- HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 1
active/passive support Controller firmware 7.0 or later, with active/active support This document details procedures for installing an HP StorageWorks 1000 Modular Smart Array (MSA1000) and its attached storage enclosures. This guide is a companion to the MSA1000 Installation Configuration Overview - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 2
HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP ® is a registered trademark of The Open Group. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 3
the HBA in your servers 38 Step 8: Prepare your switches 39 Step 9: Connect the cables 40 Cabling best practices 40 Connecting the SCSI cables 42 HP StorageWorks 1000 Modular Smart Array installation guide 3 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 4
-Linux environments 65 Prerequisites 65 Installing MSA-specific components on the servers 66 Updating MSA controller firmware (if necessary 68 Configuring the storage 69 4 Configuration procedures-HP-UX environments 71 Prerequisites 71 Additional HP-UX support notes 72 Installing the ACU-CLI - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 5
101 Battery replacement notice 102 Disposal of waste equipment by users in private households in the European Union 102 B Electrostatic discharge 103 Prevention methods 103 Grounding methods 103 C Worksheets 105 Index 119 HP StorageWorks 1000 Modular Smart Array installation guide 5 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 6
2 Basic MSA firmware and configuration options 16 3 MSA1000 and SAN-related websites 18 4 RAID level comparison 26 1 MSA1000 specifications 29 5 Levels of protection against power failures 47 6 MSA1000 startup status lights 51 7 MSA1000 startup messages 52 8 HP-UX required updates for active - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 7
Services>HP StorageWorks Disk Arrays includes: • Physical installation of the MSA • Virtual disk design and configuration of the MSA • Service planning • Service deployment • Installation Verification Testing (IVT) • Customer orientation HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 8
maintenance and service guide • MSA1000/1500 Command Line Interface user guide • MSA1000/1500 firmware updating guide • HP array configuration reference guide (ACU section only) • MSA1000 application notes, including instructions for migrating to active/active array controllers (for each supported - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 9
Figure 1 Medium blue, underlined text (http://www.hp.com) Bold font Element Cross-reference links and e-mail addresses Website addresses • Key names information or specific instructions. NOTE: Provides additional information. HP StorageWorks 1000 Modular Smart Array installation guide 9 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 10
hardware for which this guide pertains. They have Enclosed area contains no operator serviceable parts. WARNING: To power. WARNING: To reduce the risk of personal injury from electrical shock, remove all power cords to completely disconnect power from the power supplies manually handling material. 10 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 11
of drivers, firmware documentation updates, and instant access to numerous other product resources. • After signing up, you can quickly locate your products by selecting Business support and then Storage under Product Category. HP StorageWorks 1000 Modular Smart Array installation guide 11 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 12
Elsewhere, see the HP website: http://www.hp.com. Click Contact HP to find locations and telephone numbers. Helpful websites For third-party product information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.docs.hp.com 12 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 13
or configuring the MSA for you, provide them with this guide and verify that they complete the information in "Worksheets" on page 105. • For information about HP installing and configuring your MSA, see "Intended audience" on page 7. HP StorageWorks 1000 Modular Smart Array installation guide 13 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 14
MSA option kits 4 Rack the MSA 5 Install the hard drives 6 Prepare the servers 7 Install the HBAs 8 Prepare the switches 9 Connect the cables 10 Power on the devices 11 Configure the MSA 9 15410 Figure 1: Overview of MSA installation procedures 14 Installation procedures-All deployments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 15
variables affect your decision: • Variety of operating systems in the SAN • Variety of storage devices in the SAN • Number of controllers in this MSA (single or dual) • Failover software tool to use (dual-control configurations) HP StorageWorks 1000 Modular Smart Array installation guide 15 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 16
(controller and I/O module) and upgraded firmware Windows HP-UX Linux NetWare OpenVMS Tru64 UNIX SCO VMware IMPORTANT: Supported operating system and network configuration restrictions exist. For more information, see the compatibility guide on the MSA1000 website: http://www.hp.com/go/msa1000 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 17
" on page 105. Information in these worksheets is required for multipathing, future configuration changes, and troubleshooting purposes. NOTE: If a supplier is installing the MSA for you, be sure that they complete these worksheets. HP StorageWorks 1000 Modular Smart Array installation guide 17 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 18
