HP StorageWorks EMA12000 HP StorageWorks HSG80 ACS Solution Software V8.8 for
HP StorageWorks EMA12000 Manual
View all HP StorageWorks EMA12000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks EMA12000 manual content summary:
- HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 1
HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Product Version: 8.8-1 First Edition (March 2005) Part Number: AA-RV1RA-TE This guide provides installation and configuration instructions and reference material for operation of the HSG80 ACS Solution Software V8.8-1 for Sun Solaris. - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 2
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting V8.8 for Sun Solaris Installation and Configuration Guide First Edition (March 2005) Part Number: AA-RV1RA-TE - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 3
contents About this Guide 13 Overview 14 Intended Audience 14 Related Documentation 14 Chapter Content Summary 16 Conventions 18 Document conventions 18 Symbols in Text 18 Symbols on Equipment 19 Rack Stability 20 Getting Help 21 Technical Support 21 Storage web site 21 HP Authorized - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 4
80 Keep these points in mind when planning mirrorsets 81 RAIDset Planning Considerations 81 4 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 5
111 Example 111 Creating and Tuning File Systems 113 Solution Software Upgrade Procedures 113 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 5 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 6
FC Cable and Verify Connections 145 Repeating Procedure for Each Host Adapter Connection 145 6 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 7
Channel Access/Transport Paths 161 Implementation of Loop and Fabric Bindings 162 Bindings 162 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 7 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 8
4310R Disk Enclosure 209 Storage Map Template 7 for the Model 4350R Disk Enclosure 211 8 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 9
CIM 220 Finding the Controller's Storage Window 221 Troubleshooting Client Installation 221 Invalid Network Port Assignments During Installation Console Client 225 Where to Find Additional Information 226 About the User Guide 226 About the Online Help 226 Glossary 227 Index 249 Figures 1 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 10
window showing expanded "Atlanta" host icon 224 Tables 1 Summary of Chapter Contents 16 10 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 11
(Describes the controller pair 160 17 Example of Active-Passive with a Single Controller 160 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 11 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 12
Contents 12 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 13
help you: ■ Plan the storage array subsystem ■ Install and configure the storage array subsystem on individual operating system platforms "About this Guide" topics include: ■ Overview, page 14 ■ Chapter Content Summary, page 16 ■ Conventions, page 18 ■ Rack Stability, page 20 ■ Getting Help, page 21 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 14
HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller Software Troubleshooting Guide, EK-G80TS-SA. C01 ■ StorageWorks Command Console (SWCC) v2.5 documentation (client software - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 15
this Guide ■ HP StorageWorks HSG80 ACS Solution Software Release Notes (platform-specific) ■ HP StorageWorks Enterprise/Modular Storage RAID Array Fibre Channel Arbitrated Loop Configurations for Windows, Tru64, and Sun Solaris Application Note (AA-RS1ZB-TE) - Solution software host support includes - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 16
About this Guide Chapter Content Summary Table 1 below summarizes the content of the chapters. Table the differences and configuration processes for Sun servers and adapters for loop and switch support. How-to example of configuring a storage subsystem using the Command Line Interpreter (CLI - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 17
common procedures that are not mentioned elsewhere in this guide. Backing Up Subsystem Configuration Cloning Data for Backup You Install the Client ■ Installing the Client ■ Installing Integration Patch ■ Troubleshooting the Client Installation ■ Adding Storage Subsystem and its Host to the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 18
case sensitive Monospace, italic font Sans serif font (http://www.hp.com) Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in bodily - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 19
About this Guide Note: Text set off in this manner presents commentary, sidelights, or marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of injury from electrical shock hazards, do not open - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 20
About this Guide Any product or assembly marked with these symbols indicates that injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. Rack Stability WARNING: To reduce the risk of personal injury or damage to the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 21
If you still have a question after reading this guide, contact an HP authorized service provider or access our web site. Technical Support Telephone numbers for worldwide technical support are listed on the following HP web site: http://www.hp.com/support/. From this web site, select the country of - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 22
About this Guide HP Authorized Reseller For the name of your nearest authorized reseller: ■ In the United storage subsystem. All references in the flowcharts pertain to pages in this guide, unless otherwise indicated. 22 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 23
About this Guide Unpack subsystem See the unpacking instructions on shipping box Plan a Subsystem Chapter 1 Plan Storage Configurations Chapter 2 Prepare Host General configuration flowchart (panel 1) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 23 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 24
About this Guide A Configure devices page 146 Continue creating units until you have completed your planned configuration. Create Storagesets and Partitions: 2: General configuration flowchart (panel 2) 24 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 25
About this Guide B Install Agent Chapter 4 Install Client Appendix B Create Storage See SWCC online help Verify Storage Set Up Figure 3: SWCC storage configuration flowchart (panel 3) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 25 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 26
About this Guide 26 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 27
of the CLI commands, see the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. The following information is included in this chapter: ■ Defining Subsystems, page 28 ■ What is Failover Mode?, page 31 ■ Selecting a Cache Mode - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 28
