HP StorageWorks MSA1510i/MSA30 HP StorageWorks 1510i Modular Smart Array firmw
HP StorageWorks MSA1510i/MSA30 Manual
View all HP StorageWorks MSA1510i/MSA30 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA1510i/MSA30 manual content summary:
- HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 1
HP StorageWorks 1510i Modular Smart Array firmware 2.0 release notes Part number: 431339-001 First edition: June 2008 - HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 2
- HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 3
Update recommendation Recommended for all MSA1510i configurations, both single-controller and dual-controller. Supersedes All previous firmware versions. Product models HP StorageWorks 1510i Modular Smart Array (MSA1510i) Devices supported For a list of supported servers, hard drive storage enclosures - HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 4
Device Specific Module (DSM) IMPORTANT: Before installing and using 2.0 active/active firmware, any previous version of the Microsoft iSCSI Initiator and MPIO software and HP DSM must be uninstalled from the server. While this can be done manually, HP recommends using the MSA1510i Support CD version - HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 5
before updating the MSA1510i. Use the following instructions to update MSA20 firmware: 1. Extract the MSA20 firmware image file to a system folder. (The MSA20 firmware filename will be in a format similar to MSA20_v208_b7A31.bin.) HP StorageWorks 1510i Modular Smart Array firmware 2.0 release notes - HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 6
during this process. 3. Manually power cycle all attached MSA20s and wait for them to complete their startup processes. 4. In the SMU, select Storage System > Reset System to restart the MSA1510i. To update MSA1510i firmware, do the following: 1. In dual controller MSA1510i configurations, log off - HP StorageWorks MSA1510i/MSA30 | HP StorageWorks 1510i Modular Smart Array firmw - Page 7
over to the other controller. For more information, see the "Redundant-controller firmware cloning" instructions in the HP StorageWorks 1510i Modular Smart Array maintenance and service guide. Determining installed version To determine the firmware installed on an MSA1510i controller, do one of the
HP StorageWorks 1510i Modular Smart
Array
fi
rmware 2.0 release notes
Part number: 431339–001
First edition: June 2008