Installation and Configuration Guide HP StorageWorks HSG80 ACS Solution Software V8.8 for HP-UX Product Version: 8.8-1 First Edition (March 2005) Part Number: AA-RV1FA-TE This guide provides installation and configuration instructions and reference material for operation of the HSG80 ACS Solution - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 2
The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting V8.8 for HP-UX Installation and Configuration Guide First Edition (March 2005) Part Number: AA-RV1FA-TE - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 3
contents Contents About this Guide 13 Overview 14 Intended Audience 14 Related Documentation 14 Chapter Content Summary 16 Conventions 18 Document Conventions 18 Symbols in Text 18 Symbols on Equipment 19 Rack Stability 21 Getting Help 22 HP Technical Support 22 HP Storage Web Site 22 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 4
83 Mirrorset Planning Considerations 84 Keep these points in mind when planning mirrorsets 85 4 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 5
HP Host Mode 115 Solution Software Upgrade Procedures 120 Preparing Storage RAID Array 121 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 5 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 6
Using CLI 154 Verifying the Node ID and Check for Any Previous Connections 154 6 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 7
178 Enabling Autospare 178 Deleting a Storageset 179 Changing Switches for a Storageset or Device 179 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 7 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 8
Integration Patch 229 Integrating Controller's SWCC Storage Window with CIM 230 "Insight Manager Unable to Find Controller's Storage Window 231 Troubleshooting Client Installation 232 Invalid Network Port Assignments During Installation 232 "There is no disk in the drive" Message 233 8 HSG80 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 9
and its Host to Navigation Tree 234 Removing Command Console Client 236 Where to Find Additional Information 238 About the User Guide 238 About the Online Help 238 Glossary 239 Index 261 Figures 1 General configuration flowchart (panel 1 25 2 General configuration flowchart (panel 2 26 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 10
102 12 SWCC features and components 127 13 Installation and configuration overview 129 10 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 11
Contents HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 11 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 12
Contents 12 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 13
■ Plan the storage array subsystem. ■ Install and configure the storage array subsystem on individual operating system platforms. "About this Guide" topics include: ■ "Overview", page 14 ■ "Chapter Content Summary", page 16 ■ "Conventions", page 18 ■ "Rack Stability", page 21 ■ "Getting Help", page - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 14
StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide, EK-G80MS-SA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide, EK-G80TS-SA. C01 ■ SWCC v2.5 documentation (Client software delivered in - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 15
About this Guide Solution software host support includes the following platforms: - IBM AIX - HP-UX - Linux (Red Hat x86, SuSE x86) - Novell NetWare - Open VMS - Sun Solaris - Tru64 UNIX - Windows NT/2000/Windows Server 2003 (32-bit) Additional support required by HSG80 ACS Solution Software V8.8-1, - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 16
About this Guide Chapter Content Summary Table 1 below summarizes the content of the chapters. Table 1: Summary of chapter contents Chapters 1. Planning a Subsystem using the Command Line Interpreter (CLI). 16 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 17
of common procedures that are not mentioned elsewhere in this guide. ■ Backing Up Subsystem Configuration ■ Cloning Data for Install the Client ■ Installing the Client ■ Installing the Integration Patch ■ Troubleshooting Client Installation ■ Adding Storage Subsystem and its Host to the Navigation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 18
(output and messages) Command-line and code variables Web site addresses Symbols in Text The following symbols may be found in the text of this guide. They have the following meanings: WARNING: Text set off in this manner indicates that failure to follow directions in the warning could result in - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 19
following equipment symbols may be found on hardware for which this guide pertains. They have the following meanings: Any enclosed surface or the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 20
About this Guide Power supplies or systems marked with these symbols indicate the presence of to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. 20 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 21
About this Guide Rack Stability Rack stability protects personnel and equipment. WARNING: To reduce the risk of personal injury or damage to the equipment, be more than one rack component is extended for any reason. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 21 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 22
still have a question after reading this guide, contact an HP authorized service provider or access our web site http://www.hp.com. HP Technical Support Telephone numbers for worldwide technical support are listed on the following HP web site http://www.hp.com/support/. From this web site, select - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 23
About this Guide HP Authorized Reseller For the name of your nearest HP authorized reseller: ■ In the United States, call 1-800-345-1518 ■ In Canada, web site for locations and telephone numbers http://www.hp.com. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 23 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 24
on the following pages. Refer to these charts while installing and configuring a new storage subsystem. All references in the flowcharts pertain to pages in this guide, unless otherwise indicated. 24 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 25
About this Guide Unpack subsystem See the unpacking instructions on shipping box Plan a subsystem Chapter 1 Plan storage configurations Chapter 2 Prepare host system 1: General configuration flowchart (panel 1) HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 25 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 26
About this Guide A Configure devices page 168 Continue creating units until you have you have completed your planned configuration. Create storagesets and 181 Figure 2: General configuration flowchart (panel 2) 26 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 27
About this Guide B Install Agent Chapter 4 Install Client Appendix B Create storage See SWCC online help Verify storage setup page 181 Figure 3: Configuring storage with SWCC flowchart (panel 3) HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 27 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 28
About this Guide 28 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 29
