HP StorageWorks MA8000 HP StorageWorks HSG80 Enterprise Modular Storage RAID A
HP StorageWorks MA8000 Manual
View all HP StorageWorks MA8000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MA8000 manual content summary:
- HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 1
Release Notes HP StorageWorks HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun Solaris Product Version: 8.8-1 First Edition (March 2005) Part Number: AA-RV1SA-TE This document contains last-minute and supplemental information about your Solution Software. In - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 2
in this document is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 3
■ ACS Enhancements and Fixes, page 11 ■ Solution Software Updates, page 29 ■ Documentation Updates, page 30 ■ Hardware and Software Support, page 30 ■ ACS Feature Support, page 37Host Operating System Notes, page 38 ■ ACS Anomalies, page 46 HSG80 Enterprise Modular Storage RAID Array Fibre Channel - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 4
Intended Audience Intended Audience This document is intended for storage administrators and HP authorized service personnel who install and maintain HP StorageWorks Enterprise or Modular Storage RAID Array products that include HP StorageWorks HSG80 RAID Array Controllers. Conventions The following - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 5
Abbreviations and Acronyms Abbreviations and Acronyms The following abbreviations and acronyms are used throughout this document: ■ ACS-Array Controller Software ■ CCL-Command Console LUN ■ CLI-Command Line Interpreter ■ EISA-Extended Industry Standard Architecture ■ EMU-Environmental Monitoring - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 6
Maintenance and Service Guide, EK-G80MS-SA.C01 - HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide, EK- - Installation and scripting utilities - Device drivers The following supporting documentation is available from the HP StorageWorks web site http - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 7
Channel Arbitrated Loop Configurations Application Note ■ Model 2100 and 2200 Ultra SCSI Controller Enclosures User Guide ■ Model 4300 Family Ultra3 LVD Disk Enclosures User Guide ■ Modular Array Cabinet Restrictions HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8 - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 8
upgrade instructions as documented in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide to prevent data loss or corruption. If at any time you encounter problems during the upgrade, contact your HP support representative. 8 HSG80 - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 9
SWCC V2.5) or EVA V3.0C (includes SSSU). Note: Any multiple storage system configuration that includes EVA VCS V2.x or 3.x requires multi-bus support. See "Secure Path Software" on page 35 for compatible Secure Path versions. ACS V8.8-1 compatible Secure Path versions and HBA drivers are compatible - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 10
New Features New Features This section briefly describes new features and changes of this release. New Features for Solution Software V8.8-1 The following major enhancements are included in the 8.8-1 release of the Solution Software Kit. ■ SUN Solaris 2.6, 7, 8, and 9-CPQ/JNI driver V2.6.13; QLogic - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 11
new units through the CLI requires you to manually disable connections. Combines several existing commands to allow you to output and transfer relevant and helpful controller configuration information needed by HP service representatives before and during a support call. Assigns World Wide ID (WWID - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 12
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 4. CLI Command or Switch HOST_REDUNDANT NOHOST_REDUNDANT Description and Background Turns on and off the capability to redirect the host to the redundant unit copy for the original requested unit data after the - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 13
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 5. DESTROY_MBR Description and Background Removes the 8 MB partition from a presented LUN and destroys the master boot record (MBR) present on new or replacement spares, HP-manufactured - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 14
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 6. FAKE_PR Description and Background Note: Use the FAKE_PR switch for maintenance or recovery operations only. If set on a unit, allows the controller to signal to host systems - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 15
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item CLI Command or Switch 7. REINITIALIZE container-name Description and Background Invokes maintenance actions against initialized containers and modifies container metadata. Also modifies the prior device - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 16
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 8. CLI Command or Switch REINITIALIZE container-name TURNSAVEOFF 9. REINITIALIZE container-name SPECIAL_FUNCTION_ONE=INFO Description and Background Disables the option to save configuration information for - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 17
