- HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 1
Installation and Configuration Guide HP StorageWorks HSG80 ACS Solution Software V8.8 for IBM AIX Product Version: 8.8-1 First Edition (March 2005) Part Number: AA-RV1HA-TE This guide provides installation and configuration instructions and reference material for operation of the HSG80 ACS Solution - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 2
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting V8.8 for IBM AIX Installation and Configuration Guide First Edition (March 2005) Part Number: AA-RV1HA-TE - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 3
contents Contents About this Guide 11 Overview 12 Intended Audience 12 Related Documentation 12 Chapter Content Summary 14 Conventions 16 Document Conventions 16 Symbols in Text 16 Symbols on Equipment 17 Rack Stability 19 Getting Help 20 HP Technical Support 20 HP Storage Web Site 20 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 4
81 Mirrorset Planning Considerations 82 Keep these points in mind when planning mirrorsets 83 4 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 5
Upgrading Solution Software 118 Removing the Solution Software 120 Solution Software Upgrade Procedures 121 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 5 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 6
155 Configuring a Striped Mirrorset 156 Configuring a Single-Disk Unit (JBOD 157 Configuring a Partition 157 6 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 7
Snapshot 184 Delete Snapshot 185 Recreate Volume Group of a Snapshot 185 Show Disks with the Same Physical Volume ID 185 Recreate Volume Group 185 Manual Snapshot/Clone Creation 186 Moving Storagesets 191 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 7 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 8
Insight Manager Unable to Find Controller's Storage Window 220 Troubleshooting Client Installation 222 Invalid Network Port Assignments During Installation Information 228 About the User Guide 228 About the Online Help 228 C HACMP Notes for AIX 229 Supported Versions of HACMP 229 Installing - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 9
increases request rate 94 33 Dual-bus enterprise storage RAID array storage system 106 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 9 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 10
14 Correct controller parameter settings 137 15 Correct controller parameter settings, AIX 147 10 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 11
■ Plan the storage array subsystem. ■ Install and configure the storage array subsystem on individual operating system platforms. "About this Guide" topics include: ■ "Overview", page 12 ■ "Chapter Content Summary", page 14 ■ "Conventions", page 16 ■ "Rack Stability", page 19 ■ "Getting Help", page - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 12
StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide, EK-G80TS-SA. C01 ■ SWCC v2.5 documentation (Client software delivered in - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 13
About this Guide Solution software host support includes the following platforms: - IBM AIX - HP-UX - Linux (Red Hat x86, SuSE x86) - Novell NetWare - Open VMS - Sun Solaris - Tru64 UNIX - Windows NT/2000/Windows Server 2003 (32-bit) Additional support required by HSG80 ACS Solution Software V8.8-1, - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 14
About this Guide Chapter Content Summary Table 1 below summarizes the content of the chapters. Table 1: Summary of chapter contents Chapters 1. Planning a Subsystem using the Command Line Interpreter (CLI). 14 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 15
of common procedures that are not mentioned elsewhere in this guide. ■ Backing Up Subsystem Configuration ■ Cloning Data for Backup the Client ■ Installing the Client ■ Installing the Integration Patch ■ Troubleshooting Client Installation ■ Adding Storage Subsystem and its Host to the Navigation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 16
(output and messages) Command-line and code variables Web site addresses Symbols in Text The following symbols may be found in the text of this guide. They have the following meanings: WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 17
following equipment symbols may be found on hardware for which this guide pertains. They have the following meanings: Any enclosed surface or the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 18
About this Guide Power supplies or systems marked with these symbols indicate the presence of to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. 18 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 19
About this Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal injury or damage to the equipment, be than one rack component is extended for any reason. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 19 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 20
still have a question after reading this guide, contact an HP authorized service provider or access our web site http://www.hp.com. HP Technical Support Telephone numbers for worldwide technical support are listed on the following HP web site http://www.hp.com/support/. From this web site, select - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 21
About this Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, web site for locations and telephone numbers http://www.hp.com. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 21 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 22
on the following pages. Refer to these charts while installing and configuring a new storage subsystem. All references in the flowcharts pertain to pages in this guide, unless otherwise indicated. 22 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 23
About this Guide Unpack subsystem See the unpacking instructions on shipping box Plan a subsystem Chapter 1 Plan storage configurations Chapter 2 Prepare host system General configuration flowchart (panel 1) HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 23 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 24
About this Guide A Configure devices page 152 Continue creating units until you have you have completed your planned configuration. Create storagesets and 164 Figure 2: General configuration flowchart (panel 2) 24 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 25
About this Guide B Install Agent Chapter 4 Install Client Appendix B Create storage See SWCC online help Verify storage setup page 164 Figure 3: Configuring storage with SWCC flowchart (panel 3) HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 25 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 26
About this Guide 26 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 27
delete the 8 MB EISA partition. Refer to HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for details. Refer to Chapter 2 when planning the types of storage containers you need. Storage containers are individual disk drives (JBOD - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 28
