HP StorageWorks MSA1500cs HP StorageWorks 1500 Modular Smart Array Installatio
HP StorageWorks MSA1500cs Manual
View all HP StorageWorks MSA1500cs manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA1500cs manual content summary:
- HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 1
passive support Controller firmware 7.0 or later, with active/active support Fourth Edition (October 2006) Part Number: 355901-004 This document details procedures for installing an HP StorageWorks 1500 Modular Smart Array controller shelf (MSA1500) and its attached storage enclosures. This guide is - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 2
document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into warranty. Printed in Singapore. HP StorageWorks 1500 Modular Smart Array Installation Guide Fourth Edition (October 2006) Part Number: 355901-004 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 3
32 Spare drives 33 Array sizing (capacity 33 Step 2: Prepare your site 34 Provide adequate structural support for the floor 34 Provide adequate clearance space and ventilation 34 Provide adequate and redundant sources of power 34 HP StorageWorks 1500 Modular Smart Array Installation Guide 3 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 4
installation best practices 37 Step 5: Install the hard drives 43 Step 6: Prepare your servers 44 Step 61 Obtain desired controller firmware and Support Software CD versions 61 firmware (if necessary 71 Configuring the storage 72 4 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 5
98 A Regulatory Notices 99 Regulatory Compliance identification numbers 99 Federal Communications Commission notice 99 Modifications 99 Cables 99 Canadian notice (Avis Canadien 100 European Union notice 100 Japanese notice 100 HP StorageWorks 1500 Modular Smart Array Installation Guide 5 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 6
waste equipment by users in private households in the European Union . . . . . 103 B Electrostatic Discharge 105 Prevention methods 105 Grounding methods 106 C Worksheets 107 Index 121 6 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 7
" on page 107. ■ For information about having HP install and configure your MSA1500, see "Getting help" on page 13. ■ Before configuring your MSA1500, review the information in "Step 1: Review and confirm your plans" on page 17. HP StorageWorks 1500 Modular Smart Array Installation Guide 7 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 8
supplemental information about the MSA), and the compatibility guide (important reference information and specifications). - Go to the Software, Firmware & Drivers page to learn about recent firmware enchancements and support options. 8 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 9
MSA1500 application notes, including instructions for migrating to active/active array controllers (for each supported operating system) Additional related documentation can be found on the following websites: ■ HP SAN Design Guide: http://www.hp.com/go/san HP StorageWorks 1500 Modular Smart Array - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 10
harm or death. Caution: Text set off in this manner indicates that failure to follow directions could result in damage to equipment or data. 10 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 11
symbols indicates the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. WARNING: To reduce the risk of personal injury from electrical shock hazards, , allow the surface to cool before touching. HP StorageWorks 1500 Modular Smart Array Installation Guide 11 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 12
the equipment, observe local occupational health and safety requirements and guidelines for manually handling material. Rack stability Rack stability protects personnel and equipment. WARNING: component is extended for any reason. 12 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 13
Services>HP StorageWorks Disk Arrays includes: ■ Physical installation of the MSA ■ Virtual disk design and configuration of the MSA ■ Service planning ■ Service deployment ■ Installation Verification Testing (IVT) ■ Customer orientation HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 14
/storage.html. From this website, select the appropriate product or solution. HP authorized reseller For the name of your nearest HP authorized reseller, refer to the HP website for locations and telephone numbers: http://www.hp.com. 14 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 15
or configuring the MSA for you, provide them with this guide and verify that they complete the information in "Worksheets" on page 107. ■ For information about HP installing and configuring your MSA, see "Getting help" on page 13. HP StorageWorks 1500 Modular Smart Array Installation Guide 15 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 16
~A ~B 4 Rack the MSA 5 Install the hard drives 6 Prepare the servers 7 Install the HBAs 8 Prepare the switches 9 Connect the cables 10 Power on the devices 11 Configure the MSA Figure 1: Overview of MSA installation procedures 16 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 17
variables affect your decision: ■ Variety of operating systems in the SAN ■ Variety of storage devices in the SAN ■ Number of controllers in this MSA (single or dual) ■ Failover software tool to use (dual-control configurations) HP StorageWorks 1500 Modular Smart Array Installation Guide 17 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 18
