HP StorageWorks EMA16000 HP StorageWorks HSG80 ACS Solution Software V8.8 for
HP StorageWorks EMA16000 Manual
View all HP StorageWorks EMA16000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks EMA16000 manual content summary:
- HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 1
Installation and Configuration Guide HP StorageWorks HSG80 ACS Solution Software V8.8 for Sun Solaris Product Version: 8.8-1 First Edition (March 2005) Part Number: AA-RV1RA-TE This guide provides installation and configuration instructions and reference material for operation of the HSG80 ACS - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP .8 for Sun Solaris Installation and Configuration Guide First Edition (March 2005) Part Number: AA-RV1RA-TE - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 3
About this Guide 13 Overview 14 Intended Audience 14 Related Documentation 14 Chapter Content Summary 16 Conventions 18 Document conventions 18 Symbols in Text 18 Symbols on Equipment 19 Rack Stability 20 Getting Help 21 Technical Support 21 Storage web site 21 HP Authorized Reseller - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 4
80 Keep these points in mind when planning mirrorsets 81 RAIDset Planning Considerations 81 4 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 5
111 Example 111 Creating and Tuning File Systems 113 Solution Software Upgrade Procedures 113 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 5 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 6
Contents 4 Installing and Configuring the HSG Agent 117 Why Use StorageWorks Command Console (SWCC 118 Installation and Configuration Overview 119 About the Network Connection for Adapter Connection 145 6 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 7
Channel Access/Transport Paths 161 Implementation of Loop and Fabric Bindings 162 Bindings 162 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 7 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 8
4310R Disk Enclosure 209 Storage Map Template 7 for the Model 4350R Disk Enclosure 211 8 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 9
CIM 220 Finding the Controller's Storage Window 221 Troubleshooting Client Installation 221 Invalid Network Port Assignments During Installation Console Client 225 Where to Find Additional Information 226 About the User Guide 226 About the Online Help 226 Glossary 227 Index 249 Figures 1 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 10
window showing expanded "Atlanta" host icon 224 Tables 1 Summary of Chapter Contents 16 10 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 11
Example Chunk Sizes 91 11 Model 4310 disk enclosure, example of storage map 95 12 StorageWorks Solution Software Packages 105 13 SWCC Features and Components 118 14 Installation and Configuration Overview 119 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 11 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 12
Contents 12 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 13
configure the storage array subsystem on individual operating system platforms "About this Guide" topics include: ■ Overview, page 14 ■ Chapter Content Summary, page ■ Rack Stability, page 20 ■ Getting Help, page 21 ■ HP Authorized Reseller, page 22 ■ Configuration Flowchart, page 22 This book does - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 14
Maintenance and Service Guide, EK-G80MS-SA. C01 ■ HP StorageWorks HSG60 and HSG80 Array Controller Software Troubleshooting Guide, EK-G80TS-SA. C01 ■ StorageWorks Command Console (SWCC) v2.5 documentation (client software delivered in solutions kits) ■ HP StorageWorks HP StorageWorks Command Console - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 15
this Guide ■ HP StorageWorks HSG80 ACS Solution Software Release Notes (platform-specific) ■ HP StorageWorks Enterprise/Modular Storage RAID Array Fibre Channel Arbitrated Loop Configurations for Windows, Tru64, and Sun Solaris Application Note (AA-RS1ZB-TE) - Solution software host support includes - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 16
About this Guide Chapter Content Summary Table 1 below summarizes the content of the chapters. Table the differences and configuration processes for Sun servers and adapters for loop and switch support. How-to example of configuring a storage subsystem using the Command Line Interpreter (CLI - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 17
common procedures that are not mentioned elsewhere in this guide. Backing Up Subsystem Configuration Cloning Data for Backup You Install the Client ■ Installing the Client ■ Installing Integration Patch ■ Troubleshooting the Client Installation ■ Adding Storage Subsystem and its Host to the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 18
font COMMAND NAMES are uppercase unless they are case sensitive Monospace, italic font Sans serif font (http://www.hp.com) Symbols in Text These symbols may be found in the text of this guide. They have the following meanings. WARNING: Text set off in this manner indicates that failure to follow - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 19
About this Guide Note: Text set off in this manner presents commentary, sidelights, or marked with these symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of injury from electrical shock hazards, do not open - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 20
About this Guide Any product or assembly marked with these symbols indicates that injury or damage to the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. Rack Stability WARNING: To reduce the risk of personal injury or damage to the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 21
If you still have a question after reading this guide, contact an HP authorized service provider or access our web site. Technical Support Telephone numbers for worldwide technical support are listed on the following HP web site: http://www.hp.com/support/. From this web site, select the country of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 22
About this Guide HP Authorized Reseller For the name of your nearest authorized reseller: ■ In the United States subsystem. All references in the flowcharts pertain to pages in this guide, unless otherwise indicated. 22 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 23
About this Guide Unpack subsystem See the unpacking instructions on shipping box Plan a Subsystem Chapter 1 Plan Storage Configurations Chapter 2 Prepare Host General configuration flowchart (panel 1) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 23 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 24
About this Guide A Configure devices page 146 Continue creating units until you have completed your planned configuration. Create Storagesets and Partitions: 2: General configuration flowchart (panel 2) 24 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 25
About this Guide B Install Agent Chapter 4 Install Client Appendix B Create Storage See SWCC online help Verify Storage Set Up Figure 3: SWCC storage configuration flowchart (panel 3) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 25 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 26
About this Guide 26 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 27
be run for ten minutes on all units to delete the 8 MB EISA partition. Refer to HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for details. Refer to Chapter 2 when planning the types of storage containers you need. Storage - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 28
