- HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 1
HP StorageWorks XP10000 Disk Array Owner's Guide Part number: AE102-96013 Seventh edition: March 2008 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 2
reserved. Confidential computer software. Valid license from HP required for possession, use or copying. HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 3
components 15 Optional components ...15 HP XP10000 supported features 15 HP XP10000 specifications 15 Supported operating systems 16 Supported external storage 17 Web-based array management 17 HP StorageWorks XP Continuous Track 17 HP XP10000 Software ...17 Storage management software - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 4
is restored 30 To restart the disk array manually 30 Automatic restart when power is restored 30 Operating specifications ...31 Temperature ...31 Humidity ...31 Mechanical vibration ...32 AC line voltage requirements 32 4 HP XP10000 Troubleshooting 33 Service information messages ...33 Failure - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 5
Figures 1 HP XP10000 Disk Array configuration 13 2 HP XP10000 control panel components 22 3 Backup power sequence 25 4 Optional HP StorageWorks XP Command View Advanced Edition software configuration ...26 5 Failure detection and reporting process 33 XP10000 Disk Array Owner's Guide 5 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 6
Tables 1 Document conventions 7 2 HP XP10000 Disk Array specifications 15 3 HP XP10000 control panel components 22 4 Temperature specifications 31 5 Humidity specifications 31 6 Mechanical vibration specifications 32 7 AC voltage specifications 32 8 Failure detection and reporting process 33 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 7
user guide for XP12000/XP10000 Disk Arrays and SVS 200 • HP StorageWorks XP External Storage for XP12000/XP10000 Disk Arrays and SVS 200 • HP StorageWorks XP disk array configuration guides for host operating systems You can find these documents from the Manuals page of the HP Business Support - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 8
in bodily harm or death. CAUTION: Indicates that failure to follow directions could result in damage to equipment or data. IMPORTANT: Provides clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. 8 About this - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 9
website: http://www.hp.com/support/ Collect the following information before calling: • Technical support registration number (if applicable) • Product serial numbers • Product model names and numbers • Error messages • Operating system type and revision level XP10000 Disk Array Owner's Guide 9 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 10
http://www.hp.com/support/manuals • http://www.hp.com/support/downloads Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 About this guide - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 11
Track monitoring software detects internal hardware component problems and automatically reports them to the HP Storage Technology Center (STC) before they are noticed by operators and users. An HP support representative can verify the problem and perform XP10000 Disk Array Owner's Guide 11 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 12
or hosts. For more information, see "HP StorageWorks Continuous Track XP" on page 17. Connectivity disk array is scalable to accommodate your current and future storage capacity needs. Figure 1 and the following text describe the disk array equipment racks. 12 Overview of the HP XP10000 Disk Array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 13
Front of the open HP XP10000 disk array 3. R0 disk chassis, containing up to 60 disk drives 5. Primary rack 7. R2 disk chassis, containing up to 60 disk drives 2. Controller, power supplies, control panel, SVP, disk adapters 4. R1 disk chassis, containing up to 60 disk drives 6. Second rack 8. R3 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 14
HP StorageWorks XP Continuous Track • Advanced remote diagnostics • Full solution (host-SAN-storage) support • Full software and solution integration enabled by HP software products. For more information, see "HP XP10000 Software" on page 17. HP XP10000 product contents The HP XP10000 disk array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 15
• HP StorageWorks Command View XP Advanced Edition Software For more information about software options, see "HP XP10000 Software" on page 17 or contact your HP support representative. HP XP10000 supported features This section summarizes basic features of the disk array. HP XP10000 specifications - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 16
HP for the firmware required to achieve the maximum number of LDEVs. Supported operating systems The disk array supports the following operating systems: • HP-UX • Linux • Windows • HP OpenVMS • HP Tru64 • Sun Solaris • IBM AIX • Novell NetWare • SGI IRIX64 16 Overview of the HP XP10000 Disk Array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 17
disk arrays • Specific disk array models of other manufacturers. Consult an HP representative for details. For more information about HP external storage, see the HP StorageWorks XP External Storage for XP12000/XP10000 Disk Arrays and SVS 200. Web-based array management The disk array comes with HP - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 18
