- HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 1
User Guide This guide provides information about installing, configuring, restoring, and managing the HP StorageWorks IP Distance Gateway (mpx110). It is intended for system administrators responsible for installing, managing, and servicing the mpx110 and the SAN to which it is attached. Part Number - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 3
checklist ...40 Rack mounting the mpx110 ...40 Installing the SFPs ...41 Management ...42 Installing the management application 42 HP StorageWorks mpx Manager for Windows 43 HP StorageWorks mpx Manager for Linux 43 Setting mpx110 management port parameters 43 IP Distance Gateway User Guide 3 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 4
...53 Replacing an mpx110 ...53 Services ...55 Security ...55 Diagnostics and troubleshooting 56 POST diagnostics ...56 Heartbeat LED (green) ...56 Input Power LED (green) ...57 System Fault LED (amber) ...57 Fibre Channel Port LEDs ...57 4 Using the HP StorageWorks mpx Manager utility 59 Overview - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 5
A Command-line interface 93 Logging on to the mpx110 ...93 User accounts ...93 Working with SAN mpx110 configurations 93 Modifying a configuration 93 Saving and restoring log messages ...131 Application modules ...131 iSCSI driver ...133 Fibre Channel driver ...134 IP Distance Gateway User Guide 5 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 6
driver ...139 System ...139 Error log messages ...139 Application modules ...139 iSCSI driver ...145 Fibre Channel driver ...147 Error log messages in user modules 149 System ...150 Fatal log messages ...151 iSCSI driver ...151 Fibre Channel driver ...152 TOE driver ...154 System ...154 C Simple - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 7
173 Modifications ...173 Cables ...174 Regulatory compliance identification numbers 174 Laser device ...174 Laser safety warning 174 Laser notice ...176 Korean notice ...176 Safety ...176 Battery replacement notice 176 Taiwan battery recycling notice 177 Power cords ...177 Japanese power cord - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 8
21 13 mpx110 IP Distance Gateway FCIP with C-series IVR 22 14 HP Continuous Access EVA 3-site configuration with four mpx110 gateways 23 15 HP Continuous Access EVA 3-site configuration with six mpx110 gateways 24 16 HP Continuous Access EVA 3-site configuration with eight mpx110 gateways 25 17 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 9
Wizards menu ...79 44 mpx Selection dialog box 80 45 Firmware File Selection dialog box 80 46 Confirm Changes dialog box 81 47 Finish dialog box (successful firmware update 81 48 FCIP Routes Add Wizard-FC and GigE dialog 88 58 Class 1 laser product label 174 IP Distance Gateway User Guide 9 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 10
messages 133 21 FC driver-Informational log messages 134 22 User modules-Log messages 136 23 FCIP-Informational log messages 138 iSCSI driver-Error log messages 145 28 FC driver-Error log messages 147 29 User modules-Error log messages 149 30 System-Error log messages 150 31 iSCSI driver- - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 11
33 TOE driver-Fatal log messages 154 34 System-Fatal log messages 154 35 SNMP properties 155 36 SNMP parameters 155 IP Distance Gateway User Guide 11 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 12
12 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 13
EVA or XP software, the mpx110 provides long-distance remote replication for disaster tolerance. A base FCIP configuration consists of a minimum of two mpx110 gateways-one for the local site and one for the remote site. A single mpx110 gateway is HP part number AG680A-HP StorageWorks User Guide 13 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 14
FC frames over an IP network. From the perspective of the local and remote fabrics, the FC devices accessed through the gateways appear to be part of one unified fabric. This effect is possible because FC traffic is carried over the IP network in such a way that the FC fabric and - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 15
result in a loss of connectivity between the fabrics. See FCIP fully redundant, high-availability configuration. Figure 2 FCIP fully redundant, high-availability configuration . IP Distance Gateway User Guide 15 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 16
16 Overview - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 17
EVA 3-site configuration with four gateways, page 23 • HP Continuous Access EVA 3-site configuration with six gateways, page 24 • HP Continuous Access EVA 3-site configuration with eight gateways, page 25 Figure 3 One pair of gateways with single-path connectivity . IP Distance Gateway User Guide - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 18
Figure 4 One pair of gateways with redundant fabrics . Figure 5 One pair of gateways, two long-distance links . Figure 6 Redundant pairs of gateways, one long-distance link . 18 Configuration rules and guidelines - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 19
Figure 7 Redundant pairs of gateways, two long-distance links . Figure 8 Redundant pairs of gateways, fully redundant long-distance links . Figure 9 Highly redundant pairs of gateways, two long-distance links . IP Distance Gateway User Guide 19 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 20
Figure 10 Highly redundant pairs of gateways, fully redundant long-distance links . Figure 11 Basic configuration, MPX200 FCIP with remote IP Distance Gateway (mpx110) . 20 Configuration rules and guidelines - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 21
implemented in all supported mpx110 FCIP configurations using HP StoramgpexW10o0rks FC1 FC2 MGMT GE1 IOIOI GE2 ! E mpx110 Fabric A2 Remote FC servers Local storage system Figure 12 mpx110 FCIP with B-series Integrated Routing . Remote storage system 26626a IP Distance Gateway User Guide - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 22
merging the fabrics. This can be implemented in all supported mpx110 FCIP configurations using C-series Fibre Channel switches with IVR. servers GbE VSAN A1 E HP StoramgpexW10o0rks FC1 FC2 MGMT GE1 IOIOI GE2 ! mpx110 WAN FCIP LAN GbE HP StoramgpexW10o0rks FC1 FC2 MGMT GE1 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 23
1 can function as the remote site. • Replication between Site 2 and Site 3 is not supported. The following configuration rules apply to Figure 17 (peer-to-peer relationship): • For Site 1, 14 HP Continuous Access EVA 3-site configuration with four mpx110 gateways . IP Distance Gateway User Guide 23 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 24
the same long-distance link redundancy as the configuration shown in Figure 14, with the addition of redundant mpx110 gateways at sites 2 and 3. Figure 15 HP Continuous Access EVA 3-site configuration with six mpx110 gateways . 24 Configuration rules and guidelines - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 25
