 108
operand is optional. Example The first example provides help information on the login command. The second example provides help information on the configure command. switch:admin> help login ... switch:admin> help "configure" ... See Also diagHelp licenseHelp routeHelp 1-94 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 109
All users Description Use this command to display a synopsis of all tasks in the switch, or for a specific task if a taskID is supplied. One line is displayed for each task; it contains the following fields: Table 1-10 Field Description Field Description NAME ENTRY TID PRI STATUS PC SP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 110
1 Telnet Commands Example To display the task summary: switch:admin> i tFabric NAME ENTRY TID PRI STATUS PC SP ERRNO DELAY tFabric _fabricTask 103aae20 100 PEND 10191b78 103ab1e0 0 0 switch:admin> i NAME ENTRY TID PRI STATUS PC SP ERRNO DELAY tExcTask _excTask 103f7eb0 0 PEND - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 111
command to set command is only functional for "fei" interfaces. Exercise care when using this command. Forcing the link to an operating mode not supported Mbps / Half duplex operation: switch:admin> ifModeSet "fei0" Auto- configuration...done. See Also ifModeShow ifShow Fabric OS Reference 1-97 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 112
. Operands This command has the following operand: interface Specify the name of the interface in quotation marks. For example, "fei0", where fei is the network interface and 0 is the physical unit. Example To display the link operating mode for the "fei0" ethernet interface: switch:admin - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 113
"fc" is the Fibre Channel interface The "fc" interface is displayed for switches running IP over Fibre Channel that have been assigned an FC-IP • Number of input errors, output errors, and collisions Operands This command has the following operand: ifName Specify the name of an interface, - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 114
• the neighbor data structure. This data structure is allocated when a switch port becomes an E_Port. The neighbor data structure contains all the information relating to the switch that is connected to an adjacent switch. This command displays the content of both data structures, if they have been - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 115
includes Hellos, Link State Updates (LSU) and Link State Acknowledgements. nInvCmd Number of invalid commands received from the neighbor switch. Usually commands with an FSPF version number higher than the one running on the local switch. nHloIn Number of Hello frames received from the neighbor - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 116
1 Telnet Commands Operands Examples This command has the following operand: port Specify the port number to display the interface data structures for. Valid values for port number vary depending on the switch type. This operand is required. To display FSPF interface information: switch:admin> - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 117
Tools, Fabric Watch, and SES are available for the switches, plus basic Zoning and QuickLoop functionality for all switches. Interoperability is supported only for HP Brocade 2400/2800 and FC 6164 switches running Fabric OS version a2.4.1 or later; and FC Entry Switch 8B, FC Switch 8B, and FC 16B - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 118
the vendor establishes a "Defined Configuration". • Zoning is available for port WWN only. Node WWN members and members added by AL_PA Port ID are ignored. • Broadcast zones cannot be specified. • For end-ports in McData switches, only Name Server zoning is valid. • Support for Platform Management - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 119
Use this command to allows out of order delivery of frames during fabric topology changes. This is the default behavior, and allows fast rerouting after a fabric topology change. Operands None. Examples To turn off the IOD option: switch:admin> iodReset Committing configuration...done. See - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 120
there are devices connected to the fabric that do not tolerate occasional out of order delivery of frames, should this command be used. Operands None. Examples To turn on the IOD option: switch:admin> iodSet Committing configuration...done. See Also iodReset iodShow 1-106 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 121
Delivery (IOD) option. Synopsis iodShow Availability All users Description Use this command to display whether the IOD option is on or off. Operands None. Example To display the current setting of the IOD option: switch:admin> iodShow IOD is set See Also iodSet iodReset Fabric OS Reference 1-107 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 122
command to set the ethernet and FC switch:admin> ipAddrSet Ethernet IP Address [192.168.1.65]: Ethernet Subnetmask [none]: Fibre Channel IP Address [none]: 192.168.65.65 Fibre Channel Subnetmask [none]: Gateway Address [192.168.1.1]: Committing configuration...done. Set IP addresses now? [y = set - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 123
Display ethernet and FC IP addresses. Synopsis ipAddrShow Availability All users Description Use this command to display ethernet none if the switch is not configured to run IP over Fibre Channel. Operands None. Example To display the switch IP addresses: switch:admin> ipAddrShow Ethernet - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 124
Description Use this command to display the current connections and status of the ISL of each port on this switch. The following ISL is trunked Operands None. Example To show ISL link information on a switch: switch:admin> islShow 1: 3 -> 5 10:00:00:60:69:20:3a:a5 2: 6 -> 11 10:00:00:60:69:04:11 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 125
command is used for the FC 6164 only. Operands None. Example The following example displays islTopoCheck on a misconfigured FC 6164 switch. In a proper configuration, all of the switches name 01 01 10:00:00:60:69:20:02:9f jr_1003 02 02 10:00:00:60:69:10:a0:4e switch 03 -01 00:00:00:00:00:00 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 126
switch is a member. Note: This command is used for the FC 6164 only. Example The following example shows the results of islTopoShow on a misconfigured FC 6164 switch. In a proper configuration, all of the switches 10:00:00:60:69:20:02:9f jr_1003 02 02 10:00:00:60:69:10:a0:4e switch 03 -01 00:00 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 127
1 Telnet Commands Switch idx: 1 Domain: 1, wwn: 10:00:00:60:69:20:02:9f isl port expected switch port 0 00 -> es_6 : 08 1 01 -> es_6 : 09 2 02 -> -> -UNKNOWN- : 10 15 15 -> -UNKNOWN- : 11 actual switch es_6 es_6 -UNKNOWNes_6 -UNKNOWN-UNKNOWN-UNKNOWNes_6 -UNKNOWN-UNKNOWN- -UNKNOWN-UNKNOWN- - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 128
. Once the key has been installed, the product is immediately available. Operands This command has the following operand: license Specify a license key in quotation marks. This operand is required. Example To add a license key to the switch: switch:admin> licenseAdd "bQebzbRdScRfc0iK" adding - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 129
to administer license keys. Operands None. Example To display license commands: switch:admin> licenseHelp licenseAdd Add a license key to this switch licenseRemove Remove a license key from this switch licenseShow Show current license key See Also licenseAdd licenseRemove licenseShow Fabric - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 130
the key has been entered, use the licenseShow command to check that the key has been removed and the licensed product uninstalled. Once the license key has been removed, the switch must be rebooted. With no license keys installed, licenseShow displays "No licenses". Operands The following operand - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 131
licenseShow Availability All users Description Use this command to display current license keys along with a list of licensed products enabled by these keys; none is displayed if no license keys are installed. Operands None. Example In this example, the switch has two keys, the first key enables - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 132
linkCost [port], [cost] Availability admin Description Use this command to set or display the cost of an Inter-Switch Link (ISL). The cost of a link is a the cost: switch:admin> linkCost 1 Interface: 1 cost 1000 switch:admin> linkCost 1, 2000 Committing configuration...done. switch:admin> - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 133
login Login as a new user. Synopsis login Availability All users Description Use this command to login to the switch with another user name and password, without first logging out from the original session. If the user was originally connected using a telnet or rlogin session, that session - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 134
, the serial port returns to the "login:" prompt. The commands exit and quit are accepted as synonyms for logout, as is control-D entered at the beginning of a line. Operands None. Example To log out from a rlogin session: switch:admin> logout Connection closed. See Also login 1-120 Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 135
command to display a link state database record for switches in the fabric. There are two data structures - the permanently allocated Link State Database Entry apart. Last time an LSR was ignored. Time this LSR was installed in the database, in seconds since boot. Internal variable. Internal - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 136
the link. out port Port number on the local switch. rem port cost costCnt type Port number of the port on the other side of the link. Cost of this link. The default cost for a 1 Gb/s link is 1000. Always 0. Always 1. Operands This command has the following operand: domain Specify the domain - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 137