firmware Windows HP-UX Linux NetWare OpenVMS Tru64 UNIX SCO VMware Important: Supported operating system and network configuration restrictions exist. For more information, see the compatibility guide on the MSA1500 website: www.hp.com/go/msa1500cs. 18 HP StorageWorks 1500 Modular Smart Array - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 19
meet this requirement. ■ For information on upgrading the MSA to active/active, see the migration instructions for your operating system, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 19 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 20
Verify that the components you plan to use are supported for use with the MSA and your operating system troubleshooting purposes. Note: If a supplier is installing the MSA for you, be sure that they complete these worksheets. 20 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 21
) and collects data for reporting and graphing. HP-SIM is an extensible, standards-based management client software product built on the Storage Management Initiative Specification (SMI-S) for its storage management capabilities. HP StorageWorks 1500 Modular Smart Array Installation Guide 21 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 22
environments running active/active array controller firmware, HP MPIO Full Featured Failover HP Full Featured MPIO. See the MSA1500 compatibility guide for details. The HP full-featured MPIO is provided on the MSA Support Software CD. 22 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 23
-Command Line Interface (ACU-CLI) is a command line interface used to configure an array controller and its storage. The ACU-CLI is primarily used in HP-UX environments. These utilities are provided on the MSA Support Software CD. HP StorageWorks 1500 Modular Smart Array Installation Guide 23 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 24
by plugging one MSA power supply to the UPS on one power source and plug the other MSA power supply to a separate power source. 24 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 25
drivers, always use the drivers and installation scripts provided on the MSA Support Software CD and the MSA1500 website. The MSA will not operate as intended if you update your HBA driver manually or use drivers installing the MSA. HP StorageWorks 1500 Modular Smart Array Installation Guide 25 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 26
6 (ADG) configurations to improve non-random write performance. - Set the controller rebuild priority to medium or high to minimize exposure during a drive rebuild. During a drive rebuild, limit I/O activity from the attached servers. 26 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 27
- Automatic load balancing (Default)-MSA firmware initially assigns ownership of all LUNs to one of the two MSA controllers, and then automatically re-assigns LUN ownership evenly between the controllers based on I/O loads of the LUNs. HP StorageWorks 1500 Modular Smart Array Installation Guide 27 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 28
to the MSA controller. For more information, see the HP StorageWorks 1500 Modular Smart Array Maintenance and Service Guide, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. ■ When servicing one (or both) controllers in a dual-controller MSA, do - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 29
, you must power-cycle the MSA. For more information, see the HP StorageWorks 1500 Modular Smart Array Maintenance and Service Guide, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 29 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 30
and performance expectations ■ Striping methods ■ RAID levels ■ Hard drive sizes and types ■ Spare drives ■ Array sizing (capacity) System and performance expectations To help you offer better I/O performance or storage efficiency. 30 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 31
array uses hard drives from separate storage enclosures and different SCSI buses. In a horizontal configuration, the array uses multiple drives , one or more drives within a LUN can fail without bringing the drive sub-system down. HP StorageWorks 1500 Modular Smart Array Installation Guide 31 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 32
the entire enclosure are reduced to that of the slowest and smallest drive. When hard drives of different sizes are included in a LUN, the LUN defaults to the smallest individual drive size and capacity in the larger drives is unused. 32 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 33
drive in one of the LUNs should fail. If a spare is present and a physical hard drive fails, the spare automatically replaces the failed drive number of drives in an array, the higher the probability of one or more failures in that array. HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 34
HP website: http://h30099.www3.hp.com/configurator. In addition to the following discussion, see Table 4, "MSA1500 specifications" on page 35 for a detailed list of site requirements. Provide adequate structural support for servicing and HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 35
Installation Procedures - All Deployments Table 4: MSA1500 specifications Parameter Dimensions: Height Width Depth Weight Shipping configuration Input dissipation for your installation varies depending on the equipment configuration. HP StorageWorks 1500 Modular Smart Array Installation Guide 35 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 36
