- HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 1
Software Command Line Interface Product Version: 8.8-1 Third Edition (March 2005) Part Number: EK-G80CL-RA. C01 This guide provides detailed descriptions of all HP StorageWorks Array Controller Software (ACS) Command Line Interface (CLI) commands and instructions on how to use each command. - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 2
limited warranty statements for such products. Nothing herein should be construed as constituting an additional warranty. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide Third Edition (March 2005) Part Number: EK-G80CL-RA. C01 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 3
Contents About this Guide 29 Overview 30 Intended audience 30 Prerequisites 30 Related documentation 31 Conventions 34 Document conventions 34 Text symbols 34 Equipment symbols 35 Rack stability 37 Getting help 38 HP technical support 38 HP storage website 38 HP authorized reseller 38 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 4
-index 58 Switches 59 OPERATING_SYSTEM=OS_name 59 RESERVATION_STYLE=CONNECTION_BASED (default) RESERVATION_STYLE=HBA_PORT_ID_BASED 60 UNIT_OFFSET=n 60 Examples 62 See Also 62 4 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 5
69 ADD PASSTHROUGH 70 Syntax 70 Parameters 70 passthrough-name 70 scsi-port-target-lun 71 Switches 71 TRANSFER_RATE_REQUESTED 71 Examples 71 See Also 72 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 5 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 6
ADD SNAPSHOT_UNITS 81 Syntax 81 Parameters 81 snapshot-unit 82 storageset-name 82 source-unit 82 Switches 83 USE_PARENT_WWID 83 Example 83 See Also 83 6 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 7
93 PREFERRED_PATH=OTHER_CONTROLLER PREFERRED_PATH=THIS_CONTROLLER NOPREFERRED_PATH (default 93 READ_CACHE (default) NOREAD_CACHE 94 READAHEAD_CACHE (default) NOREADAHEAD_CACHE 94 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 7 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 8
103 Example 103 See Also 104 CLEAR_ERRORS unit-number LOST_DATA 105 Syntax 105 Parameters 105 unit-number 105 Switches 106 Example 106 See Also 106 8 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 9
Switches 118 SIZE=percent SIZE=LARGEST 118 Example 118 See Also 119 DELETE association-set-name 120 Syntax 120 Parameters 120 association-set-name 120 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 9 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 10
Also 126 DELETE remote-copy-set-name 127 Syntax 127 Parameters 127 remote-copy-set-name 127 Switches 127 Examples 128 See Also 128 10 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 11
Example 134 See Also 135 EXIT 136 Syntax 136 Parameters 136 Switches 136 Example 136 HELP 137 Syntax 137 Parameters 137 Switches 137 Example 137 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 11 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 12
Switches 150 Examples 150 MIRROR 151 Syntax 151 Parameters 151 disk-name 151 mirrorset-name 152 Switches 152 COPY=FAST COPY=NORMAL (default 152 12 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 13
162 SPECIAL_FUNCTION_ONE=NOPARTITION 163 TURNSAVEOFF 163 Example 164 See Also 164 RENAME 165 Syntax 165 Parameters 165 old-container-name 165 new-container-name 165 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 13 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 14
173 Parameters 173 controller 173 Switches 173 IGNORE_ERRORS NOIGNORE_ERRORS (default 173 IMMEDIATE_SHUTDOWN NOIMMEDIATE_SHUTDOWN (default 174 Examples 174 See Also 174 14 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 15
=CONNECTION_BASED (default) RESERVATION_STYLE=HBA_PORT_ID_BASED 182 UNIT_OFFSET 183 Example 183 See Also 183 SET controller 184 Syntax 184 Parameter 184 controller 184 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 15 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 16
-3 196 SMART_ERROR_EJECT=SMART ERROR EJECT 196 TERMINAL_PARITY=ODD TERMINAL_PARITY=EVEN NOTERMINAL_PARITY (default 197 TERMINAL_SPEED=baud-rate TERMINAL_SPEED=9600 (default 197 16 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 17
209 SENSOR_1_SETPOINT=nn SENSOR_2_SETPOINT=nn SENSOR_3_SETPOINT=nn SENSOR_x_SETPOINT=35 (default 209 Examples 210 SET ENABLE_MANAGERS 211 Syntax 211 Parameters 211 Switches 211 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 17 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 18
(default) READ_SOURCE=ROUND_ROBIN 218 REMOVE=disk-name 218 REPLACE=disk-name 219 Examples 219 See Also 220 SET MULTIBUS_FAILOVER 221 Syntax 221 Parameters 221 18 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 19
\target-unit-name 232 ERROR_MODE=FAILSAFE ERROR_MODE=NORMAL (default 232 INITIATOR=initiator-unit-name 232 OPERATION_MODE=SYNCHRONOUS (default) OPERATION_MODE=ASYNCHRONOUS 233 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 19 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 20
(default 240 READ_CACHE (default) NOREAD_CACHE 241 READAHEAD_CACHE (default) NOREADAHEAD_CACHE 241 RUN (default) NORUN 242 WRITE_PROTECT NOWRITE_PROTECT (default 242 20 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 21
250 Parameters 250 Switches 250 FULL 250 Example 250 See Also 250 SHOW connection-name 251 Syntax 251 Parameters 251 connection-name 251 Switches 251 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 21 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 22
261 Example 261 See Also 262 SHOW disk-name 263 Syntax 263 Parameters 263 disk-name 263 Switches 263 Example 263 See Also 264 22 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 23
SHOW mirrorset-name 282 Syntax 282 Parameters 282 mirrorset-name 282 Switches 282 Example 283 See Also 283 SHOW MIRRORSETS 284 Syntax 284 Parameters 284 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 23 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 24
FULL 292 Example 292 See Also 292 SHOW remote-copy-set-name 294 Syntax 294 Parameters 294 remote-copy-set-name 294 Switches 294 24 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 25
FULL 301 Example 301 See Also 301 SHOW unit-number 302 Syntax 302 Parameters 302 unit-number 302 Switches 302 Example 303 See Also 303 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 25 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 26
308 Switches 308 Example 308 See Also 309 WWID_ASSIGN storageset LUN_WWID 310 Syntax 310 Parameters 310 Switches 311 Example 311 Glossary 313 Index 339 26 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 27
-name command 300 31 Screen display after issuing the SHOW STRIPESETS command 301 32 Screen display after the SHOW unit-number command is submitted 303 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 27 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 28
for New Containers 90 5 POWEROFF Switch Settings 157 6 SET controller Switches 184 7 EMU Setpoint Temperatures 210 8 SET unit-number Switches for Existing Containers 235 28 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 29
supplemental information about each CLI command. This "About this Guide" sections covers the following topics: ■ Overview, page 30 ■ Conventions, page 34 ■ Rack stability, page 37 ■ Getting help, page 38 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 29 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 30
this Guide Overview This section covers the following topics: ■ Intended audience ■ Prerequisites ■ Related documentation Intended audience This book is intended for administrators who are experienced with the following: ■ HP StorageWorks HSG60 and HSG80 Array Controllers ■ HP StorageWorks Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 31
Controller Software Troubleshooting Guide HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide HP StorageWorks Replacing a Gigabit Link Module (GLM) in an HSG60 or HSG80 Array Controller Installation Instructions HP StorageWorks Replacing DIMMs - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 32
Version 8.8 for Sun Solaris Release Notes HP StorageWorks Command Console Version 2.4 Release Notes HP StorageWorks Command Console Version 2.4 User Guide HP StorageWorks Command Console Version 2.4 Online Help (HSG60 and HSG80) 24. HP StorageWorks HSG80 ACS Solution Software Version 8.8 for - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 33
Guide Table 1: Related Documentation (Continued) Item 29. 30. 31. 32. Document Name HP StorageWorks HSG80 ACS Solution Software Version 8.8 for Windows Release Notes HP StorageWorks Enterprise/Modular Storage RAID Array Fibre Channel Arbitrated Loop Configurations Application Note HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 34
addresses Text symbols The following symbols may be found in the text of this guide. They have the following meanings: WARNING: Text set off in this manner to equipment or data. 34 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 35
be found on hardware for which this guide pertains. They have the following meanings: Any electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of cool before touching. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 36
About this Guide Power supplies or systems marked with these symbols indicate the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. 36 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 37
About this Guide Rack stability Rack stability protects personnel and equipment. WARNING: To reduce the become unstable if more than one rack component is extended for any reason. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 37 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 38
still have a question after reading this guide, contact an HP authorized service provider or access our website: http://www.hp.com. HP technical support Telephone numbers for worldwide technical support are listed on the following HP website: http://www.hp.com/support/. From this website, select the - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 39
Interface (CLI) and details how to use CLI commands. HP StorageWorks Array Controller Software (ACS), Version 8.8-x, uses predefined commands to examples of usage, as well as supplemental information. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 39 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 40
subsystem control, the HP StorageWorks Command Console (SWCC) application is an alternative application for using CLI commands. The HP SWCC replicates most : ■ CLEAR_ERRORS CLI ■ CLEAR_ERRORS controller INVALID_CACHE 40 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 41
failedset commands. The CLI commands that allow you to add and configure physical devices in general are: ■ ADD DISKS ■ ADD PASSTHROUGH ■ CLEAR_ERRORS device-name UNKNOWN HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 41 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 42
disk-name ■ SHOW EMU ■ SHOW PASSTHROUGH The CLI commands that support sparesets and failedsets include: ■ ADD SPARESETS ■ DELETE FAILEDSETS ■ DELETE of existing units. Tip: Refer to the HP StorageWorks HSG Element Manager User Guide for additional details on selective management options. The - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 43
include: ■ ADD MIRRORSETS ■ ADD RAIDSETS ■ ADD STRIPESETS ■ DELETE container-name ■ INITIALIZE ■ LOCATE ■ MIRROR ■ REDUCE ■ REINITIALIZE container-name ■ RENAME ■ SET mirrorset-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 43 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 44
ADD CONCATSETS ■ ADD SNAPSHOT_UNITS ■ DELETE concatset-name ■ LOCATE ■ RENAME ■ RETRY_ERRORS unit-number UNWRITEABLE_DATA ■ SET concatset-name ■ SHOW concatset-name ■ SHOW CONCATSETS 44 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 45
Diagnostic and utility commands perform general controller support functions. The commands that pertain to the diagnostics and utilities include: ■ DIRECTORY ■ RUN ■ SHOW ELEVATION_INFO HP StorageWorks Data Replication Manager commands HP StorageWorks Data Replication Manager (DRM) uses the peer - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 46