module CXO7365A B Figure 4: Location of controllers and cache modules in a Model 2200 enclosure 28 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 29
"other controller" in a Model 2200 enclosure. Figure 7 shows the same relationship in a BA370 enclosure. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 29 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 30
2 This controller CXO6468D Figure 7: "This controller" and "other controller" for the BA370 enclosure 30 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 31
of failover can work with loop or fabric topology. Note: Multiple-bus failover mode is only supported on Sun platforms when Secure Path is used. Refer to the Secure Path documentation for more information . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 31 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 32
for failures of either the Fibre Channel link or host Fibre Channel adapters. 32 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 33
D120 Host port 1 standby Controller B Host port 2 active Figure 8: Transparent failover-normal operation CXO7036A HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 33 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 34
Each host has two or more paths to the units All hosts must have operating system support or additional software that supports multiple-bus failover mode. With this software, the host sees the same units visible through ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 35
-bus failover mode, you can specify which units are normally serviced by a specific controller of a controller pair. Units can between the controllers. ■ All hosts must have operating system software that supports multiple-bus failover mode. HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 36
2 active NOTE: FCA = Fibre Channel Adapter Figure 10: Typical multiple-bus configuration CXO7094B 36 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 37
Planning a Subsystem Selecting a Cache Mode The cache module supports read, read-ahead, write-through, and write-back caching techniques. The cache technique is selected separately for the host when the write HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 37 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 38
: Mirrored caching Before enabling mirrored caching, make sure the following conditions are met: ■ Both controllers support the same size cache. ■ Diagnostics indicate that both caches are good. ■ No unit errors are HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 39
the CCL in SCSI-2 mode, use the following CLI command: HSG80 > SET THIS_CONTROLLER COMMAND_CONSOLE_LUN HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 39 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 40
and an active host port on a controller. Note: In ACS Version 8.8-1, the maximum number of supported connections is 96. Naming Connections It is highly recommended that you assign names to connections that have HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 41
loop or fabric), each adapter will have two connections, as shown in Figure 13. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 41 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 42
Channel Adapter CXO7081B Figure 12: Connections in separate-link, transparent failover mode configurations 42 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 43
= Fibre Channel Adapter CXO7079B Figure 13: Connections in single-link, transparent failover mode configurations HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 43 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 44
: FCA = Fibre Channel Adapter Figure 14: Connections in multiple-bus failover mode CXO7080B 44 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 45
) - Unit number is relative to the controller (what the controller sees the unit as) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 45 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 46
unit's range (unit number of 127 minus offset of 128 is a negative number). 46 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 47
is done through the ENABLE_ACCESS_PATH switch of the ADD UNIT (or SET unit) command. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 47 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 48
be at LUN 0. In this case, it is necessary to specify SCSI-2 mode. 48 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 49
without enabling connections. This provides more control in granting appropriate access to specific connections. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 49 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 50
all units. See "Restricting Host Access by Disabling Access Paths" on page 51. 50 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 51
for each unit. Default access enables the unit to be accessible to all hosts. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 51 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 52
host BROWN's access, as follows: SET D120 DISABLE_ACCESS_PATH=ALL SET D120 ENABLE_ACCESS_PATH=BROWN1B2 52 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 53
and the host must be enabled in order for multiple-bus failover to work. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 53 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 54
the connections to host BLUE. At least two connections must be enabled for 54 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 55
host connections to the same host computer must be set to the same offset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 55 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 56
-EE01 ■ Controller A and controller B, port 2-worldwide name + 2, for example 5000-1FE1-FF0C-EE02 56 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 57
CXO7228A Figure 18: Placement of the worldwide name label on the Model 2200 enclosure HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 57 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 58
the unit is reinitialized. Use the SHOW command to list the LUN ID. 58 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 59
page 88 ■ Specifying Initialization Switches, page 89 ■ Specifying Unit Switches, page 93 ■ Creating Storage Maps, page 93 Refer to Chapter 3 for instructions on how to prepare your host computer to accommodate the HSG80 controller storage subsystem. HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 60
). 8. Configure the storage you have now planned using one of the following methods: 60 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 61
naming your storage containers. See the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Determining Storage Requirements It is important to determine your storage requirements. Here are a few of the questions you should ask - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 62
activities to avoid operational and performance issues. Note: HSG60 and HSG80 array controllers do not support greater than 146 GB. This restriction is enforced by the firmware. Addressing Conventions for Device 62 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 63