" on page 48 for more information. For information about installing the options, refer to the instructions that came with the option kit. Go to Table 10: "MSA1500 Information" on page 108 to record information about your option kits. 36 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 37
is being loaded into the rack above chest level, a third person MUST assist with aligning the system with the rails while the other two people support the weight of the system. HP StorageWorks 1500 Modular Smart Array Installation Guide 37 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 38
insertion of the device into the rack, support the weight of the device and keep it extended. Use the following instructions to install the MSA and its storage enclosures: 1. Use the provided rack template as a guide to indicate where to HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 39
to mark the back of the rack, using the information on the back of the template as a guide. 2. If the holes in the rack uprights are round instead of square, remove the standard pins from end of the rail seats into the rack uprights. HP StorageWorks 1500 Modular Smart Array Installation Guide 39 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 40
retaining bracket and slide the bracket to the farthest position on the rear of the rail. 2 1 e. Repeat steps a through d for the left rack rail. 40 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 41
(1). c. Secure the device to the front of the rack using the provided thumbscrews on the front of the device (2) and then replace the front bezel. 2 1 HP StorageWorks 1500 Modular Smart Array Installation Guide 41 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 42
bracket forward (2) until the tab engages the slot in the chassis. 2 1 b. Tighten the thumbscrew on the bracket. c. Repeat these steps for the other rail. 42 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 43
documentation. For information about installing hard drives, refer to the instructions that came with the hard drive and the enclosure. Go to Table 13: "Hard Drive Information" on page 114 to record information about your hard drives. HP StorageWorks 1500 Modular Smart Array Installation Guide 43 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 44
installing and configuring your servers, refer to the instructions that came with your server and operating system. Go to Table 12: "Server Information" on page 110 to record information about the servers that will connect to the MSA. 44 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 45
obtain it later through the Command Line Interface or by viewing the monitor connected to the server during the server power-on self-test (POST). HP StorageWorks 1500 Modular Smart Array Installation Guide 45 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 46
with the switch for installation and configuration instructions. Go to Table 11: "External Fibre Channel Interconnect Device (Switch) Information" on page 109 to record information about the switches that will connect to the MSA. 46 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 47
without having to read or locate the label. ■ In multi-path configurations, you may want to loosely bind the matching pair of cables connecting devices. HP StorageWorks 1500 Modular Smart Array Installation Guide 47 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 48
Numbers - SCSI 0 A 1 1 B 5 not used 1 A 2 2 B 6 not used 2 A 3 3 B 7 not used 3 A 4 4 B 8 not used Go to Table 13 "Hard Drive Information" on page 114 to record information about each storage enclosure. 48 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 49
3 and Figure 4 for illustrations of sample configurations. Table 5: Supported / Unsupported SCSI cable connections Supported Unsupported SATA 15242 SATA 15264 SATA SATA 15243 SATA SCSI 15245 SCSI 15244 SCSI SCSI 15246 HP StorageWorks 1500 Modular Smart Array Installation Guide 49 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 50
illustration shows the MSA1500 connected to two MSA20 SATA storage enclosures. Note: Tighten the thumbscrews on the SCSI cables to ensure a secure connection. Figure 3: SCSI cable connections to two MSA20 SATA storage enclosures 50 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 51
shows the MSA1500 connected to one dual-bus MSA30 SCSI storage enclosure. Note: Tighten the thumbscrews on the SCSI cables to ensure a secure connection. Figure 4: SCSI cable connections to one MSA30 SCSI storage enclosure HP StorageWorks 1500 Modular Smart Array Installation Guide 51 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 52
either damage the cable or cause performance problems, including intermittent difficulties accessing the storage. ■ Make certain that the Fibre Channel cables are installed and supported so that no excess weight is placed on the connectors. HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 53
in a single-path configuration Figure 5 shows the Fibre Channel cable connections of an MSA1500 being accessed by two servers in a single-path configuration. Figure 5: Sample Fibre Channel cable connections, single-path configuration HP StorageWorks 1500 Modular Smart Array Installation Guide 53 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 54