mistakes if you are entering similar commands during the configuration process. Table 3 on page 47 lists the keys used to recall and edit commands. 46 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 47
phrase expressed as a verb used to instruct the controller what to do. Commands are represented in this guide in capitalized form. ■ PARAMETER_NAME-The name string. Parameter names are represented in this guide in capitalized form. HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 48
necessary information to support the action of the COMMAND. Note that not all CLI commands require parameters. Parameters are represented in this guide as lowercase, in this guide as capitalized, italicized text. Note: All commands in this guide use courier typeface font. 48 HP StorageWorks HSG60 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 49
the controller use (production), and which controller (top or bottom) To indicate the which one of many HSG controllers and which controller (top or bottom) HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 49 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 50
CLI Command Introduction 50 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 51
■ Switches needed (if any) to modify the command ■ Examples to illustrate the command usage ■ See Also sections to cross-reference to others with similar usage HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 51 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 52
sets cannot be renamed with the RENAME command. If the wrong name is entered, the association set must be deleted and then added again. 52 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 53
CLI Command Descriptions Switches The following switch supports the ADD ASSOCIATIONS command: remote-copy-set-name Also ADD REMOTE_COPY_SETS SHOW ASSOCIATIONS SET association-set-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 53 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 54
Caution: This command can only be executed with host operating systems that support dynamic volume expansion. If the operating system cannot handle one of its no switches associated with this command. 54 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 55
To add STRIPE2 to the concatset C1, enter: SET C1 ADD=STRIPE2 See Also DELETE concatset-name SET concatset-name SHOW CONCATSETS SHOW concatset-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 55 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 56
filled with fictitious connections. Syntax ADD CONNECTIONS connection-name HOST_ID=host-id ADAPTER_ID=adapter-id CONTROLLER=controller PORT=port ADD CONNECTIONS REJECTED_HOST=index 56 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 57
CLI Command Descriptions Parameters The following parameters support the ADD CONNECTIONS command: ■ connection-name ■ HOST_ID ■ ADAPTER_ID ■ by the WWN of the host bus adapter. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 57 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 58
OpenVMS but not Microsoft® Windows® NT® (except during a reboot). To manually add rejected host zero, issue the following command: ADD CONNECTION REJECTED_HOST=0 Note log in again as well. 58 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 59
rejected hosts are re-ordered. Switches The following switches support the ADD CONNECTION command: ■ OPERATING_SYSTEM ■ RESERVATION_STYLE ■ following values are supported: ■ HP ■ IBM ■ NETWARE ■ SGI ■ SNI ■ SUN ■ TRU64_UNIX ■ VMS ■ WINNT ■ AIX_CAMBEX ■ HP_VSA HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 60
offset of 100; port 2 connections can see units 100 through 199. In Multiple-bus Failover mode, the default offset is 0 for all host connections. 60 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 61
SCSI-3, the command console LUN (CCL) is presented as LUN 0 to every connection, superseding any unit assignments. For more information, see the ADD UNITS command. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 61 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 62
=1000-0000-C920-5678 CONTROLLER=THIS PORT=2 RESERVATION_STYLE=HBA_PORT_ID_BASED See Also DELETE connection-name SET connection-name RENAME SHOW connection-name SHOW CONNECTIONS 62 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 63
CONFIG utility. Note: The controller supports a maximum of 84 physical in the subsystem. BA370 enclosures support up to 72 physical devices. disk drives before they are shipped from HP. Failure to destroy the MBR block of HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 64
Leading zeroes can be excluded. Switches The following switches support the ADD DISKS command: ■ TRANSFER_RATE_REQUESTED= ■ TRANSPORTABLE and include the following: ■ ASYNCHRONOUS ■ DEFAULT 64 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 65
HP StorageWorks systems: ■ Specify TRANSPORTABLE to allow disk drives to be moved to non HP StorageWorks moved to only HP StorageWorks environments. The controller the disk. Note: HP recommends that you avoid using DISK40200 4 2 0 TRANSPORTABLE HP StorageWorks HSG60 and HSG80 Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 66
ADD PASSTHROUGH ADD UNITS DELETE container-name INITIALIZE LOCATE SET mirrorset-name SET device-name SET RAIDset-name SHOW DISKS SHOW DEVICES SHOW PASSTHROUGH 66 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 67
container in an intuitive manner. disk-name1 [disk-nameN] Identifies the disk drives making up the mirrorset. A mirrorset can contain one to six disk drives. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 67 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 68
CLI Command Descriptions Switches The following switches support the ADD MIRRORSETS command: ■ COPY ■ POLICY and NOPOLICY ■ READ_SOURCE that equals or exceeds the base member size. 68 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 69
a POLICY=BEST_FIT or POLICY=BEST_PERFORMANCE is selected or a member is manually placed in the mirrorset (see SET mirrorset-name on page 216). SHOW mirrorset-name SHOW MIRRORSETS SHOW STORAGESETS UNMIRROR HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 69 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 70
the CONFIG utility. Note: HP StorageWorks EMA series cabinets support a maximum of 84 physical storage target IDs are available. HP StorageWorks BA370 and RA8000 series enclosures and cabinets support a maximum of 72 physical device SCSI location. 70 HP StorageWorks HSG60 and HSG80 Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 71
Leading zeroes can be excluded. Switches The following switch supports the ADD PASSTHROUGH command: ■ TRANSFER_RATE_REQUESTED TRANSFER_RATE_REQUESTED Specifies the ADD PASSTHROUGH PASS10200 1 2 0 ADD UNIT P4 PASS10200 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 72
CLI Command Descriptions See Also ADD UNITS DELETE container-name LOCATE SET mirrorset-name SET device-name SET RAIDset-name SHOW DISKS SHOW DEVICES SHOW PASSTHROUGH 72 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 73
disk-name3 [disk-nameN] Parameters The following parameters support the ADD RAIDSETS command: ■ RAIDset-name ■ disk-name 1. This is a combined maximum that is limited to no more than 20 RAID 3/5 storagesets in the individual combination. HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 74
Identifies the disks making up the RAIDset. Switches The following switches support the ADD RAIDSETS command: ■ POLICY and NOPOLICY ■ RECONSTRUCT ■ REDUCED on a different port than existing 74 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 75
state until you select either POLICY=BEST_PERFORMANCE or POLICY=BEST_FIT, or manually place a member in the RAIDset. See SET RAIDset-name for -for instance, while creating a new RAIDset. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 75 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 76
initialize the RAIDset again): ADD RAIDSETS RAID6 DISK10300 DISK20400 DISK30200 REDUCED Caution: Data contained on the RAIDset is erased if you reinitialize the RAIDset. 76 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 77
new disk from the failedset, and place it into the active RAIDset. Refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for additional details. See Also ADD UNITS DELETE container-name INITIALIZE SHOW RAIDSETS SHOW RAIDSETS SHOW - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 78
with ACS V8.8-xP. Like all DRM commands, use of this command is heavily restricted. Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application for examples of usage. This command can only be used on the initiator (local) site. The following - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 79
target of the remote copy set. Switches The following switches support the ADD REMOTE_COPY_SETS command: ■ OPERATION_MODE ■ OUTSTANDING_IOS These switches the members of a remote copy set. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 79 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 80
(node) named London, enter: ADD REMOTE_COPY_SETS RCS1 D1 LONDON\D21 ADD ASSOCIATIONS SET controller and REMOTE_COPY=node-name NOREMOTE_COPY SET remote-copy-set-name 80 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 81
snapshot unit can be manually presented to the host. supported in Windows 2000. Syntax ADD SNAPSHOT_UNITS snapshot-unit storageset-name source-unit Parameters The following parameters are required for the ADD SNAPSHOT_UNITS command: ■ snapshot-unit ■ storageset-name ■ source-unit HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 82
■ Writeback cache enabled ■ Non-transportable ■ Must be preferred to one controller or the other (see the PREFERRED_PATH switch of the SET unit-number command). 82 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 83
CLI Command Descriptions Switches The following switch supports the ADD SNAPSHOT_UNITS command: USE_PARENT_WWID Causes the snapshot unit-number DELETE container-name SHOW unit-number HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 83 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 84
storageset members. Syntax ADD SPARESETS disk-name Parameters The following parameter supports the ADD SPARESETS command. disk-name Indicates the name of the DISK30300 DELETE SPARESETS SHOW SPARESETS SHOW STORAGESETS 84 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 85
name a stripeset STRIPEn, where n is a sequentially assigned, unique identifier. This naming convention presents to the user both the type of container and its unique identifier. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 85 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 86
you can initialize the stripeset, you do not need to individually initialize the mirrorset members. See Also ADD UNITS ADD MIRRORSETS DELETE container-name 86 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 87
INITIALIZE SHOW STORAGESETS SHOW STRIPESETS SHOW stripeset-name CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 87 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 88
-name Parameters The following parameters are required for the ADD UNITS command: ■ unit-number ■ container-name These parameters are described in the following paragraphs. 88 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 89
modes that are contained in the controller installation and configuration guide for further information regarding the relationship between unit numbers and LUN number = unit number - offset HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 89 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 90
MAX_WRITE_CACHED_TRANSFER_SIZE MAXIMUM_CACHED_TRANSFER_SIZE PARTITION=partition-number PREFERRED_PATH NOPREFERRED_PATH READ_CACHE NOREAD_CACHE READAHEAD_CACHE NOREADAHEAD_CACHE 90 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 91
to prevent all host connections from accessing the unit. The allowable variables are: ■ ALL ■ A string of connection names separated by commas and enclosed in parentheses. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 91 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 92
