HP StorageWorks D2200sb HP StorageWorks D2200sb PCIe Storage Blade Maintenance
HP StorageWorks D2200sb - Storage Blade Manual
View all HP StorageWorks D2200sb manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks D2200sb manual content summary:
- HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 1
HP StorageWorks D2200sb PCIe Storage Blade Maintenance and Service Guide Part Number 611258-001 November 2010 (First Edition) - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 2
. Intended audience This guide is for an experienced service technician. HP assumes you are qualified in the servicing of computer equipment and trained in recognizing hazards in products with hazardous energy levels and are familiar with weight and stability precautions for rack installations. - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 3
electrostatic discharge ...19 Symbols on equipment...19 Storage blade warnings and cautions 20 Storage blade preparation ...20 Power down the partner server blade 21 Remove the storage blade ...21 Remove the hard drives...22 Remove the access panel ...23 Install the access panel ...23 Hard drive - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 4
period HP (or HP service providers or service partners) identifies that the repair can be accomplished by the use of a CSR part, HP will ship is required, you can call the HP Technical Support Center and a technician will help you over the telephone. HP specifies in the materials shipped with a - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 5
pièce défectueuse, HP se réserve le droit de vous facturer les coûts de remplacement. Dans le cas d'une pièce CSR, HP supporte l'ensemble des frais le site Web HP (http://www.hp.com/go/selfrepair). Service de garantie "pièces seules" Votre garantie limitée HP peut inclure un service de garantie "pi - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 6
Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten . Wenn Sie Hilfe benötigen, können Sie das HP technische Support Center Customer self repair 6 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 7
CSR-Verfahren zwingend vorgegeben. Wenn Sie den Austausch dieser Teile von HP vornehmen lassen, werden Ihnen die Anfahrt- und Arbeitskosten für diesen Service berechnet. Reparaciones del propio cliente Los productos de HP incluyen muchos componentes que el propio usuario puede reemplazar (Customer - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 8
minimum beperkt kan blijven en de flexibiliteit in het vervangen van defecte onderdelen groter is. Deze onderdelen worden CSR-onderdelen (Customer Self Repair) genoemd. Als HP (of een HP Service Partner) bij de diagnose vaststelt dat de reparatie kan worden uitgevoerd met een CSR-onderdeel, verzendt - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 9
voor meer informatie over het Customer Self Repair programma van HP. Informatie over Service Partners vindt u op de HP website (http://www.hp.com/go/selfrepair). Garantieservice "Parts Only" Het is mogelijk dat de HP garantie alleen de garantieservice "Parts Only" omvat. Volgens de bepalingen - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 10
peças. Segundo os termos do serviço de garantia apenas para peças, a HP fornece as peças de reposição sem cobrar nenhuma taxa. No caso desse serviço, a substituição de peças CSR é obrigatória. Se desejar que a HP substitua essas peças, serão cobradas as despesas de transporte e mão-de-obra do - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 11
Customer self repair 11 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 12
Customer self repair 12 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 13
Customer self repair 13 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 14
Customer self repair 14 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 15
Illustrated parts catalog Storage blade components Item Description 1 FBWC capacitor pack 2 System board 3 FBWC module 4 Enclosure release latch 5 Front panel assembly 6 LED panel 7 Hard drive blank Spare part number 571437- - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 16
optional ist. Diese Teile sind auch für Customer Self Repair ausgelegt. Wenn Sie jedoch den Austausch dieser Teile von HP vornehmen lassen möchten, können bei diesem Service je nach den für Ihr Produkt vorgesehenen Garantiebedingungen zusätzliche Kosten anfallen. 3No: Kein-Einige Teile sind nicht - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 17
ser reparados por el usuario. Para que el usuario haga valer su garantía, HP pone como condición que un proveedor de servicios autorizado realice la sustitución de met de garantievoorwaarden moet het onderdeel door een geautoriseerde Service Partner worden vervangen. Deze onderdelen worden in de ge - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 18
Illustrated parts catalog 18 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 19
presence of hazardous energy circuits or electric shock hazards. Refer all servicing to qualified personnel. WARNING: To reduce the risk of injury from indicates the presence of electric shock hazards. The area contains no user or field serviceable parts. Do not open for any reason. WARNING: To - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 20
and/or the system. However, it may be necessary to leave the storage blade powered up when performing other operations, such as hot-plug installations or troubleshooting. Storage blade preparation To service any internal storage blade component, do the following: 1. Power down the partner server - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 21
the following: o Remove the blank installed above the storage blade. o Remove the half-height device installed above the storage blade. For information about removing a half-height device, see the the half-height device user guide. 4. Remove the storage blade: Removal and replacement procedures 21 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 22
to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. 1. Back up all data on the storage blade. 2. Power down the partner server blade (on page 21). 3. Remove the storage blade (on page 21). Removal and replacement - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 23
