HP StorageWorks 1510i Modular Smart Array installation and user guide active/active firmware v2.0 or later Part number: 383070-002 Second edition: May 2008 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 2
contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 3
Contents About this guide 9 Intended audience 9 Prerequisites 9 Related documentation 9 Document conventions and symbols 10 Rack stability 11 HP technical support 11 Customer self repair 11 Product warranties 11 Subscription service 12 HP websites 12 Documentation feedback 12 1 Overview - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 4
status of the devices 55 Viewing the LEDs on the MSA1510i 55 Reading startup messages on the controller display panel 56 Troubleshooting 57 4 Configuration 59 Supported management tools 59 Storage Management Utility (SMU) overview 59 MSA Command Line Interface (MSA-CLI) overview 59 HP Systems - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 5
132 Korean notice (A&B 132 Safety 132 Battery replacement notice 132 Taiwan battery recycling notice 133 Power cords 133 1510i Modular Smart Array installation and user guide 5 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 6
Japanese power cord notice 133 Electrostatic discharge 133 Preventing electrostatic discharge 133 Grounding methods 134 Waste Electrical and Electronic Equipment directive 134 Czechoslovakian notice 134 Danish notice 134 Dutch notice 135 English notice 135 Estonian notice 135 Finnish - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 7
Server information 146 12 Array and unit information 150 13 Target information 151 14 Initiator access information 151 1510i Modular Smart Array installation and user guide 7 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 8
8 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 9
detailed worksheets at the back of this guide. • Read the Compatibility guide to verify support for the operating system and network hardware guide • HP StorageWorks 1510i Modular Smart Array installation and user guide • HP StorageWorks 1510i Modular Smart Array maintenance and service guide - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 10
bodily harm or death. CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. 10 About this - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 11
support For worldwide technical support information, see the HP support website: http://www.hp.com/support and numbers • Technical support registration number (if authorized service provider will determine whether a repair can be about CSR, contact your local service provider. For North America, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 12
Subscription service HP recommends that you register your product at the Subscriber's com/go/storage • http://www.hp.com/service_locator • http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 13
Offload Engines (TOE) processing are supported. • Is a modular 2U rack-mount fault-tolerant RAID levels are supported, including RAID 6 with Advanced storage. The SMU is accessed through a supported Web browser. An easy-to-use Telnet or SSH. By default, Telnet service is disabled. • MSA1510i firmware - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 14
• SCSI and SATA hard drive firmware flashing is supported directly from the SMU using HP Firmware Maintenance CD 7.90 and later. For more information, see the SMU user guide. Front features 1. Blank for an additional controller (controller slot 2) 2. Serial port for a CLI connection 3. MSA1510i - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 15
for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 7. Blanks for additional SCSI I/O modules (buses 1, 2, and 3) 1510i Modular Smart Array installation and user guide 15 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 16
Shipping contents 1. 1510i Modular Smart Array (MSA1510i) 2. 2U universal rack mounting kit 3. Printed documents, 2U rack mounting template, and documentation CD 4. Custom CLI configuration cable 5. Power cords newpage pi 16 Overview - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 17
The following overview is very brief. For additional detail, see the MSA1510i iSCSI concepts and deployment guide, provided on the MSA1510i Support CD v2.0 and MSA1510i support page: http://www.hp.com/support. Targets A target is a grouping of one or more MSA Logical Units (LUNs). The target is the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 18
• Disable unused or insecure services (such as telnet). • Change the logon username and password of the Storage Management Utility. 18 Overview - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 19
additional controller (controller slot 2) 4. MSA1510i controller (controller slot 1) 5. Controller LCD message display panel 6. Controller LCD panel push buttons 1510i Modular Smart Array installation and user guide 19 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 20
Rear view 1. 2-Port Ethernet iSCSI module (for the controller in slot 1) 2. Chassis slot diagram 3. Blank for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 4. Power supply module 2 5. Power supply module 1 6. SCSI I/O module (bus 0) 7. Blank for additional SCSI I/O module ( - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 21
power is off. The system is powered on. The system is in standby mode. The power is off. 1510i Modular Smart Array installation and user guide 21 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 22
of the power supply and some internal circuitry remain active. To remove the power completely, disconnect all power cords from the device. For instructions, see "Powering off the MSA1510i" on page 77. Controller LEDs During normal runtime, the array controller has 18 LEDs that indicate controller - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 23
