HP StorageWorks XP10000 Disk Array Site Preparation Guide Part number: AE102-96014 Seventh edition: March 2008 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 2
reserved. Confidential computer software. Valid license from HP required for possession, use or copying. HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 3
11 Site preparation team ...11 HP representative responsibilities 11 Customer responsibilities ...11 Site preparation tasks ...11 Site preparation checklist ...12 Site preparation time allowances 14 2 Site requirements for the XP10000 disk array 17 Disk array physical specifications 17 Basic and - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 4
specifications 33 Acoustic specifications ...35 Controlling dust and pollution 35 Preventing metallic particulate contamination 36 Data communication requirements 36 HP StorageWorks power supply (UPS 39 3 Electrical specifications for the XP10000 disk array 41 AC line voltage requirements ...41 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 5
Figures 1 Fully configured XP10000 rack assembly 18 2 Primary rack dimensions 27 3 Primary and secondary rack dimensions and cutouts 28 4 7 European single phase power connection 44 8 Removing the outer carton 48 9 Removing the inner packaging 49 XP10000 Disk Array Site Preparation Guide 5 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 6
load rating and available front clearance ....... 31 6 Temperature specifications 31 7 Humidity specifications 32 8 Mechanical vibration specifications 33 9 Shock specifications 33 10 Maximum heat and power specifications 33 11 Air flow specifications 34 12 Component heat dissipation and power - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 7
StorageWorks XP10000 Disk Array Owner's Guide • HP StorageWorks XP Remote Web Console user guide for XP12000/XP10000 Disk Arrays and SVS 200 • HP StorageWorks XP disk array configuration guides for host operating systems You can find these documents from the Manuals page of the HP Business Support - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 8
clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. Conventions for storage capacity values Use the following values to calculate physical storage capacity (hard disk drives) for HP - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 9
convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished by CSR. For more information about CSR, contact your local service provider. For North America, see the CSR website: XP10000 Disk Array Site Preparation Guide 9 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 10
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 About this guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 11
install and maintain XP disk arrays. This team: • Helps you to determine and implement the site requirements for your specific site and array configuration • Coordinates all HP resources to ensure successful delivery and installation of the disk array Your HP Service Representative is your primary - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 12
, contact your HP Service Representative to coordinate delivery of the disk array equipment. 7. If you choose to unpack the equipment cartons without HP supervision, follow the instructions in chapter 4. 8. Contact the HP Service Representative to schedule disk array installation and configuration - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 13
, page 35 Preventing metallic particulate contamination, page 36 Does the computer room support other * environmental considerations (such as vibration and acoustics)? Mechanical vibration specifications, page 32 Acoustic specifications, page 35 XP10000 Disk Array Site Preparation Guide 13 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 14
* Does the input voltage correspond to the equipment specifications? Electrical requirements, page 37 * Are the input HP representatives need a security code)? N/A Are all floors, stairs, elevators, * stairwalkers, lifts, ramps, or ladders needed to move the equipment adequate to support - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 15
communication equipment, including any equipment needed for the Internet-based remote support option The time between placing an equipment order and actual delivery can vary. Contact your HP representative to determine the best estimated delivery dates. XP10000 Disk Array Site Preparation Guide 15 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 16
16 Site preparation team and tasks - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 17
specifications Use the information in this section to determine the total dimensions and weight for your specific array configuration. You will need these values to complete other procedures in this chapter. Figure 1 shows the disk array equipment racks. XP10000 Disk Array Site Preparation Guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 18
with control panel and SVP blade PC • One 60-disk chassis • Mix board with disk adapters and host ports • Power supplies, power distribution units (PDUs), backup batteries, power cords, and cabling The XP10000 disk array without a disk chassis is also available. 18 Site requirements for the - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 19
Table 2 Rack dimensions and weights Rack specification Width Depth Height Weight, primary rack, HP XP12000/10000 16-port 2-Gbps FC CHIP HP XP12000/10000 32-Port 2-Gbps FC CHIP HP XP12000/10000 2-Gbps FC SFP LW Transceiver 5.0 5.8 0.02 11.0 12.8 0.04 XP10000 Disk Array Site Preparation Guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 20
Memory HP XP10000 Disk Chassis HP XP10000 16-Port FC SW CHIP 8-Port ACP HP XP10000 4Gb CHIP/ACP Combo Board HP XP10000 Battery HP XP10000 Second Rack Disk Array Frame - DKU HP XP10000 73-GB 15k-rpm Array Group HP XP10000 73-GB 15k-rpm Spare Disk HP XP10000 146-GB 10k-rpm Array Group HP XP10000 146 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 21
HP XP10000 300-GB 10k-rpm Spare Disk HP XP10000 300-GB 15k-rpm Array Group HP XP10000 300-GB 15k-rpm Spare Disk HP XP10000 400GB 10k rpm Array Group-4 disks HP XP10000 400GB 10k rpm Spare Disk kg lb 1 2.2 4 8.8 1 2.2 4 8.8 1 2.2 4 8.8 1 2.2 Calculating the weight of your disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 22
