- HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 1
HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide Part Number: 5697-0261 Published February 2010 Edition: 1 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 2
services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors or omissions contained herein. QuickTools™ is a trademark of QLogic , Inc. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 3
HP technical support 11 Subscription service 11 HP-authorized reseller 11 Helpful websites 12 1 Using QuickTools 13 Workstation requirements 13 Opening QuickTools 13 QuickTools user 36 Deleting a nickname 36 HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 3 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 4
database 43 Merge Auto Save 43 Default Zone 44 Discard Inactive 44 Saving Switch Stacks 56 Security Consistency Checklist 57 Managing user accounts 58 Creating user accounts 59 Removing a user account 59 Changing a user account password 60 Modifying a user account 61 Paging a switch - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 5
Tuning and AL Fairness 105 Resetting a port 105 Testing ports 105 Glossary 107 Index 111 Figures 1 Add a New Fabric dialog box 14 2 Password Change Required dialog box 14 3 QuickTools interface 15 HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 5 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 6
Account dialog box 60 25 User Account Administration-Change Password dialog box 60 26 User Account Administration-Modify Account dialog box 61 27 Date/Time dialog box 62 28 Switch Properties dialog box 64 29 Advanced Switch Properties dialog box 66 30 System Services dialog box 67 31 Network - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 7
72 15 SNMP v3 User Editor dialog box fields 75 16 Factory default configuration settings 79 17 Call Home Setup fields 84 18 Call Home Editor-Tech Support Center Profile dialog box Port transceiver media view 104 HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 7 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 8
8 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 9
and SN6000 Fibre Channel Switch CIM Agent Reference Guide For the latest product information, including firmware, documentation, and supported SAN configurations, see the following HP website: http://www.hp.com/go/SN6000. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 10
blue text: Figure 1 Medium blue, underlined text (http://www.hp.com) Bold font Italics font Monospace font Monospace, italic font Monospace equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 11
the name of your nearest HP-authorized reseller: • In the United States, call 1-800-282-6672. • Elsewhere, visit the HP website: http://www.hp.com. Then click Contact HP to find locations and telephone numbers. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 11 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 12
Helpful websites For other product information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.docs.hp.com 12 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 13
Environment 1.4.2 to support the web switch IP address (the default switch IP address is 10.0.0.1). (If your workstation does not have the Java 2 Run Time Environment program, you will be prompted to download it.) HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 14
user account password that was initially set up by the administrator (Figure 2). Figure 2 Password Change Required dialog box NOTE: Until you change the default password, you will be prompted to change the password the switch names. Click a switch name or icon to display a different switch faceplate - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 15
(Figure 3) displays a table of data and statistics associated with the selected tab for the switch displayed in the graphic window. Use the scroll bar to browse through the data. To and tabs are described below: HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 15 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 16
the switch. See "Devices data window" on page 34 for more information. • Switch-Displays current network and switch configuration data for the selected switch. See "Switch data window -and-drag the divider bar to manually move it up or down. Status section Figure 4 Alerts panel 16 Using QuickTools - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 17
Switch Diagnostics, Offline Switch Diagnostics (available on entry switch only)) Toggle Beacons Load Firmware Reset Switch (Hot Reset, Reset, Hard Reset) Restore Factory Defaults Features Download Support File HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 18
User Accounts Security Consistency Checklist Reset ((Hot Reset, Reset, Hard Reset) Load Firmware Move Switch Up (available when a switch (except top switch) in stack is selected) Move Switch Down (available when a switch (except bottom switch Deactivate Zoneset Restore Default Zoning Refresh View - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 19
-sensitive. Shortcut keys are not supported on the Mac platform. Selecting switches To select a switch, you can either select the switch name or switch icon from the fabric tree to to open a non-secure fabric and HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 19 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 20
have the option of opening the non-secure fabric. If this option is disabled, you cannot open a fabric that has a non-secure connection. • Enable (default) or disable the Event Browser. See "Event Browser" on page 31 for more information. If the Event Browser is enabled using the Preferences dialog - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 21
Exiting QuickTools To exit a QuickTools web applet session, close the browser. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 21 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 22
22 Using QuickTools - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 23