is always 0. 1 02 00 LUN 00 Target 02 Port 1 Figure 21: PTL naming convention HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 63 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 64
set through the PVA module. Enclosure ID number 1, which assigns devices to targets 4 through 7, is not supported. Figure 22 shows how data is laid out on disks in an extended configuration. Operating system view Virtual Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 65
above the controller enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 65 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 66
you keep track of the location of devices and storagesets in your shelves. 66 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 67
Disk50800 Disk51000 Disk51100 Disk51200 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 67 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 68
Disk21000 Disk21100 Disk21200 Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 68 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 69
04 ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 69 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 70
Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk10900 Disk11000 Disk11100 Disk11200 Disk11300 Disk11400 Disk11500 70 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 71
01 02 03 04 05 08 00 01 02 03 04 05 08 ID HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 71 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 72
drives or ten, looks like one large, virtual disk drive to the host. 72 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 73
Containers Planning Storage Configurations Partition Single devices (JBOD) Stripeset (R0) Storagesets Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 23: Storage container types CXO6677A HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 73 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 74
discussion of RAID, refer to The RAIDBOOK-A Source Book for Disk Array Technology. 74 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 75
(default) ___Best fit ___Fast ___None Read Source ___Least busy (default) ___Round robin ___Disk drive: HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 75 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 76
in the storageset, thereby enabling several disk drives to participate in one I/O request. 76 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 77
of reference) that occur when frequently accessed data becomes concentrated on a single disk drive. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 77 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 78
of these disks would only have an MTBF of slightly more than 4 years. 78 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 79
for storing data that can be reproduced easily or whose loss does not prevent the system from supporting its critical mission. ■ Evenly distribute the members across the device ports to balance the load ports. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 79 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 80
1 Block 2 etc. Mirrorset Figure 27: Mirrorset (example 2) Disk 2 Block 0 Block 1 Block 2 etc. CXO4594B 80 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 81
ensure data availability. Figure 28 shows an example of a RAIDset that uses five members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 81 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 82
from working with large RAIDsets. ■ Both cache modules must be the same size. 82 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 83
high data availability. Figure 30 shows a second example of a striped mirrorset using six members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 83 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 84
(example 2) Disk 5 Block 2 Block 5 Block 8 Disk 6 Block 2 Block 5 Block 8 Virtual disk #3 Mirrorset CXO6462A 84 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 85
Controller and Array Controller Software Command Line Interface (CLI) Reference Guide describes the CLI command, ADD CONCATSETS, which is used to Use the ADD CONCATSETS command only with host operating systems that support dynamic volume expansion. Use of this command could result in inacessible - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 86
are separately addressable storage units; therefore, you can partition a single storageset to service more than one user group or application. Defining a Partition Partitions are expressed as about cloning.) 86 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 87
the SWCC online help for information about using SWCC. If you use CLI commands to configure the storageset or device manually, the configuration procedure found in Chapter 5 of this guide will show you when and how to enable each switch. The HP StorageWorks HSG60 and HSG80 Array Controller and Array - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 88
-name commands in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Mirrorset Switches Use the following switches to control how a mirrorset behaves to ensure data availability: ■ Replacement policy ■ Copy speed ■ Read - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 89
command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Specifying Initialization Switches Initialization switches set characteristics for established storagesets before they are made into units. The following kinds - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 90
first analyze the types of requests that are being made to the subsystem: 90 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 91
. The SHOW DEVICES FULL command shows which disks are used to backup configuration information. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 91 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 92
SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. Note: HP Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for information on removing disk drives from a mirrorset. NODESTROY is - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 93
SET unit-number command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. One unit switch, ENABLE/DISABLE_ACCESS_PATH, determines which host connections can access the unit, and it is described in the larger topic of - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 94
R1. 3. Enter the following command to turn off the flashing LEDs: LOCATE CANCEL 94 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 95
M1 M5 DISK ID Disk10000 Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk11000 Disk11100 Disk11200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 95 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 96
. ■ Unit D102 is a 2-member mirrorset named M3. M3 consists of Disk10200 and Disk20200. 96 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 97
named M7. M7 consists of Disk11200 and Disk21200. ■ Disk31200 and Disk41200 are spareset members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 97 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 98
