HP StoreOnce D2D4106i HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv
HP StoreOnce D2D4106i Manual
View all HP StoreOnce D2D4106i manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StoreOnce D2D4106i manual content summary:
- HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 1
HP StoreOnce D2D Backup System rack models nl service and maintenance guide Abstract This guide is intended for users who maintain the following rack-mounted models of the HP StoreOnce D2D Backup System: • HP D2D4324 G2 (12-disk) • HP D2D4312 G2 (12-disk) • HP D2D4112 and HP D2D4106 G2 (12-disk) • - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 2
Computer Software, Computer Software Documentation, and Technical Data for Commercial Items are licensed to the U.S. Government under vendor's standard commercial license. The information contained herein is subject to change without notice. The only warranties for HP products and services are - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 3
to the HP D2D 14 Software upgrades...14 2 The flash memory module 15 Overview...15 Part number...15 Identifying a flash memory module failure 15 Troubleshooting procedure 15 Replacing the memory module, G2 HP D2D Backup Systems only 15 Replacing the memory module, G1 HP D2D Backup Systems 17 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 4
Part numbers...40 P800 controller failure...40 Identifying a P800 card failure 40 Replacing the HP Smart Array P800 controller 41 Support and other resources 42 Related documentation...42 Document conventions and symbols 42 HP technical support...43 Customer self repair...43 Subscription service - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 5
HP D2D4106 Capacity Upgrade Kits are not described in this guide. Further information about these kits can be found in the Installation Instructions supplied with the kit. NOTE: The tower or desktop version of the HP D2D Backup System uses a different system architecture and has a different service - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 6
Smart Buy versions of the HP D2D2500 series Backup System are all G1 products. NOTE: There is a separate document for Gen2E products that were introduced after March 2012. This document is called: HP StoreOnce D2D Backup System maintenance and service guide Addendum for Gen2E models. 6 Introduction - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 7
models When using the HP ProLiant DL370 G6 guide, be aware of the following HP D2D-specific information: • The CPU is Intel Xeon W5680 (Kit part number 601315-B21 includes Heatsink) - there are two per system. • The HP D2D has 12 removable hard disks. The 12th disk is an online spare disk. If one of - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 8
models When using the HP ProLiant DL370 G6 guide, be aware of the following HP D2D-specific information: • The CPU is Intel Xeon W5580 (Kit part number 495928-B21 includes Heatsink) - there are two per system. • The HP D2D has 12 removable hard disks. The 12th disk is an online spare disk. If one of - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 9
is 500662-B21. • The HP D2D is supplied with an HP Smart Array P212/Zero Memory Controller (with 512 MB and BBWC) pre-installed in one of the full-height PCI-e slots. For more information about this card, search on http://www.hp.com/support/manuals. Part numbers are as follows: ◦ HP Smart Array P212 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 10
is 500662-B21. • The HP D2D is supplied with an HP Smart Array P212 controller (with 512 MB and BBWC) pre-installed in one of the full-height PCI-e slots. For more information about this card, search on http://www.hp.com/support/manuals. Part numbers are as follows: ◦ HP Smart Array P212/Zero Memory - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 11
• The HP D2D is supplied with an HP Smart Array P800 controller (with 512 MB and two BBWCs) pre-installed in one of the full-height PCI-e slots. For more information about this card, search on http://www.hp.com/support/manuals. Part numbers are as follows: ◦ P800 card: 398647-001 ◦ 512 MB memory: - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 12
with 512 MB and BBWC) pre-installed in one of the full-height PCI-e slots. For more information about this card, search on http://www.hp.com/support/manuals. Part numbers are as follows: ◦ P400 card: 441823-001 ◦ 512 MB memory: 405835-001 ◦ BBWC: 398648-001 ◦ BBWC cable assembly: 409125-001 • The FC - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 13
HP D2D is supplied with an HP Smart Array P400 controller (with 512 MB and BBWC) pre-installed. For more information about this card, search on http://www.hp.com/support/ manuals. ◦ P400 card: 441823-001 ◦ 512 MB memory: 405835-001 ◦ BBWC: 398648-001 ◦ BBWC cable assembly: 409125-001 HP D2D and HP - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 14
512 MB and BBWC) pre-installed. For more information about this card, search on http://www.hp.com/support/ manuals. ◦ P400 card: 441823-001 ◦ 512 MB memory: 405835-001 ◦ BBWC: 398648-001 ◦ BBWC cable assembly: 409125-001 POST messages and troubleshooting The HP D2D Web Management Interface is the - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 15
://www.hp.com or contact HP Support to find out which part number is required. Identifying a flash memory module failure Symptoms of problems with the memory module are: • The system hangs • Hosts cannot connect to the HP D2D Backup System via the Web Management Interface Troubleshooting procedure - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 16
to the latest version. This is done from the Web Management Interface (Settings/Software page), as described in the HP StoreOnce D2D Backup System User Guide. IMPORTANT: If your replacement flash stick is at a lower revision than the one it replaces, you may experience a message of "Devices Starting - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 17