delete the 8 MB EISA partition. Refer to HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for details. Refer to Chapter 2 when planning the types of storage containers you need. Storage containers are individual disk drives (JBOD - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 30
module CXO7365A B Figure 4: Location of controllers and cache modules in a Model 2200 enclosure 30 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 31
"other controller" in a Model 2200 enclosure. Figure 7 shows the same relationship in a BA370 enclosure. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 31 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 32
2 This controller CXO6468D Figure 7: "This controller" and "other controller" for the BA370 enclosure 32 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 33
of failover can work with loop or fabric topology. Note: Multiple-bus failover mode is only supported when Secure Path is used. Refer to the Secure Path documentation for more information on using multiple link. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 33 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 34
for failures of either the Fibre Channel link or host Fibre Channel adapters. 34 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 35
D120 Host port 1 standby Controller B Host port 2 active Figure 8: Transparent failover-normal operation CXO7036A HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 35 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 36
ports ■ Each host has two or more paths to the units All hosts must have operating system software that supports multiple-bus failover mode. With this software, the host sees the same units visible through two (or more HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 37
-bus failover mode, you can specify which units are normally serviced by a specific controller of a controller pair. Units can be between the controllers ■ All hosts must have operating system software that supports multiple-bus failover mode HSG80 ACS Solution Software V8.8 for HP-UX Installation - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 38
2 active NOTE: FCA = Fibre Channel Adapter Figure 10: Typical multiple-bus configuration CXO7094B 38 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 39
Planning a Subsystem Selecting a Cache Mode The cache module supports read, read-ahead, write-through, and write-back caching techniques. The cache technique is selected or an uninterruptible power supply). HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 39 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 40
is stored in-the cache memory on its way to the disk drives. 40 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 41
: Mirrored caching Before enabling mirrored caching, make sure the following conditions are met: ■ Both controllers support the same size cache. ■ Diagnostics indicate that both caches are good. ■ No unit errors are HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 41 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 42
an actual LUN, the SHOW UNITS command does not display the CCL location. 42 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 43
and an active host port on a controller. Note: In ACS V8.8-1, the maximum number of supported connections is 96. Naming Connections It is highly recommended that you assign names to connections that have characters. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 43 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 44
-bus failover mode, each adapter has two connections, as shown in Figure 14. 44 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 45
= Fibre Channel Adapter CXO7081B Figure 12: Connections in separate-link, transparent failover mode configurations HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 45 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 46
Channel Adapter CXO7079B Figure 13: Connections in single-link, transparent failover mode configurations 46 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 47
NOTE: FCA = Fibre Channel Adapter Figure 14: Connections in multiple-bus failover mode CXO7080B HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 47 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 48
1 have a default offset of 0 and connections on port 2 have a default offset of 100. 48 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 49
the unit's range (unit number of 127 minus offset of 128 is a negative number). HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 49 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 50
Start Unit command to move the unit from one controller to the other. 50 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 51
assigned at connection offsets (so that every host connection has a unit presented at LUN 0). HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 51 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 52
offsets What the connection sees LUN 0 as Unit whose number matches offset CCL 52 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 53
the access path of selected host connections on a shared loop or fabric ■ Setting offsets HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 53 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 54
the following section "Restricting Host Access by Disabling Access Paths" on page 55. 54 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 55
for each unit. Default access enables the unit to be accessible to all hosts. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 55 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 56
the potential data/security breach that occurs when a new host connection is added. 56 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 57
and the host must be enabled in order for multiple-bus failover to work. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 57 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 58
the connections to host BLUE. At least two connections must be enabled for 58 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 59
host connections to the same host computer must be set to the same offset. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 59 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 60
-EE01 ■ Controller A and controller B, port 2-worldwide name + 2, for example 5000-1FE1-FF0C-EE02 60 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 61
) 2 Checksum Figure 18: Placement of the worldwide name label on the Model 2200 enclosure HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 61 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 62
the unit is reinitialized. Use the SHOW command to list the LUN ID. 62 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 63
page 93 ■ "Specifying Initialization Switches", page 95 ■ "Specifying Unit Switches", page 99 ■ "Creating Storage Maps", page 100 Refer to Chapter 3 for instructions on how to prepare your host computer to accommodate the HSG80 controller storage subsystem. HSG80 ACS Solution Software V8.8 for HP - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 64
one of the following methods: - Use SWCC. See the SWCC documentation for details. 64 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 65
you flexibility in defining and naming your storage containers. See the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 66