module CXO7365A B Figure 4: Location of controllers and cache modules in a Model 2200 enclosure 28 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 29
"other controller" in a Model 2200 enclosure. Figure 7 shows the same relationship in a BA370 enclosure. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 29 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 30
2 This controller CXO6468D Figure 7: "This controller" and "other controller" for the BA370 enclosure 30 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 31
of failover can work with loop or fabric topology. Note: Multiple-bus failover mode is only supported on Sun platforms when Secure Path is used. Refer to the Secure Path documentation for more information . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 31 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 32
for failures of either the Fibre Channel link or host Fibre Channel adapters. 32 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 33
D120 Host port 1 standby Controller B Host port 2 active Figure 8: Transparent failover-normal operation CXO7036A HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 33 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 34
Each host has two or more paths to the units All hosts must have operating system support or additional software that supports multiple-bus failover mode. With this software, the host sees the same units visible through ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 35
-bus failover mode, you can specify which units are normally serviced by a specific controller of a controller pair. Units can between the controllers. ■ All hosts must have operating system software that supports multiple-bus failover mode. HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 36
2 active NOTE: FCA = Fibre Channel Adapter Figure 10: Typical multiple-bus configuration CXO7094B 36 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 37
Planning a Subsystem Selecting a Cache Mode The cache module supports read, read-ahead, write-through, and write-back caching techniques. The cache technique is selected separately for the host when the write HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 37 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 38
: Mirrored caching Before enabling mirrored caching, make sure the following conditions are met: ■ Both controllers support the same size cache. ■ Diagnostics indicate that both caches are good. ■ No unit errors are HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 39
Planning a Subsystem What is the Command Console LUN? StorageWorks Command Console (SWCC) software communicates with the HSG80 controllers through an existing storage SET THIS_CONTROLLER COMMAND_CONSOLE_LUN HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 39 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 40
and an active host port on a controller. Note: In ACS Version 8.8-1, the maximum number of supported connections is 96. Naming Connections It is highly recommended that you assign names to connections that have HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 41
loop or fabric), each adapter will have two connections, as shown in Figure 13. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 41 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 42
Channel Adapter CXO7081B Figure 12: Connections in separate-link, transparent failover mode configurations 42 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 43
= Fibre Channel Adapter CXO7079B Figure 13: Connections in single-link, transparent failover mode configurations HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 43 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 44
: FCA = Fibre Channel Adapter Figure 14: Connections in multiple-bus failover mode CXO7080B 44 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 45
) - Unit number is relative to the controller (what the controller sees the unit as) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 45 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 46
unit's range (unit number of 127 minus offset of 128 is a negative number). 46 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 47
is done through the ENABLE_ACCESS_PATH switch of the ADD UNIT (or SET unit) command. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 47 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 48
be at LUN 0. In this case, it is necessary to specify SCSI-2 mode. 48 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 49
to the first available LUN location, depending on the configuration. StorageWorks recommends to use the following conventions when assigning host connection offsets specifies that access paths to ALL hosts are enabled. HP recommends that you restrict host access and that the access Guide 49 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 50
all units. See "Restricting Host Access by Disabling Access Paths" on page 51. 50 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 51
for each unit. Default access enables the unit to be accessible to all hosts. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 51 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 52
host BROWN's access, as follows: SET D120 DISABLE_ACCESS_PATH=ALL SET D120 ENABLE_ACCESS_PATH=BROWN1B2 52 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 53
Planning a Subsystem Note: StorageWorks recommends that you provide access to only specific connections, even if there is just one connection on the link. This in order for multiple-bus failover to work. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 53 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 54
the connections to host BLUE. At least two connections must be enabled for 54 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 55
host connections to the same host computer must be set to the same offset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 55 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 56
follows: SET D120 DISABLE_ACCESS_PATH=ALL SET D120 ENABLE_ACCESS_PATH=(BLUE1A1,BLUE1B1,BLUE12A2,BLUE2B2) Note: StorageWorks recommends that you always provide access to only specific connections. This way, if 56 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 57
CXO7228A Figure 18: Placement of the worldwide name label on the Model 2200 enclosure HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 57 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 58
the unit is reinitialized. Use the SHOW command to list the LUN ID. 58 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 59
page 88 ■ Specifying Initialization Switches, page 89 ■ Specifying Unit Switches, page 93 ■ Creating Storage Maps, page 93 Refer to Chapter 3 for instructions on how to prepare your host computer to accommodate the HSG80 controller storage subsystem. HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 60
). 8. Configure the storage you have now planned using one of the following methods: 60 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 61
allows you flexibility in defining and naming your storage containers. See the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Determining Storage Requirements It is important to determine your storage requirements. Here - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 62
issues. Note: HSG60 and HSG80 array controllers do not support greater than 146 GB. This restriction is enforced by the , these device buses are shared between the two controllers. (The StorageWorks Command Console calls the device ports "channels.") The standard BA370 enclosure Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 63
