HP StorageWorks MSA1510i HP StorageWorks 1510i Modular Smart Array maintenance
HP StorageWorks MSA1510i Manual
View all HP StorageWorks MSA1510i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA1510i manual content summary:
- HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 1
HP StorageWorks 1510i Modular Smart Array maintenance and service guide Part number: 383072-002 Second edition: May 2008 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 3
Contents About this guide 7 Intended audience 7 Prerequisites 7 Related documentation 7 Document conventions and symbols 8 Rack stability 9 HP technical support 9 Customer self repair 9 Subscription service 9 HP websites 9 Documentation feedback 10 1 Illustrated parts list 11 2 Specifi - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 4
Returning the defective component 32 Recommended tools 33 Warnings and precautions 33 Electrostatic discharge information 33 Grounding methods 33 Equipment symbols 34 Weight warning 35 Rack warnings and precautions 35 Device warnings and precautions 36 Determining whether a component is hot - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 5
Installing the power supply module 60 Verifying proper operation 60 Replacing the MSA1510i chassis 61 Before you begin 61 Verifying component failure 61 Removing the chassis components 62 76 Hungarian notice 77 Italian notice 77 1510i Modular Smart Array maintenance and service guide 5 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 6
Latvian notice 77 Lithuanian notice 78 Polish notice 78 Portuguese notice 78 Slovakian notice 78 Slovenian notice 79 Spanish notice 79 Swedish notice 79 Index 81 6 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 7
user guide • HP StorageWorks 1510i Modular Smart Array maintenance and service guide • HP StorageWorks 1510i Modular Smart Array Command Line Interface user guide • HP StorageWorks Storage Management Utility user guide These documents are on the MSA1510i Support CD, available on the MSA1510i support - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 8
MSA1510i-specific documents, the following guide, available on the SAN Infrastructure website: http://www.hp.com/go/san, includes detailed, helpful information about Fibre Channel and iSCSI networks: • HP SAN Design reference guide Name Service (iSNS) • RFC number 2608: Service Location Protocol - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 9
(CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 10
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 About this guide - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 11
breakdown and spare parts list for the HP StorageWorks 1510i Modular Smart Array (MSA1510i). Item Description Service replacement module part number Standard shipping configuration Mandatory Optional Mandatory Optional Optional Mandatory 1510i Modular Smart Array maintenance and service guide 11 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 12
MSA1510i controller 7 with 256 MB cache 417787-001 module and batteries AD539-04001 Optional 8 MSA controller blanking panel 229208-001 n/a Mandatory Shipped items not illustrated: AC power cords Contact HP Support Contact your HP Authorized Reseller Mandatory Custom serial cable for - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 13
2 Specifications This section provides operating and performance specifications for the MSA1510i. Included in this section: • Chassis specifications • 2-Port Ethernet iSCSI module specifications • Fan part numbers, see Illustrated parts list. 1510i Modular Smart Array maintenance and service guide 13 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 14
Chassis specifications Parameter Value Height 8.79 cm (3.46 in) Width 48.41 cm (19.06 in) Depth 61.77 cm (24.32 in) Weight 24.95 kg (55 lb) Input voltage requirements Rated input voltage 100 to 240 VAC Rated input frequency 50 Hz to 60 Hz Rated input current 6.4A Max, 1A typical - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 15
fications Parameter Height Width Depth Weight Value 7.7 cm (3.0 in) 6.4 cm (2.5 in) 32.0 cm (12.6 in) 1.80 kg (3.96 lb) 1510i Modular Smart Array maintenance and service guide 15 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 16
16 Specifications - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 17
component LEDs Front view 1. Chassis LEDs 2. Chassis Power On/Standby button 3. Blank for an additional controller (controller slot 2) 4. MSA1510i controller (controller slot 1) 5. Controller LCD message display panel 6. Controller LCD panel push buttons 1510i Modular Smart Array maintenance and - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 18
Rear view 1. 2-Port Ethernet iSCSI module (for the controller in slot 1) 2. Chassis slot diagram 3. Blank for additional 2-Port Ethernet iSCSI module (for the controller in slot 2) 4. Power supply module 2 5. Power supply module 1 6. SCSI I/O module (bus 0) 7. Blank for additional SCSI I/O module ( - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 19