LEDs Each SCSI hard drive has three LEDs. The following figure and table describe their locations and meanings. 1510i Modular Smart Array installation and user guide 23 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 24
is being accessed in one of the following ways: • The hard drive has been selected for identification in HP-SIM, MSA-CLI, or other supported management utility. • The hard drive is being upgraded. Do not remove the hard drive. Removing a hard drive at this time can cause data loss in - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 25
possible. The drive is offline, a spare, or not configured as part of an array. newpage pi 1510i Modular Smart Array installation and user guide 25 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 26
Slot diagram LEDs Located on the rear of the MSA, the slot diagram provides information about MSA modules. 1. 2-Port Ethernet iSCSI module (for the controller in slot 2) 2. SCSI I/O module (bus 3) 3. SCSI I/O module (bus 2) 4. Fan module 1 5. Fan module 2 6. 2-Port Ethernet iSCSI module (for the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 27
network is established, the status is good, and there is activity on network. There is no network activity. 1510i Modular Smart Array installation and user guide 27 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 28
Fan module LEDs Each fan module has one bi-color LED. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - Amber Meaning The power is on. The - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 29
power is off. There is activity on this SCSI module. There is no activity on this SCSI module. 1510i Modular Smart Array installation and user guide 29 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 30
Power supply module LEDs The power supply uses a single bi-color LED to indicate status. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 31
information • Troubleshooting information Use this iSCSI concepts and deployment guide to develop guide, be sure to pay special attention to any listed "best practices." The iSCSI concepts and deployment guide is provided on the MSA1510i Support CD and MSA1510i support page: http://www.hp.com/support - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 32
guide is available on the Manuals page of the MSA1510i support page: http://www.hp.com/support Includes case studies, products, promotions and services. • Online classes: • Learning center- Modular Smart Array. 5. Follow the on-screen instructions to indicate your delivery preference (HTML, Text, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 33
support page: http://www.hp.com/support. On this page, click See support and troubleshooting information. Also look for Troubleshoot a problem fications • Availability of an HP Services Storage Specialist to answer questions during the in this installation and user guide and on the installation and - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 34
, and best practices. This guide pertains to Fibre Channel and IP networks. Ethernet network switches: http://www.hp.com/rnd Ethernet Network Interface Cards (NICs): http://www.hp.com/servers/networking Support: http://www.hp.com/support Subscriber's Choice notification service: http://www.hp.com/go - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 35
MSA30 SCSI, or other supported models) • Hard drives • Confirm that the hardware and software components you plan to use are supported for use with the troubleshooting purposes. Use the checklist on the poster or in the back of this guide. • Consider reading the HP SAN design guide. This guide - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 36
evenly between the controllers based on I/O loads of the LUNs. • Manual load balancing-Through the SMU or CLI, indicate the preferred path ( environment with adequate physical space, ventilation, and power. • "Providing structural support for the floor" on page 36 • "Providing clearance space and - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 37
fully and provide at least 30 inches (76.2 cm) in the rear of the rack to allow for servicing and airflow. If there are unused spaces in your rack, attach blanking panels across those empty spaces two Uninterruptible Power Supplies (UPS). 1510i Modular Smart Array installation and user guide 37 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 38
Chassis specifications Parameter Value Height 8.78 cm (3.46 in.) Width 48.41 cm (19.06 in.) Depth 61.77 cm (24.32 in.) Weight 24.95 kg (55 lb) Input voltage requirements Rated input voltage 100 to 240 VAC Rated input frequency 47 Hz to 63 Hz Rated input current 6.4A Max, 1A typical - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 39
guide, located on the Manuals page of the MSA1510i support website: http://www.hp.com/support. • Install one or more Ethernet NICs in each server that will access the MSA1510i. For instructions separate paths. • Install all operating-system-specific service packs, patch kits, or other required tools. - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 40
142) For installation instructions, see the service guide, on the MSA1510i Support CD or the MSA1510i support website: http://www.hp.com/support supported for use with the MSA1510i and its storage enclosures, read the MSA1510i compatibility guide, located on the Manuals page of the MSA1510i support - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 41
must assist with aligning the system with the rails, while the other two people support the weight of the system. WARNING! To reduce the risk of personal injury rack, support the weight of the device and keep it level when sliding it into the rack. Racking procedures Use the following instructions to - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 42
1. If desired, use the instructions on the provided rack template to mark the holes on the front and rear rack uprights that will be used by the rails. 2. If the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 43