is always 0. 1 02 00 LUN 00 Target 02 Port 1 Figure 21: PTL naming convention HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 63 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 64
set through the PVA module. Enclosure ID number 1, which assigns devices to targets 4 through 7, is not supported. Figure 22 shows how data is laid out on disks in an extended configuration. Operating system view Virtual Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 65
above the controller enclosure, and disk enclosures 1, 2, and 3 are stacked below the controller enclosure. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 65 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 66
you keep track of the location of devices and storagesets in your shelves. 66 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 67
Disk50800 Disk51000 Disk51100 Disk51200 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 67 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 68
Disk21000 Disk21100 Disk21200 Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 68 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 69
04 ID DISK ID Disk50000 Disk50100 Disk50200 Disk50300 Disk50400 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 69 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 70
Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk10900 Disk11000 Disk11100 Disk11200 Disk11300 Disk11400 Disk11500 70 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 71
01 02 03 04 05 08 00 01 02 03 04 05 08 ID HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 71 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 72
drives or ten, looks like one large, virtual disk drive to the host. 72 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 73
Containers Planning Storage Configurations Partition Single devices (JBOD) Stripeset (R0) Storagesets Mirrorset (R1) Striped mirrorset (R0+1) RAIDset (R3/5) Figure 23: Storage container types CXO6677A HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 73 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 74
discussion of RAID, refer to The RAIDBOOK-A Source Book for Disk Array Technology. 74 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 75
(default) ___Best fit ___Fast ___None Read Source ___Least busy (default) ___Round robin ___Disk drive: HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 75 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 76
in the storageset, thereby enabling several disk drives to participate in one I/O request. 76 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 77
of reference) that occur when frequently accessed data becomes concentrated on a single disk drive. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 77 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 78
of these disks would only have an MTBF of slightly more than 4 years. 78 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 79
for storing data that can be reproduced easily or whose loss does not prevent the system from supporting its critical mission. ■ Evenly distribute the members across the device ports to balance the load ports. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 79 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 80
1 Block 2 etc. Mirrorset Figure 27: Mirrorset (example 2) Disk 2 Block 0 Block 1 Block 2 etc. CXO4594B 80 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 81
ensure data availability. Figure 28 shows an example of a RAIDset that uses five members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 81 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 82
from working with large RAIDsets. ■ Both cache modules must be the same size. 82 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 83
high data availability. Figure 30 shows a second example of a striped mirrorset using six members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 83 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 84
(example 2) Disk 5 Block 2 Block 5 Block 8 Disk 6 Block 2 Block 5 Block 8 Virtual disk #3 Mirrorset CXO6462A 84 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 85
. The HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide describes the CLI command, ADD CONCATSETS, which is used to perform concatenation. Caution: Use the ADD CONCATSETS command only with host operating systems that support - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 86
are separately addressable storage units; therefore, you can partition a single storageset to service more than one user group or application. Defining a Partition Partitions are expressed as about cloning.) 86 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 87
SWCC. If you use CLI commands to configure the storageset or device manually, the configuration procedure found in Chapter 5 of this guide will show you when and how to enable each switch. The HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 88
of these switches, refer to SET RAIDSET and SET RAIDset-name commands in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Mirrorset Switches Use the following switches to control how a mirrorset behaves to ensure data - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 89
the use of these switches, refer to CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Specifying Initialization Switches Initialization switches set characteristics for established storagesets - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 90
chunk size increases request rate Large chunk sizes also tend to increase the performance of random reads and writes. HP recommends that you use a chunk size of 10 to 20 times the average request size, rounded to the ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 91
. The SHOW DEVICES FULL command shows which disks are used to backup configuration information. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 91 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 92
installations. It is not supported and may result in unexpected controller behavior. Note: HP recommends that you do not REDUCED command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for information on removing - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 93
. The unit switches are described under the SET unit-number command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. One unit switch, ENABLE/DISABLE_ACCESS_PATH, determines which host connections can access the unit - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 94
R1. 3. Enter the following command to turn off the flashing LEDs: LOCATE CANCEL 94 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 95
M1 M5 DISK ID Disk10000 Disk10100 Disk10200 Disk10300 Disk10400 Disk10500 Disk10800 Disk11000 Disk11100 Disk11200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 95 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 96
. ■ Unit D102 is a 2-member mirrorset named M3. M3 consists of Disk10200 and Disk20200. 96 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 97
named M7. M7 consists of Disk11200 and Disk21200. ■ Disk31200 and Disk41200 are spareset members. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 97 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 98
Planning Storage Configurations 98 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 99