panel, and system event logs (such as those provided by HP Systems Insight Manager). The following sections define the LEDs. • Chassis LEDs • MSA1510i controller LEDs • Hard drive LEDs • Slot diagram LEDs • standby mode. The power is off. 1510i Modular Smart Array maintenance and service guide 19 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 20
supply and some internal circuitry remain active. To remove the power completely, disconnect all power cords from the device. For instructions, see "Powering off the MSA1510i" on page 38. Controller LEDs During normal runtime, the array controller has 18 LEDs that indicate controller activity or - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 21
drive LEDs Each SCSI hard drive has three LEDs. The following figure and table describe their locations and meanings. 1510i Modular Smart Array maintenance and service guide 21 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 22
loss. The hard drive is being accessed in one of the following ways: • The hard drive has been selected for identification in HP-SIM, MSA-CLI, or other supported management utility. • The hard drive is being upgraded. Do not remove the hard drive. Removing a hard drive at this time can cause - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 23
(1 possible. Hz) Off Off The drive is offline, a spare, or not configured as part of an array. 1510i Modular Smart Array maintenance and service guide 23 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 24
Slot diagram LEDs Located on the rear of the MSA, the slot diagram provides information about MSA modules. 1. 2-Port Ethernet iSCSI module (for the controller in slot 2) 2. SCSI I/O module (bus 3) 3. SCSI I/O module (bus 2) 4. Fan module 1 5. Fan module 2 6. 2-Port Ethernet iSCSI module (for the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 25
the network is established, the status is good, and there is activity on network. There is no network activity. 1510i Modular Smart Array maintenance and service guide 25 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 26
Fan module LEDs Each fan module has one bi-color LED. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - Amber Meaning The power is on. The - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 27
. The power is off. There is activity on this SCSI module. There is no activity on this SCSI module. 1510i Modular Smart Array maintenance and service guide 27 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 28
Power supply module LEDs The power supply uses a single bi-color LED to indicate status. This LED can be illuminated with either a green or amber color. The following figure and table describes their locations and meanings. Item Name 1 Status 2 Fault Condition Solid Off Blinking Color Green - - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 29
that allows system administrators to accomplish normal administrative tasks from any remote location, using a Web browser. HP-SIM provides device management capabilities that consolidate and integrate management data from HP and 1510i Modular Smart Array maintenance and service guide 29 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 30
and write requests • Number of sectors read or written For more information, see the Management CD in the HP ProLiant Essentials Foundation Pack or the HP-SIM website: http://www.hp.com/go/hpsim. Packet InterNet Groper (PING) overview Use the PING utility to check network connections. PING bounces - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 31
SCSI I/O module • Replacing a power supply assembly • Replacing the MSA1510i chassis IMPORTANT: To reduce the risk of personal injury or damage component failure - Before replacing a component, confer with HP technical support to verify that the hardware component has failed and and service guide 31 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 32
defective parts replacement. If, during the diagnosis period, HP (or HP service providers or partners) identifies that the repair can be accomplished is required, you can call the HP Technical Support Center, and a technician will help you over the telephone. HP specifies in the materials shipped with - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 33
. With a CSR, HP will pay all shipping Circuit Board (PCB) side down. • Use conductive field service tools. Grounding methods There are several methods for grounding. Use floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 34
static electricity or assistance with product installation, contact your HP Authorized Reseller. Equipment symbols The following symbols may be the presence of electrical shock hazards. Enclosed area contains no operator serviceable parts. To reduce the risk of injury from electrical shock hazards, - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 35
health and safety requirements and guidelines for manual material handling. • Get help to lift in aligning the rails while the other two support the device. Rack warnings and precautions Ensure that and warnings included in the installation instructions. WARNING! To reduce the risk service guide 35 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 36
