HP StorageWorks EMA12000 HP StorageWorks HSG80 Enterprise Modular Storage RAID
HP StorageWorks EMA12000 Manual
View all HP StorageWorks EMA12000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks EMA12000 manual content summary:
- HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 1
Release Notes HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell NetWare Product Version: 8.8-1 First Edition and other HSG80 documentation, visit the HP storage web site at http://h18006.www1.hp.com/products/storageworks/acs/documentation.html - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 2
in this document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 3
and Fixes, page 10 ■ Solution Software Updates, page 28 ■ Documentation Updates, page 29 ■ Hardware and Software Support, page 31 ■ ACS Feature Support, page 34 ■ Avoiding Problem Situations, page 35 ■ Host Operating System Notes, page 36 ■ ACS Anomalies, page 38 Release Notes Contents HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 4
Audience This document is intended for storage administrators and HP StorageWorks customer service personnel who install and maintain HP StorageWorks Enterprise Modular Storage RAID Array products that include HP StorageWorks HSG80 RAID Array Controllers. Conventions The following conventions are - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 5
Area Network ■ SBB-Storage Building Block ■ SCSI-Small Computer System Interface ■ SMART-Self-Monitoring Analysis and Reporting Technology ■ SWCC-StorageWorks Command Console ■ VCS-Virtual Controller Software ■ WWID-World Wide Identifier ■ WWN-World Wide Name HSG80 Enterprise Modular Storage RAID - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 6
HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 - HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide, EK-G80TS-SA. C01 - Registration and Warranty Package - HSG80 Enterprise Modular - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 7
Contents The following supporting documentation is available from the HP StorageWorks web site: http://h18006.www1.hp.com/products/storageworks/acs/documentation.html ■ HP StorageWorks SAN Design Reference Guide ■ Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide ■ Model 4300 Family - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 8
follow upgrade instructions and perform the after-upgrade maintenance checks as documented in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide to prevent data loss or corruption. If at any time you encounter problems during the upgrade - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 9
V8.8-1. New Features for Solution Software V8.8-1 The following major enhancement is included in the V8.8-1 release of the Solution Software Kit: ■ Added support for NetWare V6.5. HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell 9 NetWare Release Notes - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 10
the HP StorageWorks HSG Element Manager and HP StorageWorks Command Console manually disable connections. Combines several existing commands to allow you to output and transfer relevant and helpful controller configuration information needed by HP service representatives before and during a support - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 11
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 4. CLI Command or Switch HOST_REDUNDANT NOHOST_REDUNDANT Description and Background Turns on and off the capability to redirect the host to the redundant unit copy for the original requested unit data after the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 12
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 5. DESTROY_MBR Description and Background Removes the 8 MB partition from a presented LUN and destroys the master boot record (MBR) present on new or replacement spares, HP-manufactured - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 13
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 6. FAKE_PR Description and Background Note: Use the FAKE_PR switch for maintenance or recovery operations only. If set on a unit, allows the controller to signal to host systems - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 14
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 7. REINITIALIZE container-name Description and Background Invokes maintenance actions against initialized containers and modifies container metadata. Also modifies the prior device - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 15
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 8. CLI Command or Switch REINITIALIZE container-name TURNSAVEOFF 9. REINITIALIZE container-name SPECIAL_FUNCTION_ONE=INFO Description and Background Disables the option to save configuration information for - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 16
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 10. CLI Command or Switch REINITIALIZE container-name SPECIAL_FUNCTION_ONE= PARTITION Description and Background Directs the controller to set the partition flag bits on all devices in a container and establishes - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 17
Recommended, or REPORTED ON THE OTHER CONTROLLER. Note: Refer to Chapter 4 of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for additional details related to this command. HSG80 Enterprise Modular Storage RAID Array Fibre Channel - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 18
code (6A) prompts you to use specific steps to resolve the problem associated with exceeding the maximum number of host connections. Refer to the HP StorageWorks Array Controller and Array Controller Software Troubleshooting Guide for additional details. New ASC and ASCQ code The following table - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 19
reporting technology) attribute on disk drives used in HSG60 and HSG80 array controller subsystems. Configuration changes to disk drive SMART attributes now support HP standards. SMART events are now only reported as recovered errors and are reported to the host during normal I/O operations. HSG80 - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 20
V8.6-1 (the base version). No other versions are supported. With this, changes have been made to associated screens. Refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for additional information. Note: If you are downgrading ACS - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 21
