HP StorageWorks XP Disk Array Configuration Guide for IBM AIX HP XP24000 Disk Array nl HP XP20000 Disk Array nl HP XP12000 Disk Array nl HP XP10000 Disk Array nl HP 200 Storage Virtualization System Abstract This guide provides requirements and procedures for connecting an XP disk array or SVS 200 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 2
software. Valid license from HP required for possession, use or copying. Consistent with FAR 12.211 and 12.212, Commercial Computer Software, Computer Software services. Nothing herein should be construed as constituting an additional warranty. HP shall not be liable for technical or editorial errors - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 3
Troubleshooting 27 Error conditions ...27 3 Support and other resources 29 Related documentation ...29 Conventions for storage capacity values 29 HP technical support ...30 Subscription service ...30 HP websites ...30 Documentation feedback ...30 A Path worksheet 31 Worksheet ...31 B Disk array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 4
Supported emulations ...33 Emulation specifications ...33 Disk parameters by emulation type 36 Byte information table ...44 Physical partition size table ...44 Glossary 47 Index 51 4 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 5
Figures 1 SNMP configuration 9 2 Point-to-point fabric topology example 13 3 Multi-cluster environment 14 XP Disk Array Configuration Guide for IBM AIX 5 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 6
11 2 Fabric topology settings 13 3 Fabric zoning and LUN security settings 14 4 Device parameters-read/write timeout and queue type 16 5 Device parameters-queue depth 17 6 Error conditions ...27 7 Path worksheet ...31 8 Supported emulations 33 9 Emulation specifications 33 10 OPEN-3 parameters - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 7
. Refer to the adapter docu- mentation for installation details. • HP StorageWorks XP Remote Web Console, HP StorageWorks XP Command View Advanced Edition Software or HP StorageWorks XP Command View with LUN management feature for configuring disk array ports and paths. • HP StorageWorks XP Array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 8
software products that provide host, application, or I/O path failover and management. SNMP configuration The XP family of disk arrays and the SVS 200 support standard Simple Network Management Protocol (SNMP) for remotely managing arrays. The SNMP agent on the service processor (SVP) performs - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 9
XP Remote Web Console or XP Command View Advanced Edition Software. Refer to the applicable user's guide for procedures. Figure 1 SNMP configuration . XP RAID Manager command devices HP StorageWorks XP RAID Manager manages HP StorageWorks XP Business Copy Software or HP StorageWorks XP Continuous - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 10
XP Remote Web Console, XP Command View Advanced Edition Software, or XP Array Manager to complete the remaining tasks listed below. If you do not have these programs, your HP service representative can perform these tasks for you. Setting the host mode and host group mode for the disk array ports - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 11
product, it can not be set from the Remote Web Console until microcode 60-01-68-00/00 or greater. CAUTION: Changing host group modes for ports where servers are already installed and configured is disruptive and requires the server to be rebooted. XP Disk Array Configuration Guide for IBM AIX 11 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 12
of the host. Notify your HP representative if you install storage agnostic software (such as backup or cluster software) that may require specific settings. Configuring the Fibre Channel ports Configure the disk array Fibre Channel ports by using XP Remote Web Console (shown) or XP Command View - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 13
disk array. Loading the operating system and software Follow the manufacturer's instructions to load the operating system and software onto the host. Load all OS patches and configuration utilities supported by HP nodes share access to the disk array. XP Disk Array Configuration Guide for IBM AIX 13 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 14
heterogeneous (more than one OS type present in the SAN) Required LUN Security Must be used when multiple hosts or cluster nodes connect through a shared port Connecting the disk array The HP service representative connects the disk array to the host by: 1. Verifying operational status of the - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 15
Manager User's Guide or the HP StorageWorks XP Command View Advanced Edition Software Device Manager Web Client User's Guide. Note the LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device configuration. Verifying host recognition of disk array devices 1. Log - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 16
is installed on bus 60 and has TID=5 and LUN=0. 4. Record the device file names for the new devices. You will use this information in changing the device parameters. 5. Use the lscfg command to find out the AIX disk device's corresponding array LDEV designation. Example # lscfg -vl hdisk3 In this - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 17
not provide the best I/O performance for your system. You can adjust the queue depth setting to optimize the I/O performance of the disk array. Displaying the device parameters all devices were successfully changed. Example # lsattr -E -l hdisk3 XP Disk Array Configuration Guide for IBM AIX 17 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 18