, and network configuration limitations • Quickspecs-technical information • Link to the MSA1000-specific Support website Latest support information about all HP products, including the MSA1000: • Available downloads for firmware, software, and drivers • Troubleshooting information, including - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 19
array controller firmware, HP MPIO Basic Failover provides basic path failover and path recovery. Other multipath software already present on the host may not be compatible with HP Basic MPIO. See the MSA1000 compatibility guide for details. HP StorageWorks 1000 Modular Smart Array installation - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 20
run the ACU directly from the MSA Support Software CD.) The Array Configuration Utility-Command Line Interface (ACU-CLI) is a command line interface used to configure an array controller and its storage. The ACU-CLI is primarily used in HP-UX environments. These utilities are provided on - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 21
the configuration. You must include two MSA controllers, two Fibre Channel interconnect devices (switches/fabrics), and a minimum of two HBAs per server. In addition, multipathing software must be installed on each server with access to the MSA. HP StorageWorks 1000 Modular Smart Array installation - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 22
after installing the MSA. • In dual-controller multipath configurations (both active/active and active/passive), you must install some management software (such as multipathing software, management/monitoring utilities, and array configuration software) on each server with access to the MSA. • When - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 23
load balancing (Default - recommended)-MSA firmware initially assigns ownership of all LUNs to one of the two MSA controllers, and then automatically re-assigns LUN ownership evenly between the controllers based on I/O loads of the LUNs. HP StorageWorks 1000 Modular Smart Array installation guide 23 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 24
and re-applying power to the MSA, if necessary, restart the server to rediscover the connection to the MSA controller. For more information, see the HP StorageWorks 1000 Modular Smart Array maintenance and service guide, available on the Technical documentation page of the MSA1000 website: http - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 25
condition, you must power-cycle the MSA. For more information, see the HP StorageWorks 1000 Modular Smart Array maintenance and service guide, available on the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . Plan your storage configuration Proper planning of the - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 26
, but at the price of I/O performance and less fault tolerance. In a vertical configuration, an array uses hard drives from separate storage enclosures and different SCSI buses. In a horizontal configuration, the array uses multiple drives contained within the same storage enclosure. RAID levels In - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 27
performance level that can be achieved. However, the performance considerations are offset by fault tolerance considerations-the greater the number of drives in an array, the higher the probability of one or more failures in that array. HP StorageWorks 1000 Modular Smart Array installation guide 27 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 28
HP website: http://h30099.www3.hp.com/configurator. In addition to the following discussion, see Table 1, "MSA1000 specifications" on page 29 for a detailed list of site requirements. Provide adequate structural support rear of the rack to allow for servicing and airflow. If there are unused spaces - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 29
*Input power and heat dissipation specifications are maximum values and apply to worst-case conditions at full rated power supply load. The power/heat dissipation for your installation will vary depending on the equipment configuration. HP StorageWorks 1000 Modular Smart Array installation guide 29 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 30
associated hardware and software components, including two controllers, two Fibre Channel I/O modules, two Fibre Channel switches, and two HBAs in each server. For information about installing the options, see the instructions that came with the option kit. Go to Table 10: "MSA1000 information" on - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 31
with the rails while the other two people support the weight of the system. CAUTION: To prevent damage and to ease insertion of the device into the rack, support the weight of the device and keep it level when sliding it into the rack. HP StorageWorks 1000 Modular Smart Array installation guide 31 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 32
at a time. A rack may become unstable if more than one component is extended. Use the following instructions to install the MSA and its storage enclosures: 1. Use the provided rack template as a guide to indicate where to place the rails for the component: a. With the front of the template and the - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 33
the inside rear of the rack until the pins extend through the holes marked during the rack template procedure and the locking latch engages. 15424 HP StorageWorks 1000 Modular Smart Array installation guide 33 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 34