blocks to be cached by the controller. The controller does not cache any transfers over the size set. Acceptable block sizes are 0 through 2,048. 92 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 93
. This error message indicates that the assignment of a preferred controller path at the unit level as valid only if operating in Multiple-bus Failover mode. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 93 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 94
instruct "this controller" to bring this unit online. ■ Select PREFERRED_PATH=OTHER_CONTROLLER to instruct improves performance in almost all situations. Therefore, HP recommends that you leave its default setting, READ_CACHE multiple units. 94 HP StorageWorks HSG60 and HSG80 Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 95
. WRITEBACK_CACHE NOWRITEBACK_CACHE Enables or disables the writeback data caching function of the controller. The controller writeback caching feature improves write performance. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 95 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 96
is presented to each host connection as LUN (2 - offset). Offset is a host connection characteristic, specified in the ADD CONNECTIONS (or SET connection-name) command. 96 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 97
LUN (5 - offset). To create unit D7 from a RAIDset named RAID9 and instruct the unit to take advantage of the controller writeback caching feature, enter: ADD RAIDSETS SET connection-name SET unit-number SHOW unit-number HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 98
are no parameters associated with this command. Switches There are no switches associated with this command. Example To clear any message enter: CLEAR_ERRORS CLI 98 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 99
Command Descriptions See Also CLEAR_ERRORS controller INVALID_CACHE CLEAR_ERRORS device-name UNKNOWN CLEAR_ERRORS unit-number LOST_DATA CLEAR_ERRORS unit-number UNWRITEABLE_DATA HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 99 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 100
which controller is to receive the CLEAR_ERRORS INVALID_CACHE command. You must specify THIS_CONTROLLER (the one connected to the CLI maintenance terminal) or OTHER_CONTROLLER. 100 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 101
CLI Command Descriptions data-retention-policy Instructs the controller how to handle writeback cached data: ■ the following command on one line: CLEAR_ERRORS THIS_CONTROLLER INVALID_CACHE NODESTROY_UNFLUSHED_DATA HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 101 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 102
OTHER_CONTROLLER INVALID_CACHE DESTROY_UNFLUSHED_DATA CLEAR_ERRORS CLI CLEAR_ERRORS unit-number LOST_DATA CLEAR_ERRORS device-name UNKNOWN CLEAR_ERRORS unit-number UNWRITEABLE_DATA 102 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 103
keyword UNKNOWN cannot be abbreviated. Parameters The following parameter supports the CLEAR_ERRORS device-name UNKNOWN command: device-name Identifies unknown device named DISK30000, enter: CLEAR_ERRORS DISK30000 UNKNOWN HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 104
CLI Command Descriptions See Also CLEAR_ERRORS CLI CLEAR_ERRORS controller INVALID_CACHE CLEAR_ERRORS unit-number LOST_DATA CLEAR_ERRORS unit-number UNWRITEABLE_DATA 104 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 105
parameter supports the CLEAR_ERRORS LOST_DATA command. unit-number Identifies the unit number on which the lost data error is to be cleared. The unit-number is the same name given to the unit at the time you added it to controller configurations with the ADD UNITS command. HP StorageWorks HSG60 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 106
number D103, enter: CLEAR_ERRORS D103 LOST_DATA CLEAR_ERRORS CLI CLEAR_ERRORS controller INVALID_CACHE CLEAR_ERRORS device-name UNKNOWN CLEAR_ERRORS unit-number UNWRITEABLE_DATA 106 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 107
supports the CLEAR_ERRORS UNWRITEABLE_DATA command: unit-number Identifies the unit having the unwriteable data error. The unit-number is the name given to the unit at the time it was created with the ADD UNITS command. Switches There are no switches associated with this command. HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 108
disk unit D103, enter: CLEAR_ERRORS D103 UNWRITEABLE_DATA CLEAR_ERRORS CLI CLEAR_ERRORS controller INVALID_CACHE CLEAR_ERRORS unit-number LOST_DATA CLEAR_ERRORS device-name UNKNOWN 108 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 109
. Enter this command to ensure all of the old configuration information is removed before a controller module is to be moved from one subsystem to another. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 109 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 110
HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for configuration reset usage in controller replacement instructions for single-controller and dual-redundant subsystems. 110 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 111
command. Example See Also To erase the subsystem configuration information in "this controller," enter: CONFIGURATION RESET CONFIGURATION RESTORE CONFIGURATION SAVE INITIALIZE HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 111 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 112
slot to reset it. Refer to controller replacement procedures for single-controller subsystems in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. Caution: If a disk is moved from one subsystem to another, and it contains configuration - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 113
associated with this command. Example To restore the subsystem configuration into the memory of the controller in a single-controller subsystem, enter: CONFIGURATION RESTORE HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 113 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 114
CLI Command Descriptions See Also CONFIGURATION RESET CONFIGURATION SAVE INITIALIZE 114 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 115
redundant configuration. Syntax CONFIGURATION SAVE Parameters There are no parameters associated with this command. Switches There are no switches associated with this command. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 115 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 116
into the memory of the controller in a single-controller subsystem, enter: CONFIGURATION SAVE CONFIGURATION RESET CONFIGURATION RESTORE INITIALIZE REINITIALIZE container-name 116 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 117
CREATE_PARTITION container-name SIZE=percent Parameters The following parameter supports the CREATE_PARTITION command: container-name Identifies the disk must initialize the container before creating the first partition. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 118
CREATE_PARTITION RAID9 SIZE=LARGEST ADD UNITS D101 RAID9 PARTITION=1 ADD UNITS D102 RAID9 PARTITION=2 ADD UNITS D103 RAID9 PARTITION=3 ADD UNITS D104 RAID9 PARTITION=4 118 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 119
See Also ADD UNITS DELETE unit-number DESTROY_PARTITION SET unit-number SHOW unit-number CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 119 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 120
heavily restricted. Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application for examples of usage. Syntax DELETE association-set-name Parameters The following parameter supports the DELETE command: association-set-name Identifies the name - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 121
deleting the concatset. Syntax DELETE concatset-name Parameters The following parameter supports the DELETE command: concatset-name Identifies the name of the Also DELETE unit-number SET concatset-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 121 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 122
be deleted. Syntax DELETE connection-name Parameters The following parameter supports the DELETE command: connection-name Identifies the name given name given through the ADD CONNECTIONS command. 122 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 123
D7, enter: SET D7 DISABLE_ACCESS_PATH=SERVER4 DELETE SERVER4 See Also ADD CONNECTIONS ADD UNITS SET connection-name SET unit-number SHOW CONNECTIONS SHOW connection-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 123 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 124
its original disks. Syntax DELETE container-name Parameters The following parameter supports the DELETE command: container-name Identifies the container to be associated with this command. 124 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 125
STRIPE1, enter: DELETE STRIPE1 To delete a RAIDset named RAID9, enter: DELETE RAID9 See Also DELETE FAILEDSETS DELETE SPARESETS SHOW STORAGESETS UNMIRROR CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 125 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 126
RAIDsets and mirrorsets because they failed. ■ Manually removed using the SET command (for example, DELETE FAILEDSETS disk-name Parameters The following parameter supports the DELETE FAILEDSETS command: disk-name Identifies the SHOW FAILEDSETS 126 HP StorageWorks HSG60 and HSG80 Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 127
version of the Operations Guide for the HP StorageWorks Data Replication Manager application for supports the DELETE command: remote-copy-set-name Identifies the name given to the remote copy set that is to be deleted. Switches There are no switches associated with this command. HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 128
CLI Command Descriptions Examples To delete RCS1, enter: DELETE RCS1 See Also ADD REMOTE_COPY_SETS SET remote-copy-set-name SHOW REMOTE_COPY_SETS SHOW remote-copy-set-name 128 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 129
controller configuration. Syntax DELETE SPARESETS disk-name Parameters The following parameter supports the DELETE SPARESETS command: disk-name Identifies the disk drive DELETE SPARESETS DISK20300 ADD SPARESETS SHOW SPARESETS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 130
a CLEAR_ERRORS command. Syntax DELETE unit-number Parameters The following parameter supports the DELETE command: unit-number Identifies the unit number to be deleted LOST_DATA CLEAR_ERRORS unit-number UNWRITEABLE_DATA 130 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 131
DELETE container-name DELETE FAILEDSETS DELETE SPARESETS DESTROY_PARTITION CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 131 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 132
name PARTITION=partition-number Parameters The following parameters support the DESTROY_PARTITION command: ■ container-name ■ partition correct partition before submitting the DESTROY_PARTITION command. 132 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 133
number, to delete partition 2, enter: DESTROY_PARTITION RAID9 PARTITION=2 CREATE_PARTITION DELETE unit-number INITIALIZE SHOW DISKS SHOW RAIDSETS SHOW STORAGESETS SHOW STRIPESETS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 133 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 134
DWNGRD FMU VTDPY V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D V88P D Figure 1: Screen display after issuing the DIRECTORY command 134 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 135
Note: In Figure 1 on page 134, note that CHVSN, DSTAT, and DWNGRAD are not user utilities. These utilities are used by HP authorized service providers only. See Also RUN HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 135 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 136
are no parameters associated with this command. Switches There are no switches associated with this command. Example To terminate the CLI program, enter: EXIT 136 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 137
of all available options at that point in the command. For example: SET THIS_CONTROLLER? Prints a list of all legal SET THIS_CONTROLLER commands. Figure 2: Help screen HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 137 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 138