module CXO7365A B Figure 4: Location of controllers and cache modules in a Model 2200 enclosure 28 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 29
"other controller" in a Model 2200 enclosure. Figure 7 shows the same relationship in a BA370 enclosure. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 29 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 30
2 This controller CXO6468D Figure 7: "This controller" and "other controller" for the BA370 enclosure 30 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 31
of failover can work with loop or fabric topology. Note: Multiple-bus failover mode is only supported when Secure Path is used. Refer to the Secure Path documentation for more information on using multiple link. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 31 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 32
for failures of either the Fibre Channel link or host Fibre Channel adapters. 32 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 33
D120 Host port 1 standby Controller B Host port 2 active Figure 8: Transparent failover-normal operation CXO7036A HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 33 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 34
■ Each host has two or more paths to the units All hosts must have operating system software that supports multiple-bus failover mode. With this software, the host sees the same units visible through two (or more HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 35
-bus failover mode, you can specify which units are normally serviced by a specific controller of a controller pair. Units can between the controllers ■ All hosts must have operating system software that supports multiple-bus failover mode HSG80 ACS Solution Software V8.8 for IBM AIX Installation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 36
2 active NOTE: FCA = Fibre Channel Adapter Figure 10: Typical multiple-bus configuration CXO7094B 36 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 37
Planning a Subsystem Selecting a Cache Mode The cache module supports read, read-ahead, write-through, and write-back caching techniques. The cache technique is selected or an uninterruptible power supply). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 37 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 38
is stored in-the cache memory on its way to the disk drives. 38 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 39
: Mirrored caching Before enabling mirrored caching, make sure the following conditions are met: ■ Both controllers support the same size cache. ■ Diagnostics indicate that both caches are good. ■ No unit errors are HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 39 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 40
an actual LUN, the SHOW UNITS command does not display the CCL location. 40 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 41
an active host port on a controller. Note: In ACS V8.8-1, the maximum number of supported connections is 96. Naming Connections It is highly recommended that you assign names to connections that have characters. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 41 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 42
-bus failover mode, each adapter has two connections, as shown in Figure 14. 42 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 43
= Fibre Channel Adapter CXO7081B Figure 12: Connections in separate-link, transparent failover mode configurations HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 43 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 44
Channel Adapter CXO7079B Figure 13: Connections in single-link, transparent failover mode configurations 44 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 45
NOTE: FCA = Fibre Channel Adapter Figure 14: Connections in multiple-bus failover mode CXO7080B HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 45 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 46
1 have a default offset of 0 and connections on port 2 have a default offset of 100. 46 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 47
the unit's range (unit number of 127 minus offset of 128 is a negative number). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 47 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 48
Start Unit command to move the unit from one controller to the other. 48 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 49
assigned at connection offsets (so that every host connection has a unit presented at LUN 0). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 49 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 50
offsets What the connection sees LUN 0 as Unit whose number matches offset CCL 50 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 51
the access path of selected host connections on a shared loop or fabric ■ Setting offsets HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 51 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 52
the following section "Restricting Host Access by Disabling Access Paths" on page 53. 52 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 53
for each unit. Default access enables the unit to be accessible to all hosts. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 53 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 54
the potential data/security breach that occurs when a new host connection is added. 54 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 55
and the host must be enabled in order for multiple-bus failover to work. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 55 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 56
the connections to host BLUE. At least two connections must be enabled for 56 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 57
host connections to the same host computer must be set to the same offset. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 57 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 58
-EE01 ■ Controller A and controller B, port 2-worldwide name + 2, for example 5000-1FE1-FF0C-EE02 58 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 59
) 2 Checksum Figure 18: Placement of the worldwide name label on the Model 2200 enclosure HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 59 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 60
the unit is reinitialized. Use the SHOW command to list the LUN ID. 60 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 61
page 91 ■ "Specifying Initialization Switches", page 93 ■ "Specifying Unit Switches", page 97 ■ "Creating Storage Maps", page 98 Refer to Chapter 3 for instructions on how to prepare your host computer to accommodate the HSG80 controller storage subsystem. HSG80 ACS Solution Software V8.8 for IBM - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 62
one of the following methods: - Use SWCC. See the SWCC documentation for details. 62 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 63
you flexibility in defining and naming your storage containers. See the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 64
