HP StorageWorks P9000 HP StorageWorks P9000 Continuous Access Journal User Gui
HP StorageWorks P9000 - Disk Arrays Manual
View all HP StorageWorks P9000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StorageWorks P9000 manual content summary:
- HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 1
how to use HP StorageWorks P9000 Continuous Access Journal Software to replicate data between local and remote HP StorageWorks P9000 disk arrays and to achieve disaster tolerance with maximum application performance. Topics include setting up remote copy connections, configuring the storage system - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 2
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 3
software components 9 P9500 storage systems...10 Main and remote control units 10 Pair volumes...11 Journal volumes...11 Journals...11 Data path...12 Consistency groups and journals 12 Remote Web Console...12 RAID Manager 24 RAID group configuration 24 Fibre Channel port configuration 24 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 4
39 On setting up ports ...40 Distances supported for Fibre Channel type, number of switches 40 Supported data path configurations 41 5 Configuration operations 43 Configuration workflow ...43 Define Fibre Channel port attributes 43 Configure storage systems for Continuous Access Journal, define - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 5
secondary storage system 90 Manage power- configuration 103 10 Troubleshooting 104 General troubleshooting...104 Troubleshooting logical paths 105 Troubleshooting suspended pairs 107 Troubleshooting using Remote Web Console 109 Error codes ...109 Troubleshooting using RAID Manager 109 Service - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 6
...131 Virtual LUN ...131 Cache Residency...131 Auto LUN...131 LUN Manager...131 Thin Provisioning ...132 Data Retention ...132 Performance Monitor ...133 B Continuous Access Journal configurations with Continuous Access Synchronous 134 Sharing volumes with Continuous Access Synchronous 134 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 7
D Continuous Access Journal GUI reference 151 Journal Operation window ...151 Journal Detail window ...154 Change Journal Option dialog box 157 Change Mirror Option dialog box 157 Edit Journal Volumes dialog - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 8
delta resync function • Configuration using multiple primary and secondary storage systems Continuous Access Journal software With Continuous Access Journal, application data is copied to a secondary P9500 system at a remote location. Continuous Access Journal is designed to support a remote site - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 9
to the read journal command from the secondary storage system. This is true even if the primary storage system and secondary storage system are connected using a channel extender product. Hardware and software components A typical configuration consists of a P9500 or externally attached system on - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 10
journal volume(s). Management software consists of: • Remote Web Console graphical user interface (GUI) • RAID Manager NOTE: • Continuous Access Journal Z processing continues uninterrupted if the SVP reboots or even if the SVP fails. • Continuous Access Journal Z does not support operations in - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 11
storage volume (S-VOL) and the following operations: • Issue read-journal commands to the MCU. • Manage the copying of journal data from master to restore journal. • Manage the copying of restore journal data to S-VOL. • Assist in managing pair status and configuration different RAID configurations. - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 12
is required for Continuous Access Journal. HP recommends two or more independent connections to groups are defined using RAID Manager. When you issue a pair command, the copy operation is from RAID Manager are assigned to journal numbers. The specification of consistency group number storage - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 13
perform these operations. Users without Administrator or Continuous Access Journal write access can only view Continuous Access Journal information. • If the RAID Manager computer is not installed, contact your HP account team for information on Continuous Access Journal configuration services. RAID - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 14
with multiple MCUs, perform the pair resume storage system: • The update is written to the P-VOL. • The update is copied to the master journal along with metadata that includes sequence and other consistency information. Replication to the secondary system is prompted by the read-journal command - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 15
data transfer. Make sure that your channel extenders are capable of supporting RIO. Contact HP Technical Support for more information. If an update copy copy activities and maximize data transfer, the P9500 storage system utilizes a special write command, which is allowed only for Continuous Access - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 16
storage system. Pair status Every pair operation results in a change in pair status. You should monitor pair status to insure that an operation completed successfully. Also, pairs must have a specific status in order for specific a pair is split by the user (pairsplit-r), the primary or secondary - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 17
3DC & 4x4 Open MF in the following Continuous Access Journal configurations: - When running a 3DC system - When performing Continuous Access Journal operations on multiple primary and secondary storage systems Interfaces Supported host platforms Data path The following program products can be used - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 18
Disk Array or XP10000 Disk Array is used as the primary or secondary storage supported. Cache and Nonvolatile Storage (NVS) Host failover software Must be operable for primary and secondary systems to insure pair creation success. The remote system cache should be configured to adequately support - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 19
consistency groups • Up to four journals can be registered in one RAID Manager consistency group. when multiple primary and If there are four storage systems, you must create one journal for each storage secondary storage system system. • Up to 8,192 pairs, the total number of pairs registered - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 20
. This involves understanding supported configurations, the need for fibre channel switches, the number of ports your data transfer requirements call for. • Plan data volumes (primary and secondary volumes). This involves understanding the sizing of P-VOL and S-VOL, RAID group considerations, and - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 21
the host application's write-workload an extended performance-monitoring feature. The number of read/write transactions, or input/output per second (IOPS), is also collected by the software. You will use IOPS to set up a proper data transfer speed, which you insure through RAID group configuration - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 22
performance monitoring software, collect the following: • Disk-write bytes-per-second (MB/s) for every physical volume that will be replicated needed, and import into a spreadsheet tool. Sizing journal volumes Determining between the primary storage system and secondary storage system, specify zero - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 23
storage system. • t is the length of time until the delta resync operation starts. CAUTION: The recommended journal volume capacity is 6 GB or more. If the capacity is less than 6 GB, system performance instructions remote array must manages application (or group of applications a replication volume, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 24
RAID groups. Fibre Channel port configuration The Fibre Channel ports on the P9500 have an IOPS threshold. Use the performance monitoring journal volumes for your Continuous Access Journal system on primary and secondary arrays. Journal volumes should be sized according to RPO and write-workload. - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 25