a multi-path configuration Figure 6 shows the Fibre Channel cable connections of an MSA1500 being accessed by two servers, but in a multi-path configuration. Note: 6: Sample Fibre Channel cable connections, multi-path configuration 54 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 55
the source. Depending on the cause and duration of the power outage, you can use this time to properly shut down your storage sub-system. HP StorageWorks 1500 Modular Smart Array Installation Guide 55 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 56
to the plug, electrical outlet, and the point where the cord is attached to the MSA. Figure 7: Connecting the power cords, using two UPS 56 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 57
prompts to clone the firmware on the controller with the latest version (higher number) over to the controller with the earlier version (lower number) firmware. The following message is and log on as user with administrative control. HP StorageWorks 1500 Modular Smart Array Installation Guide 57 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 58
guide. ■ Remove and reinsert the module. ■ Refer to the HP StorageWorks MSA1500 Maintenance and Service Guide, available on the Documentation CD and the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. 58 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 59
and Service Guide, available on the Documentation CD and the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. Go to Table 10: "MSA1500 Information" on page 108 to record the controller firmware version. HP StorageWorks 1500 Modular Smart Array Installation Guide 59 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 60
storage enclosures To verify that your storage enclosures and hard drives are operating properly, view the enclosure and hard drive LEDs and compare them with the patterns described in documentation that came with the server for help. 60 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 61
Software, Firmware & Drivers page of the MSA1500 website: http://www.hp.com/go/MSA1500cs. Caution: Do not go to the MSA1000 website for information about the MSA1500. 6. Under the Select operating system banner, select the entry for your operating system. HP StorageWorks 1500 Modular Smart Array - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 62
about using the CLI, obtain and refer to the MSA1000/MSA1500 Command Line Interface User Guide. This guide is available on the Documentation CD and the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. 62 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 63
-management/acumatrix/index.html. Note: When creating arrays, the ACU provides suggested settings. Consider these defaults (especially the RAID level and rebuild priority) and make sure that they are acceptable according to your plans. HP StorageWorks 1500 Modular Smart Array Installation Guide 63 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 64
documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. For more information about the ACU, refer to the ACU website: http://h18000.www1.hp.com/products/servers/proliantstorage/ software-management/acumatrix/index.html. 64 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 65
- Linux Environments, page 73 ■ Chapter 4: Configuration Procedures - HP-UX Environments, page 81 ■ Chapter 5: Configuration Procedures - OpenVMS Environments, page 87 ■ Chapter 6: Configuration Procedures - Other Environments, page 93 HP StorageWorks 1500 Modular Smart Array Installation Guide 65 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 66
Installation Procedures - All Deployments 66 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 67
firmware supported for use with the MSA. For a current listing of supported operating system versions, see the QuickSpecs, available on the MSA1500 website: http://www.hp.com/go/msa1500cs MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 67 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 68
to use, page 17 ■ Obtain desired controller firmware and Support Software CD versions, page 61 The installation program scans the server to identify the HBAs and determine which driver to install. This scan may take a few moments. 68 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 69
to review notes and information that supplement this document. Caution: Use only the MSA Support Software CD to install HBA drivers. Drivers for all supported HBAs are included on the CD and are the only versions approved for use with the MSA. HP StorageWorks 1500 Modular Smart Array Installation - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 70
driver (and the included Windows Event Notification Service) Important: After installing the HBA and Event Notification Service drivers, remove the Support Software CD from the CD-ROM drive the HP Array Configuration Utility User Guide. 70 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 71
firmware and Support Software CD versions, page 61 For instructions on updating MSA controller firmware, see the HP StorageWorks Modular Smart Array 1000/1500 firmware updating guide, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. Important - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 72
your chosen configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: Hard Drive Information, page 114 and Table 14: Array (LUN) Information, page 118 to record information about your storage. 72 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 73