in the procedures in the product documentation. All troubleshooting and repair procedures are detailed to allow only by individuals who are qualified in servicing computer equipment, knowledgeable about the procedures safety requirements and guidelines for manually handling material. CAUTION: Protect - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 37
been taken to prevent loss of data. Determining whether a component is hot-pluggable Before removing any serviceable part, determine whether the part is hot-pluggable or non-hot-pluggable. • If the component is cooling within the device. 1510i Modular Smart Array maintenance and service guide 37 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 38
maintenance window. 2. Ensure that a known good backup is available. 3. Power down all servers with access to the MSA, or if your operating system fully supports it, quiesce all I/O and dismount all LUNs. 4. On the MSA, press and hold down the Power on/Standby button on the front of the chassis - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 39
system, and log on as a user with administrative control. 7. Verify that each device in the network is operating properly. 1510i Modular Smart Array maintenance and service guide 39 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 40
Removing or installing a 2-Port Ethernet iSCSI blank Before you begin CAUTION: • Before removing a component or blank from an operational device, make sure that you have the replacement part or blank available. Removing a component or blank impacts the airflow pattern and cooling ability of the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 41
(2). Installing a hard drive blank Slide the blank into the enclosure chassis bay until it clicks into place. newpage pi 1510i Modular Smart Array maintenance and service guide 41 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 42
in data loss. Replace marginal hard drives as soon as possible. • Open HP-SIM and inspect the Error Counter window for each physical drive in the same confirm that no other hard drives have errors. For details, see the HP-SIM documentation on the Management CD. • Do not remove a degraded hard drive - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 43
hard drives are inside. (However, this LED also illuminates when other problems occur, such as when a fan fails, a redundant power supply page 21 • The HP ProLiant Servers Troubleshooting Guide, available on the Management CD • MSA1510i installation and user guide Removing the hard service guide 43 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 44
3. Press the ejector button (1) and pull the release lever to the full open position (2). IMPORTANT: Wait approximately 10 seconds for the internal disk to stop spinning before pulling the hard drive out of the enclosure. Handling a hard drive while the internal media is spinning can damage the - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 45
automatically with data from the other hard drives. While reconstruction is in progress, the Online LEDs flash. newpage pi 1510i Modular Smart Array maintenance and service guide 45 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 46
• Verifying the replacement Perform only the steps required for your service event. For example, re-seating an array controller includes Removing . Use proper anti-static protection. CAUTION: • When replacing a controller, HP recommends that the old cache module be moved to the new controller. In - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 47
gurations, schedule an maintenance window for the service. For instructions on shutting down the MSA, see Powering off the MSA1510i. 4. In operational dual-controller confi power from the system to perform the service. If your system is equipped with two controllers: 1510i Modular Smart Array - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 48
disk writes trapped in the controller cache. 1. Remove the controller from the chassis as instructed in Removing the controller. 2. Locate the controller cover clips on the rear, lower of in fire or water. • Replace only with the HP spare designated for this product. 48 Customer replaceable components - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 49
HP, your authorized HP instructed in Removing the controller cache module. 3. Push down on the battery retaining clip, located near the lower corner of the module. 4. Swing the battery pack away from the cache module to about a 30-degree angle. 1510i Modular Smart Array maintenance and service guide - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 50
second battery pack on this cache module. Installing the controller cache battery pack 1. Remove the array controller as instructed in Removing the controller. 2. Remove the controller cache module as instructed in Removing the controller cache module. 3. Remove the controller cache battery pack as - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 51
