HP StorageWorks MSA1500cs SCO Operating System support of HP StorageWorks Modu
HP StorageWorks MSA1500cs Manual
View all HP StorageWorks MSA1500cs manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA1500cs manual content summary:
- HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 1
using MSA SAN Switch 2/8 12 Figure 3. A Typical Configuration with a Server and MSA1000 using MSA Hub 2/3 13 Figure 4. A Typical Single-Path Configuration 13 Figure 5. A Typical Multi-Path Configuration 14 Configuring logical volumes on the MSA 15 Installing the HBA Driver...16 Configuring MSA - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 2
, supports MSA20 & MSA30 • Both SCSI and SATA drive support • Easy management MSA1500 Overview The HP StorageWorks 1500cs Modular Smart Array (MSA1500) is a Fibre Channel storage area network (SAN) 2U controller shelf that connects to HP StorageWorks Serial ATA (SATA) and/or SCSI disk enclosures - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 3
View) Reference # Identifier 1 Redundant controller slot blank 2 Primary controller 3 Status indicators 4 Display panel 5 Display push buttons 6 Power switch 7 Unit ID button and indicator MSA1500 cs (Rear View) Reference # Identifier 1 Reserved for future use 2 Primary Fibre - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 4
of two more drive enclosures, it can control up to 42 drives allowing capacity of twelve terabytes. All configuration, management and partitioning and licensing software come standard with no extra charges. HP's exclusive optional embedded 8-port SAN switch or 3-port hub give cost effective and - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 5
1 Redundant Controller Slot Blank 2 Primary MSA1000 Controller 3 Display Buttons 4 Display Panel 5 Display Indicators 6 Status Indicators 7 Power Switch 8 Power Bay(s) MSA1000 (Rear View) Reference # 1 Identifier 2-Gb Small Form Factor Pluggable (SFP) Transceiver 2 Fibre Channel - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 6
when used with MSA1000 and MSA1500 MSA30 Overview The HP StorageWorks Modular Smart Array 30 Enclosure family is the newest HP Ultra320 SCSI disk drive storage enclosure, delivering industry-leading data performance, availability, storage capacity and upgradeability to meet the demanding and growing - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 7
protection • Increases storage density when used with MSA1500 MSA20 Overview The HP StorageWorks Modular Smart Array 20 Enclosure (MSA20) is a SATA 1.5 Gb/s disk drive storage enclosure with Ultra320 SCSI host connectivity. These enclosures deliver industry-leading availability, storage density, and - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 8
) Firmware Version: 1.28 or higher 4. HP StorageWorks Modular Smart Array 30 (P/N: 302969-B21) Firmware Version: CP20 or higher 1. HP MSA SAN Switch 2/8 (P/N: 288247-B21) 2. HP MSA Hub 2/3 (P/N: 286763-B21) 3. StorageWorks Fibre channel Storage Hub 12 (P/N: 295573-001 4. Brocade Silkworm 2040 SAN - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 9
Online ACU is not available for SCO Operating Systems. MSA1000 & MSA1500 can also be configured using Command Line Interface (CLI). For more information on CLI setup and usage, refer to the CLI user guide available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c00149849/c00149849.pdf 9 - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 10
files: MSA1000: http://www.hp.com/go/msa1000 MSA1500: http://www.hp.com/go/msa1500cs 2. Using CLI interface of MSA1000/MSA1500 - Refer to the section titled "Updating MSA controller firmware" in "HP StorageWorks Modular Smart Array 1000/1500 Firmware updating guide" available under "Technical - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 11
Configuring logical volumes on the MSA Installing the HBA driver on the SCO servers Identifying logical volumes to the SCO operating system MSA maintenance Connecting MSA to ProLiant servers running SCO operating systems 3 Item Comments 3 Direct Attach Internal Hub Internal - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 12
The following diagrams illustrate these connectivity types Figure 1. Single Server (Single Path) using the Fibre Channel I/O Module (Direct) Figure 2. A Typical MSA1000 Configuration using MSA SAN Switch 2/8 12 - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 13
Figure 3. A Typical Configuration with a Server and MSA1000 using MSA Hub 2/3 Figure 4. A Typical Single-Path Configuration 13 - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 14
Figure 5. A Typical Multi-Path Configuration 14 - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 15
Comments 3 HP StorageWorks Modular Smart Array (MSA) Command Line Interface document available at http://h20000.www2.hp.com/bc/docs/support/SupportManual/c001498 49/c00149849.pdf provides information to use the Command Line Interface. In order to use the CLI interface, a serial connection needs to - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 16
Software Creating HBA Diskette Comments 3 Refer to the SCO Operating System Deployment Guide for OS installation tips on ProLiant platforms. Update the system with latest Maintenance Pack for OS. Install the HP ProLiant Extended Feature Supplement for SCO UnixWare 7 and OpenServer 6 version 7.70A - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 17
'L' - the Logical Unit Number 'N' - the instance assigned by hp ProLiant CISS 0,0,0: DISK : HP LOGICAL VOLUME 2.58 1,31,0: HBA : (ciss,1) hp ProLiant CISS 2,31,0: HBA : (ciss,1) hp configured to create and mount the file systems. "disksetup" performs the low level activities required to install - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 18
UnixWare 7/OpenServer 6 1. Maximum of two (2) servers per cluster 2. MSA1000 Redundancy 3. MSA1000 Multi-path 4. Online configuration of MSA1000/MSA1500 LUNs 5. Online Firmware upgrade of MSA1000/MSA1500 6. Event logging of MSA1000/MSA1500 7. Systems Management support for MSA1000/MSA1500 18 - HP StorageWorks MSA1500cs | SCO Operating System support of HP StorageWorks Modu - Page 19
hp.com/go/msa1500cs MSA1000 website at http://www.hp.com/go/msa1000 MSA30 website at http://www.hp.com/go/msa30 MSA20 website at http://h18004.www1.hp.com/products/servers/proliantstorage/sharedstorage/sacluster/msa20 consequential damages in connection with the copyright. No part of this document
1
SCO Operating System support of
hp StorageWorks Modular Smart Array
Table of Contents
MSA1500
..........................................................................................................................................
2
MSA1000
..........................................................................................................................................
4
MSA30
..............................................................................................................................................
6
MSA20
..............................................................................................................................................
7
MSA support for SCO Operating Systems – Supported Components
..........................................................
8
Hardware
.......................................................................................................................................
8
Software
.........................................................................................................................................
9
Firmware Upgrade for MSA1000 and MSA1500
.................................................................................
10
MSA Deployment
...............................................................................................................................
11
Connecting MSA to ProLiant servers running SCO operating systems
.......................................................
11
Figure 1. Single Server (Single Path) using the Fibre Channel I/O Module (Direct)
.................................
12
Figure 2. A Typical MSA1000 Configuration using MSA SAN Switch 2/8
...........................................
12
Figure 3. A Typical Configuration with a Server and MSA1000 using MSA Hub 2/3
............................
13
Figure 4. A Typical Single-Path Configuration
....................................................................................
13
Figure 5. A Typical Multi-Path Configuration
.....................................................................................
14
Configuring logical volumes on the MSA
..............................................................................................
15
Installing the HBA Driver
.....................................................................................................................
16
Configuring MSA LUNs in SCO Operating System
................................................................................
17
Limitations
.........................................................................................................................................
18
For more information
..........................................................................................................................
19