fabric If there are no special conditions to be configured for a new switch, plug in the switch; the switch becomes functional with the default fabric configuration. The default fabric configuration settings are: HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 23 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 24
or later is required for the HP SN6000 Fibre Channel Switch. SSCM version 2.0 and earlier versions do not support the management of fabrics that include switches with active TR_Ports and may disrupt communication between an HP SN6000 or 8/20q Fibre Channel Switch and the remote fabric. 24 Managing - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 25
(RSCNs). The TR_Port uses FDISCs to login proxies for devices attached to an N_Port on the HP SN6000 Fibre Channel Switch. Any of the HP SN6000 Fibre Channel Switch 8Gb ports may be configured as a TR_Port. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 25 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 26
C-series switches do not support the devices to be mapped and the WWNs of the HP SN6000 Fibre Channel Switch TR ports are zoned together. For more information, see If there is no active zone set, a zone set named TR_MAPPING_SET" (default name) is created, the new IFZs are added to the zone set - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 27
multiple TR ports, as long as each of those TR ports are on different HP SN6000 Fibre Channel Switches. Select a local device from the 1 Select a Local Device column to display and close the Add TR Mapping dialog. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 27 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 28
activated. If there is no active zone set, a zone set named TR_MAPPING_SET" (default name) is created, the new IFZs are added to the zone set, and then to generate for the user. Fabrics with B-series and C-series switches are supported. NOTE: Before modifying zoning, HP recommends that you back up - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 29
name as needed. The default Configuration Name displayed is switches assume that zoning will be applied to VSAN 1. If this is not the correct VSAN, you must edit the commands accordingly before executing the commands. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 30
current TR mapping state (Active or Inactive) • Active-Indicates that the mapping's TR port is on this switch, and both devices have logged in. • Inactive-Indicates that the mapping's TR port is on this switch, and the mapping is not active. The reasons are shown in the details display as the three - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 31
started all events from the switch log appear. If the Event Browser is disabled when QuickTools is started and later enabled, only those events that occur after the time the Event Browser was enabled will appear. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 31 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 32
Alarm-An alarm is a "serviceable event." This means that attention by the user or field service is required. Alarms are posted support file from the switch. Critical event-An event that indicates a potential failure. Critical log messages are events that warrant notice by the user. By default - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 33
order based on the event severity, timestamp, source, type, or description. By default, the Event Browser is sorted in ascending order by timestamp. To sort on type alternate between ascending and descending order. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 33 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 34
. CSV files can be opened with most spreadsheet applications. Device information and nicknames Devices are hosts and storage targets connected to the switch. A nickname is a user-definable, meaningful name that can be used in place of the World Wide Name (WWN). This sub-section describes how to view - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 35
a user-definable, meaningful name that can be used in place of the World Wide Name. Assigning a nickname makes it easier to recognize device ports when zoning your fabric or when viewing the Devices data window. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 35 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 36
workstations. The maximum number of nicknames allowed is 5,000. Nicknames are saved to an XML file stored on the switch. If different nickname files exist on other switches in the fabric, you are prompted to resolve differences before the Nicknames dialog box is displayed. When a conflict exists - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 37
membership for the active zoneset that resides on the fabric management switch. The active zoneset is the same on all switches in the fabric. To open the Active Zoneset data window, 15 Active Zoneset data window HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 37 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 38
to show its members by device port World Wide Name or device port Fibre Channel address. • The alias expands to show its entries. Figure 16 , that port behaves as a soft zone member. Zoning is hardware enforced on a switch port if the sum of the logged-in devices plus the devices zoned with devices - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 39
be configured on the switch. • MaxZones-The maximum number of zones that can be configured on the switch, including orphan zones. • MaxAliases-The maximum number of aliases that can be configured on the switch. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 39 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 40
44 • Restoring the zoning database from a file, page 44 • Restoring the default zoning database, page 44 • Removing all zone and zoneset definitions, page 45 dialog box (Figure 17) to edit the zoning database of a particular switch. To open the Edit Zoning dialog box, open the Zoning menu and - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 41