to configure custom-size LUs that are smaller than standard-size LUs. When custom-size LUs are assigned to a Continuous Access Journal pair, the S-VOL must have the same capacity as the P-VOL. For details about Virtual LUN feature, see HP StorageWorks P9000 Provisioning for Open Systems User Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 26
of slots 122,752 = the number of slots that a bitmap area can manage NOTE: If using LUSE volumes, add 1 to the required number of bitmap storage system Installed additional shared memory for Cnt Ac-J Base(16KLDEV,SI/VM) 64KLDEV,SI/VM Extension1,FCV2,DP,Snapshot,TPF Total number of LDEVs in storage - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 27
32,768, the total number of LDEVs in the storage system is the maximum number of pairs that can be created. The maximum number of pairs is limited to 32,768. Priority set for initial copy operations and scheduling order For performing more initial copy operations than the setting value of the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 28
a Continuous Access Journal pair, the primary storage system generates sense information. This information must be transferred to the remote site using the host failover software for effective disaster recovery. RAID Manager provides failover commands that interface with industry-standard failover - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 29
Manager ◦ Thin Provisioning ◦ Data Retention ◦ Performance Monitor Planning for Continuous Access Journal with multiple P9500 systems A Continuous Access Journal system can be configured with up to four primary P9500 systems and four secondary P9500 numbers issued by RAID Manager when the host - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 30
a RAID Manager consistency group. With multiple P9500 systems, however, up to four journals may be registered in a RAID Manager consistency group in the configuration of Figure 4 (page 29). Figure 5 (page 30), Figure 6 (page 31), and Figure 7 (page 31) show varying configurations of storage systems - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 31
journals-2 Figure 7 RAID Manager consistency group with multiple journals-3 Planning for previous models Continuous Access Journal can be used to perform remote copy operations between P9500 and XP24000/XP20000 Disk Array. Data can be copied from P9500 to XP24000/XP20000 Disk Array, or vice versa - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 32
operations. See HP StorageWorks P9000 Remote Web Console User Guide for information. • Make sure that primary and secondary systems are properly configured for Continuous Access Journal operations; for example, cache memory considerations. See the item for Cache and Nonvolatile Storage in the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 33
can be improved by issuing the command from RAID Manager. Mode 474 ON: The performance of the initial copy processing of the Continuous Access Journal pair can be improved by issuing the command from RAID Manager. Mode 474 OFF: Normal operations are performed. Guidelines for preparing systems for - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 34
multitarget configuration, set this mode to ON. Mode 506 ON: The delta resync operation is performed if multiprocessing of the communication command issued from MCU to RCU is up to 128 performed. System option modes can only be changed by an HP representative. 34 Planning volumes - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 35
configuration you use help insure that your update data arrives at the remote site in a time consistent with your organization's RPO. This chapter provides instructions peak workload on the production disks, then add extra capacity to write-workload, and an extended peak workload is experienced, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 36
physical disks. For access patterns that favor multiple writes to a relatively small region of disk, workload data is collected using performance monitoring software. Please see "Measuring write over 10-minute segments. Figure 9 Write-workload spreadsheet 2. Locate the highest peak. Based on your - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 37
by arranging the values in six 10-minute intervals, as follows: a. In cell E4 type, = average(b2:b7), and press Enter. (Most spreadsheet tools have an average function.) This instructs the tool to calculate the average value in cells B2 through B7 (six 10-minute intervals) and populate cell E4 with - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 38
Figure 11 60-minute rolling averages graphed over raw data 2. From the spreadsheet or graph, locate the largest or highest rolling average value. This is These are discussed in the following sections. Latency Network latency affects replication. It is the amount of data that can be present in the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 39
commands and data. RCU target ports must be configured on both primary and remote storage systems for Continuous Access Journal operations. • External port: Required for External Storage and RCU target ports P9500 ports are designated as microprocessors. One microprocessor manages the data traffic for - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 40
performance monitoring software shows peak IOPS at 10,000, and if factory specifications be established in both directions. HP strongly recommends that you establish configured before you can add the secondary storage systems and create the Continuous Access Journal volume pairs. Distances supported - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 41
loop only) is a direct link between the local and remote arrays. NL-port (Node Loop) are supported for the data path and host-to-system path. • Switch are supported. • Extender connection, as shown in Figure 15 (page 42). Figure 13 Direct connection configuration Supported data path configurations 41 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 42
on particular switches, depending on the configuration and the settings of switch routing. For further details, contact your HP account team. • Make sure that your channel extenders are capable of supporting remote I/O. For further details, contact your HP account team. 42 Planning the data - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 43
systems for Continuous Access Journal command and data transfer. Prerequisite information • If initiator ports and RCU target ports are not configured on both primary and remote storage systems, the following problems occurs and remote copy operations are not performed: ◦ The administrator at the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 44
must be performed: ◦ All affected data volume pairs must be released. ◦ All logical paths must be deleted from the initiator port to the remote storage system. ◦ Preview list. To view detailed information about the error, right click the error code and select Error Detail. 44 Configuration operations - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 45
Configure storage systems for Continuous Access Journal, define logical paths Prerequisite Information • This procedure must be performed on both primary and secondary systems. • The primary and secondary systems must already be configured for Continuous Access Journal operations. See "System - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 46
The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array storage system is 4. 8. The Path . The DKC Option dialog box displays, as shown below. 46 Configuration operations - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 47
needed. A maximum of eight logical paths are supported. Prerequisite information Please review the prerequisites for configuring logical paths in "Configure storage systems for Continuous Access Journal, define logical paths " (page 45). To configure additional logical paths 1. In Remote Web Console - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 48
Cancel. 9. Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select Error Detail. Specify number of volumes for initial copy, resync You can specify - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 49