mounted by Tru64 UNIX (that is, units mounted by another supported operating system). New Display Information After Entering the DISPLAY RESOURCES detail in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide. HSG80 Enterprise Modular Storage - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 22
events in the controller non-volatile memory (NVMEM). Displays pertinent information relative to a controller crash and can be used by an HP service representative to help identify the cause of a controller crash. This command invokes the SHOW LAST ALL FULL FMU command. 22 HSG80 Enterprise Modular - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 23
failover 2. New LFC OE199001 and updates to Repair Code 90 Description The problem involving the loss of the initiator WWID on remote copy set (RCS) units with this issue was recursive. Repair Code 90 has updated troubleshooting steps to handle the following Recursive Bugcheck error scenarios: - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 24
drive error handling improvement Description Occasionally, recursive controller inoperability problems propagated to the bottom controller during FRUTIL operations in HP StorageWorks Continuous Access. Follow these steps to troubleshoot the above Recursive Bugcheck error scenarios: 1. On "the other - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 25
send and receive diagnostic commands to the controller and resulting in LFC 64030104 has been resolved. The issue involving controller inoperability problems while using FRUTIL which resulted in LFC 018F2087 has been resolved. An issue involving a controller inoperability event, as a result of an - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 26
If there is an error noted when this is attempted, refer to the REINITIALIZE command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for help. The RUN CONFIG command has been improved and now skips bad disk drives after the - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 27
ACS Enhancements and Fixes Table 4: ACS fixes (Continued) Item 24. Subject Fibre Channel (FC) switch goes port INSYNC state to HSG Description Previous to this release, resource leaks occurred if a controller processed PLOGI frames against the rejected host list while the connection table was - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 28
Notes. ■ Added support for NetWare V6.5. ■ Solution Software V8.8-1 does not support HP StorageWorks 32-bit FC HBA 223180-B21 and HP StorageWorks 64-bit FC Solution Software V8.8-1 for Novell NetWare Installation and Configuration Guide for replacement options. 28 HSG80 Enterprise Modular Storage - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 29
with the Fibre Channel Switch Support table. Switch support information is available in the HP StorageWorks SAN Design Reference Guide at http://h18006.www1.hp Software Maintenance and Service Guide, HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide, or HSG60 and - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 30
Documentation Updates - Moving Storagesets 30 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell NetWare Release Notes - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 31
.www1.hp.com/products/storageworks/softwaredrivers/acs/ 2. Select the manuals (guides, supplements, addendums, etc) link under self-help resources. 3. Select the HSG60, HSG80, HSJ80, HSZ80 Supported Disk Drive Matrix link. Switch Support This Fibre Channel Solution Kit supports the Fibre Channel - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 32
-X FC HBA FCA2214 (281541-B21), HBA driver V6.8f, BIOS1.45 HP StorageWorks 32-bit, 1 Gbps PCI FC HBA 223180-B21, HBA driver CPQFC HAM V2.54, Firmware Version N/A Note: This HBA is supported on NetWare V5.1 and 6.0 only. HP StorageWorks 64-bit, 1 Gbps PCI FC HBA 120186-B21, HBA driver CPQFC HAM - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 33
Hardware and Software Support Note: For more information on Secure Path software, refer to the product documentation that comes with the product, or visit the HP StorageWorks web site http://h18006.www1.hp.com/products/sanworks/secure-path/index.html Layered Software Applications Compatibility - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 34
ACS Feature Support ACS Feature Support The following sections provide details for specific ACS features. SCSI-2 to SCSI-3 Migration In order to extend interoperability within the heterogeneous SAN, HP highly recommends - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 35
Guide. Avoiding Problem Situations Under certain conditions, you may experience unusual array controller behavior. This section presents information to help you avoid such situations and to recover from them if they occur. Establishing an SWCC SCSI Connection SWCC is not supported - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 36
. Note: Virtual Disk Wizard in multi-bus failover mode is not supported with the Secure Path driver. Mounting a Clone Before mounting a Clone system. Having two identical NetWare Volume Names on the same system can cause problems. NetWare does not allow you to mount a Snapshot on the same server - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 37
Host Operating System Notes SCSI-3 Mode SCSI-3 Mode is now supported under NetWare. NSS Partitions NSS partition creation is supported by this Solution Software under NetWare. HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Novell 37 NetWare Release Notes - HP StorageWorks EMA12000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID - Page 38
ACS Anomalies ACS Anomalies If you issue the INITIALIZE SAVE_CONFIGURATION CLI command on a JBOD disk to save the controller configuration while the unit is not above the container, the command appears to work, but the save operation does not occur. You must place the unit above the JBOD, and then
Release Notes
HP StorageWorks
HSG80 Enterprise Modular
Storage RAID Array Fibre Channel
Solution Software V8.8
for Novell NetWare
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA
–RV1NA–TE
This document contains last-minute and supplemental information about your Solution Software. In
the event of conflicting information between these Release Notes and other documents contained in
this product release, the Release Notes content takes precedence. For the latest version of these
Release Notes and other HSG80 documentation, visit the HP storage web site at