expanding and contracting zonesets, zones, and ports. An expanded port shows the port Fibre Channel address; an expanded address shows the port World Wide Name. You can select to close the Error Check dialog box. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 41 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 42
to the clipboard Paste button-Pastes clipboard items in selected zoning item, where applicable Table 8 Port/Device icons Icon Description Switch port icon-When not logged in Switch port icon-When logged in NL_Port (loop) device icon-When logged in to fabric NL_Port (loop) device icon-When not - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 43
(Figure 18) to change the Merge Auto Save, Default Zone, and Discard Inactive configuration parameters. To open the switch firmware saves changes to the active zoneset in temporary memory and to the zoning database. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 44
restoring the zoning database to a file You can save the zoning database to an XML file, restore the saved database or the default zoning (which clears the switch of all definitions). You can also remove all zones and zoneset definitions. • Saving the zoning database to a file, page 44 • Restoring - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 45
devices as zone members. The zoning database supports multiple zonesets to serve the different security communication fabric-wide (when Default Zone is set to Allow) or no communication (when Default Zone is set to HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 45 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 46
a zone from a zoneset, page 48 • Removing a zone from all zonesets, page 48 Changes that you make to the zoning database are limited to the managed switch and do not propagate to the rest of the fabric. To distribute changes to configured zonesets fabric wide, you must edit the zoning databases on - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 47
dialog box. Adding zone members You can zone a port/device by switch domain ID and port number, device port Fibre Channel address, or the device port WWN. Adding a port/device to box, click the zone to be renamed. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 47 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 48
not propagate to the rest of the fabric. To distribute changes to configured zonesets fabric wide, you must edit the zoning databases on the individual switches. You will not see aliases in the active zoneset. Creating an alias To create an alias: 1. Open the Zoning menu, and select Edit Zoning to - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 49
digits for a WWN member, 4 digits for a Domain/ Port member (DDPP), or a 6-digit Fibre Channel Address for a First Port Address member (DDPPAA), where DD=domain ID, PP=port number, and information on zoning limits. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 49 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 50
Zone merge failure recovery When a zone merge failure occurs, the conflict that caused the failure must be resolved. You can correct a failure due to a zone conflict by deactivating one of the active zonesets or by editing the conflicting zones so that their membership is the same. You can - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 51
The Switch data window (Figure 19) displays the current network and switch information for the selected switch. To open the Switch data window, click the Switch tab below the data window. Figure 19 Switch data window HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 52
window is grouped and accessed by the Summary, Status, Network, User Login, Firmware, Services, Zones/Security, and Advanced buttons. Click a button to display the switch information for the selected data category (Figure 19). The Switch data window buttons are identified in Figure 20. Figure 20 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 53
enables switches to synchronize their time to a centralized server. The IP address of the centralized NTP server. Ethernet connection to NTP server is required. DNS Enabled Domain Name Service Enabled or Disabled HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 54
IPv6 addresses assigned by DHCP v6, NDP, or the switch administrator. User Login Group User Name Account name Login Level Authority level of the user name Super User UserAuthentication Enabled Firmware Group Super user privileges Enabled or Disabled. Enforcement of account names and authority - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 55
a switch that can donate buffer credits to one another. Number of minutes the switch waits before terminating an idle command line interface session. Zero (0) disables the time out threshold. Interop Mode Standard HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 56
The Stack Links data window fields are described in Table 10. Table 10 Stack Links data window Field Description Status Icon depicting current link status Switch 1 Switch 2 The first switch discovered in the fabric. Displays the port number that the ISL is currently connected to on the - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 57
security-related settings, such as, firmware versions, embedded GUI, in-band management, date/time on switches. Any changes must be made through the appropriate dialog, such as Network Properties dialog, Switch HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 57 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 58
accounts Only the Admin account can manage user accounts with the User Account Administration dialog boxes. However, any user can modify their own password. To open a User Account Administration dialog box, open the Switch menu and select User Accounts. A user account consists of the following data - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 59