default, 64 volumes, you limit the impact of initial copy operations on storage system performance. • When you specify more than 64, the system starts the first code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 50
17). • Journal volumes must be registered in a journal before the initial pair-copy operation is performed. • Journal volumes must be registered on both local and remote systems. • A journal can contain > Journal Operation. The Journal Operation window is displayed. 50 Configuration operations - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 51
2. Click to change the mode from View to Modify. 3. To register journal volumes in an existing journal, to register. • PG(Ext.), then enter the external parity group number in the box, and click Show. A list of volumes in the specified external parity group displays. Select the volumes that you want - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 52
groups are shown below Registered in the tree. If an error occurs, right click the item in the Preview list and select Error Detail. 52 Configuration operations - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 53
specific status. Before performing any operation, check pair status. • Find status requirements under the Prerequisites sections for each operation. • To view systems, and all logical paths must be defined. See "Configure storage systems for Continuous Access Journal, define logical paths " (page - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 54
running on a primary storage system or secondary storage system, stop Performance Monitor before performing the initial copy to avoid overloading with TCP/IP traffic. For details about Performance Monitor, see HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. To create an - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 55
• Data for the selected volume displays in the P-VOL box. The numbers indicate the port, GID, LUN, and volume. • One P-VOL displays at a time, even if you selected multiple volumes for pairing. The volume with the lowest number displays first. 5. Specify an S-VOL as follows: 1. Select the port, GID, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 56
list to specify S-VOLs. If you selected multiple volumes as P-VOLs, you can instruct the system to automatically assign S-VOLs for the remainder of P-VOLs. Do this value is 32, and 1 to 256 can be specified. For performing more initial copy operations than the setting value of the Maximum Initial - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 57
by the CU configuration or a remote copy path error. Review the error, release the pair • A pair can be split from the primary or secondary system. • Pair status must be COPY or PAIR to perform the split operation. • If you want to split multiple pairs at the same time, the pairs must belong to the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 58
Continuous Access Journal > Pair Operation. 2. Click to change the mode from View to Modify. 3. In the tree, select the port or host group. Paired , update data is copied to the secondary data volume. When the secondary storage system receives a request for splitting a pair, all the journal data ( - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 59
> Journal Operation. 2. Click to change the mode from View to Modify. 3. In the tree, expand Registered then of volumes. The term "Point-in-Time (PiT)" refers to an act of obtaining a copy of data immediately application at the primary storage system to resume business activities. Split a mirror 59 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 60
. This section describes the pair resync operation. Also, the instructions are used when performing the delta resync operation. Prerequisite information • The pair resynchronizing operation is performed from the primary storage system only. • Pairs in PSUS or PSUE status is resynchronized. • Best - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 61
done to insure internal communications between the storage systems. However, if remote command devices are used, the update operation needs not be performed for five minutes or more. See "Configuring the delta resync operation environment to support remote command devices" (page 141) for details. To - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 62
from the master journal to the restore journal restarts. Prerequisite information • The resynchronize a mirror operation is performed from the primary storage system only. • Use the RAID Manager to restore a mirror when the consistency group contains multiple journals (see Figure 5 (page 30), Figure - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 63
support the system that consists of multiple primary and secondary storage systems, an error occurs if you try to restore a mirror by using the Remote Web Console in this system configuration. • Best practice is to resynchronize when I/O load is low. This reduces impact on performance view detailed - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 64
configuration (s), HP strongly recommend that the secondary data volumes are defined to remain offline to avoid this problem. To delete a pair or pairs 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation. 2. Click to change the mode from View - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 65
error code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select and restore journals end. Prerequisite information • This operation can be performed from either the primary or secondary systems. • When one journal - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 66
select Delete. 7. Click Apply to apply the settings. If an error occurs, the error code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select Error Detail. 66 Pair operations - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 67
data management is performed in the Split status (PSUS/PSUE). Monitoring using the Remote Web Console is done at the user's discretion. Monitoring should be repeated frequently. Email notifications of problems can be set up using the Remote Web Console. For details see HP StorageWorks P9000 Remote - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 68
user has split the pair or released the pair; the pair is no longer synchronized. Read/Write • The primary and secondary systems keep track of journal data discarded during the pairsplit operation. • When the operation is performed to SMPL. • The pair or command devices are ready for the delta - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 69
from PFUL to PFUS, and the pair is suspended. • The PFUS status is displayed by RAID Manager and Remote Web Console as PSUS. Read/Write *3 Read Only, unless write option is enabled. • If a virtual volume of Thin Provisioning (V-VOL) is used as a Cnt Ac-J S-VOL, and the capacity of a pool-VOL is - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 70
the Cnt Ac-J S-VOL are the same because the data update stopped. To make the above mentioned condition, make the configuration to execute the delta resync operation to support the remote command devices, and then change the status of all Cnt Ac-J pair and Cnt Ac-S pair which belong to the desired - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 71
secondary systems. See "Usage Monitor window " (page 183) for instructions on viewing the usage rate of a journal volume. • When the pair status is COPY, you cannot add cache or shared memory to or remove it from the storage system. Before performing either of these tasks, split any pairs with COPY - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 72
not insured. • This S-VOL cannot be used for disaster recovery at the secondary site. • This status is indicated when: - The pair is split by the user using the Suspend Range-Volume (LU) pairsplit option. - The pair is suspended due to a failure that did not affect the entire journal. Mirror • The - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 73
. When the pair is resynchronized, the primary and secondary systems perform the following operations: • The secondary system sends the S-VOL Internal/External VOL: Specify whether internal volumes or external volumes display in the list. If you select All, all the internal and external volumes - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 74
