HP StorageWorks MSA30 SCO Operating System support of HP StorageWorks Modular
HP StorageWorks MSA30 Manual
View all HP StorageWorks MSA30 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks MSA30 manual content summary:
- HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 1
System support of hp StorageWorks Modular Smart Array Table of Contents MSA1500 ...2 MSA1000 ...4 MSA30 ...6 MSA20 ...7 MSA support for SCO Operating Systems - Supported Components 8 Hardware ...8 Software ...9 Firmware Upgrade for MSA1000 and MSA1500 10 MSA Deployment...11 Connecting MSA to - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 2
support • Easy management MSA1500 Overview The HP StorageWorks 1500cs Modular Smart Array (MSA1500) is a Fibre Channel storage area network (SAN) 2U controller shelf that connects to HP StorageWorks By using existing SCSI drive enclosures, MSA1000 controller technology, and integrating low cost SATA - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 3
View) Reference # Identifier 1 Redundant controller slot blank 2 Primary controller 3 Status indicators 4 Display panel 5 Display push buttons 6 Power switch 7 Unit ID button and indicator MSA1500 cs (Rear View) Reference # Identifier 1 Reserved for future use 2 Primary Fibre - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 4
drives and data • Supports two MSA30 per MSA1000 box • Offers highest level of fault tolerance (RAID 6) MSA1000 Overview The HP StorageWorks 1000 Modular Smart Array (MSA1000) is a 2 Gb Fibre Channel storage system for the entry-level to midrange storage area network (SAN). It provides the customer - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 5
View) Reference # Identifier 1 Redundant Controller Slot Blank 2 Primary MSA1000 Controller 3 Display Buttons 4 Display Panel 5 Display Indicators 6 Status Indicators 7 Power Switch 8 Power Bay(s) MSA1000 (Rear View) Reference # 1 Identifier 2-Gb Small Form Factor Pluggable - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 6
high return on investment, and with the ability to manage more data with less staffing and increased computing infrastructure utilization MSA1000 and MSA1500 MSA30 Overview The HP StorageWorks Modular Smart Array 30 Enclosure family is the newest HP serviceability, and large storage capacity. 6 - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 7
with a high return on investment, and with the ability to manage more data with less staffing and increased computing infrastructure utilization for better Increases storage density when used with MSA1500 MSA20 Overview The HP StorageWorks Modular Smart Array 20 Enclosure (MSA20) is a SATA 1.5 Gb/s - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 8
HP StorageWorks Modular Smart Array 1000 (P/N: 201723-B22) Firmware Version: 4.94 or higher 3. HP StorageWorks Modular Smart Array 20 (P/N: 335921-B21) Firmware Version: 1.28 or higher 4. HP StorageWorks Modular Smart Array 30 (P/N: 302969-B21) Firmware Version: CP20 or higher 1. HP MSA SAN Switch - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 9
6 version 7.70A or later. Configuring MSA1000 & MSA1500 MSA1000 & MSA1500 ship with a CD containing HP Array Configuration Utility (ACU). The HP Array Configuration Utility software for Smart Array controllers and the StorageWorks Enclosure products makes it easy to configure and expand your disk - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 10
controller firmware files: MSA1000: http://www.hp.com/go/msa1000 MSA1500: http://www.hp.com/go/msa1500cs 2. Using CLI interface of MSA1000/MSA1500 - Refer to the section titled "Updating MSA controller firmware" in "HP StorageWorks Modular Smart Array 1000/1500 Firmware updating guide" available - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 11
the ProLiant server running SCO operating system Configuring logical volumes on the MSA Installing the HBA driver on the SCO servers Identifying logical volumes to the SCO operating system MSA maintenance Connecting MSA to ProLiant servers running SCO operating systems 3 Item - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 12
The following diagrams illustrate these connectivity types Figure 1. Single Server (Single Path) using the Fibre Channel I/O Module (Direct) Figure 2. A Typical MSA1000 Configuration using MSA SAN Switch 2/8 12 - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 13
Figure 3. A Typical Configuration with a Server and MSA1000 using MSA Hub 2/3 Figure 4. A Typical Single-Path Configuration 13 - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 14
Figure 5. A Typical Multi-Path Configuration 14 - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 15
on MSA1000/MSA1500 can be configured using Command Line Interface (CLI) or the ACU utility. 3 Item Creating LUNs using CLI Creating LUNs using ACU Comments 3 HP StorageWorks Modular Smart Array (MSA) Command Line Interface document available at http://h20000.www2.hp.com/bc/docs/support - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 16
Operating System on a ProLiant server. Driver Software Creating HBA Diskette Comments 3 Refer to the SCO Operating System Deployment Guide for OS installation tips on ProLiant platforms. Update the system with latest Maintenance Pack for OS. Install the HP ProLiant Extended Feature Supplement for - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 17
: COMPAQ MSA1000 VOLUME 4.94 Where 'C' - the Controller 'B' - the Bus 'T' - the Target 'L' - the Logical Unit Number 'N' - the instance assigned by the qlc2300 driver to each HBA A typical output of this command with the MSA1000 attached: # sdiconfig -l 0:0,31,0: HBA : (ciss,1) hp ProLiant - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 18
UnixWare 7/OpenServer 6 1. Maximum of two (2) servers per cluster 2. MSA1000 Redundancy 3. MSA1000 Multi-path 4. Online configuration of MSA1000/MSA1500 LUNs 5. Online Firmware upgrade of MSA1000/MSA1500 6. Event logging of MSA1000/MSA1500 7. Systems Management support for MSA1000/MSA1500 18 - HP StorageWorks MSA30 | SCO Operating System support of HP StorageWorks Modular - Page 19
hp.com/go/msa1500cs MSA1000 website at http://www.hp.com/go/msa1000 MSA30 website at http://www.hp.com/go/msa30 MSA20 website at http://h18004.www1.hp.com contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated
1
SCO Operating System support of
hp StorageWorks Modular Smart Array
Table of Contents
MSA1500
..........................................................................................................................................
2
MSA1000
..........................................................................................................................................
4
MSA30
..............................................................................................................................................
6
MSA20
..............................................................................................................................................
7
MSA support for SCO Operating Systems – Supported Components
..........................................................
8
Hardware
.......................................................................................................................................
8
Software
.........................................................................................................................................
9
Firmware Upgrade for MSA1000 and MSA1500
.................................................................................
10
MSA Deployment
...............................................................................................................................
11
Connecting MSA to ProLiant servers running SCO operating systems
.......................................................
11
Figure 1. Single Server (Single Path) using the Fibre Channel I/O Module (Direct)
.................................
12
Figure 2. A Typical MSA1000 Configuration using MSA SAN Switch 2/8
...........................................
12
Figure 3. A Typical Configuration with a Server and MSA1000 using MSA Hub 2/3
............................
13
Figure 4. A Typical Single-Path Configuration
....................................................................................
13
Figure 5. A Typical Multi-Path Configuration
.....................................................................................
14
Configuring logical volumes on the MSA
..............................................................................................
15
Installing the HBA Driver
.....................................................................................................................
16
Configuring MSA LUNs in SCO Operating System
................................................................................
17
Limitations
.........................................................................................................................................
18
For more information
..........................................................................................................................
19