Commands Examples To display the Link State Record for the local switch, as indicated by self keyword (the local switch has four links in NB_ST_FULL state, three of them connected to switch 5, and one connected to switch 4. switch:admin> lsdbshow Domain = 7 (self), Link State Database Entry - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 138
command to display the multicast routing information, as it is known by the FSPF path selection and routing task, for all ports in the switch a multicast group contains any members. The multicast routing information is shown as a set of bit maps. Each bit in the bit map represents a port, with the least - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 139
Availability admin Description Use this command to display and configure parameters used to access the Management Server. The Management Server allows a storage area network (SAN) management application to retrieve and administer fabric and interconnect elements such as switches. It is located at - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 140
1 Telnet Commands Example To display the Management Server access control list. switch:admin> msConfigure 0 Done 1 Display the access list 2 Add member based on its Port/Node WWN 3 Delete member based on its Port/Node WWN select : (0..3) [1] MS Access List consists of (5): { 20:01:00:60 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 141
firmware v2.3 and above. Lower level firmware releases do not support Platform Database Management. Operands None. Example To display the Management Server platform database for a fabric: switch Names: 10:00:00:60:69:20:15:79 10:00:00:60:69:20:15:75 See Also msPlCapabilityShow msPlMgmtActivate - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 142
is available in v2.3 and above. Lower level firmware releases will not be able to support Platform Database Management. Operands None. Example To clear the Management Server platform database on all switches in the fabric: switch:admin> msPlClearDB Fabric-wise Platform DB Delete operation in - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 143
Management is available in firmware v2.3 and above. Lower level firmware releases do not support Platform Database Management. Operands None. Example To display Platform Database Management capability on a fabric: switch:admin> msPlCapabilityShow Platform Switch WWN Service Capable 10:00 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 144
of each switch, so even after a reboot, a switch will boot up with Platform Management service ENABLED. By default, the Platform Management service is DISABLED. Platform Database Management is available in firmware v2.3 and above. Lower level firmware releases do not support Platform Database - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 145
in the event of a reboot, the switch will initialize with the service DISABLED. By default, the Platform Management service is DISABLED. Platform Database Management is available in firmware v2.3 and above. Lower level firmware releases do not support Platform Database Management. Operands None - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 146
will be boot up with the Management Server Topology Discovery Management Service enabled. Topology Discovery Management requires the attached devices which include attached switches to support the RNID ELS command. Operands This command has the following operand: ALL Specify ALL to enable the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 147
capital letters. This operand is optional. Example To disable the Management Server Topology Discovery service locally or fabric-wide: switch:admin> msTdDisable This will erase all NID entries. Are you sure? Committing configuration...done. switch:admin> msTdDisable "ALL" This will erase all NID - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 148
no operand to reset counters on all interfaces. Operands This command has the following operand: port Specify the port number for the counters to be reset. Valid values for port number vary depending on the switch type. This operand is optional. Examples To display how to reset the counters - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 149
State of the neighbor. The E_Port is used to route frames only if the neighbor is in NB_ST_FULL state. Operands This command has the following operand: port Specify the port on the local switch that connects to the neighbor being displayed. Valid values for port number vary depending on the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 150
command to display the 24-bit Fibre Channel addresses of all devices in all switches in the fabric. If the operand type is supplied, only devices of specified FC FC-PH device type codes: 8 = FCP type device 4 , 5 = FC-IP type device Other FC-PH types are displayed in the format "x ports supporting - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 151
fabric. The command nsAllShow displays information from all switches. Each line of output shows: * Indicates a cached entry from another switch. Type U for unknown, N for N_Port, NL for NL_Port. PID 24-bit Fibre Channel address. COS List of classes of service supported by device. PortName - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 152
1 Telnet Commands Example To display local name server information: switch:admin> nsShow The Local Name Server has 7 entries { Type Pid COS PortName NodeName TTL(sec) 3;10:00:00:60:69:00:02:d6;20:00:00:60:69:00:02:d6; na NL 0214e2; 3;21:00:00:fa:ce:00:21:1e;20:00:00:fa:ce:00:21:1e; na - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 153
mode becomes active as soon as this command is executed. It does not require a switch:admin> parityCheck 1 Committing configuration...done. Parity check is now ON. switch:admin> parityCheck 0 Committing configuration...done. Parity check is now OFF. switch:admin> parityCheck 0 Parity not supported - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 154
are to be changed. This operand is optional. Example To change the admin user name and password: switch:admin> passwd "admin" New username [admin]: maint Old password: ******** New password: ******** Re-enter new password: ******** Committing configuration...done. 1-140 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 155
error messages are preceded by the command name with one of the following messages appended: "user" is not a valid user name. Permission denied. That user name is already being used. Incorrect password. Password unchanged. Number of failure attempts exceeded. Passwords do not match; try again. You - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 156
following two conditions. • for frames received at the port (with End-to-End monitor installed) the frame SID is the same as "SourceID" and frame DID is the same frames transmitted from port. After a successful execution of this command, a monitor number is displayed. The monitor number is provided - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 157
1 Telnet Commands Example To add an end-to-end monitor to port 2: switch:admin> perfAddEEMonitor 2, "0x058e0f", "0x1182ef" End-to-End monitor number 0 added. switch:admin> See Also perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor perfAddWriteMonitor - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 158
can be displayed with the perfShowFilterMonitor command. There is no need to define multiple IP frame monitors on a port. Operands This command has the following operands: port Specify monitor to port 2: switch:admin> perfAddIPMonitor 2 IP traffic frame monitor #0 added switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 159
All valid monitor numbers and user-defined aliases can be retrieved with the perfShowFilterMonitor command. The maximum number of filters is 8 per port including user-defined filters, monitor to port 2: switch:admin> perfAddReadMonitor 2 SCSI Read filter monitor #2 added switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 160
All valid monitor numbers and user-defined aliases can be retrieved with the perfShowFilterMonitor command. The maximum number of filters is 8 per port including user-defined filters, monitor to port 2: switch:admin> perfAddRWMonitor 2 SCSI Read/Write monitor #1 is added switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 161
to count the number of SCSI traffic frames. After a successful execution of this command, a monitor number is displayed. The monitor number is provided for easy manipulation of monitor to port 2: switch:admin> perfAddSCSIMonitor 2 SCSI traffic frame monitor #0 added switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 162
more than 4 different values per Offset defined by user. Operands This command has the following operands: port Specify the port number where you want defined monitor. This operand is required. grouplist Specify up to 6 sets of Offset, Mask, and ValueList separated by a semicolon (;). The - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 163
1 Telnet Commands Example alias SOFx frames are considered a special case. The Offset is specified as 0x0, valueList are Link Service request (R_CTL=0x22 and TYPE=0x01) to port 2: switch:admin> perfAddUserMonitor 2, "4, 0xff, 0x22; 12, 0xff, 0x01" User monitor #0 successfully added switch:admin - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 164
The default alias is SCSI_Write. Example To add a SCSI Write command monitor to a port: switch:admin> perfAddWriteMonitor 2 SCSI Write monitor #0 successfully added switch:admin> See Also perfAddEEMonitor perfAddIPMonitor perfAddReadMonitor perfAddRWMonitor perfAddSCSIMonitor perfAddUserMonitor - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 165