volumes, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. A device ID ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. For details on a virtual volume, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. "00 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 75
for remote copy operations data and I/O statistics for monitored volumes on the storage system in the Usage Monitor window. This chapter shows you how to do monitoring in Performance Monitor. See HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide for instructions. Figure 16 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 76
about external drives). - A device ID ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume (see HP StorageWorks P9000 Provisioning for Open Systems User Guide for more information on a virtual volumes). • Journal, to view I/O statistics for a specific journal - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 77
is kilobytes per second. The number of asynchronous remote I/Os per second at the primary storage system. The number of journals at the primary storage system. The average transfer rate for journals in the primary storage system. The unit is kilobytes per second. The remote I/O process time on the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 78
storage system. The unit is kilobytes per second. The remote I/O process time on the secondary storage pair operations performed on the journal. Monitoring these statuses can help you resolve problems and window and provides definitions for statuses. To view journal status 1. In Remote Web Console, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 79
Ac-J pair during the delta resync operation. This is the unused journal which is not registered data volumes. Monitor logical path status To view logical path status 1. In Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > DKC Operation. 2. In the Display box, select DKC - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 80
storage systems. - A logic error is detected between the primary and the secondary storage systems. • Resource Shortage (Port). The local system rejected configuration the remote system was performed. When clicked, the DKC Operation window refreshes when it redisplays. 80 Monitoring the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 81
Actions > Remote Copy > Continuous Access Journal > History. The History window opens. The History window may not show the latest operation history. To view the latest operation history, go to the next step. 2. Select File > Refresh. The operation history is updated. If Continuous Access Journal has - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 82
Remote Web Console, select Actions > Remote Copy > Continuous Access Journal > Pair Operation. 2. Click to change the mode from View to Modify. 3. In the tree, select the port that you have configured for the pair, or a host group (displayed below the ports). The volumes for the port or host group - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 83
used by journals Most Continuous Access Journal pair operations are performed on multiple pairs. This is done using journals. You Journal Operation. The Journal Operation window displays. 2. Click to change the mode from View to Modify. 3. Operate either of the following: In the tree, right click - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 84
unchanged. NOTE: This setting does not effect master journals unless the RAID Manager horctakeover command is used to change a master journal into a restore journal. rightmost column of the Preview list. To view detailed information about the error, right click the error code and select Error - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 85
Continuous Access Journal pair operations are performed on multiple pairs. This is options can be changed on the primary storage system and secondary storage system. • To change mirror options, window displays. 2. Click to change the mode from View to Modify. 3. Operate either of the following: In - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 86
you want a mirror to split immediately after a path becomes blocked, ask HP Technical Support to set system option mode 448 to ON and set system option mode specified in the secondary storage system. For a pair using the delta resync configuration, select Yes in the primary storage system. 8. For - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 87
RAID Manager horctakeover command is used to change a master journal into a restore journal. 9. For Delta resync Failure, specify the processing that takes place when the delta resync operation cannot be performed. (This option specified on the primary storage instructions mode from View to Modify. - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 88
Prerequisite information • Journals can be deleted from the primary storage system or secondary storage system. • When all mirrors in the journal are error code appears in the rightmost column of the Preview list. To view detailed information about the error, right click the error code and select - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 89
• Modifying the data-transfer threshold can be performed from the primary storage system or secondary storage system. • The setting is made in the Operation. The DKC Operation window displays. 2. Click to change the mode from View to Modify. 3. Make sure DKC is selected in the Display box. The - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 90
be performed on both the primary storage system and secondary storage systems. To delete the logical path between the primary and secondary storage system "Network relay devices" refers to hardware used for connecting the primary and secondary systems, such as channel extenders, and switches. 90 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 91
system, contact your HP account team and ask them minutes after powering on a system before performing Continuous Access Journal operations; otherwise the pairs resume copy operations, on the primary storage system, restore the pairs that have Manage power-off for systems and network devices 91 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 92
CAUTION: Wait five (5) minutes after powering on a system before performing Continuous Access Journal operations; otherwise the pairs could be suspended with status at primary system is PSUS and a status of a pair of secondary storage system is PAIR, use Remote Web Console to suspend the pair of the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 93
the horctakeover command executes successfully, your business operations are taken over to (or your business application is started at) the secondary site using the S-VOLs. For detailed information about RAID Manager and horctakeover, see HP StorageWorks P9000 RAID Manager User Guide. Preparing for - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 94
operational. 4. Do all of the following, as applicable: 1. At the primary site, locate P-VOLs whose VOL status is SSWS, execute the pairresync -swaps command. This reverses P-VOLs and S-VOLs and resynchronizes the at the primary site by using RAID Manager. 1. At both Continuous Access Journal - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 95
host read/write activity. Resume applications at the primary site. 7. Execute the pairresync -swaps command, which reverses P-VOLs and S- storage systems, resume the business tasks on the secondary site. For information on how to use RAID Manager, see HP StorageWorks P9000 RAID Manager User Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 96
" (page 97) • "Recovering from primary site disaster in 3DC multitarget configuration" (page 97) • "Recovering from primary site failures (when delta resync operation is performed)" (page 99) • "Recovering from failures in the primary site and the Continuous Access Synchronous secondary - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 97
Synchronous configuration to multitarget. These procedures are described in the following sections. To transfer business operations to the secondary site 1. Check consistency of the Continuous Access Synchronous S-VOL in the intermediate site. 2. Use RAID Manager to execute the horctakeover command - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 98