of the rack until the pins extend through the marked holes and the scissor-pin clicks into place. 1510i Modular Smart Array installation and user guide 43 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 44
6. If necessary, loosen the locking nut on the device retaining bracket and slide the bracket to the farthest position near the rear of the rack. 7. Repeat through to install the other rail. 8. Remove the bezel from the front of the MSA1510i by grasping the bezel by its left and right outside edges, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 45
front of the chassis. Then, with even pressure, push firmly on the bezel until the retaining clips engage. 1510i Modular Smart Array installation and user guide 45 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 46
in the rack, install hard drives into the drive bays. For installation instructions, see the documents shipped with the hard drive or enclosure. Be sure read the MSA1510i compatibility guide, located on the Manuals page of the MSA1510i support website: http://www.hp.com/support. CAUTION: • Follow - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 47
connecting storage enclosures in the same sequence as the preassigned box numbers, as illustrated in the following image: 1510i Modular Smart Array installation and user guide 47 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 48
Item Bus Port Assigned box Assigned box number-SATA number-SCSI A 1 1 0 B 5 1 not used A 2 2 1 B 6 2 not used A 3 3 2 B 7 3 not used A 4 4 3 B 8 4 not used newpage pi 48 Installation - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 49
Supported and unsupported SCSI connections Each SCSI I/O module has two ports. Depending on the type of storage enclosure you plan to connect, one or both of the ports might be supported. Supported Unsupported newpage pi 1510i Modular Smart Array installation and user guide 49 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 50
Connecting SATA storage enclosures In the following illustration, two MSA20 SATA storage enclosures are connected to the MSA1510i using the pre-installed MSA SCSI I/O module. 1 MSA1510i controller shelf 2 MSA20 SATA storage enclosure (SCSI bus 0, Box 1) 3 MSA20 SATA storage enclosure (SCSI bus 0, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 51
. 1 Server 2 iSCSI Ethernet network switch 3 MSA1510i controller shelf newpage pi 4 Storage enclosure (MSA20 SATA) 5 Ethernet cables 6 SCSI cable 1510i Modular Smart Array installation and user guide 51 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 52
Connecting Ethernet cables in a multipath configuration In the following illustration, additional items and cabling connections are needed in a multipath configuration. 1 Additional iSCSI Ethernet network switch 2 Additional MSA 2-Port Ethernet iSCSI module 3 Additional Ethernet cables for the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 53
the device. • Unplug the power cord from the power supply to remove power from the equipment. newpage pi 1510i Modular Smart Array installation and user guide 53 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 54
Powering on the MSA 1. Verify that the following devices are powered on and in a ready state: • Uninterruptible Power Supplies (UPS) • Network switches 2. Power on all attached hard drive storage enclosures. IMPORTANT: Proceed to the next step only after confirming that the external storage - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 55
maintenance and service guide.http://h18006.www1 instructions, see "Changing the management port IP address through the MSA1510i controller display panel" on page 102. Included sections: • Viewing the LEDs on the MSA1510i • Reading startup messages on the controller display panel • Troubleshooting - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 56
MSA1510i component LED Power supply module status LED Fan control module status LED 2-Port Ethernet iSCSI module status LED SCSI I/O module status LED Condition Solid green = power is on. Solid green = power is on. Solid green = power is on, the module is operational, and communication between the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 57
on page 102. Troubleshooting If the LED patterns in are not displayed, or the MSA Startup Complete message is not displayed: • Check the cable connections to the MSA1510i. • Check the availability of your power source. • Review the setup instructions in previous sections of this guide. • Remove and - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 58
58 Installation - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 59
iSCSI initiator • Configuring the VMware iSCSI software initiator Supported management tools The following is a partial list of the tools that are supported for use with the MSA: • Storage Management Utility ( Connection (SSH) or Telnet. 1510i Modular Smart Array installation and user guide 59 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 60
Sample tasks include: configuring iSCSI elements, setting up the management interface, configuring the logical units (LUNs), limiting access to the storage, viewing controller and storage setup, viewing status information, and running diagnostic reports. HP Systems Insight Manager (HP-SIM) overview HP - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 61
the MSA1510i installation and user guide • Ensure that initiators and targets portal group, configure the mapping to manually load balance ownership of the LUNs between the the MSA1510i Support CD from the MSA1510i Support page: http://www.hp.com/go/support. Upgrade instructions are provided on - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 62
) load balancing (default)-MSA firmware automatically reassigns LUN ownership evenly between the controllers based on I/O loads of the LUNs. (Recommended) • Manual (also called explicit) load balancing-Through the SMU or the CLI, indicate the preferred path (controller ownership) for each LUN. Con - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 63