admin Description Use this command to clear the previously saved end-to-end and filter configuration settings (data structures) of performance monitoring from flash memory. Operands None. Example To clear the performance monitoring information from flash memory: switch:admin> perfcfgClear This will - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 166
Use this command to restore the performance monitoring configuration information from flash memory. Operands None. Example To restore the performance monitoring configuration information from flash memory: switch:admin> perfCfgRestore This will overwrite current Performance Monitoring settings in - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 167
to be saved over power off cycles. Operands None. Example To save the current performance monitoring configuration to firmware: switch:admin> perfCfgSave This will overwrite previously saved Performance Monitoring settings in FLASH ROM. Do you want to continue? [y|n]y Please wait ... Committing - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 168
Synopsis perfClrAlpaCrc port[, ALPA] Availability admin Description Use this command to clear specific ALPA device's CRC error counter. If on port 15: switch:admin> perfClrAlpaCrc 15, 0x59 CRC error count at ALPA 0x59 on port 15 is cleared. switch:admin> switch:admin> perfClrAlpaCrc 15 This - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 169
Availability admin Description Use this command to delete an end-to-end monitor on a port. Operands This command has the following operands: end-to-end monitor: switch:admin> perfDelEEMonitor 2, 5 End-to-End monitor number 5 deleted switch:admin> See Also perfShowEEMonitor perfAddEEMonitor - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 170
this command to display the available performance monitoring help commands. Operands None. Example To display commands related to performance monitoring: switch: perfShowFilterMonitor Save Performance configuration Restore Performance configuration Clear Performance settings from RAM Clear ALPA - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 171
specific port using the perfShowFilterMonitor command to make sure that the right monitor will be deleted. Operands This command has the following operands: port 4 on port 2: switch:admin> perfDelFilterMonitor 2, 4 The specified filter-based monitor is deleted. switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 172
eight EE monitors available on a port. The default EE mask value upon power-on is all eight EE monitors set. When you reset mask, the counters are also reset to 0. Operands This command has the following operands: port Specify the port number where you want to modify the end-to-end monitors - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 173
1 Telnet Commands Example To set the overall mask for end-to-end monitors: switch:admin> perfSetPortEEMask 6, "00:00:00", "ff:ff:ff", "00:00:ff", "ff:00:00" The EE mask on port 6 is set and EE counters are reset. switch:admin> See Also perfAddEEMonitor Fabric OS Reference 1-159 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 174
hexadecimal. Otherwise, CRC count is displayed in decimal format. Operands This command has the following operands: port Specify the port number where you want to on port 5: switch:admin> perfShowAlpaCrc 5 AL_PA CRC count 0x01 0 switch:admin> See Also perfClrAlpaCrc 1-160 Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 175
Transmitting frame count • Rx_count - Receiving frame count • Crc_count - CRC error count If you do not specify a value for the interval operand this command displays end to end monitor information and a cumulative count of the traffic detected by the monitor. If you specify a value for the interval - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 176
1 Telnet Commands Example To display end to end monitor frame traffic on port 5 at an interval of once a second: switch:admin> perfShowEEMonitor 5, 1 perfShowEEMonitor 4 1: Tx/Rx are # of bytes 40 0x00000004d0bade54 0x0000000067229e87 0x0000000000000000 6 0x11000 0x21fe0 WEB_TOOLS 192.168.169.40 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 177
count of the traffic detected by the monitor. If you specify a value for the interval operand this command displays a snapshot of the traffic at the specified interval. Operands This command has the following operand: port Specify the port number where you want to display the filter monitors - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 178
1 Telnet Commands Example To display filter monitor traffic on port 5 at an interval of once a second: switch:admin> perfshowfiltermonitor 5, 1 perfShowFilterMonitor 5 1 0 1 2 192.168.169.40 0x0000000000002208 6 SCSI_WR WEB_TOOLS 192.168.169.40 0x000000000000033a switch:admin> See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 179
mask is all fields set on. This command has the following operand switch:admin> perfShowPortEEMask 2 TxSID Domain: on TxSID Area: on TxSID ALPA: off TxDID Domain: on TxDID Area: on TxDID ALPA: off RxSID Domain: on RxSID Area: on RxSID ALPA: off RxDID Domain: on RxDID Area: on RxDID ALPA: off switch - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 180
1 Telnet Commands See Also perfAddEEMonitor perfDelEEMonitor perfShowEEMonitor perfSetPortEEMask perfShowPortEEMask 1-166 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 181
. Fabric management data, such as zoning information will not be exchanged through this port either. The configuration is saved in the non-volatile memory and is persistent across switch reboot or power cycle. Operands This command has the following operands: port Specify the port number to be - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 182
only changes the actions initiated by the switch; it does not change how the switch responds to initialization requests. The configuration is saved in the non-volatile memory and is persistent across switch reboot or power cycle. Operands This command has the following operands: port Specify the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 183
E_PORT. Locking a port as an L_PORT only affects what actions the switch initiates. It does not change how the switch responds to initialization requests. Operands This command has the following operands: port The port number to be configured. Valid values for port number vary depending on the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 184
Use this command to specify the allocation of enough full size frame buffers on a particular port to support a long distance link of up to 100 km. The port can be used as either an Fx_Port or an E_Port. The configuration is saved in the non-volatile memory and is persistent across switch reboot or - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 185
1 Telnet Commands Example To configure switch port 3 to support a 100 km link: switch:admin> portCfgLongDistance 3 Please enter the long distance level -- : (0..2) [0] 2 Committing configuration...done. See Also configure portShow switchShow Fabric OS Reference 1-171 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 186
. Since embedded processor is not involved, traffic moves at normal (and full) speed. Executing this command on a branch (middle) switch will not affect traffic. It can be configured for future use as an edge switch. The disadvantage is that the port cannot be used to connect to other devices. The - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 187
1 Telnet Commands Example To configure switch port 3 as a multicast loopback port: switch:admin> portCfgMcastLoopback 3, 1 Committing configuration...done. See Also portShow switchShow mcastShow configure Fabric OS Reference 1-173 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 188
E_Port or blank (--) when the port is allowed to function as an E_Port. This command is set by the portCfgEport command. Operands None. Example To display the configuration settings of ports on a switch: switch:admin> portCfgShow Ports 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Speed 2G 2G AN - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 189
portCfgLongDistance portCfgTrunkport portCfgSpeed 1 Telnet Commands Fabric OS Reference 1-175 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 190
the port is disabled and enabled so that the port comes up with the new speed setting. The configuration is saved in the non-volatile memory and is persistent across switch reboot or power cycle. If the command is specified without an operand, you are prompted to enter the speed value. The output of - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 191
command to configure a port to be enabled or disabled for trunking. Note: This command requires a Trunking license. Operands This command Example To enable port 5 for trunking: switch:admin> portCfgTrunkport 5, 1 Committing configuration...done. See Also switchCfgTrunk portShow portCfgShow - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 192
port. Synopsis portDisable port Availability admin Description Use this command to disable a switch port. If the port is connected to another switch, the fabric may reconfigure. If the port is connected to one or more devices, the devices can no longer communicate with the fabric. If the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 193
port. Synopsis portEnable port Availability admin Description Use this command to enable a switch port. If the port is connected to another switch, the fabric may reconfigure. If the port is connected to one or more devices, the devices can communicate with the fabric. For ports that come - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 194
users Description Use this command to display an error summary for all ports. The display contains one output line per port and shows minimum. Frames longer than maximum. Frames with bad end-of-frame delimiters. Encoding error outside of frames. Class 3 frames discarded. Link failures (LF1 or - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 195