firmware supported for use with the MSA. For a current listing of supported operating system versions, see the QuickSpecs, available on the MSA1500 website: http://www.hp.com/go/msa1500cs MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 73 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 74
desired controller firmware and Support Software CD versions" on page 61 4. Mount the CD-ROM drive and view the contents of the CD. 5. Locate and read the readme.txt file to review notes and information that supplement this guide. 74 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 75
Linux Environments 6. To install the HBA drivers: Caution: Use only the Support Software CD to install the HBA drivers. Drivers for all supported HBAs are included on the CD and are the name of the System Management Homepage zip file.) HP StorageWorks 1500 Modular Smart Array Installation Guide 75 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 76
> (Where is the name of the ACU rpm.) Note: Warning messages regarding driver version dependencies may be displayed. These messages do not affect the MSA and may safely be and list the contents of the directory. 76 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 77
is the name of the ACU-CLI rpm.) 10. After all desired components are installed, remove the Support Software CD from the CD-ROM drive. 11. Restart the server. 12. Repeat these procedures for each Linux server that will access the MSA. HP StorageWorks 1500 Modular Smart Array Installation Guide 77 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 78
■ "Obtain desired controller firmware and Support Software CD versions" on page 61 For instructions on updating MSA controller firmware, see the HP StorageWorks Modular Smart Array 1000/1500 firmware updating guide, available on the MSA1500 website: http://www.hp.com/go/msa1500cs. Important: After - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 79
configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: "Hard Drive Information" on page 114 and Table 14: "Array (LUN) Information" on page 118 to record information about your storage. HP StorageWorks 1500 Modular Smart Array Installation Guide 79 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 80
Configuration Procedures - Linux Environments 80 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 81
supported for use with the MSA. For a current listing of supported operating system versions, see the QuickSpecs, available on the web: http://www.hp.com/go/msa1500cs page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 81 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 82
is needed; EMS with active/passive support should already be installed. - In dual-controller active/active configurations, make sure the recent patch that includes support for monitoring active/active MSA is installed on the server. 82 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 83
instructions. ■ LUN configuration notes: - In direct connect environments or in any environment when using the ACU-CLI, a minimum of one storage LUN on the MSA must be configured and set to the HP-UX host mode before connecting the MSA to the HP-UX server. HP StorageWorks 1500 Modular Smart Array - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 84
-s /tmp/HPACUCLI_IA_v7.47-1.depot 6. Remove the Support Software CD from the CD-ROM drive. Note: To start the ACU-CLI, do the following from the console: Navigate to the /opt/compaq/hpacucli/bld directory, and then enter # ./hpacucli. 84 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 85
■ "Obtain desired controller firmware and Support Software CD versions" on page 61 For instructions on updating MSA controller firmware, see the HP StorageWorks Modular Smart Array 1000/1500 firmware updating guide, available on the MSA1500 website: http://www.hp.com/go/msa1500cs. Important: After - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 86
configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: "Hard Drive Information" on page 114 and Table 14: "Array (LUN) Information" on page 118 to record information about your storage. 86 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 87
, page 89 4. Updating MSA controller firmware (if necessary), page 90 5. Configuring the storage, page 91 6. Assigning ID Numbers to the Controllers and LUNs, page 92 page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 87 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 88
FC Port Name1000-0000-C921-5B6EFC Node Name 2000-0000-C921-5B6E 2. Record the WWPNs (FC Port Name in the previous example). WWPN: WWPN 88 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 89
. For instructions, see your version-specific OpenVMS Upgrade and Installation Manual. d. Install the Fibre_SCSI patch on all system disks. For instructions, see the documentation that came with the kit. e. Restart the OpenVMS server. HP StorageWorks 1500 Modular Smart Array Installation Guide 89 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 90
■ "Obtain desired controller firmware and Support Software CD versions" on page 61 For instructions on updating MSA controller firmware, see the HP StorageWorks Modular Smart Array 1000/1500 firmware updating guide, available on the MSA1500 website: http://www.hp.com/go/msa1500cs. Important: After - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 91