Planning Storage Configurations 98 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 99
■ Making a Physical Connection, page 104 ■ Installing Solution Software Packages, page 108 ■ Creating and Tuning File Systems, page 113 Refer to Chapter 4 for instructions on how to install and configure the HSG Agent. The Agent for HSG is operating system-specific and polls the storage. HSG80 ACS - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 100
use the disk enclosure handles to lift the enclosure. The handles cannot support the weight of the enclosure. Only use these handles to position the enclosure SCSI Controller Enclosures User Guide and the StorageWorks Model 4300 Family Ultra3 LVD Disk Enclosures User Guide for further information. 2. - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 101
unused bays. Fibre Channel cabling information is shown to illustrate supported configurations. In a dual-bus disk enclosure configuration, disk enclosures dual-bus system and Figure 34 for a single-bus system. Note that the supported cable lengths are 1, 2, 3, 5, and 10 meters. 5. Connect the AC - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 102
Channel Ports Figure 33: Dual-Bus Enterprise Storage RAID Array Storage System CXO7383A 102 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 103
6 Cable 8 Fibre Channel Ports Figure 34: Single-Bus Enterprise Storage RAID Array Storage System HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 103 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 104
computer hardware manual ■ Appropriate tools to service your computer The host bus adapter board plugs into a standard PCI or Sbus slot in the host computer. Refer to the system manual for instructions on installing Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 105
Solaris 2.6, 7, 8, and 9. HPfcraid SWCC StorageWorks RAID Manager version 3.0D. SWCC for Windows NT 4.0 workstation. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 105 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 106
adapter driver packages. 4. Load the CPQptisp package (optional, only required to support legacy RAID systems attached to an SBS-450 SCSI adapter). 5. Load the monitored. See Chapter 4 for configuration instructions. 106 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 107
disk space will be used by the logfiles in the /var/adm/steam directory. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 107 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 108
to remove and replace all currently installed drivers. ■ The install option "Select mode automatic or manual [A,m] :" has been removed. The option has been replaced with appropriate queries to install available drivers ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 109
by the Solution Software installation. The following files are already installed on the system and are being used by another package: /etc/inet/services /etc/nsswitch.conf /etc/syslog.conf /etc/system Do you want to install these conflicting files [y,n,?] Installation Manager prompts you to rescan - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 110
files for adapters can be selected automatically or manually. - Choose "M" to manually edit your file. You can choose what FC adapters and what targets will be supported. By default, LUNs 0 through 15 are 110 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 111
use of the fdisk utility may be found in the Sun 2.x Adding and Maintaining Peripherals Manual. Labeling a LUN Automatically Using the Format Utility Sun Solaris releases 2.6 and later can automatically HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 111 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 112
about the creation of format.dat entries may be found in the Sun Solaris 2.x Adding and Maintaining Peripherals Manual. Note: Although the format command will create an HSG80 disk entry in the format.dat file, do HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 113
to upgrade. 2. Verify operating system versions, upgrade operating systems to supported versions and patch levels. 3. Quiesce all I/O and unmount all the purpose of performing upgrades to the ACS firmware, this Solution Software Kit supports previous ACS V8.6 and V8.7. Do not mix ACS versions in the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 114
and Array Controller Software Maintenance and Service Guide and the Solution Software Release Notes the upgrade). Note: Rolling upgrades are not supported on Sun Solaris when using Qlogic HBAs. Use following web site and follow the upgrade instructions in the enclosed documentation. Secure Path 3. - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 115
Preparing the Host System HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 115 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 116
Preparing the Host System 116 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 117
Chapter 5 for a description of how to configure a subsystem that uses Fibre Channel fabric topology. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 117 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 118
virtual disks. The Client runs on Windows Server 2003 (32-bit), Windows 2000 with Service Pack 3 and 4, and Windows NT 4.0 with Service Pack 6A or above. ■ The Agent obtains the status of the storage connected to HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 119
and Configuration Overview Step 1. 2. 2 3. 3 4. 4 5. 5 6. 7. Procedure Verify that your hardware has been set up correctly. See the previous chapters in this guide. Verify that RAID Solution Software has been loaded properly. Refer to Chapter 3. Verify that you have a network connection for the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 120
the LAN. If you have a WAN or a connection to the Internet, monitor the subsystem with TCP/IP. Note: SWCC does not support the dynamic host configuration protocol (DHCP) or the Windows Internet Name Service (WINS). 120 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 121
6 HSG80 controller and its device subsystem 7 Servers Figure 35: An example of a network connection HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 121 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 122
). Verify that your system meets the minimum requirements by completing the following steps. 122 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 123
sh-This utility is usually used for first-time configuration or upgrades. It guides you through the configuration of your Agent. It also identifies and upgrades any .8 Configuration Menu" on page 124 for instructions on running Config.sh. HSG80 ACS Solution Software V8.8 for Sun - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 124
first-time configurations, run the install.sh script from the $basedir/steam/bin directory (usually /opt/steam/bin). This script will guide you through the following actions: ■ Adding a subsystem entry ■ Adding a Client entry ■ Creating a password ■ Setting up email notification ■ Starting the Agent - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 125