will be the primary volume. To change the system into 3DC multitarget configuration: 1. Use RAID Manager to release the former Continuous Access Journal pair. 2. If pair resynchronization has not been performed to reverse the primary/secondary relationship of a Continuous Access Synchronous pair - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 99
Journal pair, which extends between the Continuous Access Synchronous secondary site and the Continuous Access Synchronous secondary site. 2. Stop business tasks at the Continuous Access Synchronous secondary site. 3. Use RAID Manager to execute the horctakeover command on the Continuous Access - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 100
Synchronous secondary site to primary site (when delta resync operation is performed in 3DC multitarget configuration) To transfer your business tasks back to the primary site, follow the procedure below. RAID Manager (RAID Manager) is used in this procedure: 1. If the Continuous Access Synchronous - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 101
configuration (see "Recovering from primary site failures (when delta resync operation is performed problem, see the following table, check the pair status and then perform a problem extends RAID Manager (RAID Manager) is used in this procedure: 1. Use RAID Manager to execute the horctakeover command - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 102
command on the Continuous Access Journal pair. The Continuous Access Journal primary and secondary volumes are reversed. 5. Use the primary volume in the primary site to resume business tasks. 6. Use RAID Manager to resynchronize the Continuous Access Synchronous pair. The system configuration - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 103
site. Recovery with Business Copy configuration If disaster or failure occurs at using RAID Manager: 1. Release the Business Copy pair using the pairsplit -S command. perform copying in the original direction. Use the paircreate command. 8. Split the Business Copy pair using the pairsplit -r command - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 104
Access Journal follows. Table 15 General troubleshooting Error Remote Web Console hangs, or Cnt Ac-J operations do not function properly. Corrective action Make sure that the problem is not being caused by the computer or Ethernet hardware or software, and restart the computer. Restarting the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 105
Monitoring Switch to Enable again. For further information on Monitoring Switch, see HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. Troubleshooting logical paths Troubleshooting information for logical paths between storage systems is shown below. Table 16 Logical path - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 106
Table 16 Logical path troubleshooting (continued) Path status Serial Number Mismatch Description Corrective primary and secondary system ports are correct. Invalid Port Mode The specified port is not configured as an initiator port, or this path already exists. Make sure that the topology - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 107
Add Path or Add DKC command. Troubleshooting suspended pairs Troubleshooting information for user-suspended and system-suspended pairs the DKC Status dialog box (see "Troubleshooting logical paths " (page 105)). Clear any error conditions at the secondary storage system and the S-VOL. If you need - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 108
storage system. The primary storage memory during the IMPL procedure. This system performs an initial copy operation in error occurs only if the primary storage ) . If a failure occurs during execution of the RAID Manager horctakeover command, secondary volumes in SSWS pair status may remain in the - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 109
. An SVP error code may also be included. See HP StorageWorks P9000 Remote Web Console Messages for details on error codes. If you need to call HP Technical Support for assistance, report the error code(s). Troubleshooting using RAID Manager When an error has occurred in Continuous Access Journal - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 110
is shown below. Table 19 RAID Manager error codes for Continuous Access not support the corresponding command. A configuration, the Cnt Ac-J pair cannot be created when the Continuous Access Synchronous is in existence. Also, the 3DC multitarget configuration cannot be created. 110 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 111
on the remote storage system does not support the LUSE volume. The secondary systems. Therefore the command was rejected because the external volume. The Cnt Ac-J pair cannot be created because the specified volume is part of a Business Copy or Flash Copy pair. Troubleshooting using RAID Manager - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 112
Table 19 RAID Manager error codes for Continuous Access Journal specified volume was the P-VOL of the Continuous Access Synchronous. • The unavailable configuration with the combination of the Business Copy (including when the mirror ID of specified volume was blocked. 112 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 113
, because Continuous Access Journal was not installed. The source of command devise has run out. Set to OFF the command device and to ON again from the LUN Manager. Cnt Ac-J Paircreate cannot be performed because the specified device is a command device. Troubleshooting using RAID Manager 113 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 114
DB02 DB03 DB07 Error content Cnt Ac-J Paircreate cannot be performed because the mirror ID is invalid. The command was rejected because the volume status was SMPL. The S-VOL hide mode is not supported. Cnt Ac-J Paircreate cannot be performed because the Cnt Ac-J program product is not installed - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 115
resync mode) was rejected because the specification was volume instead of group. A Access Synchronous combination (2DC) configuration in the intermediate site. An Paircreate was rejected because the path between the storage devices for the both-way was not Troubleshooting using RAID Manager 115 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 116
Table 19 RAID Manager error codes for Continuous Access Journal ( number. A request of Cnt Ac-J Paircreate was rejected because the path between the storage devices for the both-way was not defined. Check whether the bidirectional normal path retry the registration again. 116 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 117
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) E8A6 E8A7 E8A8 E8A9 E8B6 E8F7 pair status was not PSUS. A request of Cnt Ac-J Pairresync was rejected because the state of journal was not Stopped. Troubleshooting using RAID Manager 117 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 118
Table 19 RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EA1B EA1C EA1E EA20 EA22 EA25 EA29 pair for the system that consists of multiple primary and secondary systems was rejected because the microcode was being replaced. 118 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 119
rejected because the specified P-VOL or S-VOL is in the process of having the capacity changed by Thin Provisioning. The Cnt Ac-J pair cannot be deleted because the specified Cnt Ac-J volume is used as the Cnt Ac-J pair is the status other than PAIR or SUSPEND. Troubleshooting using RAID Manager 119 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 120
RAID Manager and Continuous Access Synchronous combination (2DC configuration). A delta resync pair cannot be rejected because the secondary system did not support the delta resync function. A pair in the storage system. Please check the status of the volume. The command was rejected Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 121
RAID Manager horctakeover (resync) command was executed. The Cnt Ac-J pair create processing was doubly executed: • There are no problems if the initial copy operation is restarted when the primary storage the system disk. A request VOL is an external volume. The Troubleshooting using RAID Manager 121 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 122