utility. Refer to the appropriate user documentation for procedural instructions. Go to Table 13: "Hard Drive Information" on page 114 and Table 14: "Array (LUN) Information" on page 118 to record information about your storage. HP StorageWorks 1500 Modular Smart Array Installation Guide 91 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 92
Controllers and LUNs When configuring your MSA, you must assign a unique ID number to each MSA controller and to each MSA storage LUN. See the HP StorageWorks 1000/1500 Command Line Interface reference guide for specific instructions. 92 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 93
firmware supported for use with the MSA. For a current listing of supported operating system versions, see the QuickSpecs, available on the MSA1500 website: http://www.hp.com/go/msa1500cs MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 93 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 94
c:\nwserver\startup.ncf. b. Add the following entry as the first line in the startup.ncf file: set multi-path support = on c. Locate the following entry and modify it: Old entry LOAD SCSIHD.CDM Modified entry LOAD SCSIHD.CDM /AEN 94 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 95
connection to tru64. ■ For information on upgrading the MSA to active/active, see the migration instructions for Tru64 UNIX environments, available on the Technical documents page of the MSA1500 website: http://www.hp.com/go/msa1500cs. HP StorageWorks 1500 Modular Smart Array Installation Guide 95 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 96
supported. Dual-controller configurations must run active/active firmware. ■ Detailed information about deploying an MSA in a SCO UNIX environment is provided in a separate document on the MSA1500 for each connection to the MSA. 96 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 97
■ "Obtain desired controller firmware and Support Software CD versions" on page 61 For instructions on updating MSA controller firmware, see the HP StorageWorks Modular Smart Array 1000/1500 firmware updating guide, available on the MSA1500 website: http://www.hp.com/go/msa1500cs. Important: After - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 98
utility. Refer to the appropriate user documentation for procedural instructions. Go to Table 13: "Hard Drive Information" on page 114 and Table 14: "Array (LUN) Information" on page 118 to record information about your storage. 98 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 99
number for your storage system. Federal Communications Commission notice This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part accordance with the instructions, may cause HP StorageWorks 1500 Modular Smart Array Installation Guide 99 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 100
(in brackets are the equivalent international standards): ■ EN55022 (CISPR 22) - Electromagnetic Interference ■ EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity ■ EN60950 (IEC950) - Product Safety Japanese notice 100 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 101
are no user-serviceable components inside. ■ Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. ■ Allow only HP Authorized Service technicians to repair the unit. HP StorageWorks 1500 Modular Smart Array Installation Guide 101 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 102
LASER PRODUCT. Battery replacement notice Your MSA1500 is provided with a Lithium Manganese HP Authorized Reseller or your Authorized Service Provider. WARNING: Your Accelerator Array HP, your authorized HP Partners, or their agents. 102 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 103
environment. For more information about where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service or the shop where you purchased the product. HP StorageWorks 1500 Modular Smart Array Installation Guide 103 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 104
Regulatory Notices 104 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 105
or handling parts. A parts on a grounded surface before removing them from their containers. ■ Avoid touching pins, leads, or circuitry. ■ Always make sure you are properly grounded when touching a static-sensitive component or assembly. HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 106
static by touching a piece of sheet metal immediatly before touching the component or the MSA1500. Note: For more information on static electricity, or assistance with product installation, contact your HP Authorized Reseller. 106 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 107
in this section: ■ MSA1500 Information, page 108 ■ External Fibre Channel Interconnect Device (Switch) Information, page 109 ■ Server Information, page 110 ■ Hard Drive Information, page 114 ■ Array (LUN) Information, page 118 HP StorageWorks 1500 Modular Smart Array Installation Guide 107 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 108
MSA1500 Serial number (on the product label) Controller firmware: Version shipped on the controller Version available on the Web Support Software CD: Version shipped with the MSA1500 Version available on the Web MSA1500 WWNN MSA1500 108 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 109
Any Other Interconnect Device Make and model Switch firmware version Switch IP Address Switch WWNN Switch WWPN Any Other Interconnect Device Make and model Switch firmware version Switch IP Address Switch WWNN Switch WWPN HP StorageWorks 1500 Modular Smart Array Installation Guide 109 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 110
