HP StorageWorks MSA1510i/MSA20 HP StorageWorks 1510i Modular Smart Array Compa

HP StorageWorks MSA1510i/MSA20 Manual

HP StorageWorks MSA1510i/MSA20 manual content summary:

  • 1
  • 2

Operating Sytems
MS Windows Server
2003 64 bit
MS Windows Server
2003 x64
MS Windows Server
2003 SP1,
MS Windows Server
2003 R2
(32-bit)
MS Windows Server
2000 SP4
(32-bit)
Vmware ESX v3.0.1 (currently supported
with Firmware version 1.30 only)
(host OS supported are MS Windows
Server 2000 SP4, MS Windows Server
2003) (Note: supported only with single
controller)
iSCSI Initiators supported
Microsoft iSCSI
Initiator v2.03
(1)
Microsoft iSCSI
Initiator v2.03
(1)
Microsoft iSCSI
Initiator v2.03
(1)
Microsoft iSCSI
Initiator v2.03
(1)
VMware iSCSI Initiator
Max number of attached nodes
(2)
20
20
20
20
20
HP DSM
for Failover
(3)
supported
Version 5.4.0.X
(5)
supported
Version 5.4.0.X
(5)
supported
Version 5.4.0.X
(5)
supported
Version 5.4.0.X
(5)
N.A.,
only supported with single controller
Storage Management Utility (SMU)
supported
Version 1.32.200
supported
Version 1.32.200
supported
Version 1.32.200
supported
Version 1.32.200
supported
Version 1.32.200
HP Systems Insight Management
supported
Version 5.1
supported
Version 5.1
supported
Version 5.1
supported
Version 5.1
supported
Version 5.1
HP StorageWorks Storage Mirroring®
supported
supported
supported
supported
supported
Single controller only.
Path Failover is not supported.
Supports most HP ProLiant servers
including
ProLiant Intel® servers
DL140 G2, DL320G5, DL360, DL360 G2,
DL360 G3
DL380, DL380 G2, DL380 G3
DL560, DL580, DL580 G2
DL740, DL760, DL760 G2
ML370, ML370 G2, ML370 G3
30
30 G2
ProLiant Intel® servers
DL560
ProLiant INTEL® EM64T servers
DL360 G4, DL360 G4p, DL360 G5
DL380 G4, DL380 G5,
DL580 G3, DL580 G4
ML350 G4, ML350 G4p, ML350 G5
ML370 G4, ML370 G5
ML570 G3, ML570 G4
ProLiant INTEL® EM64T servers
DL360 G4p SCSI, DL360G4p SAS,
DL360 G5 DC SAS
DL380 G4, DL380 G5
DL580 G3 SC, DL580 G3 DC, DL580G4
DC
ML370 G4 SC, ML370 G4 DC,
ML370 G5 DC
ML570 G3 SC, ML570 G3 DC, ML570 G4
DC SAS
Controller: MSA1510i , Firmware version: 1.32 or later
Supported drive shelves
MSA30 (Ultra320): Firmware version: CP20
MSA20 (SATA): Firmware version: 2.02 or later
The MSA1510i is supported only in a Gigabit Ethernet environment.
The MSA1510i supports industry standard gigabit Ethernet components from various manufacturers that conform to IEEE 802.3ab (1000base-T).
For details on standard gigabit Ethernet components (including Gigabit Ethernet switches, Network Interface cards and Ethernet cables) from HP
Supports HP NC370T PCI-X Multifunction Gigabit server adapter (requires NCDE version V8.6)
Supports HP NC380T PCI Express Dual Port Multifunction Gigabit server adapter. (requires NCDE version V8.6)
Supports direct connectivity from server to MSA1510i (without using a switch)
February 2007
Controller Firmware Version 1.32 or higher only
Tested and Supported Configurations
NICs and switches
RELATED SOFTWARE
3. Path Failover is supportied with MPIO Basic Failover for Windows. This provides a single multi-path solution
on a Microsoft
Windows Server 2000 or 2003 host by providing basic path failover.
DSM driver is required from HP for operation and configuration.
4. MSA1510i software installation CD version v1.20
5. Version 5.4.0.X, X=32 for X86 systems, X=64 for X64 and Itanium based systems
SUPPORTED SERVERS
(1) The MSA1510i is supported only with Microsoft iSCSI Initiator
v2.03
(2) Performance can be substantially impacted by number of users and type of application
HP StorageWorks 1510i Modular Smart Array
www.hp.com/go/msa1510i
Compatibility Guide