configuration privileges will be asked for this password when attempting to configure the subsystem. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 125 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 126
. 5. Add an Error Notification Level (1 for TCP sockets, 2 for SNMP, or 3 for both). 126 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 127
Mail Messages Mail messages sent by the RAID Manager are useful in troubleshooting subsystem problems. To receive RAID Manager messages, you must enable "email notification Console Version 2.5, User Guide. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 127 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 128
Installing and Configuring the HSG Agent 128 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 129
. To install a controller or cache module and the PCMCIA card, see the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 130
maintenance port cables when not communicating with the controller through the local connection. 130 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 131
Enter. 5. Press Enter again, and the CLI prompt appears, similar to the following: HSG80> HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 131 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 132
part of the configuration procedure ("Configuring a Single Controller Using CLI" on page 133). 132 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 133
(Node IDs and Port IDs)" on page 56 for the location of the sticker. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 133 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 134
the following command syntax: SET THIS SCSI_VERSION=SCSI-2, or SET THIS SCSI_VERSION=SCSI-3 134 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 135
to replace the battery, answer "Y": Do you intend to replace this controller's cache battery? Y/N [N] Y HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 135 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 136
CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for the format of optional settings. 4. Verify that all commands have taken effect. Use the following command: SHOW THIS Verify node - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 137
(10 seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 ....... HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 137 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 138
to communicate with the Fibre Channel switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable and Verify Connections 6. Plug the Fibre ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 139
as part of the configuration procedure ("Configuring a Controller Pair Using CLI" on page 140). HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 139 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 140
IDs and Port IDs)" on page 56, for the location of the sticker. 140 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 141
the SCSI version to SCSI-32 using the following command: SET THIS SCSI_VERSION=SCSI-2 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 141 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 142
CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for the format of optional settings. Perform this step on both controllers. 142 HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 143
FC Configuration Procedures 15. Verify that all commands have taken effect by entering the following command: SHOW THIS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 143 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 144
seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 144 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 145
to communicate with the FC switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable and Verify Connections 18. Plug the . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 145 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 146
are accessible. Configuring Devices The disks on the device bus of the HSG80 can be configured manually or with the CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following command 150 146 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 147
of 128: ADD STRIPESET STRIPE1 DISK10000 DISK20000 DISK30000 INITIALIZE STRIPE1 CHUNKSIZE=128 SHOW STRIPE1 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 147 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 148
command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the mirrorset switches. 2. Initialize the mirrorset, specifying any desired switches: INITIALIZE MIRRORSET-NAME SWITCHES See "Specifying - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 149
RAIDSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the RAIDset switches. 2. Initialize the RAIDset, specifying any desired switches: INITIALIZE RAIDSET-NAME SWITCH Note: HP recommends - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 150
See "Specifying Initialization Switches" on page 89 for a description of the initialization switches. 150 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 151
the CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the partition switches. 3. Verify the partitions: SHOW STORAGESET-NAME or SHOW DISK-NAME The partition number appears - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 152
the ADD UNIT command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Because of different SCSI versions, refer to the section "Assigning Unit Numbers Depending on SCSI_VERSION" on page 48. The choice for SCSI_VERSION - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 153
to the controller should it need to replace a failed member of a RAIDset or mirrorset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 153 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 154
disk drive is automatically initialized and placed into the spareset. If initialization fails, the disk drive remains in the failedset until you manually delete it from the failedset. To enable autospare, use the following command: SET FAILEDSET AUTOSPARE 154 HSG80 ACS Solution Software V8.8 for - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 155
are associated with it. Remember to update the storageset profile when changing its switches. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 155 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 156
example, the following command enables write protection for unit D100: SET D100 WRITE_PROTECT 156 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 157
complex configurations, with Fibre Channel's ability to support transmission lengths in terms of miles/kilometers, the problems of design, installation, testing and documentation require ■ Hubs ■ Switches HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 157 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 158
the desired I/O quantity, it may not support a desired performance characteristic of the I/O. Thus, both configuration and performance can be best described with some test trials of a specific configuration. 158 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 159