CLI Command Descriptions To list all legal commands pertaining to a specific CLI command: enter the command, type a space, and enter a question mark. For example: SET? 138 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 139
creating a unit from a newly installed disk. ■ Before creating a unit from a newly created RAIDset, stripeset, or mirrorset. ■ To destroy all existing partitions on a container. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 139 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 140
this task. Syntax INITIALIZE container-name Parameters The following parameter supports the INITIALIZE command: container-name Specifies the container to initialize switches are described in the following paragraphs. 140 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 141
used unless there is a compatibility problem with the existing defaults. The geometry switches for the INITIALIZE command are ignored after you create partitions. The geometry switches supplied with the CREATE_PARTITION command are used by the unit. HP StorageWorks HSG60 and HSG80 Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 142
can cause serious performance problems with the subsystem. Refer to the detailed description of chunk size that is contained in the controller installation and configuration guide for information regarding recommended chunk size settings for this application. 142 HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 143
partition on a new disk device. Caution: After an INITIALIZE DISKnnnnn DESTROY_MRB is issued, the command writes data into the data area of the disk device. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 143 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 144
(default) Instructs the controller to supported on single-controller configurations, saves a configuration to a disk or storageset. The configuration can be retrieved later and downloaded onto a replacement controller. It also retains code patches to the ACS software. 144 HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 145
can validate the save configuration usage by issuing the SHOW DEVICE_INFO FMU command. Refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide for additional information under the SHOW DEVICE_INFO FMU command. Note: ACS saves any installed - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 146
: INITIALIZE RAID9 CHUNKSIZE=20 To initialize DISK40400 and preserve the data after it is removed (reduced) from a mirrorset, enter: REDUCE DISK40400 INITIALIZE DISK40400 NODESTROY 146 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 147
ADD MIRRORSETS ADD RAIDSETS ADD STRIPESETS ADD PASSTHROUGH ADD UNITS CONFIGURATION RESET CONFIGURATION RESTORE CONFIGURATION SAVE CREATE_PARTITION MIRROR REINITIALIZE container-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 147 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 148
parameters support the LOCATE command: ■ ALL ■ CANCEL ■ container-name ■ DISKS ■ ptl ■ UNITS ■ unit-number These parameters are described in the following paragraphs. 148 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 149
devices are not currently configured into logical units. unit-number Causes the device fault LEDs on the devices making up the unit-number to flash. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 149 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 150
configured disk devices to flash, enter: LOCATE DISKS To turn off the device fault LEDs that are flashing on all devices, enter: LOCATE CANCEL 150 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 151
Parameters The following parameters support the MIRROR command: ■ disk-name ■ mirrorset-name These parameters are described in the following paragraphs. disk-name Specifies the name of the disk to convert to a one-member mirrorset. The disk must be part of a unit. HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 152
the type of container and its unique identifier. Switches The following switches support the MIRROR command: ■ COPY ■ POLICY and NOPOLICY These switches are from the spareset if a mirrorset member fails. 152 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 153
state until either POLICY=BEST_PERFORMANCE or POLICY=BEST_FIT is selected or a member is manually placed in the mirrorset (see SET mirrorset-name on page 216). Example The SET MIRROR3 MEMBERSHIP=2 SET MIRROR3 REPLACE=DISK10200 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 154
CLI Command Descriptions See Also ADD MIRRORSETS INITIALIZE REDUCE SHOW MIRRORSETS UNMIRROR 154 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 155
BATTERY_OFF (default) Instructs the external cache battery (ECB) charger to turn off or remain on. ■ Specify BATTERY_ON to keep the ECB charger on after the POWEROFF command is issued. ■ Specify BATTERY_OFF to turn off the ECB charger after the POWEROFF command is issued. HP StorageWorks HSG60 and - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 156
cease flashing if BATTERY_OFF is used. OVERRIDE_BAD_FLUSH NO_OVERRIDE_BAD_FLUSH (default) Instructs the controller to either power off the enclosure or remain on the unwritten data is recovered. 156 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 157
remain on. Example To power off the disk units and the enclosure in 10 seconds (BATTERY_OFF and NO_OVERRIDE_BAD_FLUSH are the defaults), enter: POWEROFF SECONDS=10 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 157 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 158
disks. ■ Decreases the nominal number of members of the mirrorsets by the number of disks removed from the mirrorsets. ■ Re-establishes I/O to the unit. 158 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 159
parameter supports the REDUCE command: disk-name1 disk-name2 disk-name3... Specifies the names of the disk or disks to be removed from the mirrorset or mirrorsets. Multiple members can be removed with the REDUCE command. Switches There are no switches associated with this command. HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 160
STRIPE1 MIRR3 mirrorset DISK30300 STRIPE1 Figure 4: Removing disks from a mirrorset See Also ADD MIRRORSETS MIRROR RUN (CLONE utility) SET mirrorset-name SHOW MIRRORSETS 160 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 161
command. Switches The following switches support the REINITIALIZE container-name command: ■ SPECIAL_FUNCTION_ONE=INFO ■ SPECIAL_FUNCTION_ONE=PARTITION ■ SPECIAL_FUNCTION_ONE=NOPARTITION ■ TURNSAVEOFF These switches are described in the following paragraphs. HP StorageWorks HSG60 and HSG80 Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 162
in dual-redundant controller configurations causes the container ownership to move to the controller from which the REINITIALIZE container-name command was not issued. 162 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 163
under older ACS versions. This switch does not become effective if a storage container is moved or placed under a controller running ACS versions prior to V8.8. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 163 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 164
version Affected: Yes, mdata_version (vsi): 11 Figure 5: Screen display after issuing the REINITIALIZE SPECIAL_FUNCTION_ONE=INFO command See Also CONFIGURATION SAVE INITIALIZE 164 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 165
RENAME old-container-name new-container-name Parameters The following parameters support the RENAME command: ■ old-container-name ■ new-container-name of DISK10000 to MYDISK, enter: RENAME DISK10000 MYDISK HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 165 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 166
CLI Command Descriptions To change the name of host connection !NEWCON03 to server2, enter: RENAME !NEWCON03 SERVER2 166 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 167
RESTART controller Parameters The following parameter supports the RESTART command: controller Identifies which . Switches The following switches support the RESTART controller command: the cache. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 168
instruct the controller not to restart before all data is flushed from writeback cache to the devices. Examples To restart "this controller," enter: RESTART THIS_CONTROLLER To restart "other controller," enter: RESTART OTHER_CONTROLLER See Also SELFTEST SHUTDOWN controller 168 HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 169
. Syntax RETRY_ERRORS unit-number UNWRITEABLE_DATA Parameter The following parameter supports the RETRY_ERRORS command: unit-number Identifies the unit number RETRY_ERRORS D103 UNWRITEABLE_DATA CLEAR_ERRORS unit-number UNWRITEABLE_DATA HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 170
program-name Parameter The following parameter supports the RUN command: program-name is not a user utility. This utility is used by HP authorized service providers only. ■ CLCP-A utility used to load updated 170 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 171
utility is used by HP authorized service providers only. ■ DWNGRD-This is not a user utility. This utility is used by HP authorized service providers only. ■ Refer to the controller troubleshooting guide for more information regarding these utilities. HP StorageWorks HSG60 and HSG80 Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 172
CLI Command Descriptions Switches There are no switches associated with this command. Example To start the DILX diagnostic program, enter: RUN DILX See Also DIRECTORY 172 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 173
The following parameter supports the SELFTEST command: Instructs the controller how to respond to writeback cache errors. Caution: The IGNORE_ERRORS switch can cause data to remain in writeback cache. Do not perform any hardware changes until the controller flushes the cache. HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 174
Specify NOIGNORE_ERRORS to instruct the controller Instructs the controller on whether to flush the writeback cache. Caution: The IMMEDIATE_SHUTDOWN switch instructs IMMEDIATE_SHUTDOWN to instruct the controller ■ Select NOIMMEDIATE_SHUTDOWN to instruct the controller to flush HP StorageWorks HSG60 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 175
heavily restricted. Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application for examples of usage. Syntax SET switches support the SET association-set-name command: ■ ADD ■ FAIL_ALL and NOFAIL_ALL ■ LOG_UNIT and NOLOG_UNIT HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 176
read the log disk and can send the write commands, in order, to the target, which brings the target into congruency with the initiator. 176 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 177
association set start to log (or not) independently. - The order of all asynchronous write operations across all members of the association set is not preserved. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 177 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 178
to association set AS3, enter: SET AS3 ADD=RCS2 SET AS3 ADD=RCS4 See Also ADD ASSOCIATIONS ADD REMOTE_COPY_SETS SET remote-copy-set-name 178 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 179
command only with host operating systems that can support dynamic volume expansion. This command is not supported on IBM AIX and Novell Netware operating systems in remote copy sets. SET concatset-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 179 Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 180
name of the concatset to be expanded. Switches The following switch supports the SET concatset-name command: ADD=storage-set-name Concatenates the ADD CONCATSETS DELETE concatset-name SHOW CONCATSETS 180 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 181
The following switches support the SET connection-name command: ■ OPERATING_SYSTEM ■ RESERVATION_STYLE ■ UNIT_OFFSET These switches are described in the following paragraphs. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 181 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 182