-critical data? Is availability the highest priority or would standard backup procedures suffice? 66 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 67
physical devices per RAID 0 storageset (stripeset) ■ 48 physical devices per RAID 0+1 storageset (striped mirrorset) ■ 146 GB disks (for universal drives only) are the largest supported for the HSG60 and HSG80 storage array. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 68
new container before proceeding with subsystem activities to avoid operational and performance issues. 68 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 69
-redundant controller configuration are 0-3 and 8-15, respectively. (This applies to the BA370 cabinet only.) HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 69 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 70
set through the PVA module. Enclosure ID number 1, which assigns devices to targets 4 through 7, is not supported. Figure 22 shows how data is laid out on disks in an extended configuration. Operating system view Virtual disk Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 71
above the controller enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 71 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 72
Disk61000 Disk61100 Disk61200 Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 72 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 73
Disk20800 Disk21000 Disk21100 Disk21200 Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 73 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 74
ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 74 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 75
Disk10000 Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk10900 Disk11000 Disk11100 Disk11200 Disk11300 Disk11400 Disk11500 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 75 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 76
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 76 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 77
Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 77 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 78
Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 23: Storage container types CXO667 78 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 79
a comprehensive discussion of RAID, refer to The RAIDBOOK-A Source Book for Disk Array Technology. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 79 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 80
) Read Source ___Least busy (default) ___Best fit ___Fast ___Round robin ___None ___Disk drive: 80 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 81
hosts enabled Read caching_______X__ Read-ahead caching_____ Write-back caching___X__ Write-through caching____ _ALL HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 81 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 82
Disk 10100 Chunk 1 4 25 Figure 24: Three-member RAID 0 stripeset (example 1) 36 CXO7287A 82 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 83
and high availability, consider using a RAIDset, striped-mirrorset, or a host-based shadow of a stripeset. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 83 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 84
for storing data that can be reproduced easily or whose loss does not prevent the system from supporting its critical mission. ■ Evenly distribute the members across the device ports to balance the load mirrorset. 84 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 85
availability is your top priority, consider using dual-redundant controllers and redundant power supplies. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 85 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 86
data availability. Figure 28 shows an example of a RAIDset that uses five members. 86 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 87
systems from working with large RAIDsets. ■ Both cache modules must be the same size. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 87 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 88
data availability. Figure 30 shows a second example of a striped mirrorset using six members. 88 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 89
mirrorset (example 2) Disk 5 Block 2 Block 5 Block 8 Disk 6 Block 2 Block 5 Block 8 Virtual disk #3 Mirrorset CXO6462A HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 89 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 90
and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide describes the CLI command, ADD CONCATSETS, which is used to Use the ADD CONCATSETS command only with host operating systems that support dynamic volume expansion. Use of this command could result in inacessible - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 91
are separately addressable storage units; therefore, you can partition a single storageset to service more than one user group or application. Defining a Partition Partitions are expressed as details about cloning.) HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 91 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 92
to enable each switch if you use CLI commands to configure the storageset or device manually. The HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide contains the details of the CLI commands and their switches. Changing Switches You can change - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 93
and SET RAIDset-name commands in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. Mirrorset Switches Use the following switches to control how a mirrorset behaves to ensure data availability: ■ Replacement policy ■ Copy speed ■ Read - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 94
the use of these switches, refer to CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. 94 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 95
request size determines whether striping increases the request rate or the data-transfer rate. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 95 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 96
not know, use a chunk size of 15 times the average transfer request rate. 96 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 97
command shows which disks are used to backup configuration information. Note: DO NOT use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 98
of a mirrorset. See the REDUCED command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide for information on removing disk drives from a mirrorset. NODESTROY is ignored for members of a RAIDset. Geometry The geometry parameters of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 99
under the SET unit-number command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Command Line Interface Reference Guide. One unit switch, ENABLE/DISABLE_ACCESS_PATH, determines which host connections can access the unit, and it is described in the larger topic of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 100
R1. 3. Enter the following command to turn off the flashing LEDs: LOCATE CANCEL 100 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 101
named M7. M7 consists of Disk11200 and Disk21200. ■ Disk31200 and Disk41200 are spareset members. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 101 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 102
M5 DISK ID Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk21000 Disk21100 Disk21200 102 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 103