is a RAID Array that is supported by the HSG80 controller. This controller supports all of the standard RAID set one controller fails, the second controller will automatically service the I/O stream, protecting data integrity. Typically, Solaris Installation and Configuration Guide 159 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 160
enabling the loop to continue to function. Note: Because cascading hubs are not supported, the largest supported loop configuration using hubs consists of 12 ports maximum. Switches Switches enable multiple 160 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 161
switches and care must be taken when integrating the two switch configurations. The most common problem encountered when adding a switch to the fabric is domain overlap, especially when interconnecting ALPA. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 161 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 162
follows: If a WWNN is FFFF-SSSS-TTTT-LLL0 the corresponding Port Names are: 162 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 163
it and record the various connections and paths. This activity will provide a valuable tool for support of Fibre Channel fabric installations. Loop Connections at the Solaris Level SCSI Target bindings are defined in Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 163 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 164
/sbus@f,e0001000/fcaw@1,0" Target=64 lun=15 ww pn="5000-1fe1-0000-13f1"; 164 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 165
/config.sh file. All other options can still be found in /opt/steam/bin. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 165 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 166
installed, the user has the opportunity to define the specific type of Fibre Channel configuration for each adapter, either loop or fabric (QLogic HBAs are supported in fabric-mode only). 166 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 167
configuration file, fca.conf, fcaw.conf, fca-pci.conf, qla2200.conf, or qla2300.conf. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 167 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 168
modify by entering the NN (numeric identification at the left in the list). 168 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 169
FC Configuration Procedures Option 5 - View Available WWPNs Select this option to run the Scan Adapters Utility. This utility detects available adapters and WWPNs for this host. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 169 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 170
loop mode. When you implement loop mode, the ALPAs are used for access. 170 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 171
, otherwise the Target will be suppressed. ■ Driver fcaw for adapter fcaw. - Target: 64, WWPN HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 171 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 172
server must be rebooted with the ( -r) reconfigure switch. Enter the following command: # reboot -- -r 172 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 173
■ The server in question has an adapter to support the Fibre Channel loop or fabric. ■ A storage system is available that will support a fibre connection. ■ Hubs and switches are available boot. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 173 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 174
change was made to the server or controller.) Reconfiguring from Loop to Fabric Note: QLogic HBAs are supported in fabric-mode only. Note: This procedure assumes that the Solaris platform kit is loaded and everything ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 175
the units of the subsystems are now available. Reconfiguring from Fabric to Loop Note: QLogic HBAs are supported in fabric-mode only. Note: This procedure assumes that the Solaris platform kit is loaded and everything Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 175 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 176
FC Configuration Procedures 5. At the servers, reconfigure the adapters to support loop. This is accomplished with /opt/HPfcraid/bin/config.sh, Option 4, Modify Adapters. This option are now available. 176 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 177
resulting virtual system, from the host's point of view, is shown in Figure 43. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 177 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 178
port 2 of both controllers are on another). Therefore, each adapter has two connections. 178 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 179
44 represents an example of virtual system layout from the hosts' point of view. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 179 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 180
cable from maintenance terminal into top controller. CLEAR CLI SET FAILOVER COPY=THIS 180 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 181
Plug in the Fibre Channel cable from the adapter in host "PURPLE." SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 181 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 182
ADAPTER_ID=XXXX-XXXX-XXXX-XXXX 1 XXXXXX OL 0 other ADAPTER_ID=XXXX-XXXX-XXXX-XXXX 182 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 183
XXXX RENAME !NEWCON02 TAN1B2 SET TAN1B2 OPERATING_SYSTEM=SUN SET TAN1B2 UNIT_OFFSET=120 SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 183 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 184
=XXXX-XXXX-XXXX-XXXX Mark or tag both end of Fibre Channel cables. 184 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 185
D101 DISK50300 DISABLE_ACCESS_PATH=ALL SET D101 ENABLE_ACCESS_PATH=(WHITE1B2) ADD SPARESET DISK60300 SHOW UNITS FULL HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 185 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 186
Using CLI for Configuration 186 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 187
Backing Up, Cloning, and Moving Data This chapter includes the following topics: ■ Backing Up Subsystem Configurations, page 188 ■ Creating Clones for Backup, page 189 ■ Moving Storagesets, page 195 7 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 187 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 188
is backed up. Note: Do not use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. The SHOW DEVICES FULL command shows which disk drives ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 189
, you can back up the clones rather than the storageset or single-disk unit, which can continue to service its I/O load. When you are cloning a mirrorset, CLONE does not need to create a temporary mirrorset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 189 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 190
you want to use for the clone units. 7. Back up the clone unit. 190 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 191
C_MA MEMBERS=2 SET C_MA REPLACE=DISK20200 DEVICES AVAILABLE FOR CLONE TARGETS: DISK20300 (SIZE=832317) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 191 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 192