configuration shown in Figure 16 provides the highest 3-site redundancy, with a dedicated mpx110 pair for all long-distance links to all three sites. Figure 16 HP Continuous Access EVA 3-site configuration with eight mpx110 gateways . IP Distance Gateway User Guide 25 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 26
with six gateways and full inter-site connectivity Figure 17 provides long-distance link redundancy and full connectivity between all three sites. Figure 17 HP Continuous Access EVA 3-site configuration with six gateways, full peer-to-peer connectivity . 26 Configuration rules and guidelines - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 27
FCIP with all operating systems and multipath software supported by HP. For more information, see the HP StorageWorks SAN Design Reference Guide, available at http://www.hp.com/go/SDGManuals. EVA storage system rules and guidelines Observe the following EVA storage system rules and guidelines: • The - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 28
as HP StorageWorks Continuous Access EVA, Command View EVA, Business Copy, SSSU, and Replication Solutions Manager. XP storage system rules and guidelines Observe the following XP storage system rules and guidelines: • Supported XP models are XP24000/20000 and XP12000/10000, with supported firmware - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 29
remote pairs are supported for up to 100 ms of IP network delay one-way, or 200 ms round-trip for HP Continuous Access EVA. HP requires dedicated IP bandwidth " in the HP StorageWorks SAN Design Reference Guide. • For mpx110 IP management-LAN and WAN are supported. IP Distance Gateway User Guide 29 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 30
and VCS Specification Description Bandwidth1 Must be dedicated to the HP Continuous Access storage replication function. There is no support for dynamic pacing of the gateway. Maximum number of DR groups See Table 1 for minimum supported bandwidth based on the average packet-loss ratio and one - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 31
HP StorageWorks Continuous Access EVA supports them. In addition to support for Jumbo frames, you can select other and configure the MTU size between 1000 and 9000 bytes. NOTE: Jumbo frames are not supported for use with HP Continuous Access EVA or XP Continuous Access. IP Distance Gateway User Guide - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 32
Compression The mpx110 integrates a software compression option. Enable compression for IP fabrics with an RTT greater than or equal to 50 ms, or guaranteed WAN bandwidth of less than or equal to 45 Mb/s. See "TCP window size recommendations" on page 34 for compression options for specific network - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 33
Table 3 TCP window size scale factors MWS scale result 0 to 2 2 to 4 4 to 8 8 to 16 16 to 32 32 to 64 64 to 128 128 or greater Scale factor 0 1 2 3 4 5 6 7 IP Distance Gateway User Guide 33 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 34
). For higher-loss, longer-latency networks, you should reduce the recommended window size and scaling factor by one setting to compensate for the increased number of packet retransmissions. Table 4 T1 / DS-1: 1.554 Mb/s nl Round-trip time 200 100 50 25 20 15 10 5 2.5 1 or less Total window size - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 35
ON ON ON ON ON ON ON ON ON ON Compression recommendations ON ON ON OFF OFF OFF OFF OFF OFF OFF IP Distance Gateway User Guide 35 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 36
Table 7 OC-1: 50 Mb/s nl Round-trip time 200 100 50 25 20 15 10 5 2.5 1 or less Total window size (bytes) 2 MB 1 MB 512 K 128 K 128 K 128 K 64 K 32 K 32 K 32 K Table 8 100-BASE T: 100 Mb/s nl Round-trip time 200 100 50 25 20 15 10 5 2.5 1 or less Total window size (bytes) 4 MB 2 MB 1 MB 512 K - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 37
or OFF ON or OFF OFF OFF OFF OFF OFF Compression recommendations ON ON ON OFF OFF OFF OFF OFF OFF OFF IP Distance Gateway User Guide 37 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 38
Table 11 OC-12 and above: 621 Mb/s nl Round-trip time 200 100 50 25 20 15 10 5 2.5 1 or less Total window size (bytes) 4 MB 4 MB 4 MB 2 MB 2 MB 2 MB 1 MB 512 K 256 K 64 K nl Scaling factor 7 7 7 6 6 5 5 4 3 1 Compression recommendations ON ON ON OFF OFF OFF OFF OFF OFF OFF 38 Configuration - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 39
Upgrade (mpx110 for redundancy), Part Number: AG681A • Optical SFPs and FC cables, two per site NOTE: For the latest information about the minimum system requirements, see the HP StorageWorks IP Distance Gateway release notes, available at http://www.hp.com/support/manuals. Under Storage, select - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 40
Service, and VLAN/Priority) For more information, see "Configuring FCIP routes" on page 48. • mpx110 serial console cable adapter • HP StorageWorks of the C-Shelf with its screw hole tab pointing outboard and its lip supporting the C-Shelf. Mount both right-hand and left-hand slide brackets. c. - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 41
, in the center mounting holes, install two nuts (KEPs 10-32, 0.375AF CSZ EXT). c. Carefully supporting the C-Shelf assembly, loosely thread the knurled thumbscrews through the rack into the two nuts just installed. d. gently until the transceiver snaps into place. IP Distance Gateway User Guide 41 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 42
Supported HP StorageWorks mpx Manager. Table 12 mpx Manager server requirements Component Operating system Requirement Windows 2003, 2008 or XP MAC OS X Linux • SUSE LINUX Enterprise Server 10 (x86) • SUSE LINUX Enterprise Server 9 (x86) • SUSE LINUX Enterprise Server 8 (x86) • Red Hat Enterprise - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 43
HP StorageWorks mpx Manager on a Linux server. NOTE: In the following procedure, replace n.n.nn and n.n.nnbnnn with a file name (for example, 2.0.30 and 2.0.30b112). 1. Download the installation instructions on the be 10.0.0.x, where x is a number other than 1, and the subnet mask User Guide 43 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 44
does not illuminate. Figure 18 shows the location of the ports and LEDs on the mpx110. Figure 18 mpx110 ports and LEDs . See "Diagnostics and troubleshooting" on page 56 for a description of the LED fault indications. 44 Installation and upgrades - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 45
the login prompt. b. Enter password at the password prompt. NOTE: HP recommends changing the mpx110 guest password after logging in. Figure 19 Setting at the mpx110 prompt. 6. Enter the default password, config. NOTE: HP recommends that you change the mpx110 Admin password after logging in. 7. Enter - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 46