d. Loosen the locking nut on the shipping retaining bracket (1) and slide the bracket to the farthest position on the rear of the rail (2). 2 1 15412 e. Repeat steps a through d for the other rack rail. 4. Install the component in the rack: a. Align the device with the rails and slide it into the - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 35
bracket forward (2) until the tab engages the slot in the chassis. 2 1 15422 d. Tighten the thumbscrew on the bracket. e. Repeat these steps for the other rail. HP StorageWorks 1000 Modular Smart Array installation guide 35 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 36
supported hard drives, see the compatibility guide, located on the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 the enclosure documentation. For information about installing hard drives, see the instructions that came with the hard drive and the enclosure. Go to - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 37
installing and configuring your servers, refer to the instructions that came with your server and operating system. Go to Table 12: "Server information" on page 108 to record information about the servers that will connect to the MSA. HP StorageWorks 1000 Modular Smart Array installation guide 37 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 38
and multipath), specific HBAs are required for the different deployments. To confirm that you purchased the correct HBA for your configuration, read the release notes and the compatibility guide, located on the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . NOTE - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 39
with the switch for installation and configuration instructions. Go to Table 11: "External Fibre Channel interconnect device (switch) information" on page 107 to record information about the switches that will connect to the MSA. HP StorageWorks 1000 Modular Smart Array installation guide 39 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 40
or maintenance. specific system architecture first. • Connect the second Fibre Channel HBA that is initialized during the POST to the passive Fibre Channel Interconnect Switch (that is, the Fibre Channel SAN switch that is connected to the MSA1000 passive controller-which is usually the controller - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 41
has already failed and failover did not occur to the passive server, shut down the passive server and cycle the power to ensure that the MSA1000 is recognized. See "Powering off and powering on the MSA" on page 95 for instructions. HP StorageWorks 1000 Modular Smart Array installation guide 41 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 42
carton with each storage enclosure. Recommended SCSI cable connections HP recommends installing additional SCSI I/O modules and connecting storage I/O modules, bus numbers, and box numbers Item Description Bus - MSA1000 0 enclosure 1 External 1 (top port) SCSI storage enclosure 2 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 43
illustration shows the MSA1000 connected to two MSA30 SCSI storage enclosures. NOTE: Tighten the thumbscrews on the SCSI cables to ensure a secure connection. 15416 Figure 3 SCSI cable connections to two MSA30 SCSI storage enclosures HP StorageWorks 1000 Modular Smart Array installation guide 43 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 44
HBAs, and two servers in multipath configurations, all of which use Fibre Channel cables, cable connections must follow specific installation requirements. NOTE: In a multipathing environment, for all servers, the first HBA should be connected to the right-hand controller, as viewed from the front - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 45
cables in a singlepath configuration Figure 4 shows the Fibre Channel cable connections of an MSA1000 being accessed by two servers in a singlepath configuration. Figure 4 Sample Fibre Channel cable connections, singlepath configuration HP StorageWorks 1000 Modular Smart Array installation guide 45 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 46
cable connections, multipath configuration Connect the first Fibre Channel HBA that is initialized during the POST to the active Fibre Channel interconnect switch (that is, the Fibre Channel SAN switch that is connected to the MSA1000 active controller-in other words, the controller on the right as - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 47
to... Provide this level of protection... One power source Protects you from downtime when one of the MSA power supplies fails. The remaining power supply/fan module can operate the MSA until you install a replacement module. HP StorageWorks 1000 Modular Smart Array installation guide 47 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 48
cord into a grounded (earthed) electrical outlet that is easily accessible at all times. • Unplug the power cord from the power supply to remove power to the equipment. • Route the power cord so that it is not likely to be walked on or pinched by items placed against it. Pay particular attention - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 49
15419 Figure 6 Connecting the power cords using two UPSs HP StorageWorks 1000 Modular Smart Array installation guide 49 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 50
) the server before the MSA array completes its start-up sequence, the server may not properly discover the storage. 7. Power on the servers in the SAN with access to the MSA, start the operating system, and log on as a user with administrative control. 50 Installation procedures-All deployments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 51