> User Accounts. 2. Click the Remove Account tab to open the Remove Account tab page (Figure 24). 3. Select the account (Login) name from the list of accounts at the top of the dialog box. 4. Click Remove Account. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 59 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 60
must remove the account and then add the account with the new password. To change the password for an account on a switch: 1. Select Switch > User Accounts. 2. Click the Change Password tab to open the Change Password tab page (Figure 25). 3. Select the account (Login) name from the list of accounts - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 61
areas become active and you are prevented from manually setting the date and time on the switch • The NTP Server Discovery and NTP Server IP Address fields become active and allow you to select a discovery method HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 61 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 62
Reset operation, fabric services will be unavailable for a short period (30-75 seconds, depending on switch model). Verify that all administrative changes to the fabric (if any) are complete before performing a Nondisruptive Code Load and Activation (NDCLA). When upgrading firmware across a fabric - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 63
. Using the configuration wizard Use the configuration wizard to configure the IP address and password for new or replacement switches. To start the configuration wizard, select Wizards > Configuration Wizard. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 63 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 64
switches is isolated as a separate fabric and the Logged-In LEDs on both switches will flash to show the affected ports. See the HP StorageWorks SN6000 Fibre Channel Switch Command Line Interface Guide the log information to a remote host that supports the syslog protocol. When enabled, the log - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 65
is supported with zones. The default setting is Enabled. In-band management In-band management is the ability to manage switches across inter-switch links. device's management information to be registered. The HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 65 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 66
be changed unless absolutely necessary. The switch is temporarily placed offline to change these values. Managing system services The System Services dialog box (Figure 30) provides a central location for you to enable or disable any of the external user services such as Simple Network Management - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 67
contact HP Services. Call Home to HP Services can be accomplished using HP Service Essentials Remote Support Pack as described in the HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 67 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 68
Properties dialog box, using one of the following methods: • Open the faceplate display for the switch you are configuring, and then select Switch > Network Properties, or • Right-click a switch graphic in the faceplate display, and then select Network Properties from the popup menu. 2. Click - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 69
used anytime you are required to enter an IP address. CAUTION: Disabling this option will prevent you from using an IPv6 IP address for system services. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 69 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 70
be assigned to this switch in order to avoid an IP address conflict. Enter the Internet Protocol address for the Ethernet port. The default value is 10.0.0.1. lease cannot be used, no IP address will be assigned to this switch in order to avoid an IP address conflict. • NDP (Neighbor Discovery - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 71
Select this option to enable the Domain Name Service client. Enter the name of the local switch in order to avoid an IP address conflict. The suffix that is appended to the user-specified hostname for the search. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 72
like passwords and user cannot use an SNMP application at a workstation to talk to a switch that has this setting disabled. Contact Specifies the name (up to 64 characters) of the person who is to be contacted to respond to trap events. The default is . 72 Managing switches - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 73
and newer firmware. The SNMP v3 security is available to a switch that has a secure connection (SSL must be enabled), and can only be configured on the entry switch. The security features provided in SNMPv3 are: HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 73 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 74
you to turn SNMP v3 security on and off, and to add, display, remove, and edit an SNMP v3 user: • To display the SNMP v3 Manager dialog box (Figure 33), open the Switch menu, select SNMP > SNMP v3 Manager. • To turn SNMP v3 security on or off, use the SNMP v3 Security - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 75
phrase that functions as a password that verifies the authenticity of the user. Re-enter the Authentication switch that are currently online except for TR ports, which are not included in Online Switch Diagnostics. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 76
the number of times you entered in the Loop Count field. 7. Select the default test pattern or enter a user-defined (hexadecimal) test pattern. 8. Click Start Test to begin the next test, or click Close to close the Switch Diagnostics dialog box. Observe the results in the Test Results area. If the - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 77