StorageWorks Fibre Channel switch parameters. Modify the switch settings listed below based on the switch product line used. All settings apply to HP Continuous Access EVA and XP unless noted otherwise. B-series Fibre Channel switch parameters Execute the commands in Table 13 for all switches that - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 47
Switch(config)# exit EVA and XP C-Switch# copy run start EVA and XP Configuring the mpx110 for connecting remote SANs Verify the SAN configuration requirements: • At least one FC port of each mpx110 should be connected to an FC SAN. • Use FC WWPN-based zoning. IP Distance Gateway User Guide 47 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 48
Mb/s. See "IP performance tuning" on page 31 for link speed and delay information. NOTE: With the exception of the tuning parameters listed above, HP strongly recommends that you use the default mpx110 settings shown in Figure 20. Configuring the FCIP routes using the CLI For each mpx110, configure - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 49
(Figure 22). A warning message appears. Figure 22 FCIP Route Add wizard . 5. Click Yes to continue. The FC & GigE Port Selection screen appears. IP Distance Gateway User Guide 49 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 50
6. Select the FC/GE ports to configure. As an option, you may enter the GE port speed and flow control parameters. Click Next to continue. The Local & Remote IP Address screen appears. 7. Enter the local GE port IP address, subnet mask, gateway and the IP address of the remote mpx110. Click Next to - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 51
"Supported Firmware Upload window, click the Select button to browse and select the firmware file to be uploaded. 3. Click the Start button to begin the firmware load process. A message appears warning you that the mpx110 will be reset to activate the firmware. IP Distance Gateway User Guide - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 52
example: User (172.17.137.190:(none)): ftp331 Guest login ok, type your name as password.Password: ftp230 Guest login ok, access restrictions apply. 3. At the ftp prompt, enter bin to set the binary mode. For example: ftp> bin200 Type set to I. 4. Issue the put command to transfer the firmware image - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 53
: • Save all firmware image files (updates) in a safe place, because you may: • Revert to a previous firmware version • Need the firmware image when replacing an mpx110 • Need the firmware image when adding an and restoring the mpx110 configuration" on page 169. IP Distance Gateway User Guide 53 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 54
The newly installed mpx110 is connected and ready for use. 54 Installation and upgrades - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 55
of your environment using a variety of mpx110 services. Familiarize yourself with the following mpx110 services and determine which ones you need: • operator for a password whenever a change is attempted. The CLI requires a user name and password to start. All set operations require an active Admin - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 56
Diagnostics and troubleshooting Diagnostic information about the mpx110 is available through , page 57 Figure 23 Locating LEDs . POST diagnostics The mpx110 completes a series of tests as part of its POST procedure: • Memory • FLASH validation • PCI device discovery • Management Ethernet port - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 57
(amber) The System Fault LED illuminates to indicate that a fault exists in the mpx110 firmware or hardware. Fault conditions include POST errors and over-temperature conditions. Also check the Heartbeat alert (port fault) condition except at power on or reboot. IP Distance Gateway User Guide 57 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 58
58 Installation and upgrades - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 59
mpx Manager, the software tool used to manage the mpx110. Overview The HP StorageWorks mpx Manager enables you to manage the mpx110 gateway, and to monitor, configure, and modify information from tabs (see Figure 24 and Table 16). Figure 24 mpx Manager main window . IP Distance Gateway User Guide 59 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 60
double-click the entry to expand or collapse a system tree entry. Shows the corresponding information, configuration, or status for the selected tab. 60 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 61
GUI Figure 26 File menu . View menu The View menu displays the View Logs option (Figure 27), which opens the system logs. IP Distance Gateway User Guide 61 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 62
Figure 27 View menu . 62 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 63
firmware image. The firmware image is selected from a menu that enables browsing. • FCIP Route Add-Launches the FCIP Route Add wizard, which enables you to select the resources used for the route, the IP address of the remote FCIP peer, IP parameters, VLAN support supported by the gateway at - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 64
gateway to the system tree view • Logs-Opens a window to display the system log data • Refresh-Updates the display with current information 64 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 65
. NOTE: Figure 32 shows features not supported at the time of this document's release of the remote FCIP peer, IP parameters, VLAN support, compression, and bandwidth limit • FCIP Route Update Wizard-Launches a wizard for updating the gateway's firmware • Beacon ON-Turns on the mpx110 beacon to - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 66
Figure 32 Action menu . 66 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 67
System tree window Figure 33 shows the System tree window. The System tree window is located in the left-most window pane and displays the connected mpx110 gateways and the FCIP routes for each gateway. Figure 33 System tree window . IP Distance Gateway User Guide 67 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 68
For example, select FCIP Routes in the System tree to see component data in the tabbed pages to the right of the tree (Figure 34). Figure 34 FCIP Route Info . 68 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 69
to display basic product information. Click the icon to access the following settings (Figure 36): • Product Name-HP StorageWorks model mpx110 • Symbolic Name-A symbolic name you can create for the gateway • Serial Number-Serial number of the gateway • Hardware Version-The gateway hardware version - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 70
Obtain an IP address automatically (DHCP) button is set, the default gateway IP address displayed is the address obtained automatically through DHCP. 70 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 71