of your power source. • Review the setup instructions in the previous sections of this guide. • Remove and reinsert the module. • Refer to the HP StorageWorks 1000 Modular Smart Array maintenance and service guide, available on the Documentation CD and the Technical documentation page of the MSA1000 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 52
controller. If the Startup Complete message is not displayed: • Check the cable connections to the MSA • Check the availability of your power source • Review the setup instructions in the previous sections of this guide • Refer to the HP StorageWorks 1000 Modular Smart Array maintenance and service - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 53
is operating properly. A simple test is to verify that your operating system loaded and then open a software application or your browser. If your server is not operating properly, see the documentation that came with the server for help. HP StorageWorks 1000 Modular Smart Array installation guide 53 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 54
of the Support Software CD and MSA controller firmware, and then record the version numbers in Table 10: "MSA1000 information" on page 106. 8. If desired, download the updated firmware or support software CD ISO image from the Web. NOTE: When instructed in later sections of this guide, install this - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 55
of HP array configurations. • Includes easy to use configuration wizards. • Allows the setting of access rights to MSA storage by hosts. • Supports local or remote access. • Runs online (from the server) in Windows and Linux environments. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 56
on the Support Software CD inside the MSA1000/1500 Setup and Management kit. Instructions for installing the ACU on your server are included in the configuration chapters of this guide. For information about using the ACU, see the ACU section of the Configuring Arrays Reference Guide. This guide is - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 57
procedures-HP-UX environments, page 71 • Chapter 5: Configuration procedures-OpenVMS environments, page 77 • Chapter 6: Configuration procedures-VMware environments, page 83 • Chapter 7: Configuration procedures-Other environments, page 89 HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 58
58 Installation procedures-All deployments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 59
documentation for the storage configuration tool you plan to use. Documentation for the ACU and the CLI are available on the Documentation CD and the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . HP StorageWorks 1000 Modular Smart Array installation guide 59 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 60
: • HBA drivers • Array Configuration Utility (ACU) • Array Configuration Utility-Command Line Interface (ACU-CLI) (The ACU-CLI is not supported on IA64 platforms.) • Array Diagnostic Utility (ADU) • HP MPIO Full Featured Device Specific Module (DSM) • HP MPIO DSM (Device Specific Module) Manager To - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 61
Support Software CD and access the CD main menu. c. Install the following optional components (recommended): • Array Configuration Utility (ACU) • Array Configuration Utility-Command Line Interface (ACU-CLI) • Array Diagnostic Utility (ADU) HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 62
• "Obtain desired controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA1000/1500 firmware updating guide, available on the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 63
chosen configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: "Hard drive information" on page 112 and Table 14: "Array (LUN) information" on page 116 to record information about your storage. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 64
64 Configuration procedures-Windows environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 65
documentation for the storage configuration tool you plan to use. Documentation for the ACU and the CLI is available on the Documentation CD and the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . HP StorageWorks 1000 Modular Smart Array installation guide 65 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 66
, the MSA can be connected to the SAN. To install these components on the server: 1. With the HBAs installed in the server, power on the server and start up the Linux operating system. 2. From the console, log on as the root user. 3. Insert the Support Software CD in the CD-ROM drive of the - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 67
HP System Management Homepage before installing the ACU. • For information about using the ACU or the ACU-CLI, see ACU online help or the ACU section of the Configuring Arrays Reference Guide ACU_rpm_filename> is the name of the ACU rpm.) HP StorageWorks 1000 Modular Smart Array installation guide 67 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 68
the Array Configuration controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating guide, available on the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After updating MSA controller - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 69
chosen configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: "Hard drive information" on page 112 and Table 14: "Array (LUN) information" on page 116 to record information about your storage. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 70