Switch Properties dialog box before an archive can be used in the restore process. The switch type archive must be compatible with the switch to be restored. See "Archiving a switch" on page 77 for more information. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 78
all settings presented in the Network properties dialog box except the IP address. See "Network properties" on page 68. • IP Address-Restores switch IP address in addition to the other network properties. • Port Properties-Restores all settings presented in the Port Properties dialog box. See "Port - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 79
and password settings. The most current port license will remain in effect. To restore user accounts, you must select the Reset User Accounts to Default option in the maintenance menu. See "Recovering a Switch" in the HP StorageWorks SN6000 Fibre Channel Switch Installation and Reference Guide for - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 80
A feature license key is a password that you can purchase from your switch distributor or authorized reseller to upgrade your switch. License keys vary according to the features you purchase. The feature license key available for purchase is the HP StorageWorks SN6000 Stackable 20Gb ISL Upgrade LTU - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 81
: • Zoning modifications • Adding, moving or removing devices attached to the switch fabric. This includes powering up or powering down attached devices. • Adding, moving or removing ISLs or other connections. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 81 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 82
connections must be re-initiated: • QuickTools sessions will re-connect automatically • Telnet sessions must be restarted manually. Future switch firmware releases will support non-disruptive upgrades unless specifically indicated in its associated release notes. An NDCLA operation to earlier - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 83
: The Call Home feature provides an email notification capability for the switch. This service has no relationship with the HP Call Home feature, which notifies HP services. Figure 40 Call Home Setup dialog box HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 83 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 84
default address defined (0.0.0.0 is the default). Primary SMTP Server Address: The IP address of the primary (first) SMTP server. Primary SMTP Server Port: The service agents. The email address of the point-of-contact for the switch. This email address is included in the text of email messages - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 85
the problem is sent to this address. It is an important address for receiving email notices concerning problems. This address is also the default address switch events results in duplicate email messages being sent. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 86
email alert is sent, and where the alerts are sent. Use the Call Home Profile Manager dialog box (Figure 41) to manage all profiles on a switch. You can add new profiles, remove profiles, edit profiles, and make copies of existing profiles. To display the Call Home Profile Manager dialog box, select - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 87
, except the name. 3. Enter a unique name for the profile copy. 4. Click OK to save the new profile. Figure 42 Call Home Profile Editor dialog box HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 87 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 88
Profile Editor-Tech Support Center Profile dialog box You can use the Call Home Profile Editor-Tech Support Center Profile dialog box (Figure 43) to create, edit, or remove a Tech Support Center profile. Figure 43 Call Home Profile Editor-Tech Support Center Profile dialog box 88 Managing switches - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 89
executions of the capture operation. The default is 1. The email address of the recipient added to the Tech Support Center profile. A maximum of 10 addresses is allowed and displayed in the Addresses window. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 89 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 90
Profile Manager dialog box (Figure 41). The Available Switches list shows all the switches in the fabric. Switch names that are disabled do not have current Call Home firmware and cannot receive any profiles. The Selected Switches list shows the switch names that you selected to receive all profiles - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 91
more profiles in the window, and then click Test. To display the Call Home Test Profile dialog box, open the Switch menu, select Call Home, and then select Test Profile. Figure 46 Call Home Test Profile dialog box HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 91 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 92
Change Over The Change Over option changes the inactive SMTP server to the active SMTP server. To make the inactive SMTP become the active SMTP: 1. Select Switch > Call Home > Change Over. Figure 47 Call Home Change Over dialog box 2. Click OK to confirm the change over. 92 Managing switches - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 93
in the data window on the right. Figure 49 Port Information data window buttons The Port Information data window fields are described in Table 19. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 93 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 94
Field Description Summary Group Port Address Port Fibre Channel address. Administrative Port Type Operational Port Type The administrative port type (G, GL, F, FL, TR, or Donor). This value is persistent; it will be maintained during a switch reset. During port auto-configuration, it will - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 95
. If supported, status can be enabled, disabled, or automatically determined by the switch. Device Scan Device scan status. Enabled means the switch queries the assigned to the SFP Transceiver hardware version HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 95 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 96