removed. 6. Place the hard drives in a static-free environment. When the service procedures are complete, return each hard drive to the bay in the hard 4. Slide the access panel toward the rear of the storage blade. 5. Remove the access panel. Install the access panel WARNING: To reduce the risk of - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 24
and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. To remove the component: 1. Open the hard drive drawer. Removal and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 25
the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. To remove the component: 1. Determine the status of the hard drive from - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 26
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 27
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 28
hard drive drawer and cable spool are not shown for clarity. IMPORTANT: To avoid possible damage to the storage blade, be sure that the FBWC module is fully seated before installing the retaining screw. To replace the component, reverse the removal procedure. Front panel WARNING: To reduce the risk - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 29
the drives and the internal system components to cool before touching them. CAUTION: To prevent damage to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. To remove the component: 1. Power down the partner server - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 30
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 31
cable cover from the hard drive drawer. CAUTION: The pass-through cable is under tension. Hold the end of the cable firmly when removing, and guide the cable back to the coiled position in the chassis. 9. Remove the pass-through board and cable from the hard drive drawer. 10. Remove the - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 32
11. Remove the pass-through cable from the carrier. Removal and replacement procedures 32 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 33
damage to electrical components, properly ground the storage blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 34
cable cover from the hard drive drawer. CAUTION: The pass-through cable is under tension. Hold the end of the cable firmly when removing, and guide the cable back to the coiled position in the chassis. 7. Remove the pass-through board and cable from the hard drive drawer. Removal and replacement - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 35
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 36
a. Top slide assembly b. Bottom slide assembly 8. Remove the slide assemblies from the chassis: Removal and replacement procedures 36 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 37
damage to electrical components, properly ground the server blade before beginning any installation procedure. Improper grounding can cause ESD. CAUTION: Do not operate the storage blade with the access panel open or removed. Operating the storage blade in this manner results in improper airflow and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 38
To remove the component: 1. Back up all data on the storage blade. 2. Power down the partner server blade (on page 21). 3. Remove the storage blade (on page 21). 4. Remove all hard drives ("Hard drive" on page 25). 5. Remove the access panel (on page 23). 6. Remove the hard drive drawer ("Hard - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 39
Front panel components Item Description 1 Product information tag 2 LED panel 3 Hard drive drawer release latch 4 Hard drive drawer handle 5 Storage blade locking lever* * Removing the storage blade from the enclosure removes power from the hard drives. Component identification 39 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 40
drives have reached near-critical temperatures. * The system health LED flashes amber when the storage blade establishes a connection with the enclosure, either immediately after installation or when the storage blade is removed and reinstalled. If the LED continues to flash for more than 2 minutes - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 41
SAS and SATA hard drive bay numbers SAS and SATA hard drive LEDs Item 1 2 Description Fault/UID LED (amber/blue) Online LED (green) SAS and SATA hard drive LED combinations Online/activity LED (green) On, off, or flashing On, off, or flashing Fault/UID LED (amber/blue) Alternating amber and - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 42
as possible. A predictive failure alert has been received for this drive. Replace the drive as soon as possible. The drive is offline, a spare, or not configured as part of an array. Component identification 42 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 43
the iLO 2 user interface • From within HP Insight Diagnostics For more information, see the Management CD in the HP Insight Foundation suite for ProLiant. Array Diagnostic Utility The HP Array Diagnostics Utility is a web-based application that creates a report of all HP storage controllers and disk - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 44
corresponds to a pressure minimum of 70 KPa. † Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Storage blade specifications Specification Height Depth Width Weight (maximum) Weight (no drives installed) Value 5.56 cm (2.19 in) 50.95 cm (20.06 in) 18.16 cm (7.15 in) 5.0 kg (11 - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 45
Acronyms and abbreviations ADU Array Diagnostics Utility CLI Command Line Interface CSR Customer Self Repair FBWC flash-backed write cache HP SIM HP Systems Insight Manager iLO 2 Integrated Lights-Out 2 IML Integrated Management Log SAS serial attached SCSI SATA serial ATA SFF small form-factor SIM - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 46
determining status of 41 health LEDs 40, 41 I illustrated parts catalog 15 installing the access panel 23 Integrated Management Log (IML) 43 L LED panel replacement procedures 19 removing the access panel 23 removing the storage blade 21 S safety considerations 19 safety information 19 SAS drives - HP StorageWorks D2200sb | HP StorageWorks D2200sb PCIe Storage Blade Maintenance - Page 47
system board 30 T tools 19, 43 U UID LED 40 W warnings 20 warranty 4 Index 47
HP StorageWorks D2200sb PCIe Storage Blade
Maintenance and Service Guide
Part Number 611258-001
November 2010 (First Edition)