kernel Service pack / Errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA connected to your MSA1500. ■ If necessary, create additional copies of this worksheet. 110 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 111
and version / kernel Service pack / Errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA WWNN HBA Configurations: Clustering software and version Cluster cabling HP StorageWorks 1500 Modular Smart Array Installation Guide 111 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 112
and version / kernel Service pack / Errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA WWNN HBA Configurations: Clustering software and version Cluster cabling 112 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 113
and version / kernel Service pack / Errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA WWNN HBA Configurations: Clustering software and version Cluster cabling HP StorageWorks 1500 Modular Smart Array Installation Guide 113 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 114
" on page 118. Note: Worksheets for four (4) storage enclosures are included in this table. ■ Complete one worksheet for each storage enclosure connected to your MSA1500. ■ If necessary, create additional copies of this worksheet. 114 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 115
Speed Array Letter (LUN #) Note: Box numbers are assigned to enclosures based on their connection to the MSA1500. See Figure 2 "SCSI I/O modules, bus numbers, and box numbers" on page 48 for the box number assignment pattern. HP StorageWorks 1500 Modular Smart Array Installation Guide 115 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 116
Worksheets Table 13: Hard Drive Information Box Number Box Number Assigned to this Enclosure ________ Drive Bay 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Transfer Rate Drive Capacity Spindle Speed Array Letter (LUN #) 116 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 117
Table 13: Hard Drive Information Box Number Box Number Assigned to this Enclosure ________ Drive Bay 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Transfer Rate Drive Capacity Spindle Speed Worksheets Array Letter (LUN #) HP StorageWorks 1500 Modular Smart Array Installation Guide 117 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 118
Worksheets Table 14: Array (LUN) Information Basic Settings Array Letter (LUN #) Capacity RAID Level SSP (ACL) Settings HBA WWPN or Name Host Mode (Profile) O/S Share Name 118 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 119
Table 14: Array (LUN) Information Basic Settings Array Letter (LUN #) Capacity RAID Level Worksheets SSP (ACL) Settings HBA WWPN or Name Host Mode (Profile) O/S Share Name HP StorageWorks 1500 Modular Smart Array Installation Guide 119 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 120
Worksheets Table 14: Array (LUN) Information Basic Settings Array Letter (LUN #) Capacity RAID Level SSP (ACL) Settings HBA WWPN or Name Host Mode (Profile) O/S Share Name 120 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 121
supported operating systems 63 audience 8 authorized reseller, HP 14 B battery replacement notice 102 best practices cabling 47 general 24 racking 37 SCSI cable connections 48 box number assignments 48 bus number , MSA-related 9 HP StorageWorks 1500 Modular Smart Array Installation Guide 121 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 122
support 14 HP-UX environments additional notes 82 configuring the storage 86 installing the ACU-CLI 84 prerequisites for the MSA 81 updating MSA firmware 85 I Infrastructure web site 21 Insight Manager web site 21 installing hard drives 122 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 123
HBA driver 74 installing the System Management Home page 75 prerequisites for the MSA 73 updating MSA firmware 78 87 updating MSA firmware 90 operating systems approved versions 44 special configuration tasks 65 upgrading 44 option kits HP StorageWorks 1500 Modular Smart Array Installation Guide 123 - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 124
the MSA 46 verifying the status of 60 symbols in text 10 on equipment 11 System Management Home Page installing in Linux environments 75 T technical support, HP 14 text symbols 10 124 HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 125
HP storage 14 MSA and SAN 21 weight considerations 34 Windows environments configuring the storage 72 installing the ACU 70 installing the ACU-CLI 70 installing the HBA driver 68 prerequisites for the MSA 67 updating MSA firmware 71 Index HP StorageWorks 1500 Modular Smart Array Installation Guide - HP StorageWorks MSA1500cs | HP StorageWorks 1500 Modular Smart Array Installatio - Page 126
Index 126 HP StorageWorks 1500 Modular Smart Array Installation Guide
Installation
Guide
HP StorageWorks 1500
Modular Smart Array
Product Version:
Controller firmware 5.xx or earlier, with active/passive support
Controller firmware 7.0 or later, with active/active support
Fourth Edition (October 2006)
Part Number:
355901-004
This document details procedures for installing an HP StorageWorks 1500 Modular Smart
Array controller shelf (MSA1500) and its attached storage enclosures. This guide is a
companion to the MSA1500 Installation Overview poster.
Note:
Two versions of firmware are available for the MSA1500: active/passive and
active/active. For more information, see
Step 1: Review and confirm your plans
(in this guide)
and the compatibility guides on the MSA1500 website:
.