1 Telnet Commands Example The following example shows an eight port switch. Notice in the example below that port six has a high number of errors and should be examined: switch:admin> portErrShow frames enc crc too too bad enc disc link loss loss frjt fbsy tx rx in err shrt long eof out c3 fail - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 196
log. Synopsis portLogClear Availability admin Description Use this command to clear the port log. You may want is not over-written). Operands None. Example To clear the port log: switch:admin> portLogClear switch:admin> portLogShow port log is empty Errors See Also The following errors - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 197
disabled Operands This command has the following operands: count Specify the maximum number of lines to be displayed. Only the most recent count entries are displayed. This operand is optional. saved Specify a nonzero value to display the saved port log from the last switch fault. See uptime - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 198
port log; 22 entries are displayed at a time. The portLogShow command displays the same information as portLogDump, but it allows you to enter a "return" after each page of output. If the port log is disabled, the following message appears as the first line. Refer to portLogClear command for more - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 199
depends on event type: ioctl Tx & Rx scn pstate ctin ctout errlog loopscn I/O control command code frame payload size new state. new physical state. Refer to Table 1-14 for a list of pstate code values. CT-subtype: fc = Simple Name Server, f8 = Alias Server. same as ctin above. error level (see - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 200
FC-PH busy reason ctin Argument 0 is divided into two 16-bit fields: [A] bit map indicating validity of subsequent args (0001 = argument 1 is valid, 0003 = arguments 1 and 2 are valid). [B] ct-based service command bitmap OLD usually zero TMO Encoded value of state when loop - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 201
Wait for OLS State Table 1-15 ioctl Codes ioctl Code Description 90 get virtual channel credits 91 Set virtual channel credits a1 Port is an E_Port a2 Port is an F_Port a3 Port is segmented selection done ad Multicast path selection done 1 Telnet Commands Fabric OS Reference 1-187 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 202
1 Telnet Commands Table 1-16 LIP Reason Codes LIP Code Description 8001 Retry loop init 8002 Start loop after 11010000 LISM 11020000 LIFA 11030000 LIPA 11040000 LIHA 11050100 LISA 11050000 OLD_LISA 11060000 LIRP 11070000 LILP 40 LPSM_MONITORING 1-188 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 203
1 Telnet Commands Operands Example This command has the following operands: count Specify the maximum number of lines to display. Only the most recent count entries are displayed. This operand is optional. saved Specify a non-zero value to display the saved port log from the last switch fault. - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 204
Availability admin Description Use this command to verify the functional operation of the switch by sending frames from the is running. Below is the test method: 1. Set all ports for parallel loopback. 2. Create a frame F of maximum data size (2112 bytes). 3. Transmit frame F through port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 205
1 Telnet Commands Operands Example This command has the following operand: passCount Specify the number of times (or number of frames per port) to execute this test. The default value is 0xfffffffe. This operand is optional. To run the portLoopbackTest 100 times: switch:admin> portLoopbackTest - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 206
, or megabytes. Synopsis portPerfShow [interval] Availability All users Description Use this command to display throughput information for all ports on the switch (8 or 16 columns depending on the switch model). One output line is displayed per interval (or second if no interval is specified - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 207
of the ASIC SRAMs and registers. Synopsis portRegTest Availability admin Description Use this command to verify that SRAM and register data bits in each ASIC can be of the ASIC SRAMs and registers: switch:admin> portRegTest Running Port Register Test .... passed. Fabric OS Reference 1-193 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 208
1 Telnet Commands Errors See Also Below are possible error messages if failures are detected: DIAG-REGERR DIAG-REGERR_UNRST DIAG-BUS_TIMEOUT ramTest centralMemoryTest cmiTest sramRetentionTest turboRamTest camTest statsTest filterTest portLoopbackTest spinSilk 1-194 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 209
entry for each active port: local_switch_domain_number: 0x10000 This is for routing unicast frames designated to the embedded port of the local switch 16 of the bitmap is always set to allow the switch element to receive broadcast frames. Operands This command has the following operand: Fabric - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 210
1 Telnet Commands Example port Specify the port number to be displayed. Valid values for port number vary depending on the switch type. This operand is required. To display the port routing tables for switch port 3: switch:admin> portRouteShow 3 port address ID: 0x604300 external unicast - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 211
All users. Description Use this command to display status information for a port. Information varies with the switch model and port type. The the port hardware registers. Address of the port driver private data. 24-bit D_ID for port. Port worldwide name. The port's long distance level. - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 212
1 Telnet Commands Table 1-18 PortShow display fields (Continued) Field Description Speed Interrupts the frame. This field will only be displayed when there are errors. Operands This command has the following operand: port Specify the port number to be displayed. Valid values for port number - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 213
Example To display the status for a specified E_Port: switch:admin> portShow 1 portFlags: 0x20041 PRESENT U_PORT LED portType: 3.1 portState: 2 Offline portPhys: 4 No_Light portScn: 0 portRegs: 0x80020000 portData: 0x10fa70a0 portId: 011100 portWwn: 20:01:00:60:69:00:73:71 Distance: - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 214
command to display port hardware statistics counters. The first section, below, is common to all hardware; one of the last two sections (depending on switch minimum. Frames longer than maximum. Frames with bad end-of-frame. Encoding error outside frames. Class 3 frames discarded. Number of OPNyx sent - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 215
command has the following operand: port Specify the port number to be displayed. Valid values for port number vary depending on the switch type. This operand is required. To display a port with only the basic set of statistics: switch BB_credit zero er_enc_in 0 Encoding errors inside of frames - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 216
All users Description Use this command to display the switch power supply status. The display format varies with switch model and number of power switch turned off, fuse blown, or other internal error). After the status line, a power supply identification line may be shown. If present, this line - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 217
"qloopname", "member;member" Availability admin Description Use this command to add one or more members to an existing QuickLoop. When a configuration is enabled, all QuickLoops defined in the configuration must resolve to one or two switch worldwide names. Zone alias names entered as members of - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 218
"qloopname", "member;member" Availability admin Description Use this command to create a QuickLoop. A QuickLoop name must begin with not allowed. When a configuration is enabled, all QuickLoops defined in the configuration must resolve to a maximum of two switch worldwide names. Zone alias names - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 219
. Synopsis qloopDelete "qloopName" Availability admin Description Use this command to delete a QuickLoop. When a configuration is enabled, all QuickLoops defined in the configuration must resolve to a maximum of two switch worldwide names. Operands The following operand is required: qloopName - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 220
"qloopName", "member;member" Availability admin Description Use this command to remove one or more members from a QuickLoop. The QuickLoop is deleted. When a configuration is enabled, all QuickLoops defined in the configuration must resolve to one or two switch worldwide names. Operands The - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 221
Display QuickLoop information. Synopsis qloopShow [pattern] Availability All users Description Use this command to display QuickLoop configuration information. If no parameters are specified, all zone configuration information (defined and enabled) is displayed. See cfgShow for a description of - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 222
1 Telnet Commands Example To display all QuickLoops beginning with the letter "q": switch:admin> qloopShow "q*" qloop: qlp1 qloop: qlp2 10:00:00:60:69:00:60:11 10:00:00:60:69:00:30:02 10:00:00:60:69:00:60:13 See Also qloopAdd qloopCreate qloopDelete qloopRemove 1-208 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 223
in use the qlDisable, qlEnable, and qlPartner commands are not in effect. In this case, the qlPortDisable command can be used to disable individual ports. Operands None. Example The following entry disables QuickLoop mode: switch:admin> qlDisable See Also qlEnable qlPortDisable qlShow Fabric - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 224