path to the target. a. Select the Discovery tab. b. In the Target Portals section of the window, click Add. 1510i Modular Smart Array installation and user guide 63 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 64
. However, if the target has not granted access to the initiator, when a logon is attempted, access will be denied. With the implementation of iSNS support, iSNS discovery domain may be put in place to address this issue. The following illustration shows the Discovery tab after adding the portals to - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 65
to select more than once per IP address and target. • Enable multi-path (Multipathing environments only) c. Click Advanced. 1510i Modular Smart Array installation and user guide 65 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 66
d. Expand the drop-down boxes and enter the following settings: • Local adapter: Microsoft iSCSI Initiator • Source IP: Enter the IP address of the NIC that has access to the target portal that you want to connect to (and will enter in the next step). • Target Portal: Select the destination target - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 67
. 5. Verify the connection status to the target. a. On the Targets tab, select the target and then click Details. 1510i Modular Smart Array installation and user guide 67 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 68
NOTE: In multipathing environments only, two sessions should be established: • one for the target portal associated with MSA controller A • one for the target portal associated with MSA controller B b. Select one of the listed sessions and then click Connections. c. View the information in the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 69
port associated with the active MSA controller path.) Troubleshooting Problem Possible cause / solution Microsoft iSCSI initiator cannot MSA controller maximum session count may have been exceeded. The controller supports a maximum of 32 sessions per controller. Log out of targets user guide 69 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 70
VMware iSCSI software initiator NOTE: Only iSCSI software initiators are supported by MSA1510i. This section describes how to configure targets, they appear on the Static Discovery list. To this list, you can manually add any additional targets, or remove targets you don't need. The static discovery - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 71
ESX Server supports the Challenge Handshake Authentication Protocol (CHAP) that your iSCSI initiators can use for authentication purposes. After your initiator the iSCSI Initiator Properties dialog box. 2. Click the Dynamic Discovery tab. 1510i Modular Smart Array installation and user guide 71 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 72
3. To add a new iSCSI target that your ESX Server host can use for a SendTargets session, click Add. The Add Send Targets Server dialog box displays. 4. Enter the Send Targets server IP address, and click OK. 5. To change or delete a Send Targets server, select the server and click Edit or Remove. - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 73
secret to authenticate the initiator. Any established sessions are not affected. 7. Click OK to save changes. 8. Perform a rescan. 1510i Modular Smart Array installation and user guide 73 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 74
NOTE: If you disable CHAP, all sessions that require CHAP authentication will end immediately. Performing a Rescan If a new LUN becomes accessible through the adapter, then ESX Server registers this new virtual device for use by virtual machines. If an existing LUN is no longer used and appears to - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 75
Troubleshooting Problem Possible cause / solution iSCSI initiator initiator. • The MSA controller maximum session count may have been exceeded. The controller supports a maximum of 32 sessions per controller. Log out of targets on any non- Modular Smart Array installation and user guide 75 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 76
76 Configuration - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 77
backup is available. 3. Power down all servers with access to the MSA, or if your operating system fully supports it, quiesce all I/O, disconnect all connections, and dismount all LUNs. 4. On the MSA, press and hold power cords from the MSA. 1510i Modular Smart Array installation and user guide 77 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 78
Powering on the MSA 1. Verify that the following devices are powered on and in a ready state: • Uninterruptible Power Supplies (UPS) • Network switches 2. Power on all attached hard drive storage enclosures. IMPORTANT: Proceed to the next step only after confirming that the external storage - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 79
other network devices, including the MSA. Updates may include additional features and functions, performance enhancements, support for newly released hardware, or fixes to known issues. NOTE: In a dual-controller MSA, • HP and MSA websites 1510i Modular Smart Array installation and user guide 79 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 80
• MSA release notes and readme files 3. Identify items that need updating. (Table 6) Table 6 Version information worksheet: firmware, driver, and software components Component Currently- Latest-available installed version version Update ? Operating system Y/N Operating system patch kit Y/N - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 81
, power cycle the MSA and all of its attached hard drive storage enclosures to activate the new firmware. 1510i Modular Smart Array installation and user guide 81 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 82
