need to be replaced, refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for specific instructions. A copy of this guide can be downloaded from the HP website at: http://h18006.www1.hp.com/products/storageworks/ acs/index.html - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 2
2 3 4 1 5 1 6 1 2 3 4 5 6 10 11 12 9 7 8 2 3 4 5 6 1 2 3 4 5 6 10 11 8 7 12 9 5033 1 Backplane connector 8 Fibre Channel optical host 2 Access door bus adapter 3 Optical gigabit link module 9 Maintenance port cable for a (GLM) PC connection 4 Program card slot - - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 3
perform one of the following options: ■ If the disk was not initialized with the SAVE_CONFIGURATION switch, locate existing information that will support the manual configuration of the subsystem, and then proceed to step 6. ■ If the disk was initialized with the SAVE_CONFIGURATION switch, enter the - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 4
Troubleshooting" appendix of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. manually restore the current device configuration using existing information and the appropriate array controller user guide or CLI reference guide - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 5
13. Determine whether the configuration restore process completed successfully, and then perform one of the following options: ■ Perform the following substeps if the configuration restore process did not complete successfully. a. Reset the PC or terminal baud rate to match the original - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 6
Note: In Transparent Failover mode, units that failed over due to a RESTART command will revert back to preferred controller after about 1 minute. e. Exit VTDPY by pressing Ctrl+Y. 3. f. Disable Failover mode, and take the controllers out of the dual-redundant configuration by entering the - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 7
cache modules have been removed. (Refer to instructions for installing a cache module in a dual-redundant controller configuration of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for more information.) Otherwise, continue to - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 8
refer to Table 14 through Table 16 in the "Controller and Cache Replacement Troubleshooting" appendix of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide and take corrective actions. d. Disconnect the PC or terminal from the maintenance - HP StorageWorks EMA16000 | HP StorageWorks Replacing an HSG60 or HSG80 Array Con - Page 9
to Table 14 through Table 16 in the "Controller and Cache Replacement Troubleshooting" appendix of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. Note: The replacement controller can fail with a recursive bugcheck (halting with OCP
HP StorageWorks
Replacing an HSG60 or
HSG80 Array Controller
Replacing an HSG60 or HSG80 Array Controller Installation
Instructions
Sixth Edition (March 2005)
Part Number: EK-80CTL-IM. F01
©
Copyright 2000–2005 Hewlett-Packard Development Company, L.P.
Hewlett-Packard Company makes no warranty of any kind with regard to
this material, including, but not limited to, the implied warranties of
merchantability and fitness for a particular purpose. Hewlett-Packard shall
not be liable for errors contained herein or for incidental or consequential
damages in connection with the furnishing, performance, or use of this
material.
This document contains proprietary information, which is protected by
copyright. No part of this document may be photocopied, reproduced,
or translated into another language without the prior written consent of
Hewlett-Packard. The information contained in this document is subject to
change without notice.
Microsoft®, MS Windows®, Windows®, and Windows NT® are U.S.
registered trademarks of Microsoft Corporation.
Product names mentioned herein may be trademarks of their respective
companies as reflected by an associated footnote.
Hewlett-Packard Company shall not be liable for technical or editorial
errors or omissions contained herein. The information is provided “as is”
without warranty of any kind and is subject to change without notice. The
warranties for Hewlett-Packard Company products are set forth in the
express limited warranty statements for such products. Nothing herein
should be construed as constituting an additional warranty.
Installation
Instructions
Read instructions completely before
beginning the installation procedure
About these instructions
This document contains instructions for replacing an
HP StorageWorks HSG60 or HSG80 array controller. Array
controller replacement procedures in these instructions
include:
■
Replacing HSG60 and HSG80 controllers in
single-controller configurations
, page 3
■
Replacing HSG60 and HSG80 controllers in
dual-redundant controller configurations
, page 5
Prerequisites and special considerations
Observe the following prerequisites and special considerations
before
replacing an HSG60 or HSG80 array controller:
■
Single-to-Dual-redundant configuration upgrades
—For
instructions on upgrading a single-controller configuration
to a dual-redundant controller configuration, refer to the
appropriate documentation that shipped with your array
controller or subsystem component.
■
DRM Configurations
—If you are using HP StorageWorks
Data Replication Manager (DRM) with HSG60 or HSG80
controllers that need to be replaced, refer to the
HP
StorageWorks HSG60 and HSG80 Array Controller and
Array Controller Software Maintenance and Service Guide
for specific instructions. A copy of this guide can be
downloaded from the HP website at:
h
ttp://h18006.www1.hp.com/products/storageworks/
acs/index.html
.
■
Hardware Compatibility
—The replacement controller
hardware must be compatible with the remaining controller
hardware. Refer to product-specific release notes and
documentation for information regarding hardware
compatibility.
■
Software Compatibility
—The software versions and
patch levels of the replacement controller must be the same
as that of existing subsystem controllers.
General information
Figure 1
,
Figure 2
, and
Figure 3
(on page 2
)
provide general
information about the HSG60 and HSG80 array controllers and
specific host cable connections for each array controller type.
Tip:
See the applicable array controller figure (
Figure 1
,
Figure 2
,
or
Figure 3
on page 2) for clarification during the selected
procedures.
Note:
The maintenance port cable shipped with the array controller
has a 9-pin connector for a PC connection only. If you are using a
terminal instead of a PC, obtain the optional maintenance port
cable.