70 Configuration procedures-Linux environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 71
documentation for the storage configuration tool you plan to use. Documentation for the ACU and the CLI are available on the Documentation CD and the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . HP StorageWorks 1000 Modular Smart Array installation guide 71 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 72
server (Limitations may exist. See the MSA1000 compatibility guide documents for details.) • Supported storage configuration tools: • MSA Command Line Interface (CLI): Accessed via a direct serial cable connection to the MSA controller • Array Configuration Utility Command Line Interface (ACU-CLI - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 73
-s /tmp/HPACUCLI_IA_v7.47-1.depot 6. Remove the Support Software CD from the CD-ROM drive. NOTE: To start the ACU-CLI, do the following from the console: Navigate to the /opt/compaq/hpacucli/bld directory, and then enter # ./hpacucli. HP StorageWorks 1000 Modular Smart Array installation guide 73 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 74
"Obtain desired controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating guide, available on the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After updating MSA controller firmware, be - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 75
chosen configuration utility. Refer to the appropriate user documentation for instructions. Go to Table 13: "Hard drive information" on page 112 and Table 14: "Array (LUN) information" on page 116 to record information about your storage. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 76
76 Configuration procedures-HP-UX environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 77
documentation for the storage configuration tool you plan to use. Documentation for the ACU and the CLI are available on the Documentation CD and the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . HP StorageWorks 1000 Modular Smart Array installation guide 77 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 78
connections to the MSA, you must supply the WWPNs of the Fibre Channel adapters Owner process ID00000000Dev ProtS:RWPL,O:RWPL,G,W Reference count0Default buffer size0 Current preferred CPU Owner process ID00000000Dev ProtS:RWPL,O:RWPL,G,W Reference count0Default buffer size0 Current preferred CPU - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 79
. For instructions, see your version-specific OpenVMS upgrade and installation manual. d. Install the Fibre_SCSI patch on all system disks. For instructions, see the documentation that came with the kit. e. Restart the OpenVMS server. HP StorageWorks 1000 Modular Smart Array installation guide 79 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 80
"Obtain desired controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating guide, available on the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After updating MSA controller firmware, be - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 81
ID Numbers to the controllers and LUNs When configuring your MSA, you must assign a unique ID number to each MSA controller and to each MSA storage LUN. See the MSA 1000/1500 Command Line Interface user guide for specific instructions. HP StorageWorks 1000 Modular Smart Array installation guide 81 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 82
82 Configuration procedures-OpenVMS environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 83
are available on the Documentation CD and the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . NOTE: For VMware best practices, see http://h71019.www7.hp.com/ActiveAnswers/downloads/4AA1-0818ENW.pdf. HP StorageWorks 1000 Modular Smart Array installation guide 83 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 84
"Obtain desired controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating guide, available on the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After updating MSA controller firmware, be - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 85
multipathing software. • default value is 8. Change the value to meet your configuration needs. If the value is less than the number of LUNs you have presented, you will not see all of your LUNs. The maximum value for this field is 256. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 86
Verify that the value is large enough to support your configuration. If the value is less than the configure the guest OS: • For installation and configuration instructions, see the Guest Operating System Installation Guide configuration tool to connect the virtual machine's CD drive to the ISO - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 87
controls load balancing from the host, you must manually assign the preferred path for each LUN. Perform these tasks using your chosen configuration utility. Refer to the appropriate user documentation for procedural instructions. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 88
Go to Table 13: "Hard drive information" on page 112 and Table 14: "Array (LUN) information" on page 116 to record information about your storage. 88 Configuration procedures-VMware environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 89
Obtain documentation for the storage configuration tool you plan to use. Documentation for the ACU and the CLI are available on the Documentation CD and the Technical documentation page of the 1000 website: http://www.hp.com/go/msa1000 . HP StorageWorks 1000 Modular Smart Array installation guide 89 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 90