M6 10 12 spare Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 103 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 104
Planning Storage Configurations 104 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 105
"Installing RAID Array Storage System", page 106 ■ "Making a Physical Connection", page 110 ■ "Configuring HP-UX File System", page 115 Refer to Chapter 4 for instructions on how to install and configure the HSG Agent. The Agent for HSG is operating system-specific and polls the storage. HSG80 ACS - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 106
use the disk enclosure handles to lift the enclosure. The handles cannot support the weight of the enclosure. Only use these handles to position the enclosure SCSI Controller Enclosures User Guide and the HP StorageWorks Model 4300 Family Ultra3 LVD Disk Enclosures User Guide for further information. - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 107
unused bays. Fibre Channel cabling information is shown to illustrate supported configurations. In a dual-bus disk enclosure configuration, disk enclosures dual-bus system and Figure 34 for a single-bus system. Note that the supported cable lengths are 1, 2, 3, 5, and 10 meters. 7. Connect the AC - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 108
Channel Ports Figure 33: Dual-bus enterprise storage RAID array storage system CXO7383A 108 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 109
6 Cable 8 Fibre Channel Ports Figure 34: Single-bus enterprise storage RAID array storage system HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 109 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 110
by HP/QLogic can be used with the storage subsystem and your HP platform. The supported HP HBAs are: ■ A5158A, 32/64-bit, 1 Gbps FC PCI; ■ Gbps FC PCI; Install the HBA in your HP system using the instructions provided in the HBA documentation before preparing the system to interface with the Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 111
The computer hardware manual ■ Appropriate tools to service your computer The host bus adapter board plugs into a standard PCI slot in the host computer. Refer to the system manual for instructions on installing PCI ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 111 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 112
Host System For native HP HBAs, follow the instructions that came with your adapter. Connecting to Your Host following steps: a. Login to the switch. For more information, refer to the QuickLoop Management Guide that was shipped with your switch. b. At the switchx:admin> prompt, enter the following - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 113
a later time, device special files can be created without Reboot, either manually or automatically, by using the insf -e command: After rebooting the new ServiceGuard V11.xx on HP-UX, a multihost configuration is supported on HP systems. The HP StorageWorks Command Console (SWCC Guide 113 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 114
2 SHR-1541 Figure 35: Single switch HP MC/ServiceGuard cluster, high availability configuration 114 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 115
to the HP StorageWorks Command Console V2.5 User Guide). LUNs created on the Array must be assigned Refer to the HP System Administration Tasks Manual for instructions on the following tasks: - Adding create a volume group. The solution around this problem is to use HP-UX commands to create/extend - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 116
following command to make the directory vg01: # mkdir /dev/vg01 Note: The standard HP-UX kernel supports vg00 to vg09. Creation of volume groups greater than vg09 requires kernel tuning. Refer to the appropriate 8 116 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 117
/dsk/cntndn 6. If necessary, extend the volume group: # vgextend /dev/vg0n /dev/dsk/cntndn HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 117 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 118
volumes --- PV Name /dev/dsk/c5t0 d1 PV Status available Total PE 8677 118 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 119
available/syn cd Mirror copies 0 Consistency Recovery MWC Schedule parallel LV Size (Mbytes) 100 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 119 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 120
purpose of performing upgrades to the ACS firmware, this Solution Software Kit supports previous ACS V8.6 and 8.7. It is recommended that you do not HSG80 Array Controller and Array Controller Software Maintenance and Service Guide and the Solution Software Release Notes for the latest information - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 121
Preparing the Host System Note: Rolling upgrades are not supported on HP-UX when configured with Secure Path. Preparing Storage RAID Array Prepare the Enterprise/Modular Storage RAID must be done on all nodes. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 121 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 122
all nodes. Rolling Upgrades Most major problems that occur when performing a rolling Software Maintenance and Service Guide. An upgrade performed After upgrading the second controller, a manual restart is required. ■ In some cases not supported on HP-UX when configured with Secure Path - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 123
at boot options to the off state. For MC/ServiceGuard clusters, set option 4 to the off state on all nodes. Rolling Upgrades Most major problems that occur when performing a rolling upgrade are due to the changes to the array controller NVRAM configuration. Therefore, it is important to follow the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 124
and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. An upgrade performed while the subsystem is up and running after each controller has been upgraded. ■ After upgrading the second controller, a manual restart is required. ■ In some cases a vgchange -a y must be - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 125
Chapter 5 for a description of how to configure a subsystem that uses Fibre Channel fabric topology. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 125 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 126
SWCC for Versions 11i V2.0 and 11i V2.0 Update 2. ACS V8.8-1 also does not support root, boot, dump, or swap. Note: For installations using SWCC, see "Why Use StorageWorks Command Console (SWCC)?" on page 127. 126 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 127
pager notification and lets you manage your virtual disks. The Client runs on Windows 2000 with Service Pack 4, Windows NT 4.0 with Service Pack 6A or above, and Windows Server 2003 (32-bit). ■ The Agent obtains the ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 127 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 128
Installing and Configuring HSG Agent Note: For serial and SCSI connections, the Agent is not required for creating virtual disks. 128 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 129
your hardware has been set up correctly. See the previous chapters in this guide. Verify that you have a network connection for the Client and Agent systems Agent. Install the Client software on Windows 2000 with Service Pack 4 or Windows NT 4.0 with Service Pack 6A, and Windows Server 2003 (32-bit). - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 130