-critical data? Is availability the highest priority or would standard backup procedures suffice? 64 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 65
devices per RAID 0 storageset (stripeset) ■ 48 physical devices per RAID 0+1 storageset (striped mirrorset) ■ 146 GB disks (for universal drives only) are the largest supported for the HSG60 and HSG80 storage array. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 66
new container before proceeding with subsystem activities to avoid operational and performance issues. 66 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 67
-redundant controller configuration are 0-3 and 8-15, respectively. (This applies to the BA370 cabinet only.) HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 67 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 68
set through the PVA module. Enclosure ID number 1, which assigns devices to targets 4 through 7, is not supported. Figure 22 shows how data is laid out on disks in an extended configuration. Operating system view Virtual disk Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 69
above the controller enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 69 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 70
Disk61000 Disk61100 Disk61200 Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 70 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 71
Disk20800 Disk21000 Disk21100 Disk21200 Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 71 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 72
ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 72 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 73
Disk10000 Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk10900 Disk11000 Disk11100 Disk11200 Disk11300 Disk11400 Disk11500 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 73 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 74
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 74 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 75
Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 75 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 76
Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 23: Storage container types CXO667 76 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 77
a comprehensive discussion of RAID, refer to The RAIDBOOK-A Source Book for Disk Array Technology. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 77 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 78
) Read Source ___Least busy (default) ___Best fit ___Fast ___Round robin ___None ___Disk drive: 78 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 79
hosts enabled Read caching_______X__ Read-ahead caching_____ Write-back caching___X__ Write-through caching____ _ALL HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 79 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 80
Disk 10100 Chunk 1 4 25 Figure 24: Three-member RAID 0 stripeset (example 1) 36 CXO7287A 80 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 81
and high availability, consider using a RAIDset, striped-mirrorset, or a host-based shadow of a stripeset. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 81 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 82
for storing data that can be reproduced easily or whose loss does not prevent the system from supporting its critical mission. ■ Evenly distribute the members across the device ports to balance the load mirrorset. 82 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 83
availability is your top priority, consider using dual-redundant controllers and redundant power supplies. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 83 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 84
data availability. Figure 28 shows an example of a RAIDset that uses five members. 84 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 85
systems from working with large RAIDsets. ■ Both cache modules must be the same size. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 85 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 86
data availability. Figure 30 shows a second example of a striped mirrorset using six members. 86 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 87
mirrorset (example 2) Disk 5 Block 2 Block 5 Block 8 Disk 6 Block 2 Block 5 Block 8 Virtual disk #3 Mirrorset CXO6462A HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 87 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 88
and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide describes the CLI command, ADD CONCATSETS, which is used to Use the ADD CONCATSETS command only with host operating systems that support dynamic volume expansion. Use of this command could result in inacessible - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 89
are separately addressable storage units; therefore, you can partition a single storageset to service more than one user group or application. Defining a Partition Partitions are expressed as about cloning.) HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 89 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 90
to enable each switch if you use CLI commands to configure the storageset or device manually. The HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide contains the details of the CLI commands and their switches. Changing Switches You can change - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 91
and SET RAIDset-name commands in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. Mirrorset Switches Use the following switches to control how a mirrorset behaves to ensure data availability: ■ Replacement policy ■ Copy speed ■ Read - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 92
the use of these switches, refer to CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. 92 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 93
request size determines whether striping increases the request rate or the data-transfer rate. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 93 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 94
not know, use a chunk size of 15 times the average transfer request rate. 94 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 95
command shows which disks are used to backup configuration information. Note: DO NOT use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 96
of a mirrorset. See the REDUCED command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide for information on removing disk drives from a mirrorset. NODESTROY is ignored for members of a RAIDset. Geometry The geometry parameters of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 97
under the SET unit-number command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. One unit switch, ENABLE/DISABLE_ACCESS_PATH, determines which host connections can access the unit, and it is described in the larger topic of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 98
R1. 3. Enter the following command to turn off the flashing LEDs: LOCATE CANCEL 98 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 99