not selected, select to configure the IP local link address. • Set IP Address-Save any IP address changes. Figure 36 Management Information . IP Distance Gateway User Guide 71 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 72
NTP server to be queried. • Set NTP Address-Saves changes made to the NTP server IP addresses. Figure 37 NTP Server Information . 72 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 73
correctly. • Apply-Save the password changes. • Clear Fields-Clear the Current Password, New Password, and Verify Password fields. Figure 38 Security tab . IP Distance Gateway User Guide 73 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 74
to which the SNMP traps are sent. A maximum of eight trap addresses are supported. • Trap Port-Specifies the port number on which the trap is sent. The default is 162. • Trap Version-Specifies the SNMP version (1 or 2) with which to format traps. 74 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 75
FCIP route. NOTE: Change to the following settings do not take effect until you click Save at the bottom of the page. IP Distance Gateway User Guide 75 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 76
Number-Provides a dialog box that enables the user to define the destination TCP port number used by the FCIP route. This port number VLAN support. The default is Disabled. • VLAN ID-Provides a dialog box that enables the user to 15 Mb/s. HP StorageWorks Continuous Access EVA/XP replication solution - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 77
Figure 40 FCIP Route Info . IP Distance Gateway User Guide 77 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 78
window appears. Figure 42 mpx Manager main window . 3. See "Using wizards" on page 79 for the steps for setting additional mpx110 parameters. 78 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 79
from the Wizards menu: • FW Update Wizard-Updates the mpx110 gateway firmware • FCIP Route Add-Launches the FCIP Route Add wizard, which enables route, the IP address of the remote FCIP peer, IP parameters, VLAN support, compression, and bandwidth limit • FCIP Route Remove-Launches the FCIP Route - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 80
, and then click Next. 3. Enter the path to the firmware file, or click Browse to locate the firmware file. The Firmware Image File box appears, displaying the firmware file. 4. Click Next to continue. Figure 45 Firmware File Selection dialog box . 80 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 81
a copy of the firmware configuration: a. Click firmware update. The Firmware Update Status firmware loads successfully, the Finish dialog box and Update success dialog box appear. The new firmware will not take effect until the system is rebooted. Figure 47 Finish dialog box (successful firmware - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 82
FCIP Route Add Wizard The FCIP Route Add Wizard provides step-by-step instructions for adding an FCIP route. IMPORTANT: When the FCIP Route Add Wizard launches, a warning ). Figure 48 FCIP Routes Add Wizard-FC and GigE Port Selection dialog box . 82 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 83
other than Auto. 4. After selecting a port pair and setting GE port parameters, click Next to continue or Cancel to exit the wizard. IP Distance Gateway User Guide 83 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 84
IPv6 Address-The IP address assigned to the GigE port on the remote gateway. An uninitialized port has an IP address of "::". 84 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 85
and 7 • VLAN Enabled-Provides a dialog box for enabling and disabling VLAN support. The default is Disabled. • VLAN ID-Provides a dialog box that enables the user to define the VLAN ID (available only when VLAN is enabled). The continue or Cancel to exit the wizard. IP Distance Gateway User Guide 85 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 86
port during transmits. The range of values supported is 1 to 1,000 Mb/s. This setting enables the user to limit the bandwidth used by the FCIP link bandwidth, set the bandwidth to 15 Mb/s. HP StorageWorks Continuous Access EVA/XP replication solution requires dedicated bandwidth for the intersite - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 87
box . FCIP Route Remove The FCIP Route Remove wizard provides step-by-step instructions for removing a FCIP route. To remove an FCIP route: 1. When the selected GE and FC ports. Connectivity on the GE port that is not part of the FCIP route being removed will be momentarily disrupted (Figure 55). If - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 88
completion of the route remove operation (Figure 57). 5. Click OK to exit the dialog box. Figure 57 Remove FCIP Route Completed dialog . 88 Using the HP StorageWorks mpx Manager utility - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 89
View EVA online help • HP StorageWorks SAN Design Reference Guide • HP StorageWorks 4400 Enterprise Virtual Array User Guide • HP StorageWorks 6400/8400 Enterprise Virtual Array User Guide • HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array User Guide • HP StorageWorks Enterprise Virtual Array - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 90
. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. HP technical support Telephone numbers for worldwide technical support are listed on the HP support website: http:// www.hp.com/support/. Collect the following information before calling - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 91
by selecting Business support and then Storage under Product Category. Other HP websites For additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.docs.hp.com • http://www.hp.com/go/sandesignguide IP Distance Gateway User Guide 91 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 92
92 Support and other resources - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 93
• 8-bit character • 1 stop bit • No parity • No flow control User accounts The mpx110 ships with the following user account already defined: Account name: guest Password: password Both should be changed the mgmt FCIP route configuration uses the following commands: IP Distance Gateway User Guide 93 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 94
to retrieve the saved mpx110 configuration data: c:\>ftp 172.17.137.102 Connected to 172.17.137.102. 220 (none) FTP server (GNU inetutils 1.4.2) ready. User (172.17.137.102:(none)): ftp 331 Guest login ok, type your name as password. Password: ftp 230 Guest login ok, access restrictions apply. ftp - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 95
ftp 172.17.137.102 Connected to 172.17.137.102. 220 (none) FTP server (GNU inetutils 1.4.2) ready. User (172.17.137.102:(none)): ftp 331 Guest login ok, type your name as password. Password: ftp 230 Guest Always use the Full Configuration Restore with the mpx110. IP Distance Gateway User Guide 95 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 96