command to enable QuickLoop mode on a switch. All devices connected to QuickLoop ports are re-initialized to form a single loop. If a partner switch is configured share a single AL_PA space, and operate in accordance with FC-AL. QuickLoop initialization includes the following two steps: 1. Pass - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 225
command has the following operand: [0 | wwn] Specify 0 to set the QuickLoop to run on single switch. Specify a WWN to set the QuickLoop to run on dual switches. This operand is optional. If no operand is specified the current value is displayed. Example The following entry sets another switch - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 226
for this command to have effect. Operands This command has the following operand: port Specify the port number to be modified from QuickLoop mode to fabric mode. Valid values for port number vary depending on the switch type. This operand is required. Example The following entry changes port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 227
to have effect. Operands This command has the following operand: port Specify the port number to be modified from fabric mode to QuickLoop mode. Valid values for port number vary depending on the switch type. This operand is required. Example The following entry changes port 4 from fabric mode - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 228
qlPortShowAll Availability All users Description Use this command to display the following QuickLoop port information: in QuickLoop mode Operands None. Example The following entry displays QuickLoop port information: switch:admin> qlPortShowAll PortNum QuickLoop Mode Port State 0 Disabled - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 229
Availability All users Description Use this command to display the following QuickLoop information: Self: Worldwide name and domain ID of this switch Peer: Worldwide name and domain ID of partner switch. Peer is displayed only if the switch has a partner configured State: The state of the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 230
1 Telnet Commands Example The following entry displays QuickLoop information: switch:admin> qlShow Self: 10:00:00:60:69:20:26:2a domain 1 State: Online Scope: single AL_PA bitmap: 00000000 00000000 00000000 00000000 Local AL_PAs (not available) Local looplet states Member: 0 1 2 3 4 5 6 7 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 231
valid when two switches are configured to run as peers in QuickLoop. QL enabled: Number of times QuickLoop is enabled QL disabled: Number of times QuickLoop is disabled Port caused QL init: Port that caused last QuickLoop initialization Operands None. Example The following entry displays QuickLoop - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 232
off. Synopsis quietMode [0|1] Availability All users (display) admin (set/clear) Description Use this command to change the output displayed on the switch console (serial port or telnet session). By default, quiet mode is off and all switch tasks can send output to the console, including output - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 233
switch. Synopsis ramTest [patternSize] Availability admin Description Use this command to verify the address and data bus of the SDRAMs that serve as CPU memory in the switch 9. Only the data subtest is configurable. The address subtest is always executed. This operand is optional. Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 234
1 Telnet Commands Example To run the RAM test on a switch: switch:admin> ramTest Running System DRAM Test ...... passed. Errors See Also Listed below are possible error messages if failures are detected: DIAG-MEMORY DIAG-MEMSZ DIAG- - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 235
Synopsis reboot Availability admin Description Use this command to reboot the switch. The reboot takes effect immediately as the switch resets, then executes the normal power-on booting sequence. While the switch is rebooting, the telnet session is closed and all Fibre Channel ports are inactive - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 236
Delivery Print state of In-Order Delivery Set or print the FSPF cost of a link Print Link State Database entry Print multicast tree information Print neighbor's summary information Reset FSPF neighbor's counters Print paths to domain(s) Configure static unicast route Remove static unicast route - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 237
problem. Operands This command has the following operand: 0|1 Specify 1 to enable GBIC mode or 0 to disable GBIC mode. The default value (if no operand specified) is 0. This operand is optional. Example To enable or disable GBIC mode: switch:admin> setGbicMode 1 Committing configuration - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 238
not require a reboot to take effect. The SPLB mode, when enabled, forces the spinSilk command to disable two port loopback for M->M connected ports. This may be useful to isolate internal switch problems from GBIC problems since the internal paths are used much less with SPLB mode enabled. The SPLB - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 239
will be prompted. This command makes the same change to all switches in the specified group. It executes on every switch in the group if and only if each switch in the group can perform the action. Note: This command is for the FC 6164 switch only. Operands This command has the following operands - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 240
Note: This command is for the FC 6164 switch only. Operands This command has the switch:admin> sgroupRename "MyGroup", "MyNewGroup" Committing configuration...done. switch:admin> sgroupShow Group Type Group Name Member WWN S32_6_1 MyNewGroup 10:00:00:60:69:00:00:20 10:00:00:60:69:20 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 241
, the session will become an interactive session for which all the parameters will be prompted. Note: This command is for the FC 6164 switch only. Operands This command has the following operands: sgType Specify a character string in quotation marks containing the sgroup type, for example - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 242
Commands Example To set a group called "My Group" of type "S32_6_1" using Domain IDs 1 through 6: switch:admin> sgroupSet "S32_6_1", "MyGroup", "1,2,3,4,5,6" Committing configuration...done. To create an sgroup using the interactive form of the sgroupSet command: switch 00:00:60:69:20:15:71 For - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 243
will be displayed. Note: This command is for the FC 6164 switch only. Operands This command has the following operands: sgType To display all switch group configurations: switch:admin> sgroupShow Group Type Group Name Member WWN S32_6_1 MyNewGroupName 10:00:00:60:69:00:00:20 10:00:00: - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 244
1 Telnet Commands See Also sgroupDelete sgroupRename sgroupSet sgroupSupportShow sgroupSwReplace 1-230 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 245
in place of a command name, all the supported commands are displayed for the all the switches within a switch group. If a single command is specified, only the information for that command is displayed. Note: This command is for the FC 6164 switch only. Operands This command has the following - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 246
1 Telnet Commands Example To display the temperature in all the switch components of an FC 6164 : switch:admin>sgroupsupportshow "starbase", " 84 89 91 91 Fahrenheit Information from Domain 9 27 29 33 34 32 Centigrade 80 84 91 93 89 Fahrenheit Information from Domain 10 26 30 31 34 31 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 247
switch in the group if and only if each switch in the group can perform the action. Note: This command is for the FC 6164 switch only. Operands This command has the following operands: sgName Specify the switch 10:00:00:60:69:20:55:55"). The WWN must be enclosed in quotation marks. This operand - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 248
:00:00:60:69:20:15:2a 10:00:00:60:69:20:18:32 10:00:00:60:69:20:22:22 10:00:00:60:69:20:64:31 switch:admin> sgroupSwReplace "NewGroup", "10:00:00:60:69:20:22:22", "10:00:00:60:69:20:55:55" Committing configuration...done. switch:admin> sgroupShow Group Type - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 249
in the SW traps. The default value is no. Operands None. Example To view or modify the options for configuring SNMP MIB traps: switch:admin> snmpmibcapset The SNMP Mib/Trap Capability has been set to support FE-MIB SW-MIB FA-MIB SW-TRAP FA-TRAP FA-MIB (yes, y, no, n): [yes] SW-TRAP (yes - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 250
Commands spinFab Test for Cascaded switch ISL links. Synopsis spinFab [ nMillionFrames [, ePortBeg [, ePortEnd [, setFail]]]] Availability admin Description Used to verify the intended functional operation of the ISL links between switches at the maximum speed of 2Gbps by setting encoder error - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 251
1 Telnet Commands ePortEnd setFail The last port to test. The test will be performed on failed ports as bad. To minimize the impact on live fabrics this test normally logs errors but does not set the port status to FAILED. This parameter is provided to force the failing ports to be marked as BAD - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 252
1 Telnet Commands Example In the following examples ports 0-3 are active ISL links. Port 4 is an F_port so the test skips it. switch:admin> spinfab 3,0,4 spinFab running... spinFab: Completed 3 megs, status: passed. port 0 test status: 0x00000000 -- passed. port 1 test status: 0x00000000 -- passed. - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 253
