HP StorageWorks HP StorageWorks SB40c Storage Blade Maintenance and Service Guide doc-number Part number: 433903-002 Third edition: April 2009 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 2
to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 3
-MB cache module 23 Mainboard subchassis and midplane 24 Light pipe bezel ...25 HDD rails ...26 HP Smart Array P400 Controller 26 Replacing the chassis ...27 Chassis ...27 5 Diagnostic tools 29 Integrated Management Log ...29 Array Diagnostic Utility ...29 HP StorageWorks SB40c Storage Blade 3 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 4
6 Component identification 31 Front panel components ...31 Front panel LEDs ...31 SAS and SATA device numbers 32 SAS and SATA hard drive LEDs 32 SAS and SATA hard drive LED combinations 33 7 Specifications 35 Environmental specifications ...35 Storage blade specifications ...35 4 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 5
Figures 1 Partnered with a half-height server blade 20 2 Partnered with a full-height server blade 20 HP StorageWorks SB40c Storage Blade 5 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 6
Tables 1 Document conventions 7 6 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 7
to follow directions could result in bodily harm or death. CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. HP StorageWorks SB40c Storage Blade 7 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 8
(CSR) programs allow you to repair your StorageWorks product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 9
/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. HP StorageWorks SB40c Storage Blade - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 10
10 About this guide - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 11
of parts only warranty service, HP will provide replacement parts free of charge. For parts only warranty service, CSR part replacement is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. HP StorageWorks SB40c Storage Blade 11 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 12
12 Customer self repair - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 13
Item Description Spare part number Customer self repair 1 HP Smart Array P400 Controller 256-MB cache module 405836-001 Mandatory 2 HP Smart Array (with subchassis) and midplane 430798-001 Optional 6 Hard drive blank 392613-001 Mandatory HP StorageWorks SB40c Storage Blade 13 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 14
-001 Mandatory 10 Chassis Spare Part Kit 572028-001 Optional *: Not Known Mandatory: Parts for which customer self repair is mandatory. If you request HP to replace these parts, you will be charged for the travel and labor costs of this service. Optional: Parts for which customer self repair - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 15
electrical energy, do not remove the SB40c access panel and then install the SB40c into the enclosure. WARNING! WARNING: To reduce the risk of personal injury from hot surfaces, allow the drives and the internal system components to cool before touching them. HP StorageWorks SB40c Storage Blade 15 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 16
to leave the SB40c powered up when performing other operations, such as hot-plug installations or troubleshooting. Symbols on equipment upgrades, and servicing to qualified personnel. This symbol indicates the presence of electric shock hazards. The area contains no user or field serviceable parts - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 17
multiple sources of power. WARNING! To reduce the risk of injury from electric shock, remove all power cords to completely disconnect power from the system. HP StorageWorks SB40c Storage Blade 17 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 18
18 Removal and replacement procedures - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 19
. Remove the SB40c 1. Identify the proper SB40c. 2. Power down the partner server blade. 3. If the SB40c partner server blade is a full-height server blade, remove the blank or the half-height server blade installed above the SB40c. 4. Remove the SB40c: HP StorageWorks SB40c Storage Blade 19 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 20
. CAUTION: To prevent damage to electrical components, properly ground the SB40c before beginning any installation procedure. Improper grounding can cause ESD. Remove the access panel To remove the component: 1. Power down the partner server blade. 2. Remove the SB40c. 20 Storage blade preparation - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 21
drive blank 1. Remove the hard drive blank. 2. Replace the component by reversing the removal procedure. Hard drive 1. Determine the status of the hard drive from the hot-plug SAS hard drive LED combinations. 2. Back up all server data. 3. Remove the hard drive. HP StorageWorks SB40c Storage Blade - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 22
contacts. • Replace the battery pack only with the designated HP spare. • Battery disposal should comply with local regulations. To remove the component: 1. Power down the partner server blade. 2. Remove the SB40c. 3. Remove the access panel. 4. Remove the battery pack. 22 Storage blade preparation - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 23
procedure. HP Smart Array P400 Controller 256-MB cache module To remove the component: 1. Power down the partner server blade. 2. Remove the SB40c. 3. data from the server or transfer data to another server. 5. Remove the cache module from the controller. HP StorageWorks SB40c Storage Blade 23 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 24
partner server blade. 2. Remove the SB40c. 3. Remove all hard drive blanks. 4. Remove all hard drives. 5. Remove the access panel. 6. Remove the mainboard subchassis. 7. Remove the midplane and midplane bracket. NOTE: Be careful not to damage wire for light pipe LEDs by sharp edge. 24 Storage blade - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 25
the SB40c. 3. Remove all hard drive blanks. 4. Remove all hard drives. 5. Remove the access panel. 6. Remove the mainboard subchassis and midplane 7. Remove the center cage cover (1) and the light pipe bezel (2) by pulling in the direction of the arrow (3). HP StorageWorks SB40c Storage Blade 25 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 26
cage cover and the light pipe bezel. 9. Remove HDD rails. 10. Replace the component by reversing the removal procedure. HP Smart Array P400 Controller To remove the component: 1. Power down the partner server blade. 2. Remove the SB40c. 3. Remove all hard drive blanks. 26 Storage blade preparation - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 27
all hard drives. 5. Remove the access panel. 6. Remove the mainboard subchassis and midplane. 7. Remove the light pipe bezel. 8. Remove the center cage cover. 9. Remove HDD rails. 10. Chassis is now disassembled and prepared for user serviceable chassis swap. HP StorageWorks SB40c Storage Blade 27 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 28
11. Replace the component by reversing the removal procedure. 28 Storage blade preparation - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 29
ProLiant Essentials Foundation Pack. Array Diagnostic Utility ADU is a tool that collects information about array controllers and generates a list of detected problems. ADU can be accessed from the SmartStart CD or downloaded from the HP website http://www.hp.com. HP StorageWorks SB40c Storage Blade - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 30
30 Diagnostic tools - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 31
6 Component identification Front panel components Item 1 2 Front panel LEDs Description Serial pull tab Storage blade handle HP StorageWorks SB40c Storage Blade 31 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 32
Blue = Identified 1 Off = Not identified Green = Normal operation 2 Flashing amber = Degraded condition Flashing red = Critical condition 3 - 4 - SAS and SATA device numbers SAS and SATA hard drive LEDs Item Description 1 Fault/UID LED (amber/blue) 32 Component identification - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 33
loss, do not replace the drive until the expansion or migration is complete. Flashing regularly (1 Hz) Off Amber, flashing regularly (1 Hz) Flashing irregularly Flashing irregularly Off Off Steadily amber Off Amber, flashing regularly (1 Hz) Off Off HP StorageWorks SB40c Storage Blade 33 - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 34
34 Component identification - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 35
type and number of options installed. Non-operating 9144 m (30 storage corresponds to a pressure minimum of 70 KPa. ‡ Maximum allowable altitude change rate is 457 m/min (1500 ft/min). Storage blade specifications Specification Height Value 5.56 cm (2.19 in) HP StorageWorks SB40c Storage Blade - HP StorageWorks SB40c | HP StorageWorks SB40c Storage Blade Maintenance and Serv - Page 36
Specification Depth Width Weight (maximum) Weight (no drives installed) Value 50.95 cm (20.06 in) 18.16 cm (7.15 in) 5.0 kg (11.0 lb) 3.6 kg (8.0 lb) 36 Specifications