migration instructions for NetWare environments, available on the Technical documentation page of the MSA1000 website: http://www.hp.com/go/msa1000 . • If desired, NetWare environments can use the Array Configuration Utility to configure the MSA. The ACU is provided on the MSA Support Software CD - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 91
www.hp.com/go/msa1000 . Included in the SCO-specific document are the procedures for obtaining and installing the HBA drivers for each SCO UNIX operating system. • After installing the MSA, be sure to set the host mode for each SCO UNIX connection to linux. HP StorageWorks 1000 Modular Smart Array - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 92
"Obtain desired controller firmware and Support Software CD versions" on page 54 For instructions on updating MSA controller firmware, see the MSA 1000/1500 firmware updating guide, available on the MSA1000 website: http://www.hp.com/go/msa1000 . IMPORTANT: After updating MSA controller firmware, be - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 93
configuration utility. Refer to the appropriate user documentation for procedural instructions. Go to Table 13: "Hard drive information" on page 112 and Table 14: "Array (LUN) information" on page 116 to record information about your storage. HP StorageWorks 1000 Modular Smart Array installation - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 94
94 Configuration procedures-Other environments - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 95
five seconds to place the MSA array in Standby mode. 5. Verify that the Power on/Standby button LED is amber/off and that the fans are off. 6. Power off all attached hard drive enclosures. 7. Disconnect the power cords from the MSA. HP StorageWorks 1000 Modular Smart Array installation guide 95 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 96
restart) the server before the MSA array completes its start-up sequence, the server may not properly discover the storage. 7. Power on the servers in the SAN with access to the MSA, start the operating system, and log on as a user with administrative control. 96 Powering off and powering on the MSA - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 97
installation of an unsupported HBA driver. The required drivers are provided on the MSA1000/1500 Support Software CD, shipped with the device and available on the MSA websites. 8. Verify that each device in the SAN is operating properly. HP StorageWorks 1000 Modular Smart Array installation guide 97 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 98
98 Powering off and powering on the MSA - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 99
information for this product, always refer to this Series number. This Series used in accordance with the instructions, may cause harmful interference Hewlett-Packard Company may void the user's authority to operate the equipment. HP StorageWorks 1000 Modular Smart Array installation guide 99 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 100
(in brackets are the equivalent international standards): • EN55022 (CISPR 22) - Electromagnetic Interference • EN50082-1 (IEC801-2, IEC801-3, IEC801-4) - Electromagnetic Immunity • EN60950 (IEC950) - Product Safety Japanese notice Japanese power cord notice BSMI notice 100 Regulatory notices - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 101
user-serviceable components inside. • Do not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP Authorized Service is classified as a CLASS 1 LASER PRODUCT. HP StorageWorks 1000 Modular Smart Array installation guide 101 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 102
, contact your HP Authorized Reseller or your Authorized Service Provider. WARNING! Your Accelerator Array contains Lithium Manganese collection system or return them to HP, your authorized HP Partners, or their agents. Disposal of waste equipment by users in private households in the European - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 103
mats. • Use conductive field service tools. • Use a portable field service kit with a folding static- MSA1000. NOTE: For more information on static electricity, or assistance with product installation, contact your HP Authorized Reseller. HP StorageWorks 1000 Modular Smart Array installation guide - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 104
104 Electrostatic discharge - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 105
included in this section: • MSA1000 information, page 106 • External Fibre Channel interconnect device (switch) information, page 107 • Server information, page 108 • Hard drive information, page 112 • Array (LUN) information, page 116 HP StorageWorks 1000 Modular Smart Array installation guide 105 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 106
, clustered-servers ❑ Multipath, non-clustered ❑ Multipath, multiple clustered-servers MSA1000 Serial number (on the product label) Controller firmware: Version shipped on the controller Version available on the Web Support Software CD: Version shipped with the MSA Version available on the Web - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 107
version Switch IP address Switch WWNN Switch WWPN Additional device for multipath configurations: Make and model Switch firmware version Switch IP address Switch WWNN Switch Switch IP address Switch WWNN Switch WWPN HP StorageWorks 1000 Modular Smart Array installation guide 107 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 108