RAID Manager error codes for Continuous Access Journal (continued) Error code (SSB1) Error code (SSB2) EB80 EB87 EB88 Error content The command hard disk drive configuration of the P-VOL is different from the LUSE configuration Provisioning. • Releasing the page of Thin Provisioning Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 123
HP StorageWorks P9000 Remote Web Console User Guide, or call HP Technical Support for assistance. The figure below shows a typical 32-byte SIM from the system. The six-digit reference code consists of bytes 22, 23, and 13. The reference code identifies the possible error and determines the Service - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 124
the problem. All SIMs are reported to the host, except 21 80. Table 20 SIM reference codes, types, and descriptions Reference code system Service Logical path is restored. Primary system/Secondary system Moderate Line failure is reported by the extender. Primary system. 124 Troubleshooting - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 125
Reference storage been suspended. system A failure has been detected in the primary storage system. DC AX Serious A volume used in a P-VOL that is Primary storage SIM Log configured to OFF. Miscellaneous troubleshooting Suspension among journals • If you use RAID Manager and if a journal is - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 126
External Storage for Open and Mainframe Systems User Guide • HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide • HP StorageWorks P9000 Provisioning for Mainframe Systems User Guide • HP StorageWorks P9000 Provisioning for Open Systems User Guide • HP StorageWorks P9000 RAID - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 127
hp.com/support/manuals • http://www.hp.com/support/downloads • http://www.hp.com/storage/whitepapers Conventions for storage capacity values P9000 disk arrays use the following values to calculate physical storage capacity values (hard disk http://www.hp.com Bold text Element Cross-reference links - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 128
or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. HP product documentation survey Are you the person who installs, maintains, or uses this HP storage product? If so, we would like to - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 129
"Continuous Access Journal configurations with Continuous Access Synchronous" (page 134) "Continuous Access Journal configurations with Business Copy" VOL in PSUS status Yes S-VOL (none of the above) No Reserved volume No Snapshot P-VOL in COPY(RS-R) status No P-VOL that is also used as a - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 130
Cache Residency The volume that is set Cache Residency Virtual LUN Virtual LUN volume LUN Manager Volume to which a path is defined Volume to which no path is defined Volume to which LUN security is applied Thin Provisioning Can the volumes be used as P-VOLs? Yes No No Yes*5 Yes*5 Yes*5 No - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 131
volumes' status returned to SMPL. For more information about LUSE, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. Virtual LUN • Continuous Access Journal supports the Virtual LUN feature, which allows you to configure custom-size LU that are smaller than standard-size LUs. When - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 132
• You can create a Continuous Access Journal pair by specifying V-VOL (Thin Provisioning virtual volume). • V-VOLs can be either the Continuous Access Journal P-VOL or S-VOL, or both P-VOL and S-VOL. • V-VOLs cannot be used for Continuous Access - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 133
Access Journal operations are completed, exit Continuous Access Journal and Remote Web Console. 5. Re-enable Performance Monitor data collection. For more information on Performance Monitor, see HP StorageWorks P9000 Performance for Open and Mainframe Systems User Guide. Performance Monitor 133 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 134
configurations with Continuous Access Synchronous Continuous Access Journal and Continuous Access Synchronous can share the same data volumes. Using Continuous Access Journal and Continuous Access Synchronous can extend solution at a remote site. • In a 3 Data Center multitarget configuration - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 135
"Recovery in a 3DC cascade configuration " (page 97) for recovery information and procedures. Prerequisite information for 3DC cascade • P9500 must be installed at the local, Continuous Access Synchronous intermediate, and Continuous Access Journal remote sites. • RAID Manager is recommended at all - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 136
is not supported for multiple primary configuration 1. Install and setup Continuous Access Synchronous and Continuous Access Journal on the required systems. 2. Create the Continuous Access Synchronous pair on the primary system. See HP StorageWorks P9000 Continuous Access Synchronous User Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 137
disaster in 3DC multitarget configuration" (page 97) for recovery information and procedures. Prerequisite information for 3DC multitarget • P9500 must be installed at the local, Continuous Access Synchronous intermediate, and Continuous Access Journal remote sites. • RAID Manager is recommended at - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 138
. See HP StorageWorks P9000 Continuous Access Synchronous User Guide for instructions. 3. When Continuous Access Synchronous pair status is PAIR, create the Continuous Access Journal pair on the primary system. The mirror ID must be set between 1 and 3. Delta resync configuration In a Continuous - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 139
configuration only. • Do not include the 3DC multitarget configuration in a system that consists of multiple primary and secondary storage the pair status after executing the RAID Manager horctakeover command. • The secondary data volume operation to support remote command devices is performed, you - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 140
pair or Continuous Access Journal pair, allow the 3DC configuration to remain status for at least 5 minutes before you execute any other continuous access-related commands. If the delta resync operation to support remote command devices is performed, you can execute the delta resync operation after - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 141
command devices. Configure paths between external ports and target ports. For detail about the external ports, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. For instruction on setting paths, see HP StorageWorks P9000 Provisioning for Open Systems User Guide - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 142
site should also have two remote command devices mapped to via external ports from the other two sites. The following figure shows the command/remote command device configuration. Figure 23 Remote command device configuration for delta resync When mapping to remote command devices on each site is - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 143
remote command device by selecting Journal > Release R-Cmd. Dev when you right-click the mirror. Release a remote command device which is assigned to a mirror Prerequisites To release a remote command device which is assigned to a mirror, perform this operation per mirror. Delta resync configuration - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 144
command device is not assigned, the column of the remote command device is blank. Perform the delta resync operation The delta resync operation is performed V-VOLs, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. 144 Continuous Access Journal configurations with Continuous Access - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 145
is not connected to a host, a remote command device is required. See HP StorageWorks P9000 RAID Manager User Guide for more information. • Remote Web Console is required at all sites. • The primary site requires the following: ◦ Host application ◦ Continuous Access Synchronous ◦ Continuous Access - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 146