problems during the firmware update process, stop and contact HP technical support. See for support contact information. Updating MSA firmware using the SMU NOTE: For complete information about accessing and using the SMU, see the HP Storage Management Utility user guide service -screen instructions to - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 83
. g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA controller LCD panel. 1510i Modular Smart Array installation and user guide 83 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 84
using the MSA-CLI This out-of-band, MSA-based updating method is supported for use in most environments, with a few limitations. IMPORTANT: Before using rmware is with the SMU. See the HP Storage Management Utility user guide for more information. NOTE: For more information about accessing and using - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 85
a. Navigate to the MSA1510i support page: http://www.hp.com/go/support. b. Click the title description changes, important notes, service considerations, and installation update, click Download and follow the on-screen instructions to save the download bundle to a temporary directory guide 85 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 86
CLI> download firmware where: offline -performs an update, but does not automatically restart the MSA; the MSA must be restarted manually. Can be used in single-controller and dual-controller configurations. online-performs an update with an automatic restart upon completion. Can be - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 87
. g. Wait (up to eight minutes) for the STARTUP COMPLETE message to display on the MSA controller LCD panel. 1510i Modular Smart Array installation and user guide 87 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 88
13. View the messages displayed on the array controller LCD panel during startup to confirm that the firmware was installed successfully and that the array controller restarts successfully. NOTE: In dual-controller configurations, firmware on the two controllers is compared each time the MSA chassis is - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 89
ISO image for the latest ProLiant Firmware Maintenance CD from the following website: http://www.hp.com/support/proliantstorage. Then, burn the image onto a bootable CD using a standard CD-ROM burning utility. browser and access the SMU. 1510i Modular Smart Array installation and user guide 89 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 90
5. Select Update > Storage System > Flash Firmware. 6. Under the Upload Inventory Firmware XML File banner, click Browse, navigate to the location of the previously-obtained XML firmware file, select an updating option, and then click OK. XML firmware filenames may be similar to the following: - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 91
select the option to receive e-mail notifications, advisories, and support alerts about MSA system hardware, firmware, drivers, and software about your MSA is not requested when subscribing to this service. 2. Establish a serial connection to the affected controller Array installation and user guide 91 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 92
3. Using the emulator transfer (or send file) command, send the firmware to the controller. The following instructions and examples use HyperTerminal. For more information, see user documentation for your emulator program. a. On the menu bar at the top of the HyperTerminal window, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 93
preserve the integrity of the local drive, but does require manual intervention to recover or re-enable the LUN. Although controller hard drives. For more information on troubleshooting hard drive problems, see the HP ProLiant servers troubleshooting guide. Effects of hard drive failure When - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 94
, the LUN is taken offline and subsequent I/O requests are rejected. This is designed to protect the integrity of the LUN, but does require manual intervention to recover or re-enable the LUN. You are likely to lose data, although it can sometimes be recovered. Common causes of compromised fault - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 95
ADG configuration. Time required for a rebuild The time required for a rebuild varies considerably, depending on several factors: 1510i Modular Smart Array installation and user guide 95 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 96
• The priority that the rebuild is given over normal I/O operations (you can change the priority setting through the Array Configuration Utility (ACU), Storage Management Utility (SMU), or MSA Command Line Interface (MSA-CLI). • The amount of I/O activity during the rebuild operation • The rotational - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 97
HP ProLiant servers troubleshooting guide, available on the Management CD • MSA1510i installation and user guide Removing the hard drive warnings, cautions, and preparation procedures as detailed in the MSA1510i Maintenance and service guide. 2. Be sure that the Online and Drive Access LEDs are both - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 98
4. Pull the hard drive out of the storage enclosure bay (3). Installing the hard drive NOTE: Illustrations in this section demonstrate installing a hard drive in an MSA20 storage enclosure. The procedure for installing a hard drive in an MSA30 or other storage enclosure is similar. 1. Press the hard - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 99
with data from the other hard drives. While reconstruction is in progress, the online LEDs flash. newpage pi 1510i Modular Smart Array installation and user guide 99 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 100