■ Making a Physical Connection, page 104 ■ Installing Solution Software Packages, page 108 ■ Creating and Tuning File Systems, page 113 Refer to Chapter 4 for instructions on how to install and configure the HSG Agent. The Agent for HSG is operating system-specific and polls the storage. HSG80 ACS - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 100
the disk enclosure handles to lift the enclosure. The handles cannot support the weight of the enclosure. Only use these handles to position the StorageWorks Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide and the StorageWorks Model 4300 Family Ultra3 LVD Disk Enclosures User Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 101
unused bays. Fibre Channel cabling information is shown to illustrate supported configurations. In a dual-bus disk enclosure configuration, disk enclosures dual-bus system and Figure 34 for a single-bus system. Note that the supported cable lengths are 1, 2, 3, 5, and 10 meters. 5. Connect the AC - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 102
Channel Ports Figure 33: Dual-Bus Enterprise Storage RAID Array Storage System CXO7383A 102 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 103
6 Cable 8 Fibre Channel Ports Figure 34: Single-Bus Enterprise Storage RAID Array Storage System HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 103 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 104
manual ■ Appropriate tools to service your computer The host bus adapter board plugs into a standard PCI or Sbus slot in the host computer. Refer to the system manual for instructions yet configured for compatibility with Sun Solaris. The HP Solutions Software consists of the packages shown in Table - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 105
Preparing the Host System Table 12: StorageWorks Solution Software Packages Package CPQfcraid CPQfcaw and 9. QLA2300 QLogic PCI driver for Solaris 2.6, 7, 8, and 9. HPfcraid SWCC StorageWorks RAID Manager version 3.0D. SWCC for Windows NT 4.0 workstation. HSG80 ACS Solution Software - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 106
.Z from the web site http://h18006.www1.hp.com/products/storageworks/ma8kema12k/kits.html. 2. Copy or move the Load the CPQptisp package (optional, only required to support legacy RAID systems attached to an SBS-450 SCSI for configuration instructions. 106 HSG80 ACS Solution Software V8 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 107
disk space will be used by the logfiles in the /var/adm/steam directory. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 107 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 108
■ The install option "Select mode automatic or manual [A,m] :" has been removed. The option has packages using: pkginfo | egrep "CPQ|QLA|fca|HP" and pkgrm all found packages. Installing RAID Manager from the web site http://h18006.www1.hp.com/products/storageworks/ma8kema12k/kits.html. 2. Move the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 109
before the HSG80 Solution Software, the Sun native qlc (Qlogic) driver will bind to HP FCA2257x (Qlogic) HBAs and the QLA2200 or QLA2300 driver will fail to attach. on the system and are being used by another package: /etc/inet/services /etc/nsswitch.conf /etc/syslog.conf /etc/system Do you want to - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 110
files for adapters can be selected automatically or manually. - Choose "M" to manually edit your file. You can choose what FC adapters and what targets will be supported. By default, LUNs 0 through 15 are 110 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 111
use of the fdisk utility may be found in the Sun 2.x Adding and Maintaining Peripherals Manual. Labeling a LUN Automatically Using the Format Utility Sun Solaris releases 2.6 and later can automatically HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 111 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 112
about the creation of format.dat entries may be found in the Sun Solaris 2.x Adding and Maintaining Peripherals Manual. Note: Although the format command will create an HSG80 disk entry in the format.dat file, do HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 113
to upgrade. 2. Verify operating system versions, upgrade operating systems to supported versions and patch levels. 3. Quiesce all I/O and unmount all the purpose of performing upgrades to the ACS firmware, this Solution Software Kit supports previous ACS V8.6 and V8.7. Do not mix ACS versions in the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 114
HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide the upgrade). Note: Rolling upgrades are not supported on Sun Solaris when using Qlogic HBAs. following web site and follow the upgrade instructions in the enclosed documentation. Secure Path - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 115
Preparing the Host System HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 115 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 116
Preparing the Host System 116 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 117
to the HSG80 controller. The following information is included in this chapter: ■ Why Use StorageWorks Command Console (SWCC)?, page 118 ■ Installation and Configuration Overview, page 119 ■ About the . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 117 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 118
Configuring the HSG Agent Why Use StorageWorks Command Console (SWCC)? StorageWorks Command Console (SWCC) enables runs on Windows Server 2003 (32-bit), Windows 2000 with Service Pack 3 and 4, and Windows NT 4.0 with Service Pack 6A or above. ■ The Agent obtains the status and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 119
entries (TCP/IP network connections). See Appendix B. Set up pager notification (TCP/IP network connections). Refer to "Setting Up Pager Notification" in the HP StorageWorks Command Console Version 2.5, User Guide. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 120
the LAN. If you have a WAN or a connection to the Internet, monitor the subsystem with TCP/IP. Note: SWCC does not support the dynamic host configuration protocol (DHCP) or the Windows Internet Name Service (WINS). 120 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 121
6 HSG80 controller and its device subsystem 7 Servers Figure 35: An example of a network connection HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 121 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 122
). Verify that your system meets the minimum requirements by completing the following steps. 122 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 123
web site. 1. Go to http://h18006.www1.hp.com/products/storageworks/ma8kema12k/kits.html. 2. Select the kit for download used for first-time configuration or upgrades. It guides you through the configuration of your Agent. It 124 for instructions on running Config.sh. HSG80 ACS Solution - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 124
first-time configurations, run the install.sh script from the $basedir/steam/bin directory (usually /opt/steam/bin). This script will guide you through the following actions: ■ Adding a subsystem entry ■ Adding a Client entry ■ Creating a password ■ Setting up email notification ■ Starting the Agent - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 125
configuration privileges will be asked for this password when attempting to configure the subsystem. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 125 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 126
. 5. Add an Error Notification Level (1 for TCP sockets, 2 for SNMP, or 3 for both). 126 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 127