ID is the 64-bit Fibre Channel node id of the controller pair. 192 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 193
WWID associated with the source unit instead of allocating a new one. CLI> run clonew HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 193 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 194
one linked WWID variation. If the linked WWID is already in use, then a new unique WWID is allocated. Manual Clone Creation - The user has his own set of scripts that create clones, and wants to update them to 194 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 195
the release notes for the version of your controller software for information on which drives can be supported. Caution: Never initialize any container or this procedure will not protect data in the storageset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 195 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 196
cabinet DELETE D100 DELETE RAID99 DELETE DISK10000 DELETE DISK10100 DELETE DISK20000 DELETE DISK20100 196 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 197
Backing Up, Cloning, and Moving Data New cabinet ADD DISK DISK10000 ADD DISK DISK10100 ADD DISK DISK20000 ADD DISK DISK20100 ADD RAIDSET RAID99 DISK10000 DISK10100 DISK20000 DISK20100 ADD UNIT D100 RAID99 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 197 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 198
Backing Up, Cloning, and Moving Data 198 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 199
Enclosure, page 212 ■ Storage Map Template 9 for the Model 4354R Disk Enclosure, page 214 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 199 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 200
Read Source ___Least busy (default) ___Round robin ___Disk drive: Metadata ___Destroy (default) ___Retain 200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 201
Subsystem Profile Templates Unit Switches: Caching Access by following hosts enabled Read caching__________ Read-ahead caching_____ Write-back caching______ Write-through caching____ HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 201 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 202
D30100 D40100 D50100 D60100 Power Supply D10000 D20000 D30000 D40000 D50000 D60000 2 Targets 1 0 202 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 203
D10900 D20900 D30900 D40900 D50900 D60900 Power Supply 8 D10800 D20800 D30800 D40800 D50800 D60800 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 203 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 204
D31300 D41300 D51300 D61300 Power Supply 12 D11200 D21200 D31200 D41200 D51200 D61200 204 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 205
Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 205 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 206
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 206 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 207
Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 DISK ID HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 207 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 208
Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 DISK ID 208 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 209
11 12 DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 209 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 210
12 DISK ID Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 210 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 211
11 12 DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 211 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 212
Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk40900 Disk41000 Disk41100 Disk41200 Disk41300 Disk41400 Disk41500 212 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 213
Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 213 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 214
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 214 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 215
Client?, page 216 ■ Before You Install the Client, page 217 ■ Installing the Client, page 218 ■ Installing the Integration Patch, page 219 ■ Troubleshooting Client Installation, page 221 ■ Adding Storage Subsystem and its Host to Navigation Tree, page 223 ■ Removing Command Console Client, page 225 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 216
an individual device (JBOD) ■ Monitor many subsystems at once ■ Set up pager notification 216 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 217
the software product description that came with the software for a list of supported hardware. 3. Verify that you have the SNMP service installed on the computer. SNMP must be installed on the computer for 4. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 217 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 218
problem is not seen under Windows NT 4.0 Server. 2. Insert the CD-ROM into a computer running Windows 2000 with Service Pack 3 or 4, or Windows NT 4.0 (Intel) with Service instructions on the screen. After you install the software, the Asynchronous Event Service (AES) starts. AES is a service that - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 219
the HSG80 Client, you will no longer be able to access its Storage Window. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 219 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 220
the status of the system. 9. Click Launch. The controller's Storage Window is displayed. 220 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 221
Services tab. 2. Highlight the entry for Fibre Array Information and click Add. The Fibre Array Information entry is moved from Inactive Agents to Active Agents. Troubleshooting Client Installation This section provides information on how to resolve some of the problems manually to the services - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 222
to add the correct ports. The following shows how the network port assignments appear in the services file: spgui ccdevmgt kzpccconnectp ort kzpccdiscover yport ccfabric spagent spagent3 ccagent spagent2 4998/tc p 4993 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 223
. 4. Type the host name or its TCP/IP address and click Apply. 5. Click Close. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 223 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 224
the Storage Window icon. Figure 48: Navigation window showing expanded "Atlanta" host icon 224 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 225
HP StorageWorks Command Console Version 2.5, User Guide. Removing Command Console Client Before you This will prevent the system from reporting that a service failed to start every time the system is restarted. 6. Follow the instructions on the screen. HSG80 ACS Solution Software V8.8 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 226