: • Select Absolute to view the total count of statistics since the last switch or port reset. • Select Rate to view the number of statistics counted per current baseline. The baseline will also be set when the switch status changes from unreachable to reachable. The Port Statistics data window - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 97
not in the offline state. A loss of signal causes the switch to attempt to re-establish the link. If the link is not re-established, a link failure is counted. A link reset is performed after a link failure. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 97 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 98
and does not have a valid AL_PA. Login Count Number of device logins that have occurred on the switch. Logout Count Long Frame Count Loop Timeouts Number of device logouts that have occurred on the switch. Number of incidents in which one or more frames greater than the maximum size (2,136 bytes - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 99
Symbolic Name User-defined name for a port. Operational State The port state that is currently active. This value may be different from the administrative port state, for example, due to an error condition. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 99 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 100
saved in the switch configuration, either by the user or at the factory. This value is persistent; it will be maintained during a switch reset, and will the port is connected to an initiator device with an HBA. The default is Auto. The Device Scan feature queries the connected device during login - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 101
state request to the switch. Table 23 Port administrative states State Description Online Offline Activates and prepares port to send data. Prevents port from receiving signal and accepting a device login. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 101 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 102
be mapped to devices on the local HP SN6000 Fibre Channel Switch fabric. TR_Ports do not support online port diagnostics (see "Testing ports" on page 105). Donor Donor port-Enables buffer credits to be used by another port. Port speeds SFP ports with 8Gb SFPs installed can transmit and receive at - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 103
Gb/s Fixed 8 Gb/s transmission speed 10 Gb/s 20 Gb/s Fixed 10 Gb/s transmission speed. Fixed 20 Gb/s transmission speed. Requires the HP StorageWorks SN6000 Stackable 20Gb ISL Upgrade LTU feature license key. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 103 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 104
and reception of RSCN messages. • Auto-Suppresses the reception of RSCN messages when the port is connected to an initiator device with an HBA. The default is Auto. See "Device Scan" on page 104. Device Scan The Device Scan feature queries the connected device during login for FC-4 descriptor - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 105
on the operational state of the port. The AL Fairness option controls how frequently the switch can arbitrate for access. Applies only to ports running in loop (FL) mode. ASIC matches the frame that was received. HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 105 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 106
you click Stop Test. The Loop Count option runs the test a specific number of times. 7. Select a Test Pattern option: Accept the default test pattern, or select the User-Defined option and enter a value. 8. Click Start Test to begin the test. Observe the results in the Test Results area. NOTE: If - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 107
Port E_Port that connects to another FC-SW-2 compliant switch. Fabric database The set of fabrics opened during a QuickTools session. Fabric management The switch through which the fabric is managed. switch HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 107 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 108
devices on an HP SN6000 Fibre Channel Switch (local) fabric and devices on a remote fabric of other vendor switches. An IFZ contains three WWN members: the local device, the remote device, and the TR_Port attached to the remote fabric. Inactive firmware The firmware image on the switch that is - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 109
connected by their high speed stacking ports. QuickTools auto-detects switches connected by their 10 Gb/s or 20 Gb/s ports and displays these stacked switches as a single stack entity in the faceplate display HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 109 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 110
The port type used to map devices on an HP SN6000 Fibre Channel Switch (local) fabric to devices in a remote fabric of other vendor switches. User account An object stored on a switch that consists of an account name, password, authority level, and expiration date. VCCI Voluntary Control Council - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 111
inter-switch links 24 M managing the zoning database 40 memory workstation 13 menu bar 17 N NDCLA 62 network properties 68 nickname 34 nickname files 36 Nondisruptive Code Load and Activation 62 O online Help 20 HP StorageWorks SN6000 Fibre Channel Switch QuickTools Switch Management User Guide 111 - HP StorageWorks SN6000 | HP StorageWorks SN6000 QuickTools Switch management use - Page 112
51 Switch data window buttons 52 switch properties 64 switch timeout values 66 symbols in text 10 syslog 64 System Services 66 T technical support, HP 11 testing ports 105 text symbols 10 TR Mapping Manager dialog 26 transceiver media 104 Transparent Router 25 112 U user accounts 58 user accounts
HP StorageWorks SN6000 Fibre Channel Switch