named M7. M7 consists of Disk11200 and Disk21200. ■ Disk31200 and Disk41200 are spareset members. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 99 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 100
M5 DISK ID Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk21000 Disk21100 Disk21200 100 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 101
M6 10 12 spare Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 101 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 102
Planning Storage Configurations 102 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 103
", page 104 ■ "Making a Physical Connection", page 108 ■ "HP StorageWorks Solution Software Installation", page 110 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 103 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 104
use the disk enclosure handles to lift the enclosure. The handles cannot support the weight of the enclosure. Only use these handles to position the enclosure SCSI Controller Enclosures User Guide and the HP StorageWorks Model 4300 Family Ultra3 LVD Disk Enclosures User Guide for further information. - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 105
unused bays. Fibre Channel cabling information is shown to illustrate supported configurations. In a dual-bus disk enclosure configuration, disk enclosures dual-bus system and Figure 34 for a single-bus system. Note that the supported cable lengths are 1, 2, 3, 5, and 10 meters. 7. Connect the AC - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 106
Channel Ports Figure 33: Dual-bus enterprise storage RAID array storage system CXO7383A 106 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 107
6 Cable 8 Fibre Channel Ports Figure 34: Single-bus enterprise storage RAID array storage system HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 107 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 108
bus adapter board and the installation instructions included with the adapter ■ The HP StorageWorks software installation kit ■ The computer hardware manual ■ Appropriate tools to service your computer The host bus adapter ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 109
each IBM host server in the cluster. For further information on HACMP, see Appendix C. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 109 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 110
the output of the installation script. Notes and explanations have been added. # ./INSTALL 110 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 111
OK Issuing bosboot command...OK Next, entries to ODM database are added so that the OS supports both HSG60 and HSG80 controller-based subsystems. Since this is a new installation, the installation Continue--- HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 111 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 112
to use this script! Current user is root. Do you wish to continue? [Y,n]: 112 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 113
Windows NT 4.0, Windows 2000, or Windows Server 2003 and it must use a fixed IP address that is resolvable through DNS or NIS. Here is the guide to the meaning of the communication and monitoring options. The Access Privilege options are: ■ 0-The Client can only view the main storage window; it - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 114
: 2 error notification: 3 Is this information correct? [Y,n] Would you like to add another client? [y,N] 114 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 115
, in secs (0 => no monitoring, default is 300): Would you like to add another subsystem? [y,N] HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 115 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 116
is sent. 3-Notification for serious errors, warning messages, and informational messages is sent. 116 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 117
& Fatal Errors -- Hit RETURN to continue The STEAM Agent package has been successfully configured. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 117 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 118
HSG60 and/or HSG80 ODM entries. ■ Upgrade the build of the SWCC Agent. 118 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 119
any previously exported volume groups. ■ Mount any previously mounted filesystems to upgrade the driver. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 119 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 120
.rte: create disk snapshots swcc.rte: SWCC agent hsg80.rte: HSG80 device support hsg60.rte: HSG60 devices support PC1000.driver.obj (optional): Cambex adapter driver Before you execute this uninstall, be 120 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 121
the purpose of performing upgrades to the ACS firmware, this Solution Software Kit supports previous ACS V8.6 and 8.7. It is recommended that you do not HSG80 Array Controller and Array Controller Software Maintenance and Service Guide and the Solution Software Release Notes for the latest - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 122
Preparing the Host System 122 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 123
Chapter 5 for a description of how to configure a subsystem that uses Fibre Channel fabric topology. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 123 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 124
pager notification and lets you manage your virtual disks. The Client runs on Windows 2000 with Service Pack 4, Windows NT 4.0 with Service Pack 6A or above, and Windows Server 2003 (32-bit). ■ The Agent obtains the HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 125
Installing and Configuring HSG Agent Note: For serial and SCSI connections, the Agent is not required for creating virtual disks. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 125 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 126
your hardware has been set up correctly. See the previous chapters in this guide. Verify that you have a network connection for the Client and Agent systems Agent. Install the Client software on Windows 2000 with Service Pack 4 or Windows NT 4.0 with Service Pack 6A, and Windows Server 2003 (32-bit). - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 127
on the LAN. If you have a WAN or a connection to the Internet, monitor the subsystem with TCP/IP. Note: SWCC does not support the dynamic host configuration protocol (DHCP) or the Windows Internet Name Service (WINS). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 128
controller and its device subsystem 7 Servers Figure 35: An example of a network connection 128 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 129
Log File The Agent logs any subsystem events in /var/adm/ras/steamd.log. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 129 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 130
any storage window and configure any RAID array on the current host system 130 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 131
address. ■ Toggle Mail Notification-Enable or disable email notification if there is a subsystem event. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 131 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 132