on how to use SWCC. Some of the topics in the user guide are the following: ■ About AES ■ Adding Devices ■ Adding Virtual Disks ■ Setting Up Pager Notification ■ How to Integrate SWCC with Insight Manager ■ Troubleshooting Information About the Online Help Most of the information about the Client - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 227
on a removable ROM program card that provides the operating system for the array controller. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 227 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 228
header. A method used to bring a system or device into a defined state by means of its own action. For example, a machine routine whose first few instructions are enough to bring the rest of the routine into the computer from an input device. 228 HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 229
. Stripesets and mirrorsets are examples of storageset containers the controller uses to create units. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 229 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 230
, even though the host operation processing the data has completed. Direct Memory Access. 230 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 231
. The EMU also controls certain cabinet hardware including DOC chips, alarms, and fan speeds. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 231 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 232
Fibre Channel Fabric Generic Requirements Fibre Channel Framing Protocol (HIPPI on FC) Fibre Channel Generic Services-1 Fibre Channel Generic Services-2 Fibre Channel Implementation Guide Fibre Channel Link Encapsulation (ISO 8802.2) The Fibre Channel Physical and Signaling standard. Fibre Channel - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 233
block contains unrecoverable data. An invisible unit used to transfer information in Fibre Channel. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 233 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 234
heterogeneous host support HIPPI-FC host host adapter HBA Field replaceable unit. A hardware component that can be replaced at the customer location by service personnel or qualified customer service personnel. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 235
detected. A set of protocols used between components, such as cables, connectors, and signal levels. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 235 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 236
number. LUNs use their target bus connection to communicate on the SCSI bus. 236 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 237
and media defect management for the disk drive. It is also used to support storageset configuration and partitioning. Nontransportable disks also contain metadata to indicate they are or image of data. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 237 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 238
the mirrorset. Read requests from the host are always satisfied by normal members. 238 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 239
in participating mode. A logical division of a container, represented to the host as a logical unit. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 239 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 240
NL_Ports on the same loop. The PCMCIA card containing the controller operating software. 240 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 241
information across all of the disk drives within the storageset. See also RAID level 3. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 241 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 242
background. Data warehousing, continuous computing, and enterprise applications all require remote copy capabilities. 242 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 243
controller is designated as the "target". The rate at which requests are arriving at a servicing entity. Radio frequency interference. The disturbance of a signal by an unwanted radio signal or frequency . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 243 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 244
of storing data, whether it is a physical device or a group of physical devices. 244 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 245
each event to operate in relation to a timing signal. See also asynchronous. A storage device supporting sequential access to variable sized data records. (1) A SCSI device that performs an operation requested HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 245 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 246
drive. A unit may also be created from a more complex container such as a RAIDset. The controller supports a maximum of eight units on each target. See also target and target ID number. Sometimes called unflushed HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 247
the cache memory accordingly, to ensure that the cache contains the most current data. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 247 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 248
Glossary 248 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 249
152 assignment of unit numbers fabric topology Index partition 152 single disk 152 asynchronous event service 226 autospare enabling fabric topology 154 availability 81 B Back up, Clone, Move Data switches HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 249 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 250
56 conventions document 18 creating storageset and device profiles 75 creating and tuning 250 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 251
failover mode 50 disabling access paths 51 separate links 50 host adapter installation 104 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 251 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 252
UNITcommand 47 CLI configuration procedure fabric topology 180 fabric topology configuration cabling 139 252 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 253
89 maximum membership 83 planning considerations 81 important points 82 switches 88 read caching HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide Index 253 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 254
-enclosure subsystem 211 Storage map template 8 first enclosure of multiple-enclosure subsystem 212 254 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 255
to host connections 45 restricting host access 50 disabling access paths 51 separate links 50 restricting host access by offsets 52 SET CONNECTIONS 45 troubleshooting invalid network port assignments 221 there is no disk in the drive message 222 tuning file system 113 U uninstalling Client 225 unit - HP StorageWorks EMA12000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 256
38 write-back caching general description 37 write-through caching general description 37 256 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Installation
and
Configuration
Guide
HP
StorageWorks
HSG80 ACS Solution Software
V8.8
for Sun Solaris
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA-RV1RA-TE
This guide provides installation and configuration instructions and reference material for
operation of the HSG80 ACS Solution Software V8.8-1 for Sun Solaris.