kit to determine which value should be used. The following values are supported: ■ HP ■ IBM ■ NETWARE ■ SGI ■ SNI ■ SUN ■ TRU64_UNIX ■ those paths that are explicitly reserved. 182 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 183
unit is known internally to the controllers. Example set !newcon31 operating_system=vms unit_offset=20 See Also ADD CONNECTIONS SHOW CONNECTIONS DELETE connection-name RENAME HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 183 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 184
6: SET controller Switches Switch ALLOCATION_CLASS CACHE_FLUSH_TIMER=n COMMAND_CONSOLE_LUN NOCOMMAND_CONSOLE_LUN Value 0-4,294,967,295, 0 (default) 1-65,535, 10 (default) None 184 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 185
defaults: port 1 is 71 and port 2 is 72 None None 1-16 characters None Disable Enable None Disable Enable Odd or even, no terminal parity (default) HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 185 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 186
disables the command console LUN (CCL), a communication LUN used to initially setup SWCC. If changed, the new setting for this switch takes effect immediately. 186 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 187
of the lock. DEFAULT_ACCESS=ENABLE (default) DEFAULT_ACCESS=DISABLE Specifies whether newly added units automatically allow connections between host computers and the controller. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 187 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 188
HP StorageWorks HSG Element Manager and HP StorageWorks Command Console disable all connections for units created through their respective programs, creating new units through the CLI requires you to manually mounting results occur. 188 HP StorageWorks HSG60 and HSG80 Array Controller and - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 189
in writeback cache is flushed if this switch is entered from Mirrored mode. This switch disables mirrored writeback cache on both controllers. Therefore, this switch HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 189 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 190
cluster of nodes has units with persistent reservations on a unit, you must invoke the FAKE_PR switch against a unit for each different cluster or node. 190 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 191
a unique 64-bit number, consisting of 16 hexidecimal (HEX) digits. Each HP StorageWorks Fibre Channel enclosure is assigned a node ID, which the controller pair in port 1, plus 2 for port 2). HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 191 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 192
. If the node ID is entered, both controllers assume the correct port IDs automatically. Figure 6 on page 193 shows the location of the sticker. 192 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 193
-PA are 71 for port 1 and 72 for port 2. If the controller memory is wiped out, the AL-PA for both ports defaults to 69. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 193 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 194
either remote copy switch causes the controller to restart. No other switch can be specified in the same command with the remote copy switches. 194 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 195
their fairness algorithm. For detailed information on fairness algorithms, refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 195 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 196
disk drive SMART attributes support HP standards. SMART attributes events are only reported as recovered errors and will be reported to the host during normal I/O operations. 196 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 197
. Caution: Setting UPS=NODE_ONLY or UPS=DATACENTER_WIDE without having a UPS or similar backup system in place can result in data loss if power is interrupted. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 197 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 198
or building (not just the subsystem) is supported by a UPS. If DATACENTER_WIDE is specified, the of the cache batteries. ■ Specify NOUPS to instruct the controller to perform regular cache battery checks and the same name. 198 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 199
Console LUN is lun 0 (IDENTIFIER = 99) Host Connection Table is NOT locked Smart Error Eject Disabled Figure 7: Screen display showing the smart error eject setting HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 199 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 200
unflushed data in cache CACHE_FLUSH_TIMER = DEFAULT (10 seconds) Mirrored Cache: 256 megabyte write cache, version 0022 Cache is GOOD No unflushed data in cache 200 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 201
controller required Restart of this controller required Restart of the other controller required Figure 8: Sample screen display showing how to disable the SCSI fairness setting HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 201 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 202
screen display showing how to enable the SMART error drive eject setting See Also RESTART controller SET MULTIBUS_FAILOVER SHOW controller SHUTDOWN controller SHOW controller 202 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 203
for HP StorageWorks RA8000 series cabinets) ■ TRANSFER_RATE_REQUESTED=5MHZ Specifies the maximum data transfer rate for the controller to use in communicating with the device. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 203 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 204
Transportable disks can be moved to a non HP StorageWorks environment with their data intact. ■ If you NOTRANSPORTABLE, you should initialize the disk. ■ HP recommends that you avoid specifying TRANSPORTABLE unless transportability 204 HP StorageWorks HSG60 and HSG80 Array Controller and - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 205
See Also To set DISK10300 to transportable, enter: SET DISK10300 TRANSPORTABLE ADD DISKS SHOW DEVICES SHOW DISKS CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 205 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 206
host2 to issue CLI commands, enter: SET DISABLE_MANAGERS=host1,host2 To revoke the ability of all hosts, except host1, to issue CLI commands, enter: 206 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 207
the same functionality, without the restriction of using the maintenance port is by entering: SET DISABLE_MANAGERS=host2,host3,host4,host5... SET ENABLE_MANAGERS SHOW MANAGERS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 207 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 208
slave EMU settings. The EMU within the primary enclosure instructs the EMUs within the other enclosures to operate at the this command. Switches The following switches support the SET EMU command: ■ ALARM condition. 208 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 209
control the fan speed for the fans in all connected enclosures. The EMU instructs the fans to operate at high speed if any of the temperature setpoints page 210 for additional information on setpoints. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 209 Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 210
2 to 34°C: SET EMU SENSOR_2_SETPOINT=34 This example shows how to set the EMU fan to operate at high speed: SET EMU FANSPEED=HIGH 210 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 211
Examples To accept only control commands from host connections !NEWCON00 and !NEWCON01, enter: SET ENABLE_MANAGERS=!NEWCON00,!NEWCON01 See Also SET DISABLE_MANAGERS SHOW MANAGERS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 211 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 212
following switch supports the SET FAILEDSET Specify AUTOSPARE to instruct the controller to automatically instruct the controller to leave devices physically replaced in the failedset. The device, though replaced, remains in the failedset until it is manually HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 213
To enable the automatic spare feature, enter: SET FAILEDSET AUTOSPARE To disable the automatic spare feature, enter: SET FAILEDSET NOAUTOSPARE DELETE FAILEDSETS SHOW FAILEDSETS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 213 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 214
associated with this command. Switches The following switch supports the SET FAILOVER COPY=controller command: COPY=controller Identifies configuration information restarts after the command is executed. 214 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 215
the configuration information from "this controller" to "other controller," enter: SET FAILOVER COPY=THIS_CONTROLLER SET MULTIBUS_FAILOVER SET NOFAILOVER SET NOMULTIBUS_FAILOVER HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 215 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 216
it was created with the ADD MIRRORSETS command. Switches The following switches support the SET mirrorset-name command: ■ COPY ■ MEMBERSHIP ■ POLICY and the storageset disk drives. 216 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 217
initialized). If there is more than one disk drive in the spareset that meet the criteria, the controller selects a disk drive with the best performance. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 217 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 218
BEST_PERFORMANCE is selected, or a member is manually placed in the mirrorset. READ_SOURCE=disk-name members for each read request. REMOVE=disk-name Instructs the controller to remove a member from an . 218 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 219
all the blocks for the normalizing member are the same. REPLACE=disk-name Instructs the controller to add a disk member to an existing mirrorset if the following fit, enter: SET MIRR1 POLICY=BEST_FIT HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 219 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 220
and immediately begin the copy operation onto DISK 30200, enter: SET MIRR1 REPLACE=DISK30200 ADD MIRRORSETS MIRROR REDUCE SHOW MIRRORSETS SHOW mirrorset-name UNMIRROR 220 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 221
associated with this command. Switches The following switch supports the SET MULTIBUS_FAILOVER command: COPY=controller Identifies which controller parameter overwrites the information on the companion controller. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 221 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 222
the following command after setting multiple bus failover: SET D100 PREFERRED_PATH=THIS_CONTROLLER SET D101 PREFERRED_PATH=OTHER_CONTROLLER SET NOFAILOVER SET NOMULTIBUS_FAILOVER 222 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 223
because the sharing of devices is not supported by single controller configurations. HP recommends that both controllers be present while this Parameters There are no parameters associated with this command. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 223 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 224
supports the SET NOFAILOVER command: DESTROY_UNFLUSHABLE_DATA NODESTROY_UNFLUSHABLE_DATA (default) Instructs failed controller is replaced and placed into service, the writeback cache data is flushed to configuration, enter: SET NOFAILOVER 224 HP StorageWorks HSG60 and HSG80 Array Controller and - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 225
See Also SET MULTIBUS_FAILOVER SET NOMULTIBUS_FAILOVER CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 225 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 226
CLI Command Descriptions SET NOMULTIBUS_FAILOVER See SET NOFAILOVER on page 223. 226 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 227
to identify the RAIDset as a host-addressable unit. Switches The following switches support the SET RAIDset-name command: ■ POLICY and NOPOLICY ■ RECONSTRUCT ■ REMOVE to use if a member within the RAIDset fails. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 227 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 228