up an array NOTE: For the most up-to-date information on supported storage enclosures, see the MSA website. Adding new hard drive storage such as the SMU, ACU, or MSA-CLI to configure the new storage. For instructions, see the user documents for the utility. 10. In iSCSI environments, be sure to - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 101
of the array. When the appropriate conditions are met, perform the following procedure to move the hard drives: 1510i Modular Smart Array installation and user guide 101 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 102
1. Power Off the MSA storage system as detailed in Powering off the MSA1510i. 2. Move the hard drives. 3. Power on the MSA storage system as detailed in Powering on the MSA. 4. The following message should be displayed on the LCD front panel of the controller 86 DRIVE POSITION CHANGE DETECTED. - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 103
. 7. Verify that the server can locate the MSA1510i by opening a command prompt window and using the ping command. 1510i Modular Smart Array installation and user guide 103 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 104
104 Operation and management - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 105
at the same time to delete the currently displayed message. The display module consists of the following components: 1510i Modular Smart Array installation and user guide 105 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 106
User input messages For a complete list of messages and their meanings, see "LCD message descriptions" on page 107. Error messages Error messages indicate that a problem has occurred and may require user action to correct it. The array controller Fault LED to the left of the LCD display panel lights - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 107
. 01 MSA STARTUP COMPLETE Informational The array controller has completed its power on sequence and is now operational. 1510i Modular Smart Array installation and user guide 107 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 108
-controller configurations and in dual-controller configurations where both controllers are locked-up, restart the MSA chassis. If the issue persists, contact HP support. An issue has been found with all of the configured volumes that may result in data loss. The exact nature of the issue is - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 109
SUPPORTED Error 09 PILOT 2 CONTRLR NOT SUPPORTED supported for use with the version of installed firmware. This controller is not supported. Contact HP support supported for use with the version of installed firmware. This controller is not supported. Contact HP support contact HP support. A support - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 110
any SE devices and replace them with LVD devices. The array controller has been inserted in an MSA chassis in which it is not supported. Contact HP support. The MSA is not properly identifying an external storage enclosure. Do the following: 1. Remove power from the MSA and all attached storage - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 111
loss of functionality (such as lost display messages). If the issue persists, contact HP support. The MSA has non-volatile memory on it that contains required information, which is chassis. Should the issue persist, contact HP support. 1510i Modular Smart Array installation and user guide 111 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 112
cloning, which attempts to make them both the same firmware level, has failed. Manually update the firmware on the older array controller. If volume expansion is in progress then redundancy is not supported. Volume expansion is initiated and tracked using the Array Configuration Utility (ACU) or - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 113
the issue persist, contact HP support. While either attempting to the issue persist, contact HP support. While either attempting to Should the issue persist, contact HP support. While either attempting to enter redundant the issue persist, contact HP support. While operating in redundant mode, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 114
safely be removed. Remove the other array controller for the planned service. When complete, reinsert the array controller, ensuring that it it is fully seated in the chassis. If the issue persists, contact HP support. The array controller has two cache modules attached but they are of different - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 115
controller, ensuring it is fully seated in the chassis. Should the issue persist, contact HP support. The cache memory hardware has temporarily been disabled, typically because the battery is not charged or Line Interface (MSA-CLI). 1510i Modular Smart Array installation and user guide 115 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 116
Message Type 71 SYSTEM HALTED FOR CACHE ERROR Error 72 CACHE ERROR IGNORE? =YES User input Description Action This message is displayed upon a no response to message 72 CACHE ERROR IGNORE? =YES . If = 1.1 or 1.2: There is currently only one cache module in the array - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 117
the array controller, ensuring it is fully seated in the chassis. Should the issue persist, contact HP support. A SCSI hard drive that was previously missing or failed has now been replaced with a working SCSI to their original positions. 1510i Modular Smart Array installation and user guide 117 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 118
Message 88 NON-HP DRIVE BOX #, BAY Type Informational 89 INVALID CONFIG BOX #, BAY Error 100 VOLUME # STATE OK Informational 101 VOLUME # STATE FAILED Error 102 VOLUME # STATE INTERIM RECOVERY Informational 103 VOLUME # STATE REBUILDING Informational 104 VOLUME - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 119