ACS Enhancements and Fixes Table 1: New CLI Commands and Switches (Continued) Item 10. CLI Command or Switch REINITIALIZE container-name SPECIAL_FUNCTION_ONE= PARTITION Description and Background Directs the controller to set the partition flag bits on all devices in a container and establishes - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 18
OTHER CONTROLLER. Note: Refer to Chapter 4 of the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Maintenance and Service Guide for additional details related to this command. 18 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 19
code (6A) prompts you to use specific steps to resolve the problem associated with exceeding the maximum number of host connections. Refer to the HP StorageWorks Array Controller and Array Controller Software Troubleshooting Guide for additional details. New ASC and ASCQ code The following table - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 20
and HSG80 Array Controller and Array Controller Software Troubleshooting Guide for additional information. SHOW CONNECTIONS FULL command array controller subsystems. Configuration changes to disk drive SMART attributes now support HP standards. SMART events are now only reported as recovered errors - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 21
(the base version). No other versions are supported. With this, changes have been made to associated screens. Contact HP support for additional information. Note: If you are Controller and Array Controller Software Command Line Interface Guide for additional information. Note: Since Tru64 UNIX host - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 22
mounted by Tru64 UNIX (that is, units mounted by another supported operating system). New display information after entering the DISPLAY RESOURCES StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Troubleshooting Guide. Table 3: New FMU Commands and Switches Item 1. - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 23
of events in the controller non-volatile memory (NVMEM). Displays pertinent information relative to a controller crash and can be used by an HP service representative to help identify the cause of a controller crash. This command invokes the SHOW LAST ALL FULL FMU command. HSG80 Enterprise Modular - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 24
failover 2. New LFC OE199001 and updates to Repair Code 90 Description The problem involving the loss of the initiator WWID on remote copy set (RCS) units with this issue was recursive. Repair Code 90 has updated troubleshooting steps to handle the following Recursive Bugcheck error scenarios: - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 25
drive error handling improvement Description Follow these steps to troubleshoot the above Recursive Bugcheck error scenarios: 1. On "the has been fixed to substantially reduce issues surrounding controller inoperability problems resulting from the installation of bad disk drives into a subsystem - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 26
send and receive diagnostic commands to the controller and resulting in LFC 64030104 has been resolved. The issue involving controller inoperability problems while using FRUTIL which resulted in LFC 018F2087 has been resolved. An issue involving a controller inoperability event, as a result of an - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 27
attempted, refer to the REINITIALIZE command in the HP StorageWorks HSG60 and HSG80 Array Controller and Array Controller Software Command Line Interface Reference Guide for help. The RUN CONFIG command has been improved and now skips bad disk drives after the command is submitted and completes its - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 28
ACS Enhancements and Fixes Table 4: ACS fixes (Continued) Item 22. Subject Controller port TACHYON chip malfunction 23. Excessive abort messages logged by the host 24. Fibre Channel (FC) switch goes port INSYNC state to HSG Description With earlier versions of ACS, controller port TACHYON chip - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 29
currently installed drivers. ■ The install option "Select mode automatic or manual [A,m] :" has been removed. The option has been replaced with appropriate | egrep "CPQ|QLA|fca|HP" and pkgrm all found packages. ■ Added support for Secure Path V3.0D software. ■ The Sun Solaris required patch list has - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 30
Solution Software: ■ The section "FC Switch Updates" was removed along with the Fibre Channel Switch Support table. Switch support information is available in the HP SAN Design Reference Guide at http://h18006.www1.hp.com/storage/saninfrastructure.html. ■ New document Enterprise and Modular Storage - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 31
/storageworks/softwaredrivers/acs/ 2. Select the manuals (guides, supplements, addendum, etc) link under self-help resources. 3. Select the HSG60, HSG80, HSJ80, HSZ80 Supported Disk Drive Matrix link. Switch Support This Fibre Channel Solution Kit supports the Fibre Channel switches and firmware - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 32
Hardware and Software Support Table 6: Minimum System Requirements (Continued) SCSI Protocol SCSI-2 SCSI-3 Failover Mode Transparent Multi-Bus (requires Secure Path software) Host Mode SUN Disk Space 150 MB - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 33
