HP StorageWorks P9000 HP StorageWorks P9000 Configuration Guide: VMware (AV400
HP StorageWorks P9000 - Disk Arrays Manual
View all HP StorageWorks P9000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks P9000 manual content summary:
- HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 1
HP StorageWorks P9000 Configuration Guide: VMware P9500 Disk Array Abstract This guide provides requirements and procedures for connecting a P9000 disk array to a host system, and for configuring the disk array for use with VMware. This document is intended for system administrators, HP - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 2
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 3
service ...17 Related information ...17 HP websites ...17 Conventions for storage capacity values 18 HP product documentation survey 18 A Path worksheet 19 Worksheet ...19 B Disk array supported emulations 21 Supported emulations ...21 Emulation specifications ...21 P9000 Configuration Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 4
Glossary 25 Index 27 4 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 5
Figures 1 SNMP configuration 9 2 Point-to-point fabric topology example 11 3 Multi-cluster environment 12 P9000 Configuration Guide: VMware 5 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 6
Tables 1 Fabric topology settings 11 2 Fabric zoning and LUN security settings 13 3 Error conditions ...15 4 Path worksheet ...19 5 Supported emulations 21 6 Emulation specifications 21 6 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 7
not support using HP StorageWorks Command View Advanced Edition Suite Software from a Guest OS. • HP StorageWorks P9000 Array Manager Software • Check with your HP representative for other P9000 software available for your system. Fibre Channel interface The P9000 family of disk arrays supports the - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 8
SNMP manager. SNMP properties are usually set from the SVP but they can also be set remotely using Remote Web Console Software or Command View Advanced Edition Suite Software . For specific procedures, see the applicable user guide. 8 Installing and configuring VMware for the P9000 family of disk - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 9
P9000 Command View Advanced Edition Suite Software. For information about how to designate a command device, see the applicable user guide. Creating scripts to configure all devices at once may save you considerable time. Installation roadmap Perform these actions to install and configure the disk - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 10
(by assigning LUNs) In Command View Advanced Edition, LUN mapping includes: • Configuring ports • Creating storage groups • Mapping volumes and WWN/host access permissions to the storage groups For details see the HP StorageWorks P9000 Provisioning for Open Systems User Guide . Note the LUNs and - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 11
and software configuration of the host. Notify your HP representative if you install storage agnostic software (such as backup or cluster software) that may require specific settings. Configuring the Fibre Channel ports Configure the disk array Fibre Channel ports by using Command View Advanced - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 12
adapters (FCAs) that connect the host to the disk array. Loading the operating system and software Follow the manufacturer's instructions to load the operating system and software onto the host. Load all OS patches and configuration utilities supported by HP and the FCA manufacturer. Installing and - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 13
disk array The HP service representative performs the following steps to connect the disk array to the host: 1. Verifying operational status of the disk array tree in the left panel, select HKEY_LOCAL_MACHINE > System > CurrentControlSet > Services > Disk. P9000 Configuration Guide: VMware 13 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 14
servers or in a virtual to physical configuration, set the SCSI controller to physical mode. Selecting the SCSI emulation driver Select the HP supported SCSI emulation driver for a guest 2.6 kernel use the BusLogic SCSI driver. 14 Installing and configuring VMware for the P9000 family of disk arrays - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 15
system is not mounted after re- Verify that the host was restarted correctly. booting. Verify that the file system attributes are correct. The disk array performs a self reboot Reboot the host. because the disk array was busy or it logged a panic message. P9000 Configuration Guide: VMware 15 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 16
Error condition Recommended action The disk array responds "Not Ready" Contact HP. or the disk array has displayed "Not Ready" and timed out. The host host hangs. Make sure there are no duplicate disk array TIDs and that disk array TIDs do not conflict with any host TIDs. 16 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 17
Reference Guide • HP StorageWorks P9000 Owner Guide • HP StorageWorks P9000 Provisioning for Open Systems User Guide • HP StorageWorks P9000 Remote Web Console User Guide You can find these documents on the HP Manuals website: http://www.hp.com/support/manuals In the Storage section, click Disk - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 18
• http://www.hp.com/storage/spock Conventions for storage capacity values HP P9000 storage systems use the following values to calculate physical storage capacity values (hard disk drives): • 1 KB (kilobyte) = 1,000 (103) bytes • 1 MB (megabyte) = 1,0002 bytes • 1 GB (gigabyte) = 1,0003 bytes • 1 TB - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 19
: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: P9000 Configuration Guide: VMware 19 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 20
20 Path worksheet - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 21
Yes LUSE & CVS Yes Yes Yes Yes Yes NOTE: For the P9500 when connected to external storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host. This allows external storage LDEVs to be configured without losing data. Using any other emulation may cause data loss - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 22
) ÷ 10242 The value n is the number of volumes combined together. For example, with 8 combined volumes: OPEN-V*8. Note 1: The availability of an emulation depends on the disk array. 22 Disk array supported emulations - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 23
as SCSI disk devices, even though the interface is Fibre Channel. Note 3: The command device (used for RAID Manager) is user) × 1024/720 × n Example For a CVS LUSE volume with capacity = 37 MB and n = 4: # of cylinders = 37 × 1024/720 × 4 = 52.62 × 4 = 53 × 4 = 212 P9000 Configuration Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 24
OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = (capacity (MB) specified by user) × 16/15 × n Example For an OPEN-V CVS LUSE volume with capacity = 49 MB and n = 4: # of cylinders = 49 × 16/ You set the volume size using Remote Web Console. 24 Disk array supported emulations - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 25
. A volume on the disk array that accepts HP StorageWorks Continuous Access or HP StorageWorks Business Copy control operations which are then executed by the array. Control unit. Custom volume size. CVS devices (OPEN-x CVS) are custom volumes configured using array management software to be smaller - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 26
notebook computer built into the disk array. The SVP provides a direct interface to the disk array and used only by the HP service representative. Storage Virtualization System, an appliance that manages multiple disk array storage systems. Target ID. On the P9000 or XP array, a volume is a uniquely - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 27
command device(s) one LDEV as a, 9 RAID Manager, 9 Command View Advanced Edition, 9, 10, 11 Command View Advanced Edition , 9, 10, 11 configuration device emulation types, 8 disk array, 10 FCAs, 12 Fibre Channel ports, 11 host, 12 Host Mode, setting, 10 port, 11 system option mode, 11 contacting HP - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 28
, 10 R R-SIMS, 15 RAID Manager command devices, 9 related documentation, 17 Remote Web Console, 9, 10, 11 requirements, disk array, 7 S SCSI disk, Fibre Channel interface and term "SCSI disk", 8 security, LUN, 12 server support, 7 SIMS, 15 storage capacity, 7 storage capacity values conventions, 18 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 29
Z zoning, fabric, 12 P9000 Configuration Guide: VMware 29 - HP StorageWorks P9000 | HP StorageWorks P9000 Configuration Guide: VMware (AV400 - Page 30
30
HP StorageWorks
P9000 Configuration Guide: VMware
P9500 Disk Array
Abstract
This guide provides requirements and procedures for connecting a P9000 disk array to a host system, and for
configuring the disk array for use with VMware. This document is intended for system administrators, HP
representatives, and authorized service providers who are involved in installing, configuring, and operating the
HP P9000 storage systems.
Part Number: AV400-96301
First edition: October 2010