POLICY=BEST_FIT is selected, or a member is manually replaced in the mirrorset. RECONSTRUCT=FAST RECONSTRUCT=NORMAL reduced during the reconstruction. REMOVE=disk-name Instructs the controller to remove a member from specified. 228 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 229
the REPLACE=disk-name switch for information on manually replacing a RAIDset member. See the POLICY if you use the REMOVE switch. REPLACE=disk-name Instructs the controller to add a disk member to an existing SET RAID9 REPLACE=DISK20100 HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 230
CLI Command Descriptions See Also ADD RAIDSETS SHOW RAIDSETS SHOW raidset-name 230 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 231
-addressable unit. Switches The following switches support the SET remote-copy-set-name command: ■ ADD ■ ERROR_MODE ■ INITIATOR ■ OPERATION_MODE ■ OUTSTANDING_IOS ■ REMOVE HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 231 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 232
restricted to only site failover conditions. Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application for examples of usage. 232 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 233
the REMOTE_COPY switch of the SET controller command. Target-unit-name is the name of the unit to be removed from the remote copy set. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 233 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 234
SET RCS7 OPERATION_MODE=SYNCHRONOUS SET RCS7 OPERATION_MODE=ASYNCHRONOUS SET RCS7 OUTSTANDING_IOS=240 See Also ADD REMOTE_COPY_SETS SHOW REMOTE_COPY_SETS SHOW remote-copy-set-name 234 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 235
Containers Container Type RAIDset Stripeset Mirrorset N0Transportable Disk Transportable Disk Switch ENABLE_ACCESS_PATH DISABLE_ACCESS_PATH FAKE_PR IDENTIFIER NOIDENTIFIER HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 235 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 236
PREFERRED_PATH NOPREFERRED_PATH READ_CACHE NOREAD_CACHE READAHEAD_CACHE NOREADAHEAD_CACHE RUN NORUN WRITE_PROTECT NOWRITE_PROTECT WRITEBACK_CACHE NOWRITEBACK_CACHE 236 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 237
host may reset persistent reservations against all of its units in the storage system. After successful communication, the host recreates persistent reservations that were lost. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 237 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 238
with a Unit Attention and ASC and ASCQ of 04_03, signifying that manual invention is required. Note: This switch is especially pertinent for Tru64 UNIX of partitioned containers. 238 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 239
block sizes are 0 through 2048. The MAXIMUM_CACHED_TRANSFER_SIZE switch affects both read and writeback cache if set on a controller that has read and writeback caching. The HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 239 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 240
=OTHER_CONTROLLER to instruct the "other controller" to bring the units online. Note: All partitions on a container must be addressed through the same controller. If you set PREFERRED_PATH for one partition, all partitions on that container inherit the same path. 240 HP StorageWorks HSG60 and - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 241
module. Read caching improves performance in almost all situations. Therefore, HP recommends that you leave its default setting, READ_CACHE, enabled. However, requests, select NOREADAHEAD_CACHE for the unit. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 241 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 242
allow the host to write data to the unit. This allows the controller to overwrite existing data. NOWRITE_PROTECT is the default for transportable disks. 242 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 243
, enter: SET D102 WRITE_PROTECT NOREAD_CACHE To allow only a host connection named Roger1 to access unit D0, enter: SET D0 DISABLE_ACCESS_PATH=ALL SET D0 ENABLE_ACCESS_PATH=ROGER1 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 243 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 244
blocks Geometry (C/H/S): ( 87 / 10 / 19 ) NOHOST_REDUNDANT Figure 10: Preventing the redirection of hosts to a redundant unit copy See Also ADD UNITS SHOW unit-number 244 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 245
associated with this command. Switches The following switch supports the SHOW ASSOCIATIONS command: FULL Provides additional details ADD ASSOCIATIONS SET association-set-name SHOW association-set-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 245 Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 246
Association Uses Used by A1 association RCS1 RCS2 RCS3 Switches: NOFAIL_ALL NOORDER_ALL Figure 12: Screen display after issuing the SHOW association-set-name command 246 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 247
See Also ADD ASSOCIATIONS SET association-set-name SHOW ASSOCIATIONS CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 247 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 248
D1 DISK30400 State: NORMAL DISK10300 (member 0) is NORMAL DISK30400 (member 1) is NORMAL Size: 35538354 blocks Screen display after issuing the SHOW concatset-name command 248 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 249
See Also ADD CONCATSETS SET concatset-name SHOW CONCATSETS CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 249 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 250
parameters associated with this command. Switches The following switch supports the SHOW CONCATSETS command: FULL Provides additional details regarding CONCATSETS SET concatset-name SHOW concatset-name 250 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 251
-C922-556D Port Address Status 1 011000 OL this ADAPTER_ID=1000-0000-C922-556D Offset 0 Figure 14: Screen display after issuing the SHOW connection-name command HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 251 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 252
CLI Command Descriptions See Also ADD CONNECTIONS DELETE connection-name RENAME SET connection-name 252 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 253
The following switch supports the SHOW CONNECTIONS command: FULL Displays the rejected hosts, with an index, and a summary of allowed, used, free, and rejected connections. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 253 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 254
Maximum Allowed Connections = 96 Used Connections = 3 Free Connections = 0 Rejected Connections = 3 Figure 15: Screen display after issuing the SHOW CONNECTIONS FULL command 254 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 255
See Also ADD CONNECTIONS DELETE connection-name RENAME SET connection-name SHOW connection-name CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 255 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 256
terminal) or OTHER_CONTROLLER. Switches The following switch supports the SHOW controller command: FULL Provides additional details regarding the controller configuration. 256 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 257
: 25059 Configuration backup disabled Unit Default access enabled SCSI Fairness Disabled Vendor ID: DEC Figure 16: Screen display after issuing the SHOW controller FULL command HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 257 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 258
CLI Command Descriptions See Also RESTART controller SET controller SET MULTIBUS_FAILOVER SHUTDOWN controller 258 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 259
associated with this command. Switches The following switch supports the SHOW DEVICES command: FULL Provides additional details SPARESET Figure 17: Screen display after issuing the SHOW DEVICES command HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 259 Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 260
CLI Command Descriptions See Also SHOW DISKS SHOW FAILEDSETS SHOW MIRRORSETS SHOW RAIDSETS SHOW SPARESETS SHOW STRIPESETS SHOW unit-number 260 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 261
associated with this command. Switches The following switch supports the SHOW DISKS command: FULL Provides additional details regarding Figure 18: Screen display after issuing the SHOW DISKS command HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 261 Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 262
CLI Command Descriptions See Also ADD DISKS DELETE container-name SET device-name SHOW DEVICES 262 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 263
: NOTRANSPORTABLE TRANSFER_RATE_REQUESTED=20MHZ(synchronous 20.00 MHZ negotiated) Size: 71114623 blocks Figure 19: Screen display after issuing the SHOW disk-name command HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 263 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 264
CLI Command Descriptions See Also ADD DISKS DELETE container-name SET device-name SHOW DISKS 264 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 265
HP service providers because its report provides a complete listing of controller configuration information that is elevated and transferred to support SHOW unit-number (with the FULL switch) HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 265 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 266
support calls to an HP support representative, issue the following commands and capture subsequent screen displays from each controller at the time a controller problem the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide. 266 HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 267
are no switches associated with this command. Examples The following pages show an example of the report generated after the SHOW ELEVATIONS_INFO command is submitted. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 267 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 268
of all remote copy sets in full (SHOW REMOTE FULL). No REMOTE_COPY_SETS Information of all association sets in full (SHOW ASSOCIATION FULL No ASSOCIATIONS 268 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 269
vsilbnsiz 17769177, vsicontsiz 0 mdatav 11, nodest 0, prev_online 0, size_val 1, id0_gd 0, id1_gd 0, save_c 0, parted 1, sc-dis 0 fe_directory[0]=C01FA100, fe_directory[1]=C0FFCB80 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 269 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 270
17769177, vsicontsiz 0 mdatav 11, nodest 0, prev_online 0, size_val 1, id0_gd 0, id1_gd 0, save_c 0, parted 0, sc-dis 0 fe_directory[0]=C01FA100, fe_directory[1]=C0FFCB80 270 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 271
AD009322C5 A019 Size: 17773500 blocks V- 11 Configuration NOT being backed up on this container Logdisk for this controller TOP logdisk 5 0 0 Logdisk for other controller HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 271 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 272
) 31984128 D140 5 10661371 ( 5458.62 MB) 425645504 D10 10661371 ( 5458.62 MB) 42645504 D150 646 ( 0.33 MB) 53306880 646 ( 0.33 MB) 53306880 272 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 273
READ_CACHE Access: ALL State: ONLINE to the other controller PREFERRED_PATH = OTHER_CONTROLLER Size: 14215163 blocks Geometry (C/H/S): ( 4206 / 20 / 169 ) NOHOST_REDUNDANT HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 273 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 274
= 32 ONLINE to the other controller PREFERRED_PATH = OTHER_CONTROLLER Size: 10661371 blocks Geometry (C/H/S): ( 3155 / 20 / 169 ) NOHOST_REDUNDANT 274 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 275
RUN NOWRITE_PROTECT REARDE_ACDAACHHEEAD_CACHE WRITEBACK_CACHE READAHEAD_CACHE WRITEBACK_CACHE MAX_READ_CACHED_TRANSFER_SIZE = 32 MAX_WRITE_CACHED_TRANSFER_SIZE = 32 Access: ALL HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 275 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 276