verify the functional operation of the switch components. Note: The spinsilk command may not be executed on an operational switch. You must first disable the switch using the switchDisable command. This command verifies the functional operation of the switch by setting up the routing hardware such - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 254
>>> is a cable or internal loop-back -> is a routing table entry The connections between pairs of M->M ports are chosen to exercise the connections between : switch:admin> setGbicMode 0 Prior to running this command make sure you disable the switch, set the GBIC mode to 1, and install loopback - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 255
set for the switch. You can set GBICmode as an operand or by using the setgbicmode command. will result in 1G for HP Brocade 2400 and 2800 switches. This option initiates a negotiation Auto negotiate This option is valid only for switches that support 2G connections. For useful results this test - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 256
1 Telnet Commands Example To verify the functionality of a switch: switch:admin> spinSilk 2 Running Spin Silk One moment please ... switchName: switch switchType: 2.2 switchState: Testing switchRole: Disabled switchDomain: 1 (unconfirmed) switchId: fffc01 switchWwn: 10:00:00:60:69: - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 257
1 Telnet Commands Diagnostics Status: Tue Apr 6 04:10:12 1999 port#: 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 diags: OK OK OK OK OK OK OK OK OK - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 258
following operand: passCount Specify the number of times to execute the test. The default value is 1. This command is optional. Example To run a data retention test: switch:admin> sramRetentionTest Running SRAM Retention Test ... passed. Errors See Also Below are the possible error messages if - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 259
a statistics counter diagnostic test on a switch. This command may not be executed on an operational switch. You must first disable the switch using the switchDisable command. Operands None. Example To run a statistics counter test on a switch: switch:admin> statsTest Running Statistics Cnt Test - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 260
users Description Use this command to print the switch information for debugging purposes. This command executes the listed commands in the following order fabricShow 17.topologyShow 18.qlShow 19.nsShow 20.nsAllShow 21.cfgShow 22.configShow 23.faultShow 24.traceShow 25.portLogDump 1-246 Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 261
firstPort information is printed for the port based commands (portShow, portRegShow, portRouteShow). If no operand is supplied, firstPort is set to 0 and lastPort is set to maximum port of switch. This operand is optional. nLog Specify the number of lines of portLogDump to print: • 0 = dump all - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 262
beaconing mode on or off. Synopsis switchBeacon 0|1 Availability admin Description Use this command to set the switch beaconing mode on (if the operand is 1) or off (if the operand is 0). When beaconing mode is turned on, the port LEDs flash amber in a - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 263
will be at fixed speed of 2 Gbps. If the command is specified without an operand, you are prompted to enter a value. Example To set the speed level for all ports on a switch: switch:admin> switchCfgSpeed 2 Committing configuration...done. switch:admin> See Also portCfgSpeed switchShow Fabric OS - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 264
This command has the following operand: 0|1 Specify 1 to enable trunking on all the ports on this switch. Specify 0 to disable trunking on all the ports on this switch. This operand is required. Example To enable trunking on a switch: switch:admin> switchCfgTrunk 1 Committing configuration - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 265
are taken offline; if the switch was part of a fabric, the remaining switches reconfigure. The switch must be disabled before making configuration changes (using configure or configDefault) or before running many of the diagnostic tests. All commands that require the switch to be disabled send an - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 266
if it was previously disabled to make configuration changes or to run diagnostics. If the switch is connected to a fabric, it rejoins the fabric. When this command is issued, the 10 second fabric stability count down is displayed. If this switch remains the principal switch at the end of the count - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 267
set) Description Use this command without a operand to display the current switch name. This name is also shown in the telnet prompt, under each switch icon on the WEB TOOLS switch name causes a domain address format RSCN to be issued (see FC-FLA for a description of RSCNs). Operands This command - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 268
summary information by port. Switch summary information: switchName Switch symbolic name. switchType Switch firmware revision number. switchState Switch state: online, offline, testing, faulty. switchRole Switch role: principal, subordinate, disabled. switchDomain Switch domain ID: 0-31 or - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 269
1 Telnet Commands comment Operands None. No_Sync - module receiving light but out of sync master is port #x) - This port is configured as a trunking port, the master port is port number x. (upstream) - This E-port is an upstream path towards the principal switch of the fabric. (downstream) - This - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 270
1 Telnet Commands Example The following example shows a 16 port switch: sw14:admin> switchshow switchName: sw14 switchType: 9.1 switchState: Online switchRole: Subordinate switchDomain: 2 switchId: fffc02 switchWwn: 10:00:00:60:69:50:02:8f switchBeacon: OFF port 0: - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 271
default values, if there is 1 faulty port in a switch, then this contributor would set the overall switch status to MARGINAL. If 2 ports were faulty, then this contributor would set the overall switch status to DOWN. This command enables you to set a threshold for each contributor, so that a certain - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 272
Commands Operands Example When PortStatus monitoring is set to values of (0,0), port status changes are not logged to the event log and console. Similarly, GBIC removal does not generate a message to the event log and console if MissingGBICs is set to (0,0). By configuring to the switch. ** Simply - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 273
switch status. Synopsis switchStatusPolicyShow Availability all users Description Use this command to view the current policy parameters set for the switch values for the policy parameters are as follows: Table 1-20 Contributor Value and Status Contributor Default Value for DOWN Default - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 274
1 Telnet Commands Example To display the switch status policy: switch:admin> switchStatusPolicyShow The current overall switch status policy parameters: Down Marginal FaultyPorts 1 0 MissingGBICs 0 1 PowerSupplies 2 1 Temperatures 3 1 Fans 3 1 PortStatus 0 0 sgroup ISLStatus 2 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 275
switchStatusShow Availability All Users Description Use this command to display the overall status of the switch. The overall status is calculated based on the most severe status of all contributors: • Internal Switch Status • Faulty Ports • Missing GBICs • Power Supplies • Fans • Temperatures - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 276
files and/or users, depending on the system configuration. When one or more IP addresses are configured, the switch forwards all error log entries to the syslogd on the specified server(s). Up to six servers are supported. Operands This command has the following operand: IPaddress Specify the IP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 277
address of the server which is running the syslogd process. Operands This command has the following operand: IPaddress Specify the IP address of the server which system messages are sent: switch:admin> syslogdIpRemove "192.168.1.60" Committing configuration...done. See Also errShow - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 278
IP addresses. Synopsis syslogdIpShow Availability All users. Description Use this command to display all syslog daemon IP addresses in the configuration database. Operands None. Example To display all syslog daemon IP addresses: switch:admin> syslogdIpShow syslog.IP.address.1: 191.168.1.60 syslog.IP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 279
command to display the current temperature readings from each of the five temperature sensors located on the main printed circuit board of the switch display the temperature readings for a switch: switch:admin> tempShow 26 26 27 27 26 Centigrade 78 78 80 80 78 Fahrenheit See Also fanShow psShow Fabric - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 280
| minutes] Availability all users (display) admin (set/clear) Description This command changes the telnet timeout value used by the shell. then change it to 10 minutes: switch:admin> timeOut TimeOut is Disabled switch:admin> timeOut 10 Committing configuration...done. TimeOut is now 10 minutes - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 281
to use the corresponding Out Port to reach the destination domain. A bit set to 1 indicates port is being routed through the corresponding Out Port. The path selection protocol. Name: Name of destination switch. Operands This command has the following operand: domainnumber Specify the destination - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 282