02 ENABLE VOLUME ? ''=YES. The specified number of configured volumes were detected at power up. 1510i Modular Smart Array installation and user guide 119 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 120
MSA. Configured volumes from another array controller were migrated to this array controller. The configuration information has been updated. The array controller supports a maximum of 32 configured volumes. More than 32 volumes were detected at power up. This typically occurs when migrating a set of - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 121
that it is fully seated in the chassis. If the issue persists, contact HP support. 205 ARRAY CONTROLLER RESTARTING Informational 300 RECOVERY ROM AUTOFLASH STARTED Informational The array controller has the backup recovery ROM. 1510i Modular Smart Array installation and user guide 121 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 122
autoflash process is attempted again. Should the issue persist, contact HP support. Indicates that the two array controllers in the MSA do not have ROM cloning process is attempted again. If the issue persists, contact HP support. The array controller in the MSA has started the firmware flash process - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 123
unable to update the firmware on the iSCSI daughter board. Retry the operation. Contact HP support if the problem persists. Indicates that the array controller has detected out-of-date firmware on a fan . This could take several minutes. 1510i Modular Smart Array installation and user guide 123 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 124
a fan module. Indicates that the array controller was unable to update the firmware on a fan module. Retry the operation. Contact HP support if the problem persists. The array controller was unable to proceed with a firmware flashing or cloning operation because the cache batteries are low and there - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 125
storage enclosure. Then reapply power to the storage box and then the MSA. If the issue persists, contact HP support. The version of firmware running on the EMU. This is only displayed for the internal EMU of the MSA to the back of the MSA. 1510i Modular Smart Array installation and user guide 125 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 126
to the MSA. For more information, see the MSA installation guide. The array controller's PCI subsystem is being initialized as part of persist, contact HP support. An error occurred while programming iSCSI configuration to the iSCSI hardware. Contact HP support if the problem persists. 126 MSA - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 127
module has failed. Verify that the module is inserted properly into the bay. If the problem persists, replace the module. The Target-Based Management subsystem is being initialized as part of is disabled. Contact HP support. 1510i Modular Smart Array installation and user guide 127 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 128
from the network. The detected MSA processor revision. The array controller has detected a 10 Mb/s link on the indicated Ethernet port. The MSA1510i does not support 10 Mb/s, so communication with this port is not possible. Connect the port to a switch capable of 100 Mb/s or 1000 Mb/s. 128 MSA - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 129
both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class (A or B) the equipment cause undesired operation. 1510i Modular Smart Array installation and user guide 129 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 130
than those specified herein, or in the laser product's installation guide, may result in hazardous radiation exposure. To reduce the risk of • Do not try to open the module enclosure. There are no user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 131
• EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics • EN61000-3-3 (IEC61000-3-3) - Power Line Flicker • EN 60950 (IEC 60950) - Product Safety BSMI notice 1510i Modular Smart Array installation and user guide 131 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 132
Japanese notice Korean notice (A&B) Class A equipment Class B equipment Safety Battery replacement notice WARNING! The computer contains an internal lithium manganese dioxide, a vanadium pentoxide, or an alkaline battery pack. A risk of fire and burns exists if the battery pack is not properly - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 133
3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items placed in static-safe containers. 1510i Modular Smart Array installation and user guide 133 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 134
at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 135
waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Estonian notice Seadmete jäätmete kõrvaldamine tai liikkeeseen, josta tuote on ostettu. 1510i Modular Smart Array installation and user guide 135 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 136
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 137
łych ze sprzętu elektrycznego i elektronicznego. Osobna zbiórka oraz recykling zużytego sprzętu pomogą w ochronie zasobów 1510i Modular Smart Array installation and user guide 137 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 138
naturalnych i zapewnią ponowne wprowadzenie go do obiegu w sposób chroniący zdrowie człowieka i środowisko. Aby uzyskać więcej informacji o tym, gdzie można przekazać zużyty sprzęt do recyklingu, należy się skontaktować z urzędem miasta, zakładem gospodarki odpadami lub sklepem, w którym zakupiono - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 139
ållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 1510i Modular Smart Array installation and user guide 139 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 140
140 Regulatory compliance and safety - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 141