second battery pack on the module. 8. Install the serviced cache module in the controller as instructed in Installing the controller cache module. NOTE: The cache Close the controller cover. 3. Insert the serviced controller into the chassis as instructed in Installing the controller. newpage pi - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 52
to clone the firmware from the controller with the latest version onto the other controller. For more information, see the MSA1510i installation and user guide. Verifying proper operation After replacing the array controller, controller cache module, or cache module battery pack, verify that: • The - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 53
, cautions, and preparation procedures as detailed in Warnings and precautions. 2. Disconnect the cable from the 2-Port Ethernet iSCSI module. 1510i Modular Smart Array maintenance and service guide 53 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 54
3. Lift the port-colored 2-Port Ethernet iSCSI module latch (1) and pull the module out of the enclosure (2). Installing the 2-Port Ethernet iSCSI I/O module 1. Slide the replacement 2-Port Ethernet iSCSI module into the MSA chassis bay until the module clicks into place. 2. Reconnect the cables. - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 55
the fan module Slide the replacement fan module into the MSA chassis bay until the module clicks into place. 1510i Modular Smart Array maintenance and service guide 55 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 56
15210 Verifying proper operation After replacing the fan module, verify that: • The fan starts operating immediately. • The fan Status LED is On. • No new error messages are displayed on the array controller LCD panel. newpage pi 56 Customer replaceable components - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 57
all cables. This ensures their reconnection in the correct configuration. 2. Disconnect all SCSI cables from the SCSI I/O module. 1510i Modular Smart Array maintenance and service guide 57 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 58
3. Lift the port-colored SCSI I/O module latch (1) and pull the SCSI I/O module out of the chassis (2). Installing the SCSI I/O module 1. Slide the replacement SCSI I/O module into the MSA chassis bay until the module clicks into place. 2. Reconnect all SCSI cables. NOTE: Ensure that all of the SCSI - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 59
module latch (1) to the left, grasp the module handle and pull the defective power supply out of the chassis (2). 1510i Modular Smart Array maintenance and service guide 59 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 60
Installing the power supply module 1. Slide the replacement power supply module into the MSA chassis bay until the module clicks into place. 2. Connect the AC power cord to the power supply. Verifying proper operation After replacing the power supply, verify that: • The power supply Status LED is - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 61
that there is a known, good backup of the system. Backup all volumes and, for the MSA1510i, record the iSCSI and Management settings. TIP: Before disconnecting any cables and components, label them so that the chassis Status LED is off. 1510i Modular Smart Array maintenance and service guide 61 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 62
Removing the chassis components Prepare for the replacement 1. Review all warnings, cautions, and preparation procedures as detailed in Warnings and precautions. 2. If the MSA is operational, stop all access to the MSA. 3. Press and hold the Power on/Standby button for five seconds to place the MSA - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 63
the controllers 1. Press the controller thumb latch to release the latch handle, and then rotate the latch handle out. 1510i Modular Smart Array maintenance and service guide 63 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 64
firmware version, the serial number of the original chassis may automatically be transferred to the replacement chassis. For continued service and support from HP-authorized service personnel, the serial number of the original chassis must also be physically recorded on the label of the replacement - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 65
1. Slide the module into the chassis power supply slot until the latch clicks into place. 2. Install the other module. 1510i Modular Smart Array maintenance and service guide 65 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 66
Install the SCSI I/O modules 1. Slide the module into the chassis SCSI I/O slot until the latch clicks into place. 2. Install all other SCSI I/O modules or blanks. Install the fan modules 1. Slide the module into the chassis fan slot until the latch clicks into place. 2. Install the other fan module - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 67
following illustration demonstrates installing a Fibre Channel I/O module in the chassis. For the MSA1510i, the 2-Port Ethernet iSCSI I/O module is in this slot. 2. Install switches • External storage enclosures 4. Start up the MSA1510i. 1510i Modular Smart Array maintenance and service guide 67 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 68