Memory 0.44 x 1 = HP XP12000/10000 1-GB Shared Memory 0.13 x 3 = HP XP10000 Disk Chassis (holds up to 60 drives) 177.0 x 1 = HP XP10000 16-Port FC SW CHIP 8-Port ACP 11.0 x 1 = HP XP10000 Battery 17.6 x 1 = HP XP10000 300-GB 10k-rpm Array Group 8.8 x 28 = HP XP10000 300-GB 10k-rpm - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 23
the disk array to the computer room can support the data center/computer room environment. HP recommends that you follow these during servicing operations refers to the static discharge that can be generated when two objects are separated. For example XP10000 Disk Array Site Preparation Guide 23 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 24
servicing hazards Your staff and HP service array for service access and to ensure proper weight distribution on the computer room floor • For raised floors, includes correctly positioned floor cutouts for the disk array's power and data cables 24 Site requirements for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 25
HP representatives. Floor requirements XP disk arrays can be installed on solid surface (concrete) or raised floors. All computer room floors must meet the following requirements: • The floor must be able to support ramps must not exceed a 10 degree slope. XP10000 Disk Array Site Preparation Guide 25 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 26
HP recommends a tiled floor. CAUTION: HP strongly discourages the use of carpeting, including antistatic varieties, within 6.0 m (20 ft.) of the disk array. Over time, carpeting may shed dust that can cause problems with the disk array power cabling. 26 Site requirements for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 27
for additional notes. Figure 2 Primary rack dimensions Primary and secondary rack dimensions and cutout locations Figure 3 shows floor clearance dimensions when two racks are installed. XP10000 Disk Array Site Preparation Guide 27 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 28
and cutouts Calculating clearances The total floor space required for the XP10000 disk array includes: • The actual space required by the equipment. • Service clearance - the floor space required to access the disk array. Never use this space for storage. • Additional space required to properly - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 29
in Figure 4 refer to the following: • Clearance a is the space between the service clearance at the left side of the array (100 mm minimum for installing the kick plate) and any other object, such as (0 cm). The smaller c is, the larger a and b must be. XP10000 Disk Array Site Preparation Guide 29 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 30
service clearance 100 mm (3.94 in) 100 mm (3.94 in) 1000 mm (39.4 in) 1000 mm (39.4 in) Equals total clearance Notes on primary rack floor loading and clearances: • Provide 100 mm of clearance on both sides of the disk array shown in Table 5. 30 Site requirements for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 31
structural engineer. Temperature specifications Table 6 Temperature specifications Temperature range type Recommended operating temperature range Operating temperature Range 21 to 24 degrees C 70 to 75 degrees F 16 to 32 degrees C 61 to 89 degrees F XP10000 Disk Array Site Preparation Guide 31 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 32
built-in humidifier. You should not see any condensation in or around the disk array under any conditions. There is no procedure for recovery from moisture condensation. Table 7 Humidity specifications Humidity range type Noncondensing relative humidity (RH) Operating humidity range at 22 degrees - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 33
number of disk drives. Table 10 Maximum heat and power specifications Parameter Power consumption (kVA) Heat dissipation (kW) BTUs per hour Kcal per hour Primary Rack 4.9 4.6 15710 3959 Second Rack 3.2 3.0 10246 2582 Full array 8.1 7.6 25955 6541 XP10000 Disk Array Site Preparation Guide 33 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 34
Table 11 shows the air flow requirements for the frames and disk chassis. Table 11 Air flow specifications Product No. Description AE102A AE104B AE115B HP XP10000 Disk Control Frame - DKC HP XP10000 Disk Chassis HP XP10000 Disk Array Frame Air flow in cubic meters per minute 15 8 8 Table 12 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 35
HP XP10000 Battery AE115B HP XP10000 Disk Array Frame AE120A HP XP10000 73-GB 15k-rpm Array Group AE121A HP XP10000 146-GB 10k-rpm Array Group AE122A HP XP10000 146-GB 15k-rpm Array Group AE123B HP XP10000 300-GB 10k-rpm Array Group AE128A HP XP10000 300-GB 15k-rpm Array Group AE120AS HP XP10000 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 36
bottom of some raised floor tiles. Although this problem is relatively rare, it may be an issue XP10000 disk array. Table 13 Data communication requirements Item Description A dedicated analog phone line for C-Track modem remote support option (if chosen) If you plan to use the HP StorageWorks - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 37
your staff and HP representatives to communicate inside the disk array and outside your site. HP StorageWorks XP Continuous Track (C-Track) The HP StorageWorks XP Continuous Track (C-Track) remote support solution detects and reports system problems to the HP Storage Technology Centers (STCs - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 38
problems and can create a fire hazard. A shared neutral conductor that fails open-circuit can cause overvoltage damage to equipment. See chapter 3 for specific power requirements as well as plug and receptacle part numbers and ordering information. 38 Site requirements for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 39
powered by a site-wide UPS for the HP XP10000 disk array. Make sure your UPS satisfies the power requirements listed in "Heat dissipation, power consumption, and air flow specifications" on page 33 and also in "AC line voltage requirements" on page 41. XP10000 Disk Array Site Preparation Guide 39 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 40
40 Site requirements for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 41