, and some of the information may be helpful for future configuration changes and troubleshooting purposes. The following worksheets are included in this section: • Basic MSA1510i information Target information • Initiator access information 1510i Modular Smart Array installation and user guide 141 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 142
Table 8 Basic MSA1510i information Component Configuration type (check one) MSA1510i chassis serial number Controller firmware version, installed Controller firmware version, Web Installation CD version shipped Installation CD version on the Web IP address for management port Subnet mask Standard - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 143
port and three TCP ports per IP address. Your configuration may use fewer or more IP segments. 1510i Modular Smart Array installation and user guide 143 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 144
MSA1510i 2-Port Ethernet iSCSI module IP address information (continued) Component Settings Redundant module, for the controller in slot 2 Location: Rear-right of the MSA1510i Physical port 0 (top port) Logical port SB0 IP address / VLAN ID TCP port TCP port IP address / VLAN ID TCP port - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 145
network switches with VLANs per network switch. Your configuration may have fewer or more switches and VLANs. 1510i Modular Smart Array installation and user guide 145 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 146
Table 11 Server information Component Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID Settings 100/1000BaseT NIC model NIC slot number/port number NIC IP - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 147
Server information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID : Clustering software and version Cluster cabling 1510i Modular Smart Array installation and user guide 147 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 148
Server information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID Settings 100/1000BaseT NIC model NIC slot number/port number NIC IP - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 149
Server information (continued) Component An additional server: Make and model Operating system, version Service pack and patch kit Server name iSCSI qualified name (iQN) VLAN ID : Clustering software and version Cluster cabling 1510i Modular Smart Array installation and user guide 149 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 150
Table 12 Array and unit information Array Unit # RAID level Disk members Unit nl capacity Drive type (SCSI/SATA) Spare 150 MSA1510i worksheets - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 151
Table 13 Target information Target Units LUNs IP address/subnet/port MSA portal/portal group/logical port Table 14 Initiator access information Server name iQN name Initiator alias Assigned target VLAN ID 1510i Modular Smart Array installation and user guide 151 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 152
152 MSA1510i worksheets - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 153
obtaining, 84 Command Line Interface, overview, 59 components, 19 supported hard drives, 46 compromised fault tolerance, 94 failed LUNs, 94 device found, 110 bad scsi target, 110 beacon on, 121 begin redundancy support, 111 cache batteries low recharging, 115 cache data lost battery dead, 114 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 154
upgrade restarting system, 109 PCI bridge ASIC self-test failure, 126 PCI subsystem hardware failure, 126 persistent mem disabled, 126 pilot 2 contrlr not supported, 109 read failure, 110 recovery ROM autoflash done, 122 recovery ROM autoflash failed, 122 recovery ROM autoflash started, 121 redundancy - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 155
on box #, 124 firmware flash failed, 109 firmware flash failed on box #, 123 fw version is not supported, 110 hard drive failure box, 117 I2C read failure, 110 I2C write failure, 111 invalid config box 3, bay 126 volume expansion failure, 119 1510i Modular Smart Array installation and user guide 155 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 156
, 93 recovering, 93 hard drive firmware updating, 89 hard drives approved models, 46 caution, 41 installing, 46 migrating, 101 from one controller to another, 101 supported, 46 help obtaining, 11, 33 High Availability website, 34 HP series number, 130 Subscriber's Choice for Business, 32 technical - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 157
initializing PCI subsystem, 126 initializing redundancy support, 111 initializing SCSI subsystem, 110 initializing practices, 17 overview of, 17 iSCSI concepts concepts guide, 31 iSCSI concepts and deployment guide, 31 iSCSI terminology concepts guide, 31 L laser compliance, 130 latches, hard - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 158
81 MSA controller firmware overview, 79 updating, 79 prerequisites, 81 updating using the SMU, 82 MSA1510i overview, 13 MSA1510i compatibility guide website, 46 MSA1510i controller LEDs, 22 MSA1510i controller display panel changing management port IP address, 102 MSA1510i information iSCSI concepts - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 159
151 targets overview of, 17 tasks initial configuration, 61 technical support HP, 11 service locator website, 12 text symbols, 10 troubleshooting, at startup, 57 U updates firmware, prerequisites, 81 website Electronic Equipment directive, 134 1510i Modular Smart Array installation and user guide 159 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array installatio - Page 160
websites clustering, 34 customer self repair, 11 enclosures, 34 HP , 12 HP documentation, 9 HP Subscriber's Choice for Business, 12 infrastructure, 34 Insight Manager, 34 MSA1510i, 9, 34 multipathing, 34 OS information, 10 related information, 9 servers, 34 Subscriber's Choice, 34 switches, 34