Commands The command syntax is as follows: command keyword keyword [value] keyword [value1] [value2] The command is followed by one or more parameters. Consider the following rules and conventions: • Commands and parameters are not case sensitive. • Required keyword values appear in standard font - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 97
. The following example shows how to start and end an Admin session: mpx110 #> admin start Password: ****** mpx110 (admin) #> . . . mpx110 #> admin end mpx110 #> IP Distance Gateway User Guide 97 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 98
Beacon command Enables or disables flashing the Heartbeat and System Fault LEDs. The Heartbeat and System Fault LEDs are flashed synchronously (they are turned on and off together). No other LEDs are affected. Authority Syntax Parameters None beacon on Turns on the mpx110 beacon Example off - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 99
Syntax Parameters Admin session fciproute add Configures a new FCIP route mod Modifies an existing FCIP route rm Removes an existing FCIP route IP Distance Gateway User Guide 99 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 100
Examples The following is an example of the fciproute add command: mpx239 (admin) #> fciproute add A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 101
GE2 2FC1 GE1 Please select an FCIP route from the list above ('q' to quit): 1 FCIP Route 1 has been removed from the system. IP Distance Gateway User Guide 101 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 102
save creates a .tar file containing the mpx110's persistent data, configuration and LUN mappings, storing the file in the mpx110's /var/ftp directory. The user must then FTP the .bin file from the mpx110. The following is an example of the fru restore command: mpx110 (admin) #> fru restore A list - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 103
[ chap | fc | fciproutes features | initiators | iscsi isns | localmaps | logs memory | mgmt | ntp perf | presented_initiators | presented_targets properties | remotemaps | remotepeers snmp | stats | system targets ] IP Distance Gateway User Guide 103 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 104
show chap show fc [ ] show fciproutes [ ] show features show initiators [ fc | iscsi ] show logs show memory show mgmt show ntp show perf [ byte | init_rbyte | init_wbyte | tgt_rbyte | tgt_wbyte ] show statsshow system show properties show snmp show stats show system show - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 105
show vlan [ ] shutdown target [ add | rm ] History command Displays a numbered list of the previously entered commands. Authority Syntax Notes Admin session history Closing a Telnet window #> history 1: admin start 2: help 3: history mpx110 (admin) #> IP Distance Gateway User Guide 105 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 106
the mpx110's /var/ftp directory. These are files transferred by the user when updating the firmware image. list Displays a list of the firmware image files in the mpx110's /var/ftp directory. unpack [] Unpacks the firmware image file specified in the parameter and installs the - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 107
.4ms, Maximum = 109.0ms, Average = 108.5ms mpx239 (admin) #> Quit command Exits the CLI and returns the operator to the login prompt. IP Distance Gateway User Guide 107 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 108
Admin session quit The following is an example of the quit command: mpx110 (admin) #> quit (none) login: Reboot command Restarts the mpx110 firmware. Authority Syntax Example Admin session reboot The following is an example of the reboot command: mpx110 (admin) #> reboot Are you sure you want - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 109
aborted. Set command Configures general parameters, as well as parameters for the FC, iSCSI, and management ports. Authority Syntax Admin session set IP Distance Gateway User Guide 109 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 110
Parameters Example chap Sets CHAP secrets mgmt Sets management port parameters ntp Sets NTP parameters properties Sets CLI properties snmp Sets SNMP parameters system Sets system parameters The following is an example of the set command: mpx110 #>set mgmt 110 Command-line interface - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 111
Configures an FC port. Authority Syntax Parameter Example Admin session set fc [port_num] port_num Sets the number of the FC port to be configured The following is an example of the set fc command: 1 that have been changed will now be saved. mpx239 (admin) #> IP Distance Gateway User Guide 111 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 112
[10.6.7.239] IPv4 Subnet Mask [255.255.248.0] IPv4 Gateway [10.6.4.200] IPv6 Interface (0=Enable, 1=Disable) [Disabled] 0 IPv6 Mode (0=Manual, 1=AutoConfigure) [Manual] IPv6 Address 1 [:: ] 2000:10::32:239:1 IPv6 Address 2 [:: ] IPv6 Default Router [:: ] All attribute values that have been changed - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 113
(0=Disable 1=15min, 2=60min) [Disabled] CLI Prompt (Max=32 Characters) [mpx110 ] RTR1 All attribute values that have been changed will now be saved. IP Distance Gateway User Guide 113 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 114
. It also provides for configuration of up to eight trap destinations. Authority Syntax Parameter Examples Admin session set snmp trap_destinations Sets the number of the trap destinations to be configured for SNMP The following is an example of the set snmp command: mpx110 (admin) #> set - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 115
been changed will now be saved mpx239 (admin) #> Set System command Configures general mpx110 parameters. Authority Syntax Parameter Admin session set system port_num Sets the number of the iSCSI port to be configured for iSNS IP Distance Gateway User Guide 115 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 116
Example The following is an example of the set system command: mpx110 (admin) #> set system A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 117
FC and iSCSI system Shows product information, including serial number, software version, hardware version, configuration, and temperature Product Name QRouter Symbolic Name Rack3 QRouter Mode iSCSI Server Connectivity Mode Serial Number 0539A01070 HW Version 2 SW Version 1.0.5.0 No. of FC Ports 2 No - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 118
Show FcipRoutes command Shows FCIP route configuration parameters. Authority Syntax Parameter Example None show fciproutes [link_id] Sets the number of the FCIP route to be displayed (1 or 2) The following is an example of the show fciproutes command: mpx239 (admin) #> show fciproutes FCIP Route - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 119
8192/8192 Request Blocks 8192/8192 Event Blocks 1024/1024 Control Blocks 256/256 FCIP Buffer Pool 0/0 FCIP Request Blocks 16384/16384 IP Distance Gateway User Guide 119 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 120