with HP storage replication solutions. XP data protection and recovery software products include: • HP StorageWorks XP Business Copy Software • HP StorageWorks XP Snapshot Software • HP StorageWorks XP Continuous Access Software (Synchronous and Asynchronous) 18 Overview of the HP XP10000 Disk Array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 19
Remote Copy (XRC) Software • HP StorageWorks Dataset Replication Manager (Logical Volume Divider) • HP StorageWorks XP Data Exchange • Hitachi Cache Manager • Hitachi ShadowImage™ for z/OS • Hitachi TrueCopy up™ for z/OS • Hitachi Universal Replicator™ for z/OS XP10000 Disk Array Owner's Guide 19 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 20
20 Overview of the HP XP10000 Disk Array - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 21
optional second SVP is available. Control panel Once the disk array is powered on and running normally, no user operations are required at the control panel, except when instructed by your HP support representative. Figure 2 and Table 3 describe the control panel. XP10000 Disk Array Owner's Guide 21 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 22
disk array is set up with remote support; your HP support representative is notified automatically. If the disk array is not set up with remote support, place a service call to HP to have the message evaluated to determine if any action is required. BLINKING: The DC is under voltage. 22 HP XP10000 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 23
, this switch should be in the ENABLE position. DISABLE: No one can provide remote maintenance. ENABLE: An HP support representative can provide remote maintenance. CAUTION: Do not change the switch position unless directed to do so by HP service personnel. XP10000 Disk Array Owner's Guide 23 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 24
of disk capacities are available. Ask your HP support representative about currently available disk drives. The disk array automatically detects and corrects disk errors, and an HP support representative can replace any of the disk drives without disrupting user activity. 24 HP XP10000 hardware - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 25
can contain up to 16. Any of the spare disk drives can back up any other disk drive of equal rotational speed and equal or lesser capacity, in any disk chassis, even if the failed disk and the spare disk are in different array domains. The XP10000 disk array supports 73 GB, 146 GB, 300 GB and 400 GB - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 26
1. Command View XP Advanced Edition server 2. Ethernet LAN connection 3. XP disk array Figure 4 Optional HP StorageWorks XP Command View Advanced Edition software configuration 26 HP XP10000 hardware components - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 27
and procedures in all documentation for this and related products. CAUTION: Disk array maintenance must be done only by trained and qualified HP support representatives. Only an HP support representative can power off the disk array, except in an emergency. XP10000 Disk Array Owner's Guide 27 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 28
power cord. The power cord may not be used with other products. Powering down the disk array Two situations may arise when you need to power down the system: • Emergency power off • Planned power off For instructions in each of these situations, see the following procedures. 28 HP XP10000 operations - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 29
HP support representative to schedule a planned power off. CAUTION: Only a trained HP support representative can shut down and power off the system. Do not attempt to power down the disk array see the following text about manual and automatic restart of the system. XP10000 Disk Array Owner's Guide 29 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 30
(s) first and make sure they are operating properly. For assistance recovering from a power outage, contact your HP support representative. To restart the disk array manually: 1. On the control panel, move the PS ENABLE switch to the ENABLE position. 2. Move the PS ON/OFF switch to the ON position - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 31
for remote support, signifying a SIM was generated because the system lost power unexpectedly. READY LED turns green, signifying the system is ready. CAUTION: Powering on the disk array can take several minutes. Power on is complete only when the READY LED turns green. Operating specifications This - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 32
about electrical specifications, cabling, and connectors, see the HP StorageWorks XP10000 Disk Array Site Preparation Guide. Table 7 AC voltage specifications Parameter 200 outages. Consult your local HP service representative about which power cords are to be attached to the two power sources. - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 33
