Addendum HP StorageWorks HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80 Array Controllers Product Version: . For the latest version of this Addendum and other product documentation, visit the StorageWorks web site at http://www.compaq.com/storage/index.html - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 2
© Hewlett-Packard Company, 2000-2005. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 3
HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide, EK-G80CL-RA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 HSG80 Addendum for ACS Solution Software V8 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 4
Troubleshooting Guide, EK-G80TS-SA. C01 ■ SWCC v2.5 documentation (Client software delivered in solutions kits) ■ HP StorageWorks HP StorageWorks Command Console Version 2.5 User Guide, AA- RV1UA -TE ■ HP StorageWorks HP StorageWorks - Windows NT/2000 Additional support required by HSG80 ACS Solution - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 5
solution kit, consisting of hardware, software and firmware, for the HSG60 or HSG80 array controller, also contains the latest version of StorageWorks Command Console (SWCC) software. Figure 1: HSG array controller HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 6
of the Array Controller Software, used with HSG60 and HSG80 controllers, include: ■ Up to 146GB drives in a 1-inch form factor ■ An increased number of maximum supported host connections from 64 to 96 ■ 14 drives on a single SCSI bus ■ 84 total drives behind one controller pair with six fully loaded - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 7
■ SET_DRM ■ SET_REMOTE_COPY_SET_NAME ■ SET_SITE_FAILOVER All other CLI commands described in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide work with either HSG80 or HSG60 array controllers. Layered Software Applications - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 8
retains code patch information to the software. This option is supported on single controller configurations only. ACS V8.8 saves any ■ Since the HSG60 array controller has two SCSI buses, the maximum number of disks supported is 28. The SCSI-2 bus can not be configured split-bus. 8 HSG80 Addendum - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 9
controller has six SCSI buses, the maximum number of disks supported is 84. HSG60 Limitation The predefined HSG60 model provides a set number of controller shelves and drive shelves in a Modular Storage Cabinet and is limited to: ■ MA6000: One Model 2200 controller enclosure and three dual-bus Model - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 10
Disk Drives HSG60 Supported Disk Drives Patches for ACS and a link to the supported disk drives for the HSG60 are located at http://h18006.www1.hp.com/products/storageworks/softwaredrivers/acs/. 10 HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80 Array Controllers
Addendum
HP StorageWorks
HSG80 Addendum for ACS
Solution Software V8.8
Differences Between HSG60 and HSG80
Array Controllers
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AV-RV2MA-TE
This document describes the differences between HSG60 and HSG80 array controllers. For the
latest version of this Addendum and other product documentation, visit the StorageWorks web
site at