Installing and Configuring HSG Agent 132 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 133
. To install a controller or cache module and the PCMCIA card, see the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 134
maintenance port cables when not communicating with the controller through the local connection. 134 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 135
switch as part of the configuration procedure ("Configuring a Single Controller Using CLI", page 136). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 135 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 136
, enter: SHOW THIS_CONTROLLER FULL The current configuration of your RAID HSG80 controller opens. 136 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 137
Controller 5. To set the prompt to the HSG80 controller, enter: SET THIS_CONTROLLER PROMPT="HSG>" HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 137 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 138
use setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. HSG> SET ! Software Command Line Interface Reference Guide. 138 HSG80 ACS Solution Software V8.8 for IBM AIX Installation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 139
> SET THIS_CONTROLLER PORT_2_TOPOLOGY=FABRIC See Table 14 for an example of LOOP_HARD topology setup. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 139 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 140
setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. If Array Controller and Array Controller Software Command Line Interface Reference Guide. 23. Restart the controllers for the new settings to - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 141
THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for the format of optional settings. 4. Verify that all commands have taken effect. Use the following command: HSG> SHOW THIS Verify - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 142
seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 142 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 143
connection, use the setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. The first connection has one or more HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 143 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 144
connection, use the setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. 9. Verify the changes: SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 145
hub as part of the configuration procedure ("Configuring a Controller Pair Using CLI", page 146). HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 145 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 146
connection to RAID system Controller A from your host. 2. From the CLI prompt, enter: 146 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 147
Restart Controller messages until you have finished making all the required configuration parameter changes. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 147 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 148
in the CLI and SWCC, for the fibre channel connection, use setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. HSG> SET !NEWCONxx OPERATING_SYSTEM=AIX_CAMBEX where: xx is the online connection ID - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 149
THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for the format of optional settings. Perform this step on both controllers. 17. Verify that all commands have taken effect by entering - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 150
seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 150 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 151
connection, use the default setting AIX_CAMBEX for operation with your IBM host. The IBM setting may cause problems when LUNs are not available to AIX or during controller failover. 23. Verify the changes: HSG > HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 151 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 152
Configuration Procedures Configuring Devices The disks on the device bus of the HSG80 can be configured manually or with the CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following system. 152 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 153
(R0) Storagesets Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 39: Storage container types HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 153 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 154
the ADD MIRRORSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the mirrorset switches. 2. Initialize the mirrorset, specifying any desired switches: INITIALIZE MIRRORSET-NAME SWITCHES See - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 155
ADD RAIDSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the RAIDset switches. 2. Initialize the RAIDset, specifying any desired switches: INITIALIZE RAIDSET-NAME SWITCH Note: HP recommends - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 156
MIRR3 DISK10200 DISK20200 ADD STRIPESET STRIPE1 MIRR1 MIRR2 MIRR3 INITIALIZE STRIPE1 SHOW STRIPE1 156 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 157
: See the CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the partition switches. 3. Verify the partitions: SHOW STORAGESET-NAME HSG80 ACS Solution Software V8.8 for IBM AIX - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 158
DISK30000 INITIALIZE RAID1 CREATE_PARTITION RAID1 SIZE=25 CREATE_PARTITION RAID1 SIZE=LARGEST SHOW RAID1 158 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 159
under the ADD UNIT command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide. Because of different SCSI versions, refer to the section "Assigning Unit Numbers Depending on SCSI_VERSION", page 49. The choice for SCSI_VERSION - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 160
the controller should it need to replace a failed member of a RAIDset or mirrorset. 160 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 161
disk drive is automatically initialized and placed into the spareset. If initialization fails, the disk drive remains in the failedset until you manually delete it from the failedset. To enable autospare, use the following command: SET FAILEDSET AUTOSPARE HSG80 ACS Solution Software V8.8 for IBM - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 162
associated with it. Remember to update the storageset profile when changing its switches. 162 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 163
. For example, the following command enables write protection for unit D100: SET D100 WRITE_PROTECT HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 163 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 164
), to make volume groups, logical volumes and file systems using these logical units. 164 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 165
in Chapter 2. Templates to help you build your storage map are supplied in Appendix A. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 165 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 166