item and press Enter. Software Installation and Maintenance Software License Management Devices System Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance & Resource Scheduling System Environments - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 19
Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance & Resource Scheduling System Environments Processes & Subsystems Applications Using SMIT (information only) XP Disk Array Configuration Guide - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 20
Manager. Example System Storage Management (Physical & Logical Storage) Move cursor to desired item and press Enter. Logical Volume Manager File Systems Files & Directories Removable Disk Management *1 System Backup Manager 4. Select Volume Groups. Example Logical Volume Manager for the XP disk array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 21
your last chance to stop before continuing. Press Enter to continue. Press Cancel to return to Manager Information Tool (SMIT). This operation is not required when the volumes are used as raw devices. The largest file system permitted in AIX is 64 GB. 1. Start SMIT. XP Disk Array Configuration Guide - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 22
Software Installation and Maintenance Software License Management Devices System Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance System 22 Installing and configuring AIX for the XP disk array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 23
desired item and press Enter. Journaled File Systems CDROM File Systems Network File System (NFS) Cache Fs *1 6. Select Add a Journaled File System Example Journaled File System Move cursor to desired cursor to desired item and press Enter. rootvg vg01 XP Disk Array Configuration Guide for IBM AIX 23 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 24
partition size. Calculate the maximum size of the file system as follows: (FREE PPs - 1) x (PP SIZE) x 2048 Mount Point: Enter mount point name. (Make a list of the mount point names for reference on the Command Status line. 11. To continue creating Journaled File Systems, press the F3 disk array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 25
system 375982 Nov 30 17:25 smit.log.back1 # cp smit.log.back1 smit.log.back2 # ls -l -rw-rw-rw- 1 root system 375982 Nov 30 17:25 smit.log.back1 -rw-rw-rw- 1 root system 375982 Nov 30 17:28 smit.log.back2 # rm smit.log.back1 # rm smit.log.back2 XP Disk Array Configuration Guide for IBM AIX 25 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 26
recovery or backup solution and are not a replacement for standard disaster recovery planning and backup/recovery methodology. 26 Installing and configuring AIX for the XP disk array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 27
resolve an error condition, ask your HP support representative for assistance. Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: • In XP Remote Web Console (Status tab) • In XP Command View Advanced Edition Software (Alerts window - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 28
. The host detects a parity error. Check the FCA and make sure it was installed properly. Reboot the host. The host hangs or devices are declared and the host hangs. Make sure there are no duplicate disk array TIDs and that disk array TIDs do not conflict with any host TIDs. 28 Troubleshooting - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 29
HP StorageWorks XP24000 Disk Array: Owner's Guide • HP StorageWorks 200 Storage Virtualization System: Owner's Guide • HP StorageWorks XP24000/XP20000 LUN Manager User's Guide • HP StorageWorks SAN Design Reference Guide • HP StorageWorks XP Command View Advanced Edition Software Device Manager Web - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 30
number (if applicable) • Product serial numbers • Error messages • Operating system type and revision level • Detailed questions Subscription service HP recommends that you register your product at the Subscriber's Choice for Business website: http://www.hp.com/go/e-updates After registering, you - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 31
TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: XP Disk Array Configuration Guide for - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 32
32 Path worksheet - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 33
Yes Yes Yes NOTE: For the SVS 200, and the XP24000/XP20000/XP12000/XP10000 when connected to external storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host. This allows external storage LDEVs to be configured without losing data. Using any other emulation - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 34
) / 10242 The value n is the number of volumes combined together. For example, with 8 combined volumes: OPEN-V*8. Note 1: The availability of an emulation depends on the disk array. 34 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 35
SCSI disk devices, even though the interface is Fibre Channel. Note 3: The command device (used for XP Raid Manager) is user) x 1024/720 x n Example For a CVS LUSE volume with capacity = 37 MB and n = 4: # of cylinders = 37 x 1024/720 x 4 = 52.62 x 4 = 53 x 4 = 212 XP Disk Array Configuration Guide - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 36