The following is an example of the show memory command with one FCIP route configured: mpx110 #> show memory nl Memory Units Free/Total Physical 28MB/251MB Buffer Pool 2176/4224 Process Blocks 4096/4096 Request Blocks 4096/4096 Event Blocks 512/512 Control Blocks 128/128 FCIP Buffer Pool 13320/ - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 121
Address 10.6.7.239 IPv4 Subnet Mask 255.255.248.0 IPv4 Gateway 10.6.4.200 IPv6 Interface Enabled IPv6 Mode Manual IPv6 Address 1 2000:10::32:239:1 IPv6 Address 2 :: IPv6 Link Local fe80::2c0:ddff:fe0d: Mode Disabled Status Offline TimeZone Offset (Hours) 0 IP Distance Gateway User Guide 121 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 122
Show Performance command Displays performance data. Authority Syntax Parameters Example None show perf byte Shows data transfer rate of each port (FC and GE) init_rbyte Shows initiator read transfer rate per port init_wbyte Shows initiator write transfer rate per port tgt_rbyte Shows target read - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 123
snmp SNMP configuration Read Community Public Trap Community Private System Location System Contact Authentication traps System OID 1.3.6.1.4.1.3873.1.4 System Description HP StorageWorks mpx110 Trap Destination 1 IP Address 10.0.0.5 Trap Port 1024 Trap Version 2 IP Distance Gateway User Guide 123 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 124
Show Stats command Displays mpx110 statistics for FC and iSCSI. Authority Syntax Example None show stats The following is an example of the show stats command: mpx110 #> show stats FC Port Statistics FC Port Interrupt Count Target Command Count Initiator Command Count FC Port Interrupt Count - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 125
MAC Rcvd Encoding Errors MAC Rcvd Length Errors Large MAC Rcvd Small Errors Small MAC Rcvd Multicast Frames MAC Rcvd Broadcast Frames IP Distance Gateway User Guide 125 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 126
iSCSI Shared Statistics nl PDUs Xmited Data Bytes Xmited PDUs Rcvd Data Bytes Rcvd I/O Completed Unexpected I/O Rcvd iSCSI Format Errors Header Digest Errors Data Digest Errors Sequence Errors PDU Xmit Count PDU Xmit Count PDU Xmit Count IP Xmit Packets IP Xmit Byte Count IP Xmit Fragments IP Rcvd - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 127
(admin) #> show system System Information Product Name HP StorageWorks mpx110 Symbolic Name mpx239 System Mode SAN Router/FCIP Serial Number MXK813E00R HW Version 6 (IPv6 Supported) SW Version 2.4.3.0 No. of FC Ports 2 No. of iSCSI Ports 2 Temperature (C) 40 IP Distance Gateway User Guide 127 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 128
Show Targets command Shows the targets discovered by the mpx110 for FC, iSCSI, or both. Authority Syntax Parameters Examples None show targets fc Specifies the display of FC targets iscsi Specifies the display of iSCSI targets The following is an example of the show targets fc command: mpx110 #> - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 129
None show vlan [] port_num Specifies the iSCSI port number whose VLAN configuration is to be displayed The following is Priority 0 Shutdown command Provides for an orderly shutdown of mpx110 firmware. This command does not power down the mpx110. Authority Syntax Gateway User Guide 129 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 130
NOTE: The target add command is not currently supported. Authority Syntax Parameter Example Admin session target rm Removes a target from the mpx110 target database The following is an example of the target rm command: - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 131
Index 0x%x, Id 0x%x 1058 Description Router is booting up Decompression failed and will be temporarily disabled User removed a target (iSR6140 or iSR6142) or a target presentation (iSR6142) FC logout occurred, origin = target, 3 = initiator) VP xx, ID (loop ID) x IP Distance Gateway User Guide 131 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 132
.xx.xx.xx.xx.xx FC logout occurred with WWPN xx.xx.xx.xx.xx.xx.xx.xx FC login event notification, VP xx Maximum number of support hosts dd has been reached An iSCSI initiator logged out of a router presented target. An iSCSI initiator logged into a router presented target. Event notification - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 133
iSCSI port link-up at 1000Mb half-duplex iSCSI port link speed could not be determined. Link speed may be incorrectly programmed IP Distance Gateway User Guide 133 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 134
Fibre Channel driver Table 21 lists informational log messages common to both FC ports, 1 (FC1) and 2 (FC2). Log messages beginning with #0 apply to Fibre Channel port 1 (FC1), and log messages beginning with #1 apply to Fibre Channel port 2 (FC2). Table 21 FC driver-Informational log messages ID - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 135
ID 119554 Log message #%d: QLFcipIsrEventHandler: Link mode up (%x) No. 770 Description FCIP-Fibre Channel link up occurred. Event status is reported, as is the RunTimeMode (0 = loop, 1 = point-to-point). IP Distance Gateway User Guide 135 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 136
: Remotemap removed to remote device 349 %.2x:%.2x:%.2x:%.2x:%.2x:%.2x:%.2x:%.2x Description Router firmware upgrade performed, new version number is d.d.d.d. User performed a router reboot or shutdown. FC port configuration has been modified. iSCSI port configuration has been - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 137
User disabled FC port d User added FCIP route #d User modified FCIP route #d User removed FCIP route #d Initiator configuration changed, such as CHAP settings or OS type User removed an initiator from the router. Typically this is done using CLI "initiator rm" command IP Distance Gateway User Guide - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 138
FCIP Table 23 lists log messages provided by the FCIP modules. Table 23 FCIP-Informational log messages ID Log message No. 184524 qlFcip_Linkchange#%d: Gige Link Down 204 184525 qlFcip_Linkchange#%d: Gige Link Up 205 Description FCIP Route GigE link d (1 or 2) is down FCIP Route GigE link - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 139
139 • iSCSI driver, page 145 • Fibre Channel driver, page 147 • Error log messages in user modules, page 149 • System, page 150 Application modules Table 26 lists error log messages provided by command Processing unsupported headof-queue task management command IP Distance Gateway User Guide 139 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 140
during an initiator operation iSCSI Login failed between receipt of PDU and request for the data segment. iSCSI Login failed due to unsupported version number in received login PDU. iSCSI Login PDU contains invalid initiator name. The format and character set used to form the initiator name is - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 141