transferred to the replacement chassis. SPARE CHASSIS DETECTED CHASSIS SERIAL NUMBER FLASHED UPDATED IMPORTANT: If these messages are displayed, the MSA1510i will automatically restart. • If the following message is displayed, it may safely be ignored. I2C WRITE FAILURE • When the following - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 69
both classes to bear a label indicating the interference potential of the device as well as additional operating instructions for the user. The rating label on the device shows which class (A or B) the equipment cause undesired operation. 1510i Modular Smart Array maintenance and service guide 69 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 70
other than those specified herein, or in the laser product's installation guide, may result in hazardous radiation exposure. To reduce the risk of laser device, other than those specified herein. • Allow only HP Authorized Service technicians to repair the unit. The Center for Devices and Radiological - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 71
Immunity • EN61000-3-2 (IEC61000-3-2) - Power Line Harmonics • EN61000-3-3 (IEC61000-3-3) - Power Line Flicker • EN 60950 (IEC 60950) - Product Safety BSMI notice 1510i Modular Smart Array maintenance and service guide 71 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 72
Japanese notice Korean notice (A&B) Class A equipment Class B equipment 72 Regulatory compliance and safety - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 73
and 3.6 m (12 ft). If you have questions about the type of power cord to use, contact an HP authorized service provider. NOTE: Route power cords so that they will not be walked on and cannot be pinched by items Japanese Power Cord notice 1510i Modular Smart Array maintenance and service guide 73 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 74
at standing workstations. Wear the straps on both feet when standing on conductive floors or dissipating floor mats. • Use conductive field service tools. • Use a portable field service kit with a folding static-dissipating work mat. If you do not have any of the suggested equipment for proper grounding - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 75
where you can drop off your waste equipment for recycling, please contact your local city office, your household waste disposal service, or the shop where you purchased the product. Estonian notice Seadmete jäätmete kõrvaldamine eramajapidamistes Euroopa Liidus 1510i Modular Smart Array maintenance - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 76
d'informations sur les centres de collecte et de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German notice Entsorgung von Altgeräten aus privaten - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 77
savas dzīves vietas pašvaldībā, sadzīves atkritumu savākšanas dienestā vai veikalā, kurā izstrādājums tika nopirkts. 1510i Modular Smart Array maintenance and service guide 77 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 78
o ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice Likvidácia vyradených zariadení v dom - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 79
för hushållsavfall eller affären där du köpte produkten för att få mer information om var du kan lämna ditt avfall för återvinning. 1510i Modular Smart Array maintenance and service guide 79 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 80
80 Regulatory compliance and safety - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 81
drive, verifying, 43 component level repairs, warning, 36 configuring the MSA1510i choosing a utility, 29 diagnostic tools, 29 controller battery replacing, 46 cache HP website, 7 providing feedback, 10 E electrostatic discharge See ESD, 33 1510i Modular Smart Array maintenance and service guide 81 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 82
symbols on equipment, 34 help obtaining, 9 hot-pluggable parts, MSA1510i, 37 HP technical support, 9 HP Systems Insight Manager monitoring LUN parameters, 30 MSA controller parameters, 30 HP Systems Insight Manager, overview, 29 HP-SIM monitoring LUN parameters, 30 MSA controller parameters, 30 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 83
module, 53 contoller, 47 fan module, 55 power supply module, 59 SCSI I/O module, 57 replacement MSA1510i chassis, 64 preparation, 62 replacement MSA1510i completing, 67 replacement MSA1510i chassis installation, 64 proper operation, 68 1510i Modular Smart Array maintenance and service guide 83 - HP StorageWorks MSA1510i | HP StorageWorks 1510i Modular Smart Array maintenance - Page 84
drive, 42 best practices, 42 MSA1510i chassis components, 61 power supply module, 59 SCSI I/O module, 57 replacment parts HP limited warranty, 32 S safety HP, 9 symbols on equipment, 34 T technical support HP, 9 service locator website, 9 thermal failure, caution, 41 tools required for servicing
HP StorageWorks
1510i Modular Smart Array maintenance and
service guide
Part number: 383072–002
Second edition: May 2008