in troubleshooting subsystem problems. To receive RAID Manager messages, you must enable "email notification" within the Agent Configuration program. For more information on how to decipher mail messages from RAID Manager, refer to HP StorageWorks Command Console Version 2.5, User Guide. HSG80 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 128
Installing and Configuring the HSG Agent 128 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 129
and that the PCMCIA cards are installed. To install a controller or cache module and the PCMCIA card, see the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 130
maintenance port cables when not communicating with the controller through the local connection. 130 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 131
Enter. 5. Press Enter again, and the CLI prompt appears, similar to the following: HSG80> HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 131 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 132
part of the configuration procedure ("Configuring a Single Controller Using CLI" on page 133). 132 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 133
(Node IDs and Port IDs)" on page 56 for the location of the sticker. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 133 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 134
the following command syntax: SET THIS SCSI_VERSION=SCSI-2, or SET THIS SCSI_VERSION=SCSI-3 134 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 135
to replace the battery, answer "Y": Do you intend to replace this controller's cache battery? Y/N [N] Y HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 135 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 136
as changing the CLI prompt. See the SET THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for the format of optional settings. 4. Verify that all commands have taken effect. Use - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 137
(10 seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 ....... HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 137 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 138
to communicate with the Fibre Channel switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable and Verify Connections 6. Plug the Fibre ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 139
as part of the configuration procedure ("Configuring a Controller Pair Using CLI" on page 140). HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 139 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 140
IDs and Port IDs)" on page 56, for the location of the sticker. 140 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 141
the SCSI version to SCSI-32 using the following command: SET THIS SCSI_VERSION=SCSI-2 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 141 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 142
as changing the CLI prompt. See the SET THIS CONTROLLER/OTHER CONTROLLER command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for the format of optional settings. Perform this step on both controllers. 142 HSG80 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 143
FC Configuration Procedures 15. Verify that all commands have taken effect by entering the following command: SHOW THIS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 143 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 144
seconds) Mirrored Cache: Not enabled Battery: NOUPS FULLY CHARGED Expires: 25-JUN-2003 144 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 145
switches through Telnet, set an IP address for each switch. See the manuals that came with the switches for details. Plugging in the FC Cable name ANGEL1A1 to connection !NEWCON01, enter: RENAME !NEWCON01 ANGEL1A1 HP recommends using a naming convention, see "Naming Connections" on page Guide 145 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 146
are accessible. Configuring Devices The disks on the device bus of the HSG80 can be configured manually or with the CONFIG utility. The CONFIG utility is easier. Invoke CONFIG with the following command 150 146 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 147
of 128: ADD STRIPESET STRIPE1 DISK10000 DISK20000 DISK30000 INITIALIZE STRIPE1 CHUNKSIZE=128 SHOW STRIPE1 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 147 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 148
-NAME DISKNNNNN DISKNNNNN SWITCHES Note: See the ADD MIRRORSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the mirrorset switches. 2. Initialize the mirrorset, specifying any desired - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 149
FC Configuration Procedures Note: See the ADD RAIDSET command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the RAIDset switches. 2. Initialize the RAIDset, specifying any desired switches: - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 150
See "Specifying Initialization Switches" on page 89 for a description of the initialization switches. 150 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 151
free space available to the partition. Note: See the CREATE_PARTITION command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide for a description of the partition switches. 3. Verify the partitions: SHOW STORAGESET-NAME - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 152
command qualifiers, which are discussed in detail under the ADD UNIT command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface (CLI) Reference Guide. Because of different SCSI versions, refer to the section "Assigning Unit Numbers Depending - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 153
to the controller should it need to replace a failed member of a RAIDset or mirrorset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 153 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 154
disk drive is automatically initialized and placed into the spareset. If initialization fails, the disk drive remains in the failedset until you manually delete it from the failedset. To enable autospare, use the following command: SET FAILEDSET AUTOSPARE 154 HSG80 ACS Solution Software V8.8 for - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 155
are associated with it. Remember to update the storageset profile when changing its switches. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 155 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 156
example, the following command enables write protection for unit D100: SET D100 WRITE_PROTECT 156 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 157
complex configurations, with Fibre Channel's ability to support transmission lengths in terms of miles/kilometers, the problems of design, installation, testing and documentation require ■ Hubs ■ Switches HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 157 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 158
the desired I/O quantity, it may not support a desired performance characteristic of the I/O. Thus, both configuration and performance can be best described with some test trials of a specific configuration. 158 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 159
is a RAID Array that is supported by the HSG80 controller. This controller supports all of the standard RAID set one controller fails, the second controller will automatically service the I/O stream, protecting data integrity. Typically, Solaris Installation and Configuration Guide 159 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 160