cylinders for a CVS LUSE volume = # of cylinders = (capacity (MB) specified by user) x 16/15 x n Example For an OPEN-V CVS LUSE volume with capacity = size using XP Remote Web Console or XP Command View Advanced Edition Software. Disk parameters by emulation type Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 37
1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 Set optionally 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 XP Disk Array Configuration Guide for IBM AIX 37 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 38
CV1 uration of CV1 Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally 38 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 39
SCSI 96 96 96 15 15 15 10,016*n Depends on config- Depends on config- uration of CV1 uration of CV3 6,300 6,300 6,300 XP Disk Array Configuration Guide for IBM AIX 39 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 40
Set optionally Set optionally Set optionally Set optionally Set optionally 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 40 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 41
uration of CV3 6,300 6,300 6,300 Set optionally Set optionally Set optionally Set optionally Set optionally Set optionally 0 0 0 Set optionally Set optionally Set optionally XP Disk Array Configuration Guide for IBM AIX 41 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 42
8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1,024 1024 1,024 1,024 42 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 43
of cylinders of a Logical Unit Size Expansion (LUSE) composed of OPEN-x CVS volumes corresponds to the capacity specified by the SVP or the remote console. CVS size of OPEN-x is specified 4 = 212 The LUSE for the OPEN-3 CVS volume has 212 cylinders. XP Disk Array Configuration Guide for IBM AIX 43 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 44
4096 OPEN-L*2 to OPEN-L*3 8192 OPEN-L*4 to OPEN-L*7 16384 OPEN-3 CVS, OPEN-9 CVS, OPEN-E CVS, OPEN-V CVS 4096 Physical partition size table Table 15 Physical partition size Category LU product name OPEN-3 OPEN-3 Physical partition size in megabytes 4 44 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 45
-L OPEN-L*2 to OPEN-L*3 OPEN-L*4 to OPEN-L*7 35 to1800 1801 to 2300 2301 to 7000 7001 to 16200 Physical partition size in megabytes 8 16 32 64 128 8 16 32 64 128 256 8 16 32 64 128 256 16 32 64 128 256 64 128 256 2 4 8 16 XP Disk Array Configuration Guide for IBM AIX 45 - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 46
Category LU product name 13201 to 32400 32401 to 64800 64801 to 126000 126001 to 259200 259201 - 518400 518401 and higher Physical partition size in megabytes 32 64 128 256 512 1024 46 Disk array supported emulations - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 47
XP Continuous Access Software or XP Business Copy Software control operations which are then executed by the disk array. Control Unit. Contains LDEVs and is approximately equivalent to SCSI Target ID. Custom volume size. CVS devices (OPEN-x CVS) are custom volumes configured using array management - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 48
a single LDEV. The LUSE feature allows a LUN to be associated with 1 to 36 LDEVs. Essentially, LUSE makes it possible for applications to access a single large pool of storage. The LUSE feature is available when the HP StorageWorks XP Array Manager product is installed. Open Fibre Control. A general - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 49
. HP StorageWorks XP Command View Advanced Edition Software, installs on the user-provided Device Manager server and provides a browser-based platform from which you can manage the SVS 200 and the XP family of disk arrays-even globally distributed arrays. HP StorageWorks XP Remote Web Console - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 50
50 Glossary - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 51
verifying, 15 volume groups, 19 disk array(s) configuration, 10 connecting, 14 features, 7 installation overview, 9 Not Ready error message, 28 operating system versions, 7 self reboots, 27 server support, 7 storage capacity, 7 system requirements, 7 disk volume, calculating cylinders, 43 document - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 52
parity error, 28 path(s) defining, 15 worksheet, 31 physical volumes, cannot be created, 27 port(s) Fibre Channel, 12 R R-SIMS, 27 related documentation, 29 requirements, disk array, 7 S SCSI disk, Fibre Channel interface and term "SCSI disk", 8 security, LUN, 13 server, support, 7 SIMS, 27 storage - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 53
arrays storage capacity, 7 XP Business Copy Software, 9 XP Command View, 7, 9, 10, 12 XP Command View Advanced Edition Software, 7, 9, 10, 12 XP Continuous Access Software, 9 XP LUN Manager, 15 XP RAID Manager command devices, 9 XP Remote Web Console, 7, 9, 10, 12 Z zoning, fabric, 13 XP Disk Array - HP StorageWorks XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Gu - Page 54
54
HP StorageWorks
XP Disk Array Configuration Guide for IBM AIX
HP XP24000 Disk Array
nl
HP XP20000 Disk Array
nl
HP XP12000 Disk Array
nl
HP XP10000 Disk Array
nl
HP 200 Storage Virtualization System
Abstract
This guide provides requirements and procedures for connecting an XP disk array or SVS 200 to a host system,
and for configuring the disk array for use with the AIX operating system. This document is intended for system
administrators, HP representatives, and authorized service providers who are involved in installing, configuring,
and operating the HP XP storage systems.
Part number: A5951-96113
Fourteenth edition: January 2010