1 Telnet Commands Examples To display the unicast fabric topology: switch:admin> topologyShow Local Domain ID: 1 Domain Metric Hops Out Port In Ports Flags Name 0 1000 1 2 0x00002000 D "sw25 1 6 0x00000000 D 1 7 0x00000000 D 3 1000 1 13 0x000000c4 D "sw4" 4 2000 2 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 283
. The first sets the track-changes feature and disables SNMP TRAP messages. The second disables both the track-changes feature and SNMP TRAP messages. switch:admin> trackChangesSet 1, 0 0x10f9bcd0 (tShell): Feb 10 15:04:38 Error TRACK-TRACK_ON, 4, Track-changes on Committing configuration...done - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 284
from the Track Changes feature is dumped to the error log for the switch. Use the errDump command or errShow command to view the error log. Example To display the status of the track-changes feature: switch:admin> trackChangesShow Track changes status: ON Track changes generate SNMP-TRAP: YES See - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 285
trunkDebug port1, port2 Availability admin Description Use this command to debug a trunk link failure. This command reports one of the following messages based on the trunking properties of the two specified ports: • Switch does not support trunking • Trunking license required • port is - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 286
Display trunking information. Synopsis trunkShow Availability all users Description Use this command to display trunking information. The fields displayed are as follows: Trunking Group Number Displays each trunking group on a switch. All the ports that are part of this trunking group are - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 287
test for 2Gb ASICs. Synopsis turboRamTest [passcount] Availability admin Description This command verifies the on chip SRAM located in the 2Gb ASIC using the Definition Block RAM 19. Frame Filtering Destination CAM 20. Frame Filtering Source CAM 21. Special Memory RAM Fabric OS Reference 1-273 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 288
turbo-ram r-m-w dec 2) 6. Repeat steps 1-5 with AAAA 5555 pattern. This command has the following operand: passcount Specify the number of turboRamTest passes to execute this test. To execute this test three times: switch:admin> turboRamTest 3 Running Turbo RAM Test ........ passed. - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 289
All users Description Use this command to display the length of Firmware caused a nonmaskable interrupt. Note: The items marked with an asterisk (*) are usually caused by hardware or firmware failures. Information on the failure is stored in the switch. Follow the procedures in the switch manual - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 290
1 Telnet Commands Example To display the uptime for a switch: switch:admin> uptime Up for: 3 days, 18:35 Powered for: 30 days, 16:05 Last up at: Mon Mar 22 12:00:00 1999 Reason: Power-on See Also date errShow fastboot reboot 1-276 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 291
of the switch to achieve optimum load sharing may be impaired. To prevent routing loops, static route configuration using a non-minimum cost path is not allowed. If you attempt to configure such a route, you are asked if the entry should be saved in the database. Operands This command has the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 292
port, domainnumber Availability admin Description Use this command to remove a configured static route. When this command is issued, the route to the specified in from port 1 and addressed to domain 2: switch:admin> uRouteRemove 1, 2 See Also configShow uRouteConfig uRouteShow 1-278 Fabric - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 293
(Dom, Port):Domain and port number of the next hop. These are the domain number and the port number of the switch to which Out Port is connected. Operands This command has the following operands: port Specify the port number you want to view the unicast routing information for. Valid values for - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 294
1 Telnet Commands Examples To display the unicast routing information: switch:admin> uRouteShow Local Domain ID: 1 continue, Q to stop: 13 0 7 1000 1 D 0,8 4 2 2000 2 D 0,13 switch:admin> uRouteShow 13 Local Domain ID: 1 In Port Domain Out Port Metric Hops Flags Next(Dom,Port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 295
Use this command to display firmware version information and build dates. The following is displayed: Kernel: Version of switch kernel operating system Fabric OS: Version of switch Fabric OS Made on: Build date of firmware running in switch Flash: Build date of firmware stored in - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 296
zoneAdd "zoneName", "member;member" Availability admin Description Use this command to add one or more members to an existing zone. Operands name Example To add aliases for three disk arrays to "Blue_zone": switch:admin> zoneAdd "Blue_Zone", "array3; array4; array5" See Also zoneCreate - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 297
of AL_PAs, for example "qloop1[01,02]". QuickLoop names have the same format as zone names, and are created with the qloopCreate command to define a switch or pair of switches that form the QuickLoop. Specify a zone alias name using the same format as a zone name; it is created with the aliCreate - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 298
1 Telnet Commands Example zoneName member Name for a zone to be created, in quotation marks of port numbers and zone aliases: switch:admin> zoneCreate "Red_zone", "1,0; loop1" switch:admin> zoneCreate "Blue_zone", "1,1; array1; 1,2; array2" switch:admin> zoneCreate "Green_zone", "1,0; loop1; - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 299
" Availability admin Description Use this command to delete a zone. Operands This command has the following operands: zoneName Name of the zone to be deleted, in quotation marks. This operand is required. Example To delete the zone "Blue_zone": switch:admin> zoneDelete "Blue_zone" See Also - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 300
zoneRemove "zoneName", "member;member" Availability admin Description Use this command to remove one or more members from an existing zone. • Zone alias names Example To remove "array2" from "Blue_zone": switch:admin> zoneRemove "Blue_zone", "array2" See Also zoneAdd zoneCreate zoneDelete - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 301
Description Use this command to display zone configuration information. If no parameters are specified, all zone configuration information (both Example To show all zones beginning with the letters "A" through "C": switch:admin> zoneShow "[A-C]*" zone: Blue_zone 1,1; array1; 1,2; array2 See - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 302
1 Telnet Commands 1-288 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 303
page 2-19 System Error Message Formats Error message formats for the switch are the same whether you are accessing the information from the the buffer limit is exceeded, the oldest message is deleted. The errShow command displays all detected errors. The following information is displayed: • Task ID - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 304
(Bm1.0) Failed Turbo RAM dec r/w test: phy=0x811088a0 wrd cnt=448 dec size=8 bytes rpt=0xaaaaaaaa wpt=0x55555555 msk=0x000001ff Err# 0FA2 Type to continue as an admin user to the switch, using a telnet connection. 2. From the prompt, enter the errShow command. 3. To scroll through the error - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 305
which has been marked BAD, clear the port and set to OK using the diagClearError command. This command clears the port status only and does not clear the . filterTest Functional test of filter configuration. portLoopbackTest spinsilk Functional test of switch by sending and receiving frames from - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 306
Diagnostic Test Failure and Recovery Actions The table below lists what actions to perform if the switch fails any of the diagnostic tests. Note: If you run the portStatsShow or the diagShow command prior to running an individual test, errors may appear as a result of the normal synchronization - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 307
Table 2-3 Error Message Numbers (Continued) Error Number Test Name 0110 0111 0112 0415 0416 ramTest * portRegTest * 040F 1020 centralMemoryTest * 1021 1025 1026 1027 1028 1029 102A 102B 102C 103O 106F 2030 cmiTest * 2031 2032 2033 2034 2035 2036 223B camTest * 223C 2 Error - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 308
2 Error Messages Table 2-3 Error Message Numbers (Continued) Error Number Test Name 2640 2641 2642 2643 2644 portLoopbackTest * 2645 2646 2647 264F 265F 266E 266F 2660 2661 2662 2670 2671 Error Name DIAG-ERRSTAT (ENCIN) DIAG-ERRSTAT (CRC) DIAG-ERRSTAT (TRUNC) DIAG-ERRSTAT (2LONG) DIAG- - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 309
Table 2-3 Error Message Numbers (Continued) Error Number Test Name 3040 3041 3042 3043 3044 crossPortTest 3045 3046 3047 304F 305F 3060 3061 3062 306E 306F 3070 3071 3078 2 Error Messages Error Name DIAG-ERRSTAT(ENCIN) DIAG-ERRSTAT(CRL) DIAG-ERRSTAT(TRUNC) DIAG-ERRSTAT(2LONG) DIAG- - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 310
-PORTM2M 3881 DIAG-NOSEGMENT * These tests are run during the POST (power on self test). For more information about these tests, refer to the individual command description in Chapter 3, Licensed Telnet - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 311
Replace mainboard assembly [portRegTest, sramRetentionTest] DIAG-CAMINIT Err#223B [camTest] Port failed to initialize due to one of the following reasons: • Switch not disabled • Diagnostic queue absent • Malloc failed • Chip is not present • Port is not in loopback mode • Port is not active - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 312