be capable of supporting the entire current demand for the rack. Each PDU is fitted with an IEC320-C20 inlet that fits the supplied input power cord, and four IEC320-C13 outlets that connect to the hardware inside the rack by means of supplied cables. XP10000 Disk Array Site Preparation Guide 41 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 42
for the second rack HP offers the following AC power cables and connectors, which you can order individually (four each are required per primary or second rack): • HP 4.5 m power cord w/NEMA L6-30P plug • HP 4.5 m power cord w/NEMA L6-20P plug 42 Electrical specifications for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 43
power until instructed to do so by HP. An HP representative should be present whenever the disk array is being connected to a new power source. Branch circuit requirements To protect the disk array, your (PDU) input, which is a type IEC 320-C20 connector. XP10000 Disk Array Site Preparation Guide 43 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 44
in Figure 7. CAUTION: Do not apply power until instructed to do so by HP. An HP representative should be present whenever the disk array is being connected to a new power source. Figure protective earth connection before the supply connections. 44 Electrical specifications for the XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 45
HP recommends that three physically able personnel be available to assist with offloading the disk array equipment from the pallet. Personnel must be knowledgeable and experienced with the safe handling of large, heavy, and sensitive computer equipment. XP10000 Disk Array Site Preparation Guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 46
Unpacking process If you need to unpack the equipment without HP supervision, follow the instructions in this section. 1. Following the steps in "Removing the disk array. 3. As you unpack the cartons, match the delivered items to the packing list (invoice) for each carton. Contact your HP Service - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 47
. When you move the racks on their casters, the rolling surface must be able to support the equipment weight and must be free of surface conditions that could cause shock or vibration to ramp you will use to unload both equipment racks. See the figures XP10000 Disk Array Site Preparation Guide 47 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 48
below for key packaging points. Steps 2 through 5 refer to Figure 8. Steps 6 through 8 refer to Figure 9. 1. If shipped in a wooden crate: a. Using an 11mm (7/16") ratchet or wrench, remove the six lag screws at the base of the crate. b. Using the claw end of a claw hammer, remove the crate clamps, - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 49
that anchor the cabinet to the pallet. 8. Remove the poly bag covering the cabinet. 9. Following the instructions provided on the wooden ramp, attach the ramp to the pallet and roll the cabinet onto the floor. 10. Visually check the unit for any damage. XP10000 Disk Array Site Preparation Guide 49 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 50
50 Delivery and unpacking - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 51
control processor. On some HP XP models, such as the HP XP12000, the ACP handles the passing of data between the cache and the physical drives. On other HP XP models, such as the HP XP10000 disk array, this function is handled by the disk adapter on the MIX board. AL Arbitrated loop. AL-PA - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 52
disk array supports a certain number of CUs, depending on the disk array disk unit (DKU) The array hardware that houses the disk array physical disks. disk controller (DKC) The array hardware that houses the channel adapters and service processor (SVP). disk when the HP StorageWorks LUN - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 53
as two-digit hexadecimal numbers. For example, host mode 08 represents an HP-UX host. Using two or more servers as a standby in case disk control unit that includes disk adapters and channel adapters for interfacing disk drives and the host to cache memory. XP10000 Disk Array Site Preparation Guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 54
adapter. The XP family of disk arrays supports Fibre Channel (FC) ports as well as other port types. Ports are named by port group and port letter, such as CL1-A. CL1 is the group, and A is the port letter. Point-to-point. The XP10000 rack that contains the basic disk array components, including the - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 55
supported by your specific XP disk array. Random access memory. HP StorageWorks RAID Manager XP, a command line interface for managing XP arrays. Remote service information message. Read/write. A file containing a shell script. Small computer system interface. The optional second XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 56
56 Glossary - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 57
, 9 customer, site prep responsibilities of, 11 D damage, shipping, 45 data communication requirements, 36 See also cables, 36 delivery equipment, 45 space requirements, 22 dimensions, 19 XP10000 Disk Array Site Preparation Guide 57 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 58
safety, 24 XP Continuous Track, 36 HP Service Representative, 11, 11, 45 HP SR, 46 humidity, 31, 32 and ESD, 23 I Internet-based remote support, 36 L LAN connection, 36 lightning, 39 line current, 41 line voltage, 37 M mechanical vibration specifications, 32 metallic particulate contamination, 36 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 59
support HP, 9 service locator website, 10 text symbols, 8 transients, power, 39 U uninterruptible power supply (UPS), 39 unpacking equipment, 45 UPS, 39 V vapor barrier, 23 vibration specifications, 32 voltages, 41 W warning rack stability, 9 wax, conductive, 23 waxed floors, 23 XP10000 Disk Array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Site Preparation Gu - Page 60
websites, 7 customer self repair, 9 HP, 10 HP Subscriber's choice, 10 weights, 19, 19 calculating, 21 wet bulb temperature, 32 windows, in the computer room, 23 X XP Continuous Track, 37 60
HP StorageWorks
XP10000 Disk Array Site Preparation Guide
Part number: AE102-96014