on the LAN. If you have a WAN or a connection to the Internet, monitor the subsystem with TCP/IP. Note: SWCC does not support the dynamic host configuration protocol (DHCP) or the Windows Internet Name Service (WINS). 130 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 131
example of a network connection 5 Hub or switch 6 HSG80 controller and its device subsystem 7 Servers HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 131 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 132
to run on HP-UX V11.00 and V11.11 in 32or 64-bit mode operation. Note: SWCC is not supported on HP-UX Versions 11i V2.0 or 11i V2.0 Update 2. The memory requirements are based on estimations that have the product. 132 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 133
It is recommended that you have at least 250 mb of available space in your /var directory initially to support the SWCC Agent event logging system. You can clean the log by using an editor such as vi or ", page 138. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 133 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 134
Installing and Configuring HSG Agent The SWCC Agent installation now supports a graphic environment installation. You must have an X-windows environment setup in order to run this type . Figure 36: GUI Installation 134 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 135
Installing and Configuring HSG Agent Figure 37: Agent "data entry window" HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 135 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 136
Agent notification scheme for the Client. (You must select one.) ■ No error notification 136 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 137
or part of the installation has failed. Below is a sample of the default screen. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 137 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 138
Agent notification scheme for the Client. (You must select one.) - No error notification 138 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 139
: Would you like to add another client? [y,N] Configure CCL 3. Select option N and press Enter. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 139 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 140
select the hardware path from the list. You should not include the CCLs for the RA3000 because they are not supported by this Agent. Note that the disc3 driver indicates that this CCL is on an HP-PB bus. The : 140 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 141
Agent running for it to monitor your subsystems and provide updates to remote computers. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 141 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 142
in Figure 39 above, is displayed. 16. To exit, select Q and press Enter. 142 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 143
identifier for use with its MIB. 5. Enter Compaq Computer Corporation as the Agent manufacturer. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 143 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 144
your subsystems and for it to provide status updates to your Client systems. 144 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 145
must stop and restart the HS-Series Agent for your changes to take effect. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 145 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 146
the Agent. Repeat the menu selection and select option Y to start the Agent. 146 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 147
Array Configuration menu; however, the Agent must be running in order to monitor subsystems. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 147 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 148
command: # /installation_directory/steam/bin/config.sh Note: For HP-UX, only one alternate path is supported in transparent failover mode. 2. Select option 15 to modify a subsystem. 3. Enter the position prompts. 148 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 149
2>&1 ntfy::respawn:/opt/steam/bin/notify.exe >> /var/adm/syslog/steamd.log 2>&1 /etc/services spgui 4998/tcp #StorageWorks Client spagent 4999/tcp #StorageWorks Agent Remove the steam directory and all .exe HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 149 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 150
Installing and Configuring HSG Agent At this point the only way to clear this without rebooting is to kill the process and repeat step 3. For example: kill -9 1498 kill -9 1497 cd /opt rm -r /opt/steam 150 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 151
. To install a controller or cache module and the PCMCIA card, see the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 152
maintenance port cables when not communicating with the controller through the local connection. 152 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 153
switch as part of the configuration procedure ("Configuring a Single Controller Using CLI", page 154). HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 153 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 154
(Node IDs and Port IDs)", page 60, for the location of the sticker. 154 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 155
connection opens. Configuring Controller Settings 5. Set the SCSI version using the following command syntax: HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 155 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 156
ALLOCATION_CLASS=N Restarting the Controller 9. Restart the controller, using the following command: RESTART THIS 156 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 157
THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for the format of optional settings. 4. Verify that all commands have taken effect. Use the following command: SHOW THIS Verify node - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 158
seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 158 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 159
to communicate with the Fibre Channel switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable and Verifying Connections 6. Plug the ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 159 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 160
as part of the configuration procedure ("Configuring a Controller Pair Using CLI", page 161). 160 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 161
Names (Node IDs and Port IDs)", page 60, for the location of the sticker. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 161 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 162
to SCSI-3 does not make the controller fully compliant with the SCSI-3 standards. 162 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 163
up the battery discharge timer. Enter the following command to start FRUTIL: RUN FRUTIL HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 163 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 164
THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for the format of optional settings. Perform this step on both controllers. 13. Verify that all commands have taken effect by entering - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 165