is. For example, if the disk number is disk10200, 2 is the target number. 166 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 167
43 represents an example of virtual system layout from the hosts' point of view. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 167 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 168
that is displayed by the CLI interpreter. Note: "This" controller is top controller (A). 168 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 169
Plug in the Fibre Channel cable from the adapter in host "PURPLE." SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 169 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 170
!NEWCONO1 is automatically set to 100 because it is plugged into host port 2. 170 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 171
OL this 100 XX HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXX X-XXXX HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 171 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 172
this 100 XX HOST_ID=XXXX-XXXX-XXXX-XXXX ADAPTER_ID=XXXX-XXXX-XXX X-XXXX 172 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 173
RENAME !NEWCON02 TAN1B2 SET TAN1B2 OPERATING_SYSTEM=AIX_CAMBEX SET TAN1B2 UNIT_OFFSET=120 SHOW CONNECTIONS Using CLI for Configuration HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 173 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 174
=XXXX-XXXX-XXX X-XXXX Mark or tag both end of Fibre Channel cables. 174 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 175
D101 DISK50300 DISABLE_ACCESS_PATH=ALL SET D101 ENABLE_ACCESS_PATH=(WHITE1B2) ADD SPARESET DISK60300 SHOW UNITS FULL HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 175 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 176
Using CLI for Configuration 176 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 177
", page 179 ■ "Clone and Snapshot and AIX Environment", page 183 ■ "Moving Storagesets", page 191 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 177 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 178
is backed up. Note: DO NOT use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. The SHOW DEVICES FULL command shows which disk drives are ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 179
complete, you can back up the Clones rather than the storageset or single-disk unit, which can continue to service its I/O load. When you are cloning a mirrorset, Clone does not need to create a temporary mirrorset. ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 179 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 180
you want to use for the Clone units. 7. Back up the Clone unit. 180 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 181
=2 SET C_MB REPLACE=DISK20300 COPY IN PROGRESS FOR EACH NEW MEMBER. PLEASE BE PATIENT... . HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 181 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 182
C_ST1 D99 HAS BEEN CREATED. IT IS A CLONE OF D98. CLONE - NORMAL TERMINATION 182 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 183
two sections that follow. The first describes the Snapshot tools that are included with the solution software. The second is a description of how to manually create a Snapshot and redefine the volume group for use with AIX. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 184
have reached the maximum allowed number of Snapshots. ■ There was a communications failure with the HSG80. Manual Snapshot This method of Snapshot creation allows you to choose the parameters you wish to use to create HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 185
. You choose a communications device the same way as you do to list the Snapshots units or create a manual Snapshot and then choose the unit number of the Snapshot that you wish to delete. The utility then deletes HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 185 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 186
Backing Up, Cloning, and Moving Data Manual Snapshot/Clone Creation To Clone or Snapshot drives within an AIX volume group, do the following: 1. Locate all physical volumes ( D1XX to which the hdisks are mapped. 186 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 187
CCL. The L value for hdisk6 is 1 therefore the RAID set unit number is D001. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 187 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 188
and the L value is 2, the RAID set unit number for hdisk5 is D102. 188 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 189
for copy in the storage system. 4. If the copy is to be a Snapshot, skip to Step 5, otherwise follow the Clone procedure described in this guide. Repeat the procedure for each target drive. As mentioned before, the hdisks associated with the storage system drives and targeted for Clone copy can - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 190
AIX command to import and activate the new hdisks into a volume group. Although Step 9 solves the PVID problem in importing the new hdisks as a volume group, there are still conflicts with the logical volume found on the Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 191
the release notes for the version of your controller software for information on which drives can be supported. Caution: Never initialize any container or this procedure does not protect data in the storageset. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 191 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 192
cabinet DELETE D100 DELETE RAID99 DELETE DISK10000 DELETE DISK10100 DELETE DISK20000 DELETE DISK20100 192 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 193
Backing Up, Cloning, and Moving Data New cabinet ADD DISK DISK10000 ADD DISK DISK10100 ADD DISK DISK20000 ADD DISK DISK20100 ADD RAIDSET RAID99 DISK10000 DISK10100 DISK20000 DISK20100 ADD UNIT D100 RAID99 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 193 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 194
Backing Up, Cloning, and Moving Data 194 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 195
Enclosure", page 210 ■ "Storage Map Template 9 for the Model 4354R Disk Enclosure", page 213 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 195 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 196
) ___ 64 blocks ___Yes ___Retain ___ 128 blocks ___ 256 blocks ___ Other: 196 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 197
Subsystem Profile Templates Unit Switches: Caching Access by following hosts enabled Read caching__________ Read-ahead caching_____ Write-back caching______ Write-through caching____ HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 197 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 198
D50100 D60100 Power Supply Power Supply D10000 D20000 D30000 D40000 D50000 D60000 2 Targets 1 0 198 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 199
D30900 D40900 D50900 D60900 Power Supply Power Supply 8 D10800 D20800 D30800 D40800 D50800 D60800 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 199 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 200