is PAIR, create the Continuous Access Synchronous pair on the primary system. See HP StorageWorks P9000 Continuous Access Synchronous User Guide. 5. Confirm that Continuous Access Synchronous pair status becomes PAIR. 146 Continuous Access Journal configurations with Continuous Access Synchronous - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 147
configurations and information for using Business Copy with Continuous Access Journal. For details about Business Copy, see HP StorageWorks P9000 Business Copy User Guide volume is available for continuous replication during a test. ◦ If a Continuous Access Journal problem is encountered during an - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 148
and Business Copy primary volume • A Continuous Access Journal secondary volume shared with the Business Copy primary volume is illustrated below. With this configuration, multiple backup copies of the Continuous Access Journal primary volume can be made on the remote system. CAUTION: When you share - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 149
with Business Copy primary volumes Configurations with Business Copy secondary volumes must be in PSUS status (Split) to perform the Continuous Access Journal operation. Figure 28 check status of the primary volume. Business Copy supports multiple secondary volumes for each primary volume. When you - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 150
lowest LDEV ID. To see status for the pairs with a different secondary volume, direct a host query to the specific secondary volume using the secondary volume's LDEV ID in the host command. 150 Continuous Access Journal configurations with Business Copy - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 151
D Continuous Access Journal GUI reference This appendix describes the Continuous Access Journal windows, dialog boxes, fields, and behaviors in Remote Web Console. Journal Operation window This window allows you to view details about journals and volumes. Information on the Journal Operation window - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 152
which no journal volumes are registered. For instructions on how to register journal volumes in journals configuration by using Cnt Ac-J and Cnt Ac-S (for example, 01 (00) [&]). • Attribute: Indicates the attribute of a mirror in the local storage system. 152 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 153
controller ID (name indicating the model) of the remote storage system. The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array is 4. This column is blank if the attribute - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 154
before the changes are applied to storage systems. If you are sure that perform only the same type of operation that you have been doing and cannot perform most of other operations (you can only view a remote command device to a mirror • Release R-Cmd.Dev: Release an assigned remote command device - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 155
a 2DC configuration, for Manager horctakeover command is used to change a master journal into a restore journal, this setting takes effect on the journal. If you set Use, this setting only takes effect on the journal volumes of RAID-5 or RAID-6 that are in the journal. For external volumes, non RAID - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 156
(model name that indicates the model) of the remote storage system. The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array is 4. This column is blank if the attribute of - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 157
Item Next Close Description Displays detailed information about the next journal. Closes the Journal Detail dialog box. Change Journal Option dialog box This dialog box lets you change the options that affect pairs in a journal. See "Change Continuous Access Journal options used by journals " ( - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 158
split (suspended) immediately after a path gets blocked, ask the HP Technical Support to set system option mode 448 to ON and set system option that takes place when the delta resync operation cannot be performed-entire P-VOL is copied or no processing (S-VOL not Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 159
• PG: Shows volumes belonging to a parity group. • PG(Ext.): Shows external volumes belonging to a parity group. • CU: Shows volumes belonging to a CU Define the function of the journal used in the 2DC cascade configuration of Continuous Access Journal and Continuous Access Synchronous. This option - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 160
File > Refresh on the menu bar. • Select Modify mode when you are in View mode. Use the Pair Operation window to: • "Create the initial copy " ( Filter Export Previous/Next Description Lists the ports in the local storage system, with host groups displaying below each port. Selecting a reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 161
volume, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. A device ID ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. For details on a virtual volume, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. To - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 162
storage system is a secondary storage system. A device ID ending in X (for example, 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. A device ID ending in # (for example, 00:00:3C #) indicates the LDEV is an external volume. If a volume is a volume of XP24000/XP20000 Disk Array - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 163
the following cases, this column will be blank: - When the volume in the local storage system is neither a P-VOL nor a S-VOL. - When the status of the volume can perform only the same type of operation that you have been doing and cannot perform most of other operations (you can only view detailed - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 164
, if Preview 010/8192 appears, you can add another 8,182 items to the Preview list. Applies settings in the Preview list to the storage systems. Cancels settings in the Preview list. Information in the VOL Column Information in The Paired VOL Column Detailed Information dialog box This dialog - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 165
and changes P-VOL status accordingly. On the primary side. when a Cnt Ac-J operation is performed, the primary system changes the pair status of both P-VOL and S-VOL. If the volume in the local storage system is a P-VOL, Sync shows the percentage of synchronization between P-VOL that and S-VOL - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 166
3C #) indicates the LDEV is an external volume. • If there is no volume in the local storage system, the S-VOL's port ID, GID, and LUN display. Do not change or delete this information. • "00" appears for the LDKC number if the volume is a XP24000/XP20000 Disk Array volume. • For volumes shared with - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 167
Item Previous/Next Refresh Close Description Clicking Previous shows the pair status information for the previous pair in the list (the pair in the row above). Clicking Next shows the pair status information for the next pair in the list (the pair in the row below). The list shows a maximum of 2, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 168
, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. A device ID ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. For details on a virtual volume, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. 168 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 169
data on the P-VOL is copied to the S-VOL. • None: The initial copy operation does not start after the volume pair is created. The primary storage system starts copying of update data as needed. Ensure that the P-VOL and S-VOL are already identical when using None. • Delta: No initial copy operation - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 170
that you have set with the Priority parameter. The time out error may be caused by the CU configuration or a remote copy path error. Review the error, release the pair with the error, and then retry "Split a pair " (page 57) for complete information. 170 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 171
