HP StorageWorks 9100 HP StorageWorks 9100 Extreme Data Storage System release
HP StorageWorks 9100 - Extreme Data Storage System Manual
View all HP StorageWorks 9100 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks 9100 manual content summary:
- HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 1
HP StorageWorks 9100 Extreme Data Storage System release notes V1.0.2 Part number: AN540-96015 Fourth edition: June 2009 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 2
Legal and notice information © Copyright 2009 Hewlett-Packard Development Company, L.P. - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 3
Supersedes HP StorageWorks 9100 Extreme Data Storage System versions 1.0 and 1.0.1 Contents of the 1.0.2 release • HP ExDS9100 systems manufactured after June 2009 contain Virtual Connect 1/10Gb-F modules instead of the previous Virtual Connect modules. The software continues to support either - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 4
HP StorageWorks 9100 Extreme Data Storage System contains updates to the firmware of the following components: • iLO: new version: 1.70-This is the minimum supported update instructions. • SAS switch module management firmware: new version: 1.1.8.0-The process is described in the update instructions. - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 5
all dirty user pages after a write rollback. Fixes in 1.0.1 The 1.0.1 release includes fixes for the following issues: • 25038: Fixed a problem that caused all disk drives to be in the "removed" state after ExDS9100cc controller hang. HP StorageWorks 9100 Extreme Data Storage System release notes 5 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 6
psfs_mpbbuf.c:254 assertion failure. This problem has now been resolved. • 25556: Resolved a problem where a blade server panics when booted with system under heavy load. • 24760: Fixed issues with the exdsmgr identify storage command. Operating systems Linux Languages English Update procedure This - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 7
again. b. Execute the update script a second time to complete the update: # cd ExDS-1.0.2-4811_update # ./InstallUpdate1.0.2.sh Output from the command is similar to the following: HP StorageWorks 9100 Extreme Data Storage System release notes 7 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 8
is running in single user mode as follows. This process is described in chapter 5 of the HP StorageWorks Extreme Data Storage System 9100 administration guide. • If the system exports filesystems using NFS, disable all export groups. If you use the standard exds_expd_default export group, disable - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 9
the correct firmware. Lines with an asterisk (*) in front of them indicate an error. See Chapter 14 of the HP StorageWorks Extreme Data Storage System 9100 administration guide for more information about exds_stdiag. 13. Update the SAS switch module management firmware as follows: a. ssh onto the OA - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 10
problem that guide, section "Booting the system and individual server blades." 16. Run the exdsmgr syscheck command to validate that the system is operating normally. Known issues and workarounds Issue Description 23369 Sendmail service HP ExDS or Administrator username. For example, on a system - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 11
: 25188 it indicates that the server environmental monitoring has encountered a problem. Workaround: Schedule a reboot of the HP server blade to correct this issue. Restarting the hpasm software does not correct the problem. HP StorageWorks 9100 Extreme Data Storage System release notes 11 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 12
. Otherwise, on reboot, all servers mount all filesystems. Example: Assume a system with 16 servers called exdsdemo [1-16] and 8 filesystems (fs1 through fs8 mx fs unmount --persistent --active psv2 ALL_SERVERS • mx fs mount --persist --activate --path /mnt/fs1 psv2 exdsdemo1 exdsdemo2 OR • mx - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 13
the mysqld service Usually, you can determine the source of the problem and of the problem is not immediately obvious from the mx alert status Instructions for doing this are described in Chapter 13 of the ExDS9100 administration guide HP StorageWorks 9100 Extreme Data Storage System release notes 13 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 14
is created. 27091 Used field incorrect if mx fs destroy command used. If the mx fs destroy command is used to delete is described in the HP StorageWorks 9100 Extreme Data Storage System administration guide section "Replacing the HP ExDS9100cx I/O module." 28204 'service somon_scripts restart' 14 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 15
Issue Description 28761 HP ExDS9100cc controller has amber LED and H1 or H2 code in the 7- process, you have cleared the fault. If this has not resolved the fault, contact HP Support for more information. Effective date June 2009 HP StorageWorks 9100 Extreme Data Storage System release notes 15 - HP StorageWorks 9100 | HP StorageWorks 9100 Extreme Data Storage System release - Page 16
16
HP StorageWorks 9100 Extreme Data
Storage System release notes
V1.0.2
Part number: AN540
–
96015
Fourth edition: June 2009