enabling the loop to continue to function. Note: Because cascading hubs are not supported, the largest supported loop configuration using hubs consists of 12 ports maximum. Switches Switches enable multiple 160 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 161
The most common problem encountered when adding a switch to the fabric is domain overlap, especially when interconnecting old (StorageWorks Fibre Channel) switches and new (StorageWorks SAN) switches. Every . HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 161 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 162
on the ALPAs of the controller ports to define the SCSI Targets that Solaris binds to. The StorageWorks Solution software installation process (or the Config.sh utility) will create entries in the /kernel/drv 162 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 163
it and record the various connections and paths. This activity will provide a valuable tool for support of Fibre Channel fabric installations. Loop Connections at the Solaris Level SCSI Target bindings are defined in Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 163 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 164
/sbus@f,e0001000/fcaw@1,0" Target=64 lun=15 ww pn="5000-1fe1-0000-13f1"; 164 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 165
the first port on the HSG80 controller. The /opt/steam/bin/config.sh Utility When installing the StorageWorks RAID Manager Software, a utility script file is loaded onto the system. While installing the kit, HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 165 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 166
installed, the user has the opportunity to define the specific type of Fibre Channel configuration for each adapter, either loop or fabric (QLogic HBAs are supported in fabric-mode only). 166 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 167
configuration file, fca.conf, fcaw.conf, fca-pci.conf, qla2200.conf, or qla2300.conf. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 167 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 168
modify by entering the NN (numeric identification at the left in the list). 168 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 169
FC Configuration Procedures Option 5 - View Available WWPNs Select this option to run the Scan Adapters Utility. This utility detects available adapters and WWPNs for this host. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 169 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 170
loop mode. When you implement loop mode, the ALPAs are used for access. 170 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 171
, otherwise the Target will be suppressed. ■ Driver fcaw for adapter fcaw. - Target: 64, WWPN HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 171 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 172
server must be rebooted with the ( -r) reconfigure switch. Enter the following command: # reboot -- -r 172 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 173
■ The server in question has an adapter to support the Fibre Channel loop or fabric. ■ A storage system is available that will support a fibre connection. ■ Hubs and switches are available boot. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 173 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 174
change was made to the server or controller.) Reconfiguring from Loop to Fabric Note: QLogic HBAs are supported in fabric-mode only. Note: This procedure assumes that the Solaris platform kit is loaded and everything ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 175
the units of the subsystems are now available. Reconfiguring from Fabric to Loop Note: QLogic HBAs are supported in fabric-mode only. Note: This procedure assumes that the Solaris platform kit is loaded and everything Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 175 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 176
FC Configuration Procedures 5. At the servers, reconfigure the adapters to support loop. This is accomplished with /opt/HPfcraid/bin/config.sh, Option 4, Modify Adapters. This option are now available. 176 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 177
resulting virtual system, from the host's point of view, is shown in Figure 43. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 177 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 178
port 2 of both controllers are on another). Therefore, each adapter has two connections. 178 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 179
44 represents an example of virtual system layout from the hosts' point of view. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 179 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 180
cable from maintenance terminal into top controller. CLEAR CLI SET FAILOVER COPY=THIS 180 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 181
Plug in the Fibre Channel cable from the adapter in host "PURPLE." SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 181 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 182
ADAPTER_ID=XXXX-XXXX-XXXX-XXXX 1 XXXXXX OL 0 other ADAPTER_ID=XXXX-XXXX-XXXX-XXXX 182 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 183
XXXX RENAME !NEWCON02 TAN1B2 SET TAN1B2 OPERATING_SYSTEM=SUN SET TAN1B2 UNIT_OFFSET=120 SHOW CONNECTIONS HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 183 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 184
=XXXX-XXXX-XXXX-XXXX Mark or tag both end of Fibre Channel cables. 184 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 185
D101 DISK50300 DISABLE_ACCESS_PATH=ALL SET D101 ENABLE_ACCESS_PATH=(WHITE1B2) ADD SPARESET DISK60300 SHOW UNITS FULL HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 185 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 186
Using CLI for Configuration 186 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 187
Backing Up, Cloning, and Moving Data This chapter includes the following topics: ■ Backing Up Subsystem Configurations, page 188 ■ Creating Clones for Backup, page 189 ■ Moving Storagesets, page 195 7 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 187 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 188
is backed up. Note: Do not use SAVE_CONFIGURATION in dual redundant controller installations. It is not supported and may result in unexpected controller behavior. The SHOW DEVICES FULL command shows which disk drives ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 189
, you can back up the clones rather than the storageset or single-disk unit, which can continue to service its I/O load. When you are cloning a mirrorset, CLONE does not need to create a temporary mirrorset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 189 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 190
you want to use for the clone units. 7. Back up the clone unit. 190 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 191
C_MA MEMBERS=2 SET C_MA REPLACE=DISK20200 DEVICES AVAILABLE FOR CLONE TARGETS: DISK20300 (SIZE=832317) HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 191 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 192
ID is the 64-bit Fibre Channel node id of the controller pair. 192 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 193
WWID associated with the source unit instead of allocating a new one. CLI> run clonew HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 193 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 194