32 Access: ALL State: ONLINE to this controller Not reserved PREFERRED_PATH = THIS_CONTROLLER Size: 10661371 blocks Geometry (C/H/S): ( 3155 / 20 / 169 ) NOHOST_REDUNDANT 276 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 277
Parameters There are no parameters associated with this command. Switches The following switch supports the SHOW EMU command: FULL Provides additional details regarding the EMU. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 277 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 278
FAILEDSET failedset DISK10000 Switches: NOAUTOSPARE Figure 20: Screen display after issuing the SHOW FAILEDSET command See Also DELETE FAILEDSETS SET FAILEDSET SHOW SPARESETS 278 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 279
display a list of units associated with IDs, enter: SHOW ID Unit ID ---- --- D0 12 D3 9 D7 24 D25 90 D123 1 See Also SET unit-number HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 279 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 280
-C925-0096 ADAPTER_ID=1000-0000-C925-0096 !NEWCON17 WINNT OTHER 1 011300 0 HOST_ID=2000-0000-C923-2CD2 ADAPTER_ID=1000-0000-C923-2CD2 280 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 281
See Also SET DISABLE_MANAGERS SET ENABLE_MANAGERS CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 281 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 282
parameter supports the SHOW command: mirrorset-name Specifies the name of the mirrorset to be displayed. Switches There are no switches associated with this command. 282 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 283
Size: 71114623 blocks Figure 21: Screen display after issuing the SHOW mirrorset-name command See Also ADD MIRRORSETS DELETE container-name SHOW MIRRORSETS SHOW STRIPESETS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 283 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 284
parameters associated with this command. Switches The following switch supports the SHOW MIRRORSETS command: FULL Provides additional details regarding Screen display after issuing the SHOW MIRRORSETS command 284 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 285
See Also ADD MIRRORSETS DELETE container-name SHOW mirrorset-name SHOW STRIPESETS CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 285 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 286
switch supports the SHOW PASSTHROUGH command: FULL Provides additional details regarding subsystem passthrough devices. See Also ADD PASSTHROUGH DELETE container-name 286 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 287
following parameter supports the SHOW command: raidset-name Specifies the name of the RAIDset to be displayed. Switches There are no switches associated with this command. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 287 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 288
blocks Figure 23: Screen display after issuing the SHOW raidset-name command See Also ADD RAIDSETS DELETE container-name SET RAIDset-name SHOW RAIDSETS 288 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 289
no parameters associated with this command. Switches The following switches support the SHOW RAIDSETS command: ■ FULL ■ SPECIAL_FUNCTION_ONE These switches checks in the HP StorageWorks Array Controller and Array Controller Software Maintenance and Service Guide. HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 290
CONTROLLER GOOD GOOD Used by D11 D12 D13 D2 D3 D4 D21 D31 Figure 25: Screen display after issuing the SHOW RAIDSETS SPECIAL_FUNCTION_ONE command 290 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 291
See Also ADD RAIDSETS DELETE container-name SET RAIDset-name SHOW raidset-name CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 291 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 292
parameters associated with this command. Switches The following switch supports the SHOW REMOTE_COPY_SETS command: FULL Provides additional details ADD REMOTE_COPY_SETS DELETE remote-copy-set-name 292 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 293
SET remote-copy-set-name SHOW ASSOCIATIONS SHOW controller SHOW remote-copy-set-name CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 293 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 294
supports the SHOW command: remote-copy-set-name Specifies the name of the remote copy set to be displayed. Switches There are no switches associated with this command. 294 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 295
-3889-05C0 Switches: OPERATION_MODE = SYNCHRONOUS ERROR_MODE = NORMAL FAILOVER_MODE = MANUAL OUTSTANDING_IOS = 200 Initiator (INT\D1) state: ONLINE to this -name SHOW ASSOCIATIONS SHOW controller SHOW REMOTE_COPY_SETS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 296
Uses Used by SPARESET spareset DISK30400 Figure 28: Screen display after issuing the SHOW SPARESETS command See Also ADD SPARESETS DELETE SPARESETS SHOW FAILEDSETS 296 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 297
There are no parameters associated with this command. Switches The following switch supports the SHOW STORAGESETS command: FULL Provides additional details regarding subsystem storagesets. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 297 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 298
the SHOW STORAGESETS command See Also ADD DISKS ADD MIRRORSETS ADD RAIDSETS DELETE container-name SHOW DISKS SHOW MIRRORSETS SHOW RAIDSETS SHOW unit-number 298 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 299
parameter supports the SHOW command: stripeset-name Specifies the name of the stripeset to be displayed. Switches There are no switches associated with this command. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 299 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 300
NORMAL Size: 142229246 blocks Figure 30: Screen display after issuing the SHOW stripeset-name command See Also ADD STRIPESETS DELETE container-name SHOW STRIPESETS 300 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 301
associated with this command. Switches The following switch supports the SHOW STRIPESETS command: FULL Provides additional details regarding ADD STRIPESETS DELETE container-name SHOW stripeset-name HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 301 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 302
Parameters The following parameter supports the SHOW command: unit-number Specifies the unit to be displayed. Switches There are no switches associated with this command. 302 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 303
/ 10 / 19 ) NOHOST_REDUNDANT Figure 32: Screen display after the SHOW unit-number command is submitted See Also ADD UNITS DELETE unit-number SET unit-number HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 303 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 304
SHUTDOWN controller Parameter The following parameter supports the SHUTDOWN command: controller Identifies the . Switches The following switches support the SHUTDOWN controller command: 304 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 305
instruct the controller to shut down even if the data within writeback cache cannot be written to the devices. ■ Specify NOIGNORE_ERRORS to instruct IMMEDIATE_SHUTDOWN NOIMMEDIATE_SHUTDOWN (default) Instructs the controller when to shut RESTART controller SELFTEST HP StorageWorks HSG60 and HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 306
restricted. Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application for an explanation and examples of -node-name\remote-copy-set-name Parameters The following parameter supports the SITE_FAILOVER command: remote-node-name remote-copy-set-name - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 307
There are no switches associated with this command. Examples Refer to the latest version of the Operations Guide for the HP StorageWorks Data Replication Manager application. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 307 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 308
supports the UNMIRROR command: disk-name Specifies the name of the normal mirrorset member to be removed from a mirror storageset. Switches There are no switches associated with this command. Example To convert DISK10300 back to a single device, enter: UNMIRROR DISK10300 308 HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 309
See Also ADD MIRRORSETS MIRROR REDUCE RUN SET mirrorset-name CLI Command Descriptions HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 309 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 310
unit. ■ ACS V8.8-xP is the operating firmware on your subsystem. Syntax WWID_ASSIGN storageset LUN_WWID= Parameters There are no parameters associated with this command. 310 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 311
the xxxx-xxxx-xxxx-xxxx-xxxx format. Note: After you assign the WWID, 6000-1FE1 is added to the beginning of the LUN WWID specified. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 311 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 312
CLI Command Descriptions 312 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 313
glossary Glossary This glossary defines terms used in this guide or related to this product and is not a comprehensive See AL_PA array controller See controller Array Controller Software See ACS HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 313 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 314
on the controller's policy processor. bit A single binary digit having a value of either 0 or 1. A bit is the smallest unit of data a computer can process. 314 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 315
own action. For example, a machine routine whose first few instructions are enough to bring the rest of the routine into the unit. The power entry device for HP StorageWorks racks (cabinets). The CDU provides . HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 316
storage devices organized in a storage array. The HS-series of the HP StorageWorks family of controllers are all array controllers. copying A state in which member. CSR Control and Status Register. 316 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 317
A generic reference to large subsystem racks, such as those in which HP StorageWorks products can be mounted. data striping The process of segmenting logically sequential . DIMM Dual Inline Memory Module. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 317 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 318
circuit containing two serial, asynchronous transceiver circuits. DWZZA An HP StorageWorks SCSI-bus-signal converter used to connect 8-bit single-ended See also SCSI bus signal converter. 318 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 319
Glossary DWZZB An HP StorageWorks SCSI bus signal converter used to connect a variety of 16-bit the newly-restored controller in a dual-redundant controller configuration. See also failover. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 319 Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 320
RAIDsets due to a failure or a manual removal. Disk drives in the failedset Services-1. FC-GS-2 Fibre Channel Generic Services-2. FC-IG Fibre Channel Implementation Guide. FC-LE Fibre Channel Link Encapsulation (ISO 8802.2). FCP The mapping of SCSI-3 operations to Fibre Channel. 320 HP StorageWorks - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 321
unit used to transfer information in Fibre Channel. FRU Field Replaceable Unit. A hardware component that can be replaced at a customer location by HP authorized service providers. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 321 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 322
host support Also called noncooperating host support. HIPPI-FC Fibre Channel over HIPPI. host The primary or controlling computer to which a storage subsystem is attached. 322 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 323
