Addendum HP StorageWorks HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80 Array Controllers Product Version: . For the latest version of this Addendum and other product documentation, visit the StorageWorks web site at http://www.compaq.com/storage/index.html - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 2
© Hewlett-Packard Company, 2000-2005. All rights reserved. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Hewlett-Packard shall not be liable for errors - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 3
HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide, EK-G80CL-RA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 HSG80 Addendum for ACS Solution Software V8 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 4
Troubleshooting Guide, EK-G80TS-SA. C01 ■ SWCC v2.5 documentation (Client software delivered in solutions kits) ■ HP StorageWorks HP StorageWorks Command Console Version 2.5 User Guide, AA- RV1UA -TE ■ HP StorageWorks HP StorageWorks host support includes the following platforms: - IBM AIX - HP-UX - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 5
■ Secure Path Products (Windows, NetWare, Sun, AIX, HP-UX) ■ Data Replication Manager (DRM) under ACS 8.8- Ended SCSI buses. They are used in the MA8000 and EMA12000 Fibre Channel storage systems. The solution also contains the latest version of StorageWorks Command Console (SWCC) software. Figure - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 6
of the Array Controller Software, used with HSG60 and HSG80 controllers, include: ■ Up to 146GB drives in a 1-inch form factor ■ An increased number of maximum supported host connections from 64 to 96 ■ 14 drives on a single SCSI bus ■ 84 total drives behind one controller pair with six fully loaded - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 7
■ SET_DRM ■ SET_REMOTE_COPY_SET_NAME ■ SET_SITE_FAILOVER All other CLI commands described in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide work with either HSG80 or HSG60 array controllers. Layered Software Applications - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 8
Saving HSG60 Configurations to Previously Initialized Storagesets 1. This application is supported by IBM AIX, HP-UX, OpenVMS, Sun Solaris, Tru64 UNIX, and Windows. 2. This application is supported by IBM AIX, Novell Netware, OpenVMS, Sun Solaris, Tru64 UNIX, and Windows. For more information on - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 9
an ACS upgrade from ACS V8.6 to V8.8 on IBM AIX systems. Rolling Upgrade Limitation, HSG60 and HP-UX For HSG60 controller configurations, HP-UX does not support rolling upgrades. HP-UX in a HSG60 controller configuration is limited to SCSI-2 only and loop only. HSG80 Addendum for ACS Solution - HP StorageWorks EMA16000 | HP StorageWorks HSG80 Addendum for ACS Solution Softw - Page 10
Disk Drives HSG60 Supported Disk Drives Patches for ACS and a link to the supported disk drives for the HSG60 are located at http://h18006.www1.hp.com/products/storageworks/softwaredrivers/acs/. 10 HSG80 Addendum for ACS Solution Software V8.8 Differences Between HSG60 and HSG80 Array Controllers
Addendum
HP StorageWorks
HSG80 Addendum for ACS
Solution Software V8.8
Differences Between HSG60 and HSG80
Array Controllers
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AV-RV2MA-TE
This document describes the differences between HSG60 and HSG80 array controllers. For the
latest version of this Addendum and other product documentation, visit the StorageWorks web
site at