Hardware and Software Support Table 7: Sun Solaris Patch Requirements Host Feature Requirement Required Patches Solaris 2.6: 112542-01, 106125-16, 105181-35, 106226-03, 105356-23, 105210-51, 107665-01, - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 34
Version 2.5 User Guide and the Command Console Version 2.5 Release Notes. SWCC Scalability ■ The SWCC Client can monitor up to 128 host systems, each with up to 32 storage systems, for a maximum of 4096 concurrent storage connections and a total of 2.65 PB of storage. ■ One Agent can support up to - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 35
HP SANworks Network View HP SANworks Storage Allocation Reporter Application version V4.0B V1.0B V1.0C V2.0D V3.0A V2.0B V1.0D Supported ACS versions and variants V8.8-1F V8.8-1F/S/P V8.8-1F/S/P V8.8-1F/S/P V8.8-1F V8.8-1F/G/S/P V8.8-1F In cases where ACS functional builds other - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 36
Hardware and Software Support More information and specific product documentation on storage management software is available at the HP StorageWorks website: http://h18006.www1.hp.com/storage/software.html - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 37
ACS Feature Support ACS Feature Support The following sections provide details for specific ACS features. SCSI Chapter 1 in the HP StorageWorks HSG80 ACS Solution Software Installation and Configuration Guide. HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 for Sun - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 38
uninstall all 3R-A351x-AA Series HBA drivers in use, which will allow Secure Path to correctly rediscover units. SCSI-3 Mode V8.8-1 Solution Software supports connections using SCSI-3 mode. A SCSI generic driver is not supplied, so the CCL LUNs are ignored. The Solaris server loses the ability to - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 39
services file will be used. Maximum Supported Storageset Size With this release, Solaris can support storagesets up to 1.024 TB with the following limitations: ■ You cannot enter the LUN logical geometry manually Large SAN Considerations If you are having problems seeing LUNs, typically on a large - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 40
memory requirements have increased. A minimum of 256 MB of memory is required in the Sun server before loading the FC adapter drivers. Maximum Supported HBAs per System Board For Sun Enterprise machines (including E3000, E3500, E4500), the maximum number of adapters that may be installed in any - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 41
an adapter. 3. Select the adapter that you want to modify. 4. Follow the instructions to modify the number of LUNs/Target. Note: Do not enter more than 64 recognizes LUN 0 on each target. The HP RAID Manager software adds support for 16 LUNs per target, but Solaris still allows 256 queued commands - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 42
with a high number of large disks, the controller may specify a geometry that exceeds the parameters supported by the format command. The maximum values supported by Solaris (when manually configuring geometry) are: ■ 32,767 cylinders (including 2 alternate cylinders) ■ 64 heads ■ 256 sectors per - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 43
Host Operating System Notes To properly configure a storageset where the logical geometry exceeds these values, follow these steps: 1. Get the size of the storageset by performing a SHOW on the unit from the CLI on the array controller (e.g. SHOW D100). This results in a display with the following - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 44
system does not have enough virtual memory to fsck a large device. This is a known problem with fsck. The solution is to add swap space with the swap -a command. HP controller has not been tested and is not supported. 44 HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8.8 - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 45
and 2.6. This message is incorrect and should be ignored. See "System Components" on page 31, for supported O/S levels. Note: Virtual Disk Wizard in multi-bus failover mode is not supported with the Secure Path driver. HSG80 Enterprise Modular Storage RAID Array Fibre Channel Solution Software V8 - HP StorageWorks MA8000 | HP StorageWorks HSG80 Enterprise Modular Storage RAID A - Page 46
ACS Anomalies ACS Anomalies If you issue the INITIALIZE SAVE_CONFIGURATION CLI command on a JBOD disk to save the controller configuration while the unit is not above the container, the command appears to work, but the save operation does not occur. You must place the unit above the JBOD, and then
Release Notes
HP
StorageWorks
HSG80 Enterprise Modular Storage RAID
Array Fibre Channel Solution Software
V8.8
for Sun Solaris
Product Version:
8.8-1
First Edition (March 2005)
Part Number:
AA-RV1SA-TE
This document contains last-minute and supplemental information about your Solution
Software. In the event of conflicting information between these Release Notes and other
documents contained in this product release, the Release Notes content takes precedence. For
the latest version of these Release Notes and other product documentation, visit the HP web site
at
.