2 Error Messages Table 2-4 Diagnostic Error Messages (Continued) Message Description Probable Cause Action DIAG-CMERRTYPE Err#102A [centralMemoryTest] DIAG-CMICKSUM Err#2036 [cmiTest] DIAG-CMIDATA Err#2035 [cmiTest] DIAG-CMIINVCAP Err#2034 [cmiTest] DIAG-CMINOCAP Err#2033 [cmiTest] DIAG-CMISA1 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 313
frame • CRC_err - Cyclic redundancy check on frame failed • TruncFrm - Truncated frame • FrmTooLong - Frame too long • BadEOF - Bad end of file • Enc_out - Encoding error, outside frame • BadOrdSet - Bad symbol on fiber-optic cable • DiscC3 - Discarded Class 3 frames Port failed to go active in the - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 314
failure initiated did not complete within the timeout period Replace mainboard assembly Test failed to malloc mainboard failure Replace mainboard assembly Memory size to be tested is less than or mainboard failure equal to zero Replace mainboard assembly Data read from RAM location did not - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 315
or fiber cable ASIC failure Replace mainboard assembly [crossPortTest] DIAG-POST_SKIPPED POST is skipped Informational Only None required Err# 0004 [switch initialization] DIAG-REGERR Err#0B15, 0415 [portRegTest, sramRetentionTest] Data read from ASIC register or ASIC SRAM did not match data - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 316
The system automatically resorts to the default configuration settings. CONFIG OVERFLOW The switch configuration information has grown too large to be saved or has an invalid size. OS error Contact HP technical support CONFIG VERSION The switch has encountered OS error an unrecognized version - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 317
entry for local OS error Link State Record Action Contact HP technical support Contact HP technical support Contact HP technical support The system attempts to recover from its mirrored backup. Contact HP technical support. Contact HP technical support Contact HP technical support Contact HP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 318
Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 319
loop partner switch is running a lower (than v2.1.3) version of the software. OS error Upgrade to a higher version of the Fabric OS. RPC, SVC_EXIT An RPC service daemon has OS error terminated prematurely or unexpectedly. Contact HP technical support RPC, SVC_REG An RPC service daemon could - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 320
Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP technical support Contact HP - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 321
message is fopportState003. The threshold label in the first error message is (FOP Port State Changes 3). 0x1003f2d0 (tThad): May 22 19:20:23 Error FW-BELOW, 3, fopportState003 (FOP Port State Changes 3) is below low boundary. current value : 0 Change(s)/minute. (normal) 0x1003f2d0 (tThad): May - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 322
error: CRC Performance end to end monitor: perfEE Crc error: CRC Transmission counter: TX Receiving counter: RX Performance filter monitor: perfFilt Filter frame counter: frame 2-20 Fabric OS Reference - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 323
Fabric Watch Commands on page 3-4 • FC 6164 Commands on page 3-4 • Trunking Commands on page 3-5 • Performance Monitoring Commands on page 3-5 Note: For more information about Zoning, QuickLoop, Extended Fabrics, Fabric Watch, Trunking, or Performance Monitoring refer to the specific user guide for - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 324
information about QuickLoop refer to the QuickLoop User's Guide. Table 3-2 QuickLoop Commands Command Description qlDisable Disables QuickLoop mode on the switch. qlEnable qlPartner qlPortDisable Enables QuickLoop mode on the switch. Specifies a partner for a QuickLoop or displays information - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 325
be displayed. Displays a set of statistics for each QLFA host on the switch. Extended Fabric Command The following commands are available with the Fabrics User's Guide. Table 3-4 Extended Fabric Commands Command Description portCfgLongDistance Configure a port to support long distance links - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 326
configuration and status. fwShow Displays the thresholds monitored by Fabric Watch. FC 6164 Commands The following commands are specific to the administration of the FC 6164 switch. For more detailed information about the FC 6164 refer to the FC 6164 Product Guide. Table 3-6 FC 6164 Commands - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 327
Guide. Table 3-7 Trunking Commands Command Description portCfgTrunkport Configure a port for trunking. switchCfgTrunk Configure a switch monitoring settings from flash memory. Restore performance monitoring settings from flash memory. Save the current performance monitoring settings to - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 328
3 Licensed Telnet Commands Table 3-8 Performance Monitoring Commands Command Description perfDelFilterMonitor perfHelp perfSetPortEEMask perfShowAlpaCrc perfShowEEMonitor Delete a filter-based monitor. Display performance monitoring help information. Set overall mask for end-to-end (EE) - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 329
8b/10b Encoding An encoding scheme that converts each 8-bit byte into 10 bits. Used to balance ones and zeros in high-speed transports. Address Identifier A 24-bit to interface with a set of services. A shared 100 MBps Fibre Channel transport structured as a loop. Can support up to 126 devices - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 330
. Connectionless service for control traffic between switches, with notification of delivery or nondelivery of data between the E_Ports. A specified set of delivery characteristics and attributes for frame delivery. Comma A unique pattern (either 1100000 or 0011111) used in 8B/10B encoding to - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 331
1 and 2 services to manage the exchange of frames across the fabric between source and destination. See also End-to-end Flow Control, BB_Credit. EIA Rack A storage rack that meets the standards set by the Electronics Industry Association. Enabled Zone The currently enabled configuration of zones - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 332
initialization of Fibre Channel switches in order to create a multi-switch Fibre Channel fabric. Fibre Channel A protocol service that supports communication between Fibre Channel service Transport providers. See also FSP. Fill Word Firmware An IDLE or ARB ordered set that is transmitted during - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 333
. See also Target. The fabric created by the HP FC 6164, consisting of six Silkworm 2250 switches cabled together and configured to handle traffic as a seamless group. IOD ISL ISL Trunking Isolated E_Port In-order Delivery; a parameter that, when set, guarantees that frames are either delivered in - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 334
Link Services A AL_PA values in an arbitrated loop. A set of devices connected in a loop to that is based on 1300mm lasers and supports link speeds of 1.0625 Gbps. May configuration and device information. The MIB types provided with HP Brocade switches are described in the MIB Reference Manual - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 335
an equipment port to the fabric in a loop configuration through an FL_Port. See also N_Port, Nx_Port. A Set A transmission word that uses 8B/10B mapping and begins with the K28.5 character. Ordered sets Self-Test; a series of tests run by a switch after it is turned on. Private NL_Port An NL_Port - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 336
gateway. See also Distributed Fabrics. Request Rate The rate at which requests arrive at a servicing entity. See also Service Rate. Route Routing As applies to a fabric, the communication path between two switches. May also apply to the specific path taken by an individual frame, from source to - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 337
; a switch service that stores the configuration of the switch by F_Ports. • Arbitrated loop - Multiple NL_Ports connected in a loop. A mode in which private devices can communicate with public devices across the fabric. Transmission A 10-bit character encoded according to the rules of the 8B/10B - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 338
U_Port UDP ULP ULP_TOV Unicast Web Tools Well-known Address Universal Port; a switch port that can operate as a G_Port, A specified set of zones. Enabling a configuration enables all zones in that Configuration configuration. See also Defined Configuration, Enabled Configuration. Zoning A - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 339
1-30 configDefault 1-32 configDownload 1-33 configShow 1-35 configUpload 1-37 configure 1-39 CRC_err 3-11 crossPortTest 1-47 D date 1-51 diagClearError 1- firmwareDownload 1-73 FrmTooLong 3-11 fspfShow 1-75 fwClassInit 1-79 fwConfigReload 1-83 fwConfigure 1-80 fwShow 1-89 G gbicShow 1-91 Index-1 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 340
1-93 help 1-94 I i command 1-95 ifModeSet 1-97 ifModeShow 1-98 ifShow 1-99 interfaceShow 1-100 iodReset 1-105 iodSet 1-106 iodShow 1-107 ipAddrSet 1-108 ipAddrShow 1-109 islTopoCheck 1-111 islTopoShow 1-112 L licenseAdd 1-114 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 341
1-263 syslogdIpShow 1-264 system error message formats 3-1 system error messages 3-14 Fabric OS Reference T technical support xiii telnet commands supportShow command xiii tempShow 1-265 timeOut 1-266 topologyShow 1-267 trackChangesSet 1-269 TruncFrm 3-11 U uptime 1-275 uRouteConfig 1-277 - HP StorageWorks 8B | Fabric OS Reference Manual (Version 3.0) - Page 342
Index-4 Fabric OS Reference
reference manual
version 3.0
fabric os
www.hp.com