or iSCSI2 (GE2). The Inquiry command issued by the mpx110 as part of its discovery process failed. The Inquiry command issued by the mpx110 as part of its discovery process failed. The Inquiry command issued by the mpx110 as part of its discovery process failed. IP Distance Gateway User Guide 141 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 142
757 41750 QLBI_Ioctl: ERROR: Operation (0x%x) not supported in this mode 790 41768 QLBI_GetLunList: REPORT LUNS command %.2X%.2X%.2X%.2X 1064 Description The Inquiry command issued by the mpx110 as part of its discovery process failed. The Pass Through command issued by management application ( - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 143
Channel processor encountered a system error (unrecoverable firmware error). Event notification: Fibre Channel driver encountered to allocate iSCSI initiator object while initiating a session. Exceeded the number of iSCSI hosts allowed to connect to mpx100 Failed to execute iSCSI User Guide 143 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 144
ID Log message 43265 QLUT_AllocateTpbExtension: TPB allocation failed No. 2305 43267 QLUT_AllocateTpbExtension: Data buffer allocation failed (length %d) 2307 43268 QLUT_AllocateTpbExtension: Alloc of DSD failed for buffer len %d 2308 43269 QLFCIP_IncomingFrame: BUGCHECK: Trb (0x%p) - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 145
74068 #%d: QLUtmReceiveScsiCmd: Invalid ATIO Continuation type %x 340 Description The iSCSI processor failed firmware initialization. The iSCSI processor command to enable a GE port failed. The iSCSI port failed. iSCSI FW did not send a valid Continuation IOCB IP Distance Gateway User Guide 145 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 146
ID Log message No. Description 74069 #%d: QLUtmProcessResponseQueue: Immediate data addr %08x:%08x in unsupported PduType 341 Driver received an unsupported pdu type with immediate data address 74241 #%d: QLiSNSEnableCallback: iSNS Server TCP Connect failed 513 The iSCSI processor could - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 147
processor failed to re-initialize in response to an IOCTL disable request. Invalid Virtual Port loop ID The FC processor reported a link down condition. Table B-10 pointer is NULL FC firmware failed to respond to a keep alive command. FC firmware will be restarted. IP Distance Gateway User Guide 147 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 148
of errors encountered. The link has been taken down. The FC processor was unable to obtain the number of loop IDs required. This failure occurs only when the FC processor is running multi-ID firmware. The driver was unable to reestablish connection to the target within the timeout and retry counts - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 149
lists error log messages provided by user modules. Table 29 User modules-Error log messages ID Log message No. 139265 QBRPC_Initialize: Entered 1 139266 139267 139268 API memory allocation failed. Get FC Advanced API memory allocation failed. IP Distance Gateway User Guide 149 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 150
ID 139288 139289 139296 139297 139298 139299 139300 139301 139302 139303 139304 139305 139315 139553 Log message No. QBRPC_Initialize:Init Mem Allocation error 24 QBRPC_Initialize:TgtDevice Mem Allocation error 25 QBRPC_Initialize:FcTgt Mem Allocation error 32 QBRPC_Initialize:BridgeStatus - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 151
reboot timer failed. Port enable reboot timer failed. iSNS response contains an invalid handle. Start iSCSI processor failed. iSCSI processor firmware initialization failed. iSCSI processor port fatal error. Start iSCSI processor reboot timer failed. iSCSI processor fatal system error. IP Distance - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 152
restart. iSCSI processor reboot failed. iSCSI processor NVRAM invalid (checksum error). iSCSI FLASH (NVRAM) command failed iSCSI firmware loader invalid state iSCSI failed to load firmware in time allotted Fibre Channel driver Table 32 lists fatal log messages common to both Fibre Channel ports - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 153
code load failed. FC processor transmit sequencer code load failed. FC processor firmware checksum failed. FC processor firmware initialization failed. FC processor paused due to internal parity error. FC FCIP-Response queue entry contains an invalid entry type IP Distance Gateway User Guide 153 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 154
ID 102749 102752 102755 102800 Log message No. #%d: QLProcessResponseQueueFS: Invalid handle 0x%x, type 0x%x 349 #%d: QLTimer: Ext Ram parity error exceed limit cnt 0x%x, limit 0x%x, Disabled adapter 352 #%d: QLTimer: Heartbeat failed 355 #%d: QLRestartRisc: restart RISC 400 Description - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 155
the mpx110 through third-party applications that support SNMP. The mpx110 firmware supports SNMP versions 1 and 2 and an HP MIB (see "Management Information Base (MIB are sent. A maximum of 8 trap addresses are supported. The default address for traps is 0.0.0.0. IP Distance Gateway User Guide 155 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 156
qsrHwVersion Syntax Access Description SnmpAdminString read-only The system hardware version number qsrSwVersion Syntax Access Description SnmpAdminString read-only The system software (firmware) version number qsrNoOfFcPorts Syntax Access Unsigned32 read-only 156 Simple Network Management - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 157
Unsigned32 read-only The number of GbE ports on the system qsrAgentVersion Syntax Access Description SnmpAdminString read-only The version number of the agent software following sequence of objects: qsrNwPortRole qsrNwPortIndex QsrPortRole unsigned32 IP Distance Gateway User Guide 157 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 158
qsrNwPortAddressMode qsrIPAddressType qsrIPAddress qsrNetMask qsrGateway qsrMacAddress qsrNwLinkStatus qsrNwLinkRate INTEGER InetAddressType InetAddress InetAddress InetAddress MacAddress QsrLinkStatus QsrLinkRate qsrNwPortRole Syntax Access Description QsrPortRole not-accessible The operational - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 159
address for this port QsrLinkStatus read-only The operational link for this port QsrLinkRate read-only The operational speed for this port IP Distance Gateway User Guide 159 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 160
Fibre Channel port table The Fibre Channel port table is a list of the FC ports on the mpx110. qsrFcPortTable Syntax Access Description QsrFcPortEntry not-accessible A list of the FC ports on the mpx110. There are as many entries in this table as there are FC ports on the mpx110. qsrFcPortEntry - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 161