one linked WWID variation. If the linked WWID is already in use, then a new unique WWID is allocated. Manual Clone Creation - The user has his own set of scripts that create clones, and wants to update them to 194 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 195
the release notes for the version of your controller software for information on which drives can be supported. Caution: Never initialize any container or this procedure will not protect data in the storageset. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 195 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 196
cabinet DELETE D100 DELETE RAID99 DELETE DISK10000 DELETE DISK10100 DELETE DISK20000 DELETE DISK20100 196 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 197
Backing Up, Cloning, and Moving Data New cabinet ADD DISK DISK10000 ADD DISK DISK10100 ADD DISK DISK20000 ADD DISK DISK20100 ADD RAIDSET RAID99 DISK10000 DISK10100 DISK20000 DISK20100 ADD UNIT D100 RAID99 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 197 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 198
Backing Up, Cloning, and Moving Data 198 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 199
Enclosure, page 212 ■ Storage Map Template 9 for the Model 4354R Disk Enclosure, page 214 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 199 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 200
Read Source ___Least busy (default) ___Round robin ___Disk drive: Metadata ___Destroy (default) ___Retain 200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 201
Subsystem Profile Templates Unit Switches: Caching Access by following hosts enabled Read caching__________ Read-ahead caching_____ Write-back caching______ Write-through caching____ HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 201 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 202
D30100 D40100 D50100 D60100 Power Supply D10000 D20000 D30000 D40000 D50000 D60000 2 Targets 1 0 202 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 203
D10900 D20900 D30900 D40900 D50900 D60900 Power Supply 8 D10800 D20800 D30800 D40800 D50800 D60800 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 203 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 204
D31300 D41300 D51300 D61300 Power Supply 12 D11200 D21200 D31200 D41200 D51200 D61200 204 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 205
Disk20000 Disk20100 Disk20200 Disk20300 Disk20400 Disk20500 Disk20800 Disk20900 Disk21000 Disk21100 Disk21200 Disk21300 Disk21400 Disk21500 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 205 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 206
Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 206 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 207
Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 DISK ID HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 207 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 208
Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 DISK ID 208 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 209
11 12 DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 209 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 210
12 DISK ID Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk31000 Disk31100 Disk31200 210 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 211
11 12 DISK ID Disk40000 Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk41000 Disk41100 Disk41200 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 211 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 212
Disk40100 Disk40200 Disk40300 Disk40400 Disk40500 Disk40800 Disk40900 Disk41000 Disk41100 Disk41200 Disk41300 Disk41400 Disk41500 212 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 213
Disk30000 Disk30100 Disk30200 Disk30300 Disk30400 Disk30500 Disk30800 Disk30900 Disk31000 Disk31100 Disk31200 Disk31300 Disk31400 Disk31500 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 213 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 214
Disk50100 Disk50200 Disk50300 Disk50400 Disk50500 Disk50800 Disk60000 Disk60100 Disk60200 Disk60300 Disk60400 Disk60500 Disk60800 214 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 215
Client?, page 216 ■ Before You Install the Client, page 217 ■ Installing the Client, page 218 ■ Installing the Integration Patch, page 219 ■ Troubleshooting Client Installation, page 221 ■ Adding Storage Subsystem and its Host to Navigation Tree, page 223 ■ Removing Command Console Client, page 225 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 216
an individual device (JBOD) ■ Monitor many subsystems at once ■ Set up pager notification 216 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 217
the software product description that came with the software for a list of supported hardware. 3. Verify that you have the SNMP service installed on the computer. SNMP must be installed on the computer for 4. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 217 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 218
subsystems, StorageWorks recommends you install both, but one at a time. This problem is not instructions on the screen. After you install the software, the Asynchronous Event Service (AES) starts. AES is a service HP StorageWorks Command Console Version 2.5, User Guide. 218 HSG80 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 219
. 2. Verify that you have installed HSG80 Storage Window version 2.1 in the Add/Remove Programs (StorageWorks HSG80 V2.1) in the Windows Control Panel. The HSG80 Storage Window version 2.1 is required to run HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 219 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 220
CIM integration patch (HSG80 Insight Manager Shim). 2. Verify that you have installed the CIM Agent and the StorageWorks Command Console HS-Series Agent on the same computer. 3. Add the name of the client system that ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 221
Services tab. 2. Highlight the entry for Fibre Array Information and click Add. The Fibre Array Information entry is moved from Inactive Agents to Active Agents. Troubleshooting Client Installation This section provides information on how to resolve some of the problems manually to the services - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 222
to add the correct ports. The following shows how the network port assignments appear in the services file: spgui ccdevmgt kzpccconnectp ort kzpccdiscover yport ccfabric spagent spagent3 ccagent spagent2 4998/tc p 4993 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 223
Agent on the storage subsystem host. 2. Click Start > Programs > Command Console > StorageWorks Command Console. Client displays the Navigation Window. The Navigation Window lets you monitor and manage Close. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 223 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 224
the Storage Window icon. Figure 48: Navigation window showing expanded "Atlanta" host icon 224 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 225
HP StorageWorks Command Console Version 2.5, User Guide. Removing Command Console Client Before you remove the Command Console Client (CCL) from the computer, remove AES. This will prevent the system from reporting that a service the instructions on the screen. HSG80 ACS Solution Software - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 226
You can find additional information about SWCC by referring to the online Help and to HP StorageWorks Command Console Version 2.5, User Guide. About the User Guide HP StorageWorks Command Console Version 2.5, User Guide contains additional information on how to use SWCC. Some of the topics in the - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 227
