HP StorageWorks MSA2012fc HP 2000 Modular Smart Array Controller Firmware J202
HP StorageWorks MSA2012fc Manual
View all HP StorageWorks MSA2012fc manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA2012fc manual content summary:
- HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 1
HP 2000 Modular Smart Array Controller Firmware J202P01, J212P01, and J302P01 Release Notes HP Part Number: 537811-008 Published: December 2012 Edition: 8 - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 2
© Copyright 2009, 2012 Hewlett-Packard Development Company, L.P. - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 3
Version: • J202P01 (Fibre Channel) • J212P01 (iSCSI) • J302P01 (SAS) Description This package delivers firmware for HP MSA2000 array controllers. and may include enhanced features or fixes to issues found during use and additional qualification testing. NOTE: Approved companion versions of drive - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 4
Smart Array (HP MSA2012fc) • HP 2212fc Modular Smart Array (HP MSA2212fc) • HP 2012i Modular Smart Array (HP MSA2012i) • HP 2012sa Modular Smart Array (HP MSA2012sa) Operating systems Operating systems supported for use with HP MSA2000 G1 Controllers (and when installing the binary firmware package - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 5
firmware update when the status was actually OK. • In the CLI, for the set advanced-settings command, the single-controller on parameter was added to set Single Controller redundancy mode for a single installed controller Power Supply module Voltage/Fan Fault/Service Required (bottom) LED. It - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 6
errors during verify. • Improved performance on RAID 10 vdisks. • When a controller was removed and I/O was in process, the transaction was held in the . • Could not collect a complete set of logs from an array. CLI-specific fixes and enhancements incorporated into J202R10, J212R10, and J302R10: • - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 7
in a restart. Firmware update-specific fixes and enhancements incorporated into J202R10, J212R10, and J302R10: • All drives in enclosures 1 and 3 were reported as unknown following a firmware update. • Partner Firmware Update (PFU) did not properly update the firmware on Controller B. • After - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 8
! Do not power cycle or restart devices during a firmware update. If the update is interrupted or there is a power failure, the module could become inoperative. If this occurs, contact technical support. The module may need to be returned to the factory for reprogramming. 8 Installation instructions - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 9
telnet are enabled on the arrays being updated. ◦ Create a full backup of system data. (Strongly recommended.) ◦ Schedule an appropriate time to install the firmware: - For single domain systems, I/O must be halted. - For dual domain systems, because the online firmware upgrade is performed while - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 10
◦ Updating array controller firmware may result in new event messages that are not described in earlier versions of documentation. For comprehensive event message documentation, see the most current version of the HP 2000 Modular Smart Array Reference Guide. ◦ The Smart Component update process logs - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 11
, you can use the following DOS environment variables: • oa_address: Set this variable for the IP address of array controller. • oa_username: Set this variable for the username of array controller. • oa_password: Set this variable for the password of array controller. Installation instructions 11 - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 12
for the command. • If the username or password contains an exclamation mark (!), enclose the string in single quotes or enter a backslash (\) before the exclamation point. For example" '!manage' or \!manage 5. Follow onscreen instructions. When prompted for logon information, enter credentials for - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 13
firmware package and save it to a temporary directory. Firmware for all HP products is available from the HP Business Support Center website at http://www.hp.com/support specify that the update has completed. In dual-controller systems with Partner Firmware Update enabled, allow an additional 30-60 - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 14
of the system controllers. b. Verify that the system FTP service is enabled. c. Verify that the user you log in as has permission to use the FTP interface and has manage access rights. 5. In single-domain environments, stop I/O to vdisks before starting the firmware update. 6. Open a command - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 15
web browser. If version information is still incorrect, proceed to the next troubleshooting step. 2. If version information does not show that the new firmware has been installed, even after refreshing the browser, restart all system controllers. For example, in the CLI, enter the restart mc both - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 16
firmware MSA2000 HP 2000 Family Modular Smart Array Reference Guide single path to a single LUN. The Windows 2008 MPIO reports a path fail-over, however, the path may not come back. This issue is fixed with Microsoft QFE KB957316, which is available from the Microsoft support website at http:// support - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 17
RHEL 5.2 host may no longer boot into the operating system. HP is working on the issue. Changing to the previous driver (for array using the command line interface (CLI) and restart the management controller (MC) using the command: restart mc a (single controller) or restart mc both (dual controller - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 18
the host indicates a link down state. Disregard the Link LED when the controller removal LED is illuminated. • On the Storage Management Unit (SMU) Manage detected by the Linux operating system. This is a Linux issue, not an array issue. A Linux scan can be used to force detection of the newly - HP StorageWorks MSA2012fc | HP 2000 Modular Smart Array Controller Firmware J202 - Page 19
/dual HBA configurations connected to the same array, controllers. 2. Reboot the crashed controller and perform the firmware update procedure again if applicable. 3. Once the code has been updated, or both controllers are now operational, plug the host cables back in. 4. Bring the storage array
HP 2000 Modular Smart Array Controller
Firmware J202P01, J212P01, and J302P01
Release Notes
HP Part Number: 537811-008
Published: December 2012
Edition: 8