(10 seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 165 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 166
want to communicate with the FC switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable and Verifying Connections 16. Plug the . 166 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 167
FC Configuration Procedures Verifying Installation To verify installation for your HP-UX host, enter the following command: SHOW DEVICES HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 167 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 168
Configuration Procedures Configuring Devices The disks on the device bus of the HSG80 can be configured manually or with the CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following system. 168 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 169
(R0) Storagesets Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 43: Storage container types HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 169 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 170
the ADD MIRRORSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the mirrorset switches. 2. Initialize the mirrorset, specifying any desired switches: INITIALIZE MIRRORSET-NAME SWITCHES See - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 171
ADD RAIDSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the RAIDset switches. 2. Initialize the RAIDset, specifying any desired switches: INITIALIZE RAIDSET-NAME SWITCH Note: HP recommends - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 172
MIRR3 DISK10200 DISK20200 ADD STRIPESET STRIPE1 MIRR1 MIRR2 MIRR3 INITIALIZE STRIPE1 SHOW STRIPE1 172 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 173
Note: See the CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for a description of the partition switches. 3. Verify the partitions: SHOW STORAGESET-NAME HSG80 ACS Solution Software V8.8 for HP-UX - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 174
DISK30000 INITIALIZE RAID1 CREATE_PARTITION RAID1 SIZE=25 CREATE_PARTITION RAID1 SIZE=LARGEST SHOW RAID1 174 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 175
under the ADD UNIT command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide. Because of different SCSI versions, refer to the section "Assigning Unit Numbers Depending on SCSI_VERSION", page 51. The choice for SCSI_VERSION - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 176
. The RESTART this_controller command must be entered immediately after the RESTART other_controller command. 176 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 177
to the controller should it need to replace a failed member of a RAIDset or mirrorset. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 177 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 178
disk drive is automatically initialized and placed into the spareset. If initialization fails, the disk drive remains in the failedset until you manually delete it from the failedset. To enable autospare, use the following command: SET FAILEDSET AUTOSPARE 178 HSG80 ACS Solution Software V8.8 for - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 179
are associated with it. Remember to update the storageset profile when changing its switches. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 179 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 180
example, the following command enables write protection for unit D100: SET D100 WRITE_PROTECT 180 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 181
For more details on using the CLI, refer to the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide. For more details on using SWCC, see the HP StorageWorks Command Console V2.5 User - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 182
FC Configuration Procedures 182 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 183
in Chapter 2. Templates to help you build your storage map are supplied in Appendix A. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 183 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 184
is. For example, if the disk number is disk10200, 2 is the target number. 184 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 185
units that are logical or virtual disks comprised of storagesets configured from physical disks. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 185 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 186
that is displayed by the CLI interpreter. Note: "This" controller is top controller (A). 186 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 187
. RUN FRUTIL Do you intend to replace this controller's cache battery? Y/N [Y] Y SET THIS MIRRORED_CACHE HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 187 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 188
the Fibre Channel cable from the second adapter in host "RED." SHOW CONNECTIONS 188 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 189
RED2B2 SET RED2B2 OPERATING_SYSTEM=HP RENAME !NEWCON02 RED2A2 SET RED2A2 OPERATING_SYSTEM=HP SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 189 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 190
two hosts. The resulting connection table should be displayed similar to the following: 190 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 191
-XX ADAPTER_ID=XXXX-XXXX-XXX XX X-XXXX BLUE2B2 HP THIS 2 XXXX OL this 0 XX HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 191 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 192
this 0 XX HOST_ID=XXXX-XXXX-XXXX-XX ADAPTER_ID=XXXX-XXXX-XXX XX X-XXXX 192 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 193
D101 DISK50300 DISABLE_ACCESS_PATH=ALL SET D101 ENABLE_ACCESS_PATH=(BLUE1A1, BLUE1B1, BLUE2A2, BLUE2B2) ADD SPARESET DISK60300 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 193 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 194
Using CLI for Configuration SHOW UNITS FULL 194 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 195
Backing Up, Cloning, and Moving Data This chapter includes the following topics: ■ "Backing Up Subsystem Configurations", page 196 ■ "Creating Clones for Backup", page 197 ■ "Moving Storagesets", page 201 7 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 195 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 196
is backed up. Note: DO NOT use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. The SHOW DEVICES FULL command shows which disk drives are HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 197
complete, you can back up the Clones rather than the storageset or single-disk unit, which can continue to service its I/O load. When you are cloning a mirrorset, Clone does not need to create a temporary mirrorset. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 197 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 198
you want to use for the Clone units. 7. Back up the Clone unit. 198 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 199
=2 SET C_MB REPLACE=DISK20300 COPY IN PROGRESS FOR EACH NEW MEMBER. PLEASE BE PATIENT... . HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 199 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 200
C_ST1 D99 HAS BEEN CREATED. IT IS A CLONE OF D98. CLONE - NORMAL TERMINATION 200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 201