frequency of host I/Os. The suspend pair operations should be performed under light I/O load conditions. If the following two conditions you split the pair, update data is copied to the S-VOL. When the secondary storage system receives a request for splitting a pair, all the journal data (that is, - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 172
cannot change the Priority option. Indicates the followings about a remote storage system. • The serial number with the LDKC number. • The is PSUS or PSUE is recovered. • Delta: Delta resync operation is performed. • Return to standby: The status of pairs is recovered from HLDE Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 173
not from frequency of host I/Os. The pair operations should be performed under light I/O load conditions. • Mirror: All pairs in the Normal: The pair(s) is be released only if the primary storage system is able to change the pair status of the primary and instructions. Pair Operation window 173 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 174
Pair Operations window. Item GID Journal Mirror P-VOL/S-VOL CLPR Internal/External VOL Status Reset Description The host group's Group ID. All shows All, all CLPRs display in the list Whether internal volumes or external volumes display. All shows both kinds of volumes The pair status or - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 175
bar. • Select Modify mode when you are in View mode. Use the DKC Operation window to: • "Configure storage systems for Continuous Access Journal, define logical paths " (page 45) • "Configure additional logical paths " (page 47) • View one of the following: ◦ "Remote Systems Information " (page - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 176
"DKC" to indicate a storage system. LDKC is an acronym for logical disk controller, and it also may be called logical DKC. LDKC is a controller that controls a logical storage system that exists in P9500. In the Cnt Ac-J window and the LDKC in the tree. 176 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 177
ID and the model name of the storage system of a remote storage system. The controller ID for a P9500 storage system is 6. The controller ID for a XP24000/XP20000 Disk Array storage system is 5. The controller ID for a XP12000 Disk Array/XP10000 Disk Array is 4. The icon indicates the status of - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 178
between the local storage system and the remote storage system. This column viewed in the "DKC Status dialog box " (page 179). The port number of the local storage system. The port number of the remote storage list shows all the ports on the local storage system. • Select a channel adapter. The list - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 179
on the local storage system: • Port: Port number. • Attribute: Port attribute (i.e., initiator, target, RCU target, or external) • PCB Mode: Mode of the port. The mode is either Standard, or High. • Error Code: An error code. DKC Status dialog box This dialog box lets you view status and other - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 180
Item No Path Status Description Number of the row. 180 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 181
path to the remote system was performed. When clicked, the DKC Operation window refreshes when it redisplays. Add DKC dialog box This dialog box lets you configure local and remote systems for Continuous Access Journal pairs. See "Configure storage systems for Continuous Access Journal, define - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 182
LDKC number, 00 for XP24000/XP20000 Disk Array. Remote system controller ID, 6 for P9500, 5 for XP24000/XP20000 Disk Array, 4 for XP12000 Disk Array/XP10000 Disk Array. Field intended for a future release. threshold " (page 89) for complete information. 182 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 183
. The most recent data sample time of data on the graph. Remote I/O statistics and status of remote copy monitor. History window This window lets you view the history of operations performed on pairs, and the data associated with each operation. Usage Monitor window 183 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 184
. Save operation history in a text file after operation history is updated. For more information, see "Export operations history " (page 187). 184 Continuous Access Journal GUI reference - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 185
, see HP StorageWorks P9000 External Storage for Open and Mainframe Systems User Guide. A volume ending in X (e.g., 00:00:3C X) indicates the LDEV is a Thin Provisioning virtual volume. For details on a virtual volume, see HP StorageWorks P9000 Provisioning for Open Systems User Guide. • Paired - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 186
storage system. The status of storage system. An operation for releasing a pair has been started at the secondary storage started at the secondary storage system. The status of a pair finished at the secondary storage system. A pair became ready storage system. The status of the pair - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 187
CU number and LDEV number of the volume in the remote storage system (LDKC : CU : LDEV). (7) Extended consistency group number (used only with Continuous Access Journal Z). If number of volumes on which the initial copy operation is performed concurrently. • Click Apply • Select another tab and then - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 188
View mode. Item Tree Activities Preview Operation Preview Apply Cancel Description Provides access to the storage system. Select Subsystem. Storage to the storage system. Clicking Apply applies the changes to the storage system. • Change System Option: Change storage system options. • Blank: - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 189
software. This is the version of Continuous Access Synchronous that supports mainframe volumes. See Cnt Ac-S for more information. A volume in the disk array that accepts HP StorageWorks Continuous Access, HP StorageWorks Business Copy, or HP StorageWorks P9000 Business Continuity Manager - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 190
referred to as a Array Group or RAID Group. The CLI configuration and replication tool for the P9000 or XP disk array that can be used by system administrators to enter RAID Manager commands from open-system hosts to perform TrueCopy, ShadowImage, Data Integrity Check operations, and provisioning - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 191
, 62 performing the operation, 144 Delta resync configuration, 138 delta resync operation environment configuring for remote command devices, 141 direct connection, graphic, 41 disaster recovery general procedures, 93 in 2DC config;, 102 in 3DC cascade config, 97 disk arrays supported models - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 192
site recovery resuming operations, 94 with 2DC configuration, 102 PSUE, 72 PSUS types, 71 R RAID groups, planning, 24 RAID levels supported, 18 RCU target port, 39 related documentation, 126 remote command device about, setup;delta resync:using remote command devices with, 141 assigning mirrors, 142 - HP StorageWorks P9000 | HP StorageWorks P9000 Continuous Access Journal User Gui - Page 193
requirements, 17 T target port, 39 technical support HP, 126 service locator website, 126 text symbols, 128 Thin Provisioning, 130, 132 tracking journal data, 71 typographic conventions, 127 V Volume Types, 129 W websites HP , 126 HP Subscriber's Choice for Business, 126 product manuals, 126 193
HP StorageWorks
P9000 Continuous Access Journal User
Guide
Abstract
This guide explains how to use HP StorageWorks P9000 Continuous Access Journal Software to replicate data between local
and remote HP StorageWorks P9000 disk arrays and to achieve disaster tolerance with maximum application performance.
Topics include setting up remote copy connections, configuring the storage system, creating and monitoring remote copies,
recovering from a disaster, and troubleshooting. The intended audience is a storage system administrator or authorized service
provider with independent knowledge of HP StorageWorks P9000 disk arrays and the HP StorageWorks Remote Web Console.
HP Part Number: AV400-96349
Published: January 2011
Edition: Third