qsrFcPortNodeWwn Syntax Access Description PhysAddress read-only The WWN of the node that contains this port qsrFcPortWwn Syntax Access PhysAddress read-only IP Distance Gateway User Guide 161 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 162
Description The WWN for this port qsrFcPortId Syntax Access Description PhysAddress read-only The interface's 24-bit Fibre Channel address identifier qsrFcPortType Syntax Access Description Unsigned32 read-only The type of a Fibre Channel port, as indicated by the use of the appropriate value - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 163
Description qsrSensorEntry Syntax Access Description A list of all sensors on the mpx110. There are as many entries (rows) in this table as there are sensors. QsrSensorEntry not-accessible Each entry (row) corresponds to a single sensor. IP Distance Gateway User Guide 163 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 164
QsrSensorEntry A sensor entry consists of the following sequence of objects: qsrSensorType qsrSensorIndex qsrSensorUnits qsrSensorValue qsrUpperThreshold qsrLowerThreshold qsrSensorState INTEGER Unsigned32 INTEGER Integer32 Integer32 Integer32 INTEGER qsrSensorType Syntax Access Description - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 165
-notify Indicates the severity of the event. The value clear specifies that a condition that caused an earlier trap is no longer present. IP Distance Gateway User Guide 165 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 166
qsrEventDescription Syntax Access Description SnmpAdminString accessible-for-notify A textual description of the event that occurred qsrEventTimeStamp Syntax Access Description DateAndTime accessible-for-notify Indicates when the event occurred Agent startup notification The agent startup - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 167
other than the defined event types. It provides a description object that identifies the event. qsrGenericEvent uses the following objects: • qsrEventTimeStamp • qsrEventSeverity • qsrEventDescription IP Distance Gateway User Guide 167 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 168
168 Simple Network Management Protocol - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 169
configuration is saved to the selected location. Saving the configuration using the mpx110 CLI To save the configuration using the mpx110 CLI: IP Distance Gateway User Guide 169 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 170
1. Log in to the mpx110 using a Telnet session to the management port or the console port. Username: guest Password: password 2. Enter the following command: mpx110> admin start 3. Enter config as the password. 4. Enter the following command: mpx110 (admin) #> fru save FRU save completed. - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 171
to do so. Type of restore (0=full, 1=mappings only) [full] FRU restore completed. 8. Reboot the system for the configuration to take effect. IP Distance Gateway User Guide 171 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 172
172 Saving and restoring the mpx110 configuration - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 173
and used in accordance with the instruction manual, may cause harmful interference to radio regarding your product, visit http://www.hp.com/. For questions regarding this FCC to the part, Regulatory Model Number, or product number found on the product. Modifications The FCC requires the user to be - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 174
Regulatory Model Number should not be confused with the marketing name or model number of the product. Laser device All HP systems equipped with Do not try to open the laser device enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 175
Flicker • EN60950 (IEC60950)-Product Safety • Also approved under UL 60950/CSA C22.2 No. 60950-00, Safety of Information Technology Equipment. BSMI notice IP Distance Gateway User Guide 175 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 176
or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized service provider. WARNING! Your switch contains an internal lithium manganese - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 177
HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an HP authorized reseller or service provider. Taiwan battery recycling notice The Taiwan EPA requires dry battery Japanese power cord statement IP Distance Gateway User Guide 177 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 178
178 Regulatory compliance and safety - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 179
another. Command sequence number Connecting a server or mpx110 Fibre Channel port to a Fibre Channel switch to access the EVA or XP Fibre shortened cyclic code check used for error detection. Internet Storage Name Service A protocol designed to facilitate the automated discovery, management, and - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 180
Maximum transmission unit Minimum window size Network Time Protocol Quality of service. A traffic management feature. Power distribution unit Power-on working together as a single network adapter; also referred to as teaming. virtual local area network A network of computers that behave as if they - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 181
VP WWN WWPN Virtual port World wide name. A unique identifier assigned to a Fibre Channel device. World wide port name IP Distance Gateway User Guide 181 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 182
182 Glossary - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 183
Index A accounts user CLI, 93 B battery replacement notice, 176 BSMI notice, 175 C cables, 174 Canadian notice, 175 Class A equipment, 175 CLI command admin, 97 traceroute, 130 connectivity rules, 27 operating system, 27 conventions document, 89 text symbols, 90 IP Distance Gateway User Guide 183 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 184
174 declaration of conformity, 173 modifications, 173 H hardware requirements installation, 39 help obtaining, 90 HP storage website, 91 Subscriber's choice website, 91 technical support, 90 I Installation, 39 installation hardware requirements, 39 installing mpx110 manager, 42 international notices - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 185
, 42 Subscriber's choice, HP, 91 switch support model, 28 versions, 28 symbols in text, 90 T Taiwan battery recycling notice, 177 technical support HP, 90 text symbols, 90 U upgrading, 39 W websites HP documentation, 91 HP storage, 91 HP Subscriber's choice, 91 IP Distance Gateway User Guide 185 - HP StorageWorks MPX200 | HP StorageWorks IP Distance Gateway User Guide (5697-03 - Page 186
186
HP StorageWorks
IP Distance Gateway User Guide
This guide provides information about installing, configuring, restoring, and managing the HP StorageWorks
IP Distance Gateway (mpx110). It is intended for system administrators responsible for installing, managing,
and servicing the mpx110 and the SAN to which it is attached.
Part Number: 5697-0376
Seventh edition: April 2010