the release notes for the version of your controller software for information on which drives can be supported. Caution: Never initialize any container or this procedure does not protect data in the storageset. NAME HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 201 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 202
cabinet DELETE D100 DELETE RAID99 DELETE DISK10000 DELETE DISK10100 DELETE DISK20000 DELETE DISK20100 202 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 203
Backing Up, Cloning, and Moving Data New cabinet ADD DISK DISK10000 ADD DISK DISK10100 ADD DISK DISK20000 ADD DISK DISK20100 ADD RAIDSET RAID99 DISK10000 DISK10100 DISK20000 DISK20100 ADD UNIT D100 RAID99 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 203 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 204
Backing Up, Cloning, and Moving Data 204 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 205
Enclosure", page 220 ■ "Storage Map Template 9 for the Model 4354R Disk Enclosure", page 223 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 205 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 206
) ___ 64 blocks ___Yes ___Retain ___ 128 blocks ___ 256 blocks ___ Other: 206 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 207
Subsystem Profile Templates Unit Switches: Caching Access by following hosts enabled Read caching__________ Read-ahead caching_____ Write-back caching______ Write-through caching____ HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 207 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 208
D50100 D60100 Power Supply Power Supply D10000 D20000 D30000 D40000 D50000 D60000 2 Targets 1 0 208 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 209
D30900 D40900 D50900 D60900 Power Supply Power Supply 8 D10800 D20800 D30800 D40800 D50800 D60800 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 209 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 210
D51300 D61300 Power Supply Power Supply 12 D11200 D21200 D31200 D41200 D51200 D61200 210 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 211
Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 211 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 212
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 212 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 213
Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 DISK ID continued on the following page HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 213 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 214
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 214 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 215
12 ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 215 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 216
ID DISK ID Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk21000 Disk21100 Disk21200 216 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 217
12 ID DISK ID Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 217 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 218
ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk51000 Disk51100 Disk51200 218 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 219
12 ID DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 219 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 220
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk50900 Disk51000 Disk51100 Disk51200 Disk51300 Disk51500 Disk51500 220 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 221
Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 DISK ID HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 221 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 222
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 222 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 223
Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 223 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 224
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 224 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 225
page 226 ■ "Before You Install the Client", page 227 ■ "Installing the Client", page 228 ■ "Installing the Integration Patch", page 229 ■ "Troubleshooting Client Installation", page 232 ■ "Adding Storage Subsystem and its Host to Navigation Tree", page 234 ■ "Removing Command Console Client", page - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 226
an individual device (JBOD) ■ Monitor many subsystems at once ■ Set up pager notification 226 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 227
the software product description that came with the software for a list of supported hardware. 3. Verify that you have the SNMP service installed on the computer. SNMP must be installed on the computer for this 4. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 227 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 228
problem is not seen under Windows NT 4.0 Server. 2. Insert the CD-ROM into a computer running Windows 2000 with Service Pack 4, Windows NT 4.0 (Intel) with Service the instructions on the screen. After you install the software, the Asynchronous Event Service (AES) starts. AES is a service that - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 229
remove the HSG80 Client, you no longer are able to access its Storage Window. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 229 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 230
given the status of the system. 9. Click Launch. The controller's Storage Window opens. 230 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 231
: 1. Double-click the Insight Agents icon (Start > Settings > Control Panel). A window is displayed showing you the active and inactive Agents under the Services tab. 2. Highlight the entry for Fibre Array Information and click Add. The Fibre Array Information entry is moved from Inactive Agents to - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 232
Troubleshooting Client Installation This section provides information on how to resolve some of the problems services (services file or for UCX, the local services database). If the SWCC installation finds an entry in the local services the network and added manually to the services file. There are - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 233
the floppy drive and a CD-ROM in the CD-ROM drive. Then, click Retry. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 233 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 234
the host name or its TCP/IP address and click Apply. 5. Click Close. 234 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 235
-click the Storage Window icon. Figure 50: Navigation window showing expanded "Atlanta" host icon HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 235 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 236
to HP StorageWorks Command Console V2.5 User Guide. Removing Command Console Client Before you . This prevents the system from reporting that a service failed to start every time the system is restarted /Remove. 6. Follow the instructions on the screen. 236 HSG80 ACS Solution Software V8.8 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 237
Installing, Configuring, and Removing the Client Note: This procedure removes only the Command Console Client (SWCC Navigation Window). You can remove the HSG80 Client by using the Add/Remove program. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 237 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 238