, and logged 4 on the Device Manager server as remote SIMs (R-Sims). If the disk array is not set up with remote support, when a SIM is generated, the amber message LED on the system control panel turns on. Call HP to determine the reason for the message. XP10000 Disk Array Owner's Guide 33 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 34
support, HP XP Continuous Track reports the SIMs to STC through a dedicated dialup connection.SIMs are classified according to severity: service, moderate, serious, or acute. Service and immediately to STC to ensure that the problem is addressed as soon as possible. 34 HP XP10000 Troubleshooting - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 35
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual 's device certification tests were conducted with HP computer systems and HP shielded cables, such as those you Electromagnétique. XP10000 Disk Array Owner's Guide 35 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 36
VCCI EMC statement (Japan) BSMI EMC statement (Taiwan) RRL EMC statement (Korea) Harmonics conformance (Japan) German noise declaration XP10000: Schalldruckpegel Lp = 70 dB(A) Am Arbeitsplatz (operator position) Normaler Betrieb (normal operation) Nach ISO 7779:1988 / EN 27779:1991 (Typprüfung) - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 37
maintenance operations, service operations, or adjustments to be performed on the Optical Link Module. Japan DENAN law cordset caution Please use the supplied power cord. The power cord may not be used with other products. European WEEE statements Czech Danish XP10000 Disk Array Owner's Guide 37 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 38
Dutch English Estonian 38 Regulatory statements - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 39
Finnish French German XP10000 Disk Array Owner's Guide 39 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 40
Greek Hungarian Italian 40 Regulatory statements - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 41
Latvian Lithuanian Polish XP10000 Disk Array Owner's Guide 41 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 42
Portuguese Slovak Slovenian 42 Regulatory statements - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 43
Spanish Swedish XP10000 Disk Array Owner's Guide 43 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 44
44 Regulatory statements - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 45
copies of logical volumes on the disk array. C-Track The HP StorageWorks XP Continuous Track software program, which detects internal hardware component problems on a disk array and automatically reports them to the HP STC. Continuous Access The HP StorageWorks XP Continuous Access program, which - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 46
disk array supports a certain number of CUs, depending on the disk array disk controller (DKC) The array hardware that houses the channel adapters and service processor (SVP). disk group The physical disk locations associated with a parity group. disk when the HP StorageWorks LUN Configuration - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 47
as two-digit hexadecimal numbers. For example, host mode 08 represents an HP-UX host. Using two or more servers as a standby in case the disk control unit that includes disk adapters and channel adapters for interfacing disk drives and the host to cache memory. XP10000 Disk Array Owner's Guide 47 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 48
. The XP family of disk arrays supports Fibre Channel (FC) ports as well as other port types. Ports are named by port group and port letter, such as CL1-A. CL1 is the group, and A is the port letter. Point-to-point. The HP XP10000 rack that contains the basic disk array components, including the - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 49
are supported by your specific XP disk array. Random access memory. HP StorageWorks RAID Manager XP, a command line interface for managing XP arrays. Remote service information message. Read/write. A file containing a shell script. Small computer system interface. The optional second HP XP10000 disk - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 50
50 Glossary - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 51
, 7 documentation HP website, 7 providing feedback, 10 related, 7 E emergency power off, 28, 29 environmental specifications, 31 external storage, 17 F failure detection and reporting process, 33 features data integrity, 14 high availability, 14 software, 14 XP10000 Disk Array Owner's Guide 51 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 52
disk array frame, 24 disk control frame, 21 disk drives, 24 features, 14 management server, 25 normal operations, 27 physical components, 21 RAID options, 15 service processor. See SVP, 21 specifications, 16, 31 hazard warnings, 27 help obtaining, 9 high availability, 14 HP technical support, 9 HP - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 53
W warning hazard, 27 rack stability, 9 websites customer self repair, 10 HP, 10 HP Subscriber's Choice for Business, 10 product manuals, 7 wet bulb temperature, 31 X XP Continuous Track, 11, 14, 17, 34 XP10000 Disk Array Owner's Guide 53 - HP StorageWorks XP10000 | HP StorageWorks XP10000 Disk Array Owner's Guide (AE10 - Page 54
54
HP StorageWorks
XP10000 Disk Array Owner's Guide
Part number: AE102-96013
Seventh edition: March 2008