during this process. See also pluggable. HP StorageWorks An HP brand name for a family of modular controllers in HP StorageWorks enclosures to form storage subsystems. HP StorageWorks systems include Fibre Channel bus. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 324
functions and protocols. NL_Ports and FL_Ports are loop-capable ports. link A connection between two Fibre Channel ports consisting of a transmit fibre and a receive fibre. 324 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 325
paths, enter configuration information, and check the controller's status. The maintenance terminal is not required for normal operations. See also local terminal; local connection. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 325 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 326
to support storageset configuration and partitioning. Non transportable disks also contain metadata to indicate they are uniquely configured for HP StorageWorks environments use in all three topologies. 326 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 327
control and indicator panel associated with a controller. The OCP is mounted on the controller and is accessible to the operator operator control panel See OCP HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 327 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 328
physical memory, that can provide the system with input or accept any output from it. Terminals, printers, tape drives, and disks are peripheral devices. 328 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 329
with the fabric and can observe the rules of either public or private loop behavior. A public NL_Port can communicate with both private and public NL_Ports. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 329 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 330
, unlike RAID level 3, stores the parity information across all of the disk drives within the storageset. See also RAID level 3. RAIDset See RAID level 3/5 330 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 331
on the local controller is designated as the "initiator" and a corresponding unit on the remote controller is designated as the "target." See also association set. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 331 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 332
NOAUTOSPARE. request rate The rate at which requests are arriving at a servicing entity. RFI Radio Frequency Interference. The disturbance of a signal by an SCSI device is connected. 332 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 333
as in parallel transmission. service rate The rate at which an entity is able to service requests. For example, which an Arbitrated Loop is able to service arbitrated requests. signal converter See SCSI bus storage subsystem HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 334
-redundant configuration pair that serves its companion's devices the companion controller fails. switch A method that controls the flow of functions and operations in software. 334 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 335
relation to a timing signal. See also asynchronous. tape A storage device supporting sequential access to variable sized data records. target (1) A SCSI device that bus. See also Wide Ultra SCSI. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 335 Command Line - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 336
abruptly interrupted. A battery backed-up cache design eliminates the write hole because data is preserved in cache and unsuccessful write operations can be retried. 336 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 337
the subsystem's response time to a read. This method allows the controller to satisfy the request from the cache memory rather than from the disk drives. HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 337 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 338
Glossary 338 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 339
65 syntax 63 ADD MIRRORSETS command parameters 67 description 67 parameters disk-name 67 mirrorset-name 67 related commands ADD DISKS 69 ADD UNITS 69 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 339 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 340
commands DELETE container-name 83 SET UNITS 83 restrictions mirrored cache 81 software version 81 syntax 81 ADD SPARESETS command parameters 84 description 84 340 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 341
-set-name 175 audience 30 authorized reseller, HP 38 AUTOSPARE, switch for SET FAILEDSET 212 B BATTERY_OFF, switch for POWEROFF 155 BATTERY_ON, switch for POWEROFF 155 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 341 Command Line Interface Reference Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 342
103 parameters, device-name 103 related commands, CLEAR_ERRORS CLI 104 INVALID_CACHE 104 UNWRITEABLE_DATA 104 syntax 103 CLEAR_ERRORS unit-number LOST_DATA command parameters 105 342 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 343
container-name 124 FAILEDSETS 126 remote-copy-set-name 127 SPARESETS 129 unit-number 130 DESTROY_PARTITION 132 DIRECTORY 134 EXIT 136 HELP 137 INITIALIZE 139 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 343 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 344
CONFIG, running 170 configuration modifying controller configurations resetting 109 restoring 112, 144 CONFIGURATION RESET description 109 related commands CONFIGURATION RESTORE 111 344 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 345
-number 119 DESTROY PARTITION 119 SET unit-number 119 SHOW 119 switches SIZE 118 syntax 117 creating disk drives 63 mirrorsets 67 passthrough devices 70 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 345 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 346
129 syntax 129 DELETE unit-number command parameters 130 description 130 parameters unit-number 130 related commands ADD UNITS 130 CLEAR_ERRORS 130 LOST_DATA 130 346 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 347
document conventions 34 prerequisites 30 related documentation 31 DRM, CLI commands ADD ASSOCIATIONS 52 ADD REMOTE_COPY_SETS 78 SET remote-copy-set-name 231 SITE_FAILOVER 306 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 347 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 348
137 help, obtaining 38 HOST_ID=, parameter for ADD CONNECTIONS 57 HOST_REDUNDANT, switch for SET unit-number 238 HP authorized reseller 38 storage website 38 technical support 38 HP StorageWorks array controller HSUTIL, running 171 I IDENTIFIER=, switch for SET controller 188 SET unit-number 239 - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 349
MEMBERSHIP=, switch for SET mirrorset-name 217 MIRROR command parameters 151 description 151 parameters disk-name 151 mirrorset-name 152 related commands ADD MIRRORSETS 154 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 349 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 350
to a single device 308 creating from a single disk 151 deleting 124 manually removing a member 218 removing a member 158 renaming 165 showing 297 unmirroring switch for ADD UNITS 95 350 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 351
ALL 149 association-set-name 52, 120, 175 CANCEL 149 CLEAR_ERRORS controller INVALID_CACHE controller 100 data-retention-policy 101 device-name UNKNOWN, device-name 103 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 351 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 352
remote-copy-set-name, remote-copy-set-name 231 unit-number, unit-number 235 SHUTDOWN controller, controller 304 SITE_FAILOVER remote-copy-set-name 306 352 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 353
policy 74 showing 297 specifying chunksize 142 specifying replacement policy 227 read requests See also write requests. setting for improved host application performance 95, 241 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 353 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 354
167 description 167 parameter, controller 167 related commands SELFTEST controller 168 SHUTDOWN controller 168 switches IGNORE_ERRORS 167 IMMEDIATE_SHUTDOWN 168 NOIGNORE_ERRORS 167 354 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 355
178 switches ADD= 176 FAIL_ALL 176 LOG_UNIT 176 NOFAIL_ALL 176 NOLOG_UNIT 176 NOORDER_ALL 177 ORDER_ALL 177 REMOVE 178 syntax 175 SET concatsets command parameters 180 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 355 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 356
208 related command, SHOW 206 switches ALARM= 208 FANSPEED= 209 SENSOR_n_SETPOINT= 209 syntax 208 SET ENABLE_MANAGERS description 211 SET FAILEDSET command parameters 212 356 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 357
231 related commands ADD REMOTE_COPY_SETS 234 SET controller REMOTE_COPY 234 switches ADD= 232 ERROR_MODE= 232 INITIATOR= 232 OPERATION_MODE= 233 OUTSTANDING_IOS= 233 REMOVE= 233 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 357 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 358
for units 95, 243 SHOW ASSOCIATIONS description 245 switch, FULL 245 syntax 245 SHOW association-set-name command parameters 246 description 246 syntax 246 358 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 359
289 syntax 289 SHOW REMOTE_COPY_SETS description 292 switch, FULL 292 syntax 292 SHOW remote-copy-set-name command parameters 294 REMOTE_COPY_SETS description 294 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 359 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 360
142 SUSPEND=, switch for SET remote-copy-set-name 234 switches 242 ADD CONNECTIONS OPERATING_SYSTEM= 59 RESERVATION_STYLE= 60 UNIT_OFFSET 60 ADD DISKS NOTRANSPORTABLE 65 360 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 361
= 142 CYLINDERS= 141 DESTROY 143 DESTROY_MBR 143 HEADS= 141 NODESTROY 143 NOSAVE_CONFIGURATION 144 SAVE_CONFIGURATION 144 SECTORS_PER_TRACK= 141 INITIATOR= 232 LOG_UNIT= 176 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 361 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 362
167 NOIMMEDIATE_SHUTDOWN 168 RESUME= 234 RUN 91, 242 SAVE_CONFIGURATION 144 SCSI_FAIRNESS= 195 SCSI_VERSION= 196 SECONDS= 156 SECTORS_PER_TRACK= 141 SELFTEST controller 362 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 363
NOPOLICY 227 POLICY= 227 RECONSTRUCT= 228 REMOVE= 228 REPLACE= 229 SET remote-copy-set-name ADD= 232 ERROR_MODE= 232 INITIATOR= 232 OPERATION_MODE= 233 OUTSTANDING_IOS=S 233 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 363 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 364
equipment 35 syntax ADD ASSOCIATIONS 52 CONCATSETS 54 CONNECTIONS 56 DISKS 63 MIRRORSETS 67 PASSTHROUGH 70 RAIDSETS 73 REMOTE_COPY_SETS 78 SNAPSHOT_UNITS 81 SPARESETS 84 364 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 365
SHOW STORAGESETS 297 SHOW stripeset-name 299 SHOW STRIPESETS 301 SHOW unit-number 302 SHUTDOWN controller 304 SITE_FAILOVER 306 UNMIRROR 308 WWID_ASSIGN storageset LUN_WWID= 310 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software 365 Command Line Interface Reference - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 366
Switches for Existing Containers 235 technical support, HP 38 terminal setting parity 197 setting switch for ADD DISKS 65 SET device-name 204 troubleshooting guide 31 U UNIT_OFFSET, switch for ADD CONNECTIONS 60 366 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 367
definition of 34 rack stability 37 symbols on equipment 35 Index websites HP storage 38 write requests improving the subsystem response time with write-back caching description 310 WWID_ASSIGN storageset LUN_WWID= syntax 310 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller - HP StorageWorks EMA12000 | HP StorageWorks HSG60 and HSG80 Array Controller and - Page 368
Index 368 HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide
Reference
Guide
HP StorageWorks
HSG60 and HSG80 Array
Controller and Array Controller
Software Command Line
Interface
Product Version:
8.8-1
Third Edition (March 2005)
Part Number:
EK-G80CL-RA. C01
This guide provides detailed descriptions of all HP StorageWorks Array Controller Software
(ACS) Command Line Interface (CLI) commands and instructions on how to use each
command.