on how to use SWCC. Some of the topics in the user guide are the following: ■ About AES ■ Adding Devices ■ Adding Virtual Disks ■ Setting Up Pager Notification ■ How to Integrate SWCC with Insight Manager ■ Troubleshooting Information About the Online Help Most of the information about the Client - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 239
on a removable ROM program card that provides the operating system for the array controller. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 239 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 240
address header. A method used to bring a system or device into a defined state by means of its own action. For example, a machine routine whose first few instructions are enough to bring the rest of the routine into the computer from an input device. 240 HSG80 ACS Solution Software V8.8 for HP-UX - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 241
. Stripesets and mirrorsets are examples of storageset containers the controller uses to create units. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 241 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 242
, even though the host operation processing the data has completed. Direct Memory Access. 242 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 243
. The EMU also controls certain cabinet hardware including DOC chips, alarms, and fan speeds. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 243 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 244
Fibre Channel Fabric Generic Requirements Fibre Channel Framing Protocol (HIPPI on FC) Fibre Channel Generic Services-1 Fibre Channel Generic Services-2 Fibre Channel Implementation Guide Fibre Channel Link Encapsulation (ISO 8802.2) The Fibre Channel Physical and Signaling standard. Fibre Channel - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 245
block contains unrecoverable data. An invisible unit used to transfer information in Fibre Channel. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 245 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 246
heterogeneous host support HIPPI-FC host host adapter HBA Field replaceable unit. A hardware component that can be replaced at the customer location by service personnel or qualified customer service personnel. 246 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 247
error occurs. The instance code indicates when during software processing the error was detected. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 247 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 248
terminal. A single-ended bus connected to a differential bus by a SCSI bus signal converter. 248 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 249
detection and media defect management for the disk drive. It is also used to support storageset configuration and partitioning. Nontransportable disks also contain metadata to indicate they are image of data. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 249 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 250
the mirrorset. Read requests from the host are always satisfied by normal members. 250 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 251
participate in loop activities. A port must have a valid AL_PA to be in participating mode. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 251 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 252
that contains the controllers, cache modules, external cache batteries, and the PVA module. 252 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 253
information across all of the disk drives within the storageset. See also RAID level 3. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 253 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 254
background. Data warehousing, continuous computing, and enterprise applications all require remote copy capabilities. 254 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 255
remote controller is designated as the "target". The rate at which requests are arriving at a servicing entity. Radio frequency interference. The disturbance of a signal by an unwanted radio signal or frequency . HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 255 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 256
of storing data, whether it is a physical device or a group of physical devices. 256 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 257
each event to operate in relation to a timing signal. See also asynchronous. A storage device supporting sequential access to variable sized data records. (1) A SCSI device that performs an operation requested by . HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 257 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 258
drive. A unit may also be created from a more complex container such as a RAIDset. The controller supports a maximum of eight units on each target. See also target and target ID number. Sometimes called unflushed data HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 259
the cache memory accordingly, to ensure that the cache contains the most current data. HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 259 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 260
Glossary 260 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 261
topology 175 assignment of unit numbers fabric topology partition 175 single disk 175 asynchronous event service 238 audience 14 authorized reseller, HP 23 autospare enabling fabric topology 178 Index Index availability ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 261 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 262
profiles 80 Creating Clones for Backup 197 D Destroy/Nodestroy parameters 98 device switches 262 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 263
adapter installation 111 preparation 110 host connections 43 naming 43 Host storage configuration verify 181 HP authorized reseller 23 storage web site 22 technical support 22 HP-UX file system configuration 115 HSG Agent HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 264
N network port assignments 232 node IDs 60 restoring 61 NODE_ID worldwide name 60 264 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 265
related documentation 14 removing Client 236 request rate 96 requirements host adapter installation 111 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide 265 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 266
partitions 90 RAIDsets 86 striped mirrorsets 88 stripesets 82 profile 80 profiles 205 266 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 267
in text 27 symbols on equipment 19 T technical support, HP 22 templates subsystem profile 205 terminology other controller 54 restricting host access by offsets 57 SET CONNECTIONS 48 troubleshooting invalid network port assignments 232 there is no disk in Installation and Configuration Guide 267 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 268
40 write-back caching general description 39 write-through caching general description 40 268 HSG80 ACS Solution Software V8.8 for HP-UX Installation and Configuration Guide
Installation
and
Configuration
Guide
HP StorageWorks
HSG80 ACS Solution Software
V8.8
for HP-UX
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA
–RV1FA–TE
This guide provides installation and configuration instructions and reference material for