and version / kernel Service pack / errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA WWNN HBA WWPN (also called Adapter ID) Setting Additional items for multipath configurations: Multipathing software and version Additional - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 109
HBA model Additional HBA server slot location Additional HBA WWNN Additional HBA WWPN Additional items for clustered configurations: Clustering software and version Cluster cabling must be the same as the companion device HP StorageWorks 1000 Modular Smart Array installation guide 109 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 110
and version / kernel Service pack / errata Server name HBA model HBA server slot location HBA firmware version HBA driver version HBA boot BIOS firmware HBA WWNN HBA WWPN (also called Adapter ID) Setting Additional items for multipath configurations: Multipathing software and version Additional - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 111
HBA model Additional HBA server slot location Additional HBA WWNN Additional HBA WWPN Additional items for clustered configurations: Clustering software and version Cluster cabling must be the same as the companion device HP StorageWorks 1000 Modular Smart Array installation guide 111 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 112
, record basic information about the drives in this table. • As you configure the storage, enter the array letter (LUN #) of the drive in this table and record information about the arrays (LUNs) in Table 14 "Array (LUN) information" on page 116. NOTE: Worksheets for four (4) storage enclosures - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 113
12 13 14 Array letter (LUN #) NOTE: Box numbers are assigned to enclosures based on their connection to the MSA1000. See Figure 2 "SCSI I/O modules, bus numbers, and box numbers" on page 42 for the box number assignment pattern. HP StorageWorks 1000 Modular Smart Array installation guide 113 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 114
Table 13 Hard drive information (continued) Box number Drive bay Transfer rate Drive capacity Spindle speed 1 2 3 4 Box number 5 assigned to this enclosure 6 7 ________ 8 9 10 11 12 13 14 Array letter (LUN #) 114 Worksheets - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 115
Table 13 Hard drive information (continued) Box number Drive bay Transfer rate Drive capacity Spindle speed 1 2 3 4 Box number 5 assigned to this enclosure 6 7 ________ 8 9 10 11 12 13 14 Array letter (LUN #) HP StorageWorks 1000 Modular Smart Array installation guide 115 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 116
Table 14 Array (LUN) information Basic settings SSP (ACL) settings Array letter (LUN #) Capacity RAID level HBA (WWPN or name) Host mode (profile) O/S share name 116 Worksheets - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 117
Table 14 Array (LUN) information (continued) Basic settings SSP (ACL) settings Array letter (LUN #) Capacity RAID level HBA (WWPN or name) Host mode (profile) O/S share name HP StorageWorks 1000 Modular Smart Array installation guide 117 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 118
Table 14 Array (LUN) information (continued) Basic settings SSP (ACL) settings Array letter (LUN #) Capacity RAID level HBA (WWPN or name) Host mode (profile) O/S share name 118 Worksheets - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 119
, requirements 28 equipment symbols 10 ESX 2.5.X Server 85 ESX 3.0.X Server 86 F FCC notice 99 fibre cables, connecting 44 firmware determining which version to use 15 HP StorageWorks 1000 Modular Smart Array installation guide 119 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 120
HP authorized reseller 12 storage website 12 Subscriber's choice website 11 technical support 11 HP-UX environments additional notes 72 configuring -CLI HP-UX environments of the MSA 51 Linux environments configuring the storage 69 installing the configuration planning 25 sizing considerations 27 M - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 121
startup 53 designating a management server 37 preparing for use with the MSA 37 setup illustrated steps 14 listed steps 13 recommendations 13 shipping bracket 35 HP StorageWorks 1000 Modular Smart Array installation guide 121 - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 122
52 striping methods 26 Subscriber's choice, HP 11 support software CD using in HP-UX environments 73 using in Linux power related 48 symbols on equipment 10 websites HP documentation 8 HP storage 12 HP Subscriber's choice 11 MSA and SAN 18 weight considerations 28 Windows environments configuring - HP StorageWorks Modular Smart Array 1000 | HP StorageWorks 1000 Modular Smart Ar - Page 123
prerequisites for the MSA 59 updating MSA firmware 62 HP StorageWorks 1000 Modular Smart Array installation guide 123
HP StorageWorks
1000 Modular Smart Array
installation guide
Product Version:
Controller firmware 5.xx or earlier, with active/passive support
Controller firmware 7.0 or later, with active/active support
This document details procedures for installing an HP StorageWorks 1000 Modular Smart Array
(MSA1000) and its attached storage enclosures. This guide is a companion to the MSA1000 Installation
Configuration Overview poster.
Note:
Two versions of firmware are available for the MSA1000: active/passive and active/active. For more
information, see “
Determine which version MSA controller firmware to use”
(in this guide) and the
compatibility guides on the MSA1000 website:
.
Part number: 254092–008