on a removable ROM program card that provides the operating system for the array controller. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 227 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 228
header. A method used to bring a system or device into a defined state by means of its own action. For example, a machine routine whose first few instructions are enough to bring the rest of the routine into the computer from an input device. 228 HSG80 ACS Solution Software V8.8 for Sun Solaris - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 229
. Stripesets and mirrorsets are examples of storageset containers the controller uses to create units. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 229 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 230
and execution monitor. A generic reference to large subsystem cabinets, such as the cabinets in which StorageWorks components can be mounted. The process of segmenting logically sequential data, such as a single file, Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 231
extends the range of a single-ended SCSI cable to the limit of a differential SCSI cable. A StorageWorks SCSI bus signal converter used to connect a variety of 16-bit single-ended devices to hosts with speeds. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 231 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 232
Fibre Channel Fabric Generic Requirements Fibre Channel Framing Protocol (HIPPI on FC) Fibre Channel Generic Services-1 Fibre Channel Generic Services-2 Fibre Channel Implementation Guide Fibre Channel Link Encapsulation (ISO 8802.2) The Fibre Channel Physical and Signaling standard. Fibre Channel - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 233
block contains unrecoverable data. An invisible unit used to transfer information in Fibre Channel. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 233 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 234
heterogeneous host support HIPPI-FC host host adapter HBA Field replaceable unit. A hardware component that can be replaced at the customer location by service personnel or qualified customer service personnel. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 235
detected. A set of protocols used between components, such as cables, connectors, and signal levels. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 235 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 236
number. LUNs use their target bus connection to communicate on the SCSI bus. 236 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 237
and media defect management for the disk drive. It is also used to support storageset configuration and partitioning. Nontransportable disks also contain metadata to indicate they are uniquely configured for StorageWorks environments. Metadata can be thought of as "data about data." The act of - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 238
the mirrorset. Read requests from the host are always satisfied by normal members. 238 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 239
in participating mode. A logical division of a container, represented to the host as a logical unit. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 239 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 240
card is about the size of a credit card. Power distribution unit. The power entry device for StorageWorks cabinets. The CDU provides the connections necessary to distribute power to the cabinet shelves and fans. Any HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 241
information across all of the disk drives within the storageset. See also RAID level 3. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 241 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 242
background. Data warehousing, continuous computing, and enterprise applications all require remote copy capabilities. 242 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 243
the "target". The rate at which requests are arriving at a servicing entity. Radio frequency interference. The disturbance of a signal by an StorageWorks building block. (1) A modular carrier plus the interface required to mount the carrier into a standard StorageWorks and Configuration Guide 243 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 244
of storing data, whether it is a physical device or a group of physical devices. 244 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 245
and array controllers in StorageWorks enclosures to form storage subsystems. StorageWorks systems include integrated SBBs relation to a timing signal. See also asynchronous. A storage device supporting sequential access to variable sized data records. (1) A SCSI device and Configuration Guide 245 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 246
drive. A unit may also be created from a more complex container such as a RAIDset. The controller supports a maximum of eight units on each target. See also target and target ID number. Sometimes called unflushed HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 247
the cache memory accordingly, to ensure that the cache contains the most current data. HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 247 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 248
Glossary 248 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 249
152 assignment of unit numbers fabric topology Index partition 152 single disk 152 asynchronous event service 226 autospare enabling fabric topology 154 availability 81 B Back up, Clone, Move Data switches HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 249 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 250
56 conventions document 18 creating storageset and device profiles 75 creating and tuning 250 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 251
failover mode 50 disabling access paths 51 separate links 50 host adapter installation 104 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide 251 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 252
UNITcommand 47 CLI configuration procedure fabric topology 180 fabric topology configuration cabling 139 252 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 253
89 maximum membership 83 planning considerations 81 important points 82 switches 88 read caching HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide Index 253 - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 254
-enclosure subsystem 211 Storage map template 8 first enclosure of multiple-enclosure subsystem 212 254 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 255
to host connections 45 restricting host access 50 disabling access paths 51 separate links 50 restricting host access by offsets 52 SET CONNECTIONS 45 troubleshooting invalid network port assignments 221 there is no disk in the drive message 222 tuning file system 113 U uninstalling Client 225 unit - HP StorageWorks EMA16000 | HP StorageWorks HSG80 ACS Solution Software V8.8 for - Page 256
38 write-back caching general description 37 write-through caching general description 37 256 HSG80 ACS Solution Software V8.8 for Sun Solaris Installation and Configuration Guide
Installation
and
Configuration
Guide
HP
StorageWorks
HSG80 ACS Solution Software
V8.8
for Sun Solaris
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA-RV1RA-TE
This guide provides installation and configuration instructions and reference material for
operation of the HSG80 ACS Solution Software V8.8-1 for Sun Solaris.