D51300 D61300 Power Supply Power Supply 12 D11200 D21200 D31200 D41200 D51200 D61200 200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 201
Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 201 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 202
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 202 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 203
Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 DISK ID continued on the following page HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 203 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 204
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 204 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 205
12 ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 205 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 206
ID DISK ID Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk21000 Disk21100 Disk21200 206 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 207
12 ID DISK ID Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 207 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 208
ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 208 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 209
12 ID DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 209 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 210
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk50900 Disk51000 Disk51100 Disk51200 Disk51300 Disk51500 Disk51500 210 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 211
Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 DISK ID HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 211 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 212
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 212 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 213
Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 213 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 214
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 214 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 215
217 ■ "Installing the Client", page 218 ■ "Installing the Integration Patch", page 219 ■ "Troubleshooting Client Installation", page 222 ■ "Adding Storage Subsystem and its Host to Navigation Tree", page 224 228 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 215 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 216
an individual device (JBOD) ■ Monitor many subsystems at once ■ Set up pager notification 216 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 217
the software product description that came with the software for a list of supported hardware. 3. Verify that you have the SNMP service installed on the computer. SNMP must be installed on the computer for this HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 217 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 218
you install both, but one at a time. This problem is not seen under Windows NT 4.0 Server. 2. Set instructions on the screen. After you install the software, the Asynchronous Event Service (AES) starts. AES is a service Guide. 218 HSG80 ACS Solution Software V8.8 for IBM AIX Installation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 219
integration patch uses some of the same files as the HSG80 Storage Window V2.1. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 219 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 220
the following procedure: 1. Double-click the Insight Agents icon (Start > Settings > Control Panel). A window is displayed showing you the active and inactive Agents under the Services tab. 220 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 221
Installing, Configuring, and Removing the Client 2. Highlight the entry for Fibre Array Information and click Add. The Fibre Array Information entry is moved from Inactive Agents to Active Agents. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 221 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 222
Troubleshooting Client Installation This section provides information on how to resolve some of the problems services (services file or for UCX, the local services database). If the SWCC installation finds an entry in the local services the network and added manually to the services file. There are - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 223
the floppy drive and a CD-ROM in the CD-ROM drive. Then, click Retry. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 223 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 224
the host name or its TCP/IP address and click Apply. 5. Click Close. 224 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 225
-click the Storage Window icon. Figure 47: Navigation window showing expanded "Atlanta" host icon HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 225 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 226
to HP StorageWorks Command Console V2.5 User Guide. Removing Command Console Client Before you . This prevents the system from reporting that a service failed to start every time the system is restarted /Remove. 6. Follow the instructions on the screen. 226 HSG80 ACS Solution Software V8.8 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 227
Installing, Configuring, and Removing the Client Note: This procedure removes only the Command Console Client (SWCC Navigation Window). You can remove the HSG80 Client by using the Add/Remove program. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 227 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 228
on how to use SWCC. Some of the topics in the user guide are the following: ■ About AES ■ Adding Devices ■ Adding Virtual Disks ■ Setting Up Pager Notification ■ How to Integrate SWCC with Insight Manager ■ Troubleshooting Information About the Online Help Most of the information about the Client - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 229
is the acronym for High Availability Cluster Multi-Processing. Only HACMP/ES 4.4.1.x and 4.5 are supported with the solution software. Installing Solution Software for AIX V8.8 on HACMP Cluster The installation HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 229 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 230
HACMP Notes for AIX just meant as guide to you. Consult your HACMP documentation for any changes on creating a shared volume group. Note that using C-SPOC for HACMP none none none rootvg none none none 230 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 231
the next available major number to use for a volume group: Output from brutus: 45... HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 231 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 232
of Free PPs - 1 because there needs to be 1 PP free to create a filesystem. 232 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 233
sharedvg The Virtual Disk is now ready to be added to your HACMP configuration. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 233 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 234
HACMP Notes for AIX 234 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 235
on a removable ROM program card that provides the operating system for the array controller. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 235 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 236
header. A method used to bring a system or device into a defined state by means of its own action. For example, a machine routine whose first few instructions are enough to bring the rest of the routine into the computer from an input device. 236 HSG80 ACS Solution Software V8.8 for IBM AIX - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 237
. Stripesets and mirrorsets are examples of storageset containers the controller uses to create units. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 237 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 238
, even though the host operation processing the data has completed. Direct Memory Access. 238 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 239
. The EMU also controls certain cabinet hardware including DOC chips, alarms, and fan speeds. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 239 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 240
Fibre Channel Fabric Generic Requirements Fibre Channel Framing Protocol (HIPPI on FC) Fibre Channel Generic Services-1 Fibre Channel Generic Services-2 Fibre Channel Implementation Guide Fibre Channel Link Encapsulation (ISO 8802.2) The Fibre Channel Physical and Signaling standard. Fibre Channel - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 241
block contains unrecoverable data. An invisible unit used to transfer information in Fibre Channel. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 241 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 242
heterogeneous host support HIPPI-FC host host adapter HBA Field replaceable unit. A hardware component that can be replaced at the customer location by service personnel or qualified customer service personnel. 242 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 243
error occurs. The instance code indicates when during software processing the error was detected. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 243 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 244
terminal. A single-ended bus connected to a differential bus by a SCSI bus signal converter. 244 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 245
detection and media defect management for the disk drive. It is also used to support storageset configuration and partitioning. Nontransportable disks also contain metadata to indicate they are image of data. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 245 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 246
the mirrorset. Read requests from the host are always satisfied by normal members. 246 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 247
participate in loop activities. A port must have a valid AL_PA to be in participating mode. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 247 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 248
that contains the controllers, cache modules, external cache batteries, and the PVA module. 248 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 249
information across all of the disk drives within the storageset. See also RAID level 3. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 249 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 250
background. Data warehousing, continuous computing, and enterprise applications all require remote copy capabilities. 250 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 251
remote controller is designated as the "target". The rate at which requests are arriving at a servicing entity. Radio frequency interference. The disturbance of a signal by an unwanted radio signal or frequency . HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 251 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 252
of storing data, whether it is a physical device or a group of physical devices. 252 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 253
each event to operate in relation to a timing signal. See also asynchronous. A storage device supporting sequential access to variable sized data records. (1) A SCSI device that performs an operation requested . HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 253 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 254
drive. A unit may also be created from a more complex container such as a RAIDset. The controller supports a maximum of eight units on each target. See also target and target ID number. Sometimes called unflushed HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 255
the cache memory accordingly, to ensure that the cache contains the most current data. HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 255 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 256
Glossary 256 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 257
topology 159 assignment of unit numbers fabric topology partition 159 single disk 159 asynchronous event service 228 audience 12 authorized reseller, HP 21 autospare enabling fabric topology 161 Index Index ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 257 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 258
fabric topology 162 configuration fabric topology 152, 153 creating a profile 78 disk drives 258 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 259
naming 41 Host storage configuration verify 164 HP authorized reseller 21 storage web site 20 technical support 20 HSG Agent install and configure 123 network connection 127 overview 126 I initialize switches 228 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 259 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 260
RAIDsets 91 initialize 93 other controller 29 P pager notification 228 configuring 228 partitions 260 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 261
of multiple-enclosure subsystem storage map template 2 199 selective storage presentation 51 SET CONNECTIONS HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide 261 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 262
configuration 95 subsystem configuration backup 178 SWCC 124 additional information 228 integrating 228 262 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 263
in text 25 symbols on equipment 17 T technical support, HP 20 templates subsystem profile 195 terminology other controller links 52 restricting host access by offsets 55 SET CONNECTIONS 46 troubleshooting invalid network port assignments 222 there is no disk in the and Configuration Guide 263 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 264
Index write-through caching general description 38 264 HSG80 ACS Solution Software V8.8 for IBM AIX Installation and Configuration Guide
Installation
and
Configuration
Guide
HP StorageWorks
HSG80 ACS Solution Software
V8.8
for IBM AIX
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA–RV1HA–TE
This guide provides installation and configuration instructions and reference material for
operation of the HSG80 ACS Solution Software V8.8-1 for IBM AIX.