Make sure both ends of the cable are connected securely. 4. Be sure to update the HP D2D software to the latest version. This is done from the Web Management Interface (Settings/Software page), as described in the HP StoreOnce D2D Backup System User Guide. IMPORTANT: If your replacement flash stick - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 18
Figure 11 HP D2D 4112, HP D2D4004 or HP D2D4009 G1 flash memory module Figure 12 HP D2D2500 G1 Series flash memory module 1 cable and USB connector to the memory module 2 screw and bracket securing USB cable connector 3 cable and connector to the motherboard 4 flash memory module 18 The flash memory - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 19
G2, refer to the appropriate Maintenance and Server Guide for detailed instructions on replacing the motherboard. This chapter describes the following tasks that are specific to HP D2D Backup Systems: • Set the J27 jumper on HP D2D4106/4112 G2 and HP D2D2502/2504 G2 products. • Update BIOS IDs on - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 20
unique to the system and can be used for any replacement Smart Array card (or HP D2D4312 motherboard). J27 settings (HP D2D4106/4112 G2 and HP D2D2502/2504 G2) NOTE: This section is not relevant for HP D2D4324/4312 models. The following diagram shows the location of the J27 jumper on the motherboard - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 21
Install the latest BIOS revision from the relevant product site. All BIOS revisions can be found at http://www.hp.com/support/downloads (under Storage - Disk Storage Systems - Disk to disk Backup - HP D2D Backup 1333 MHz Maximum Service Options Product Id (ignore M/B default warning displayed) - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 22
HP D2D Backup Systems (for USB Key-Media). 1. Download Setsys Utility for HP D2D Backup Systems (for USB Key-Media) from the relevant product site at http://www.hp.com/support/downloads (under Storage - Disk Storage Systems - Disk to disk Backup - HP D2D Backup Systems). 2. Follow the instructions - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 23
illustrates an alert for a failed RAID battery: This is a system generated message from your HP StoreOnce D2D Backup System Email Notification From AB4032 6-Jun-2008 8:08:15 : The RAID battery backup has failed For further information please browse to https://AB4032.emea.hpqcorp.net (https://16.26 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 24
D2D4324 Backup System. Each FBWC module has two single-color LEDs (green and amber). The LEDs are duplicated on the reverse side of the cache module to facilitate status viewing. See the HP Smart Array Controllers for HP ProLiant Servers User Guide for more information. 24 Battery/Flash Backed Write - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 25
two P411 controllers), and they are located in the holder in the center of the HP D2D4312 Backup System. See the HP Smart Array Controllers for HP ProLiant Servers User Guide for more information. NOTE: Follow the cable back to identify to which card the battery belongs. Figure 19 Battery pack LEDs - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 26
Figure 20 BBWC battery and P212 card, HP D2D4106/4112 G2 HP D2D2502/2504 G2 The P212 card has one BBWC. Figure 21 BBWC battery and P212 card, HP D2D2502/2504 G2 HP D2D4004/4009 and HP D2D2502/3/4 G1 The P400 card has one BBWC. 26 Battery/Flash Backed Write Cache (BBWC or FBWC) module failures - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 27
: Refer to the HP Smart Arrays for HP ProLiant Servers User Guide for the latest, detailed instructions on replacing a P800 cache battery and carefully follow the Caution and Warning advice. Figure 23 BBWC battery and P800 card 1 BBWCs Procedure 1. Remove the cover from the HP D2D Backup System, as - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 28
Smart Arrays for HP ProLiant Servers user guide". 3. Follow the instructions in the "HP Smart Arrays for HP ProLiant Servers user guide" to remove and dispose of the old battery and to replace it with the new one. 4. Replace the cover and power up the HP D2D. Check the status of the battery on the - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 29
the risk of personal injury or damage to the equipment, consult the safety information and user documentation provided with the server and RAID controllers before attempting the installation. HP D2D4312 The HP D2D4312 has three RAID controllers. • The P410i RAID controller is integral to the DL370G6 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 30
on this page also indicate a problem. If the HP SAS expander card is at fault, disks will not be visible on the Storage-Shelves tab NOTE: If RAID fails and the HP D2D Backup System is still functioning, you can also get information, including license keys, by generating a Support ticket (from the - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 31
is connected to the BBWC. (Follow the cables back to identify to which card each battery is connected.) 1. Power off the HP D2D Backup System. Remove the cover from the HP D2D, as described in the appropriate HP ProLiant Maintenance and Service guide, and locate the P411 controllers in PCI-e slots - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 32
appropriate HP ProLiant Maintenance and Service guide, and power on the HP D2D Backup System. HP SAS expander card (HP D2D4324 and D2D4312) If no disks are showing on the Storage-Shelves page of the D2D Web Management Interface, there may be a problem with the HP SAS expander card. The part number - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 33
Figure 27 Cabling showing the SAS expander card Figure 28 Cabling showing the backplanes HP SAS expander card (HP D2D4324 and D2D4312) 33 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 34
or damage to the equipment, consult the safety information and user documentation provided with the server and P212 controller before attempting the installation. Part numbers The required parts are: • HP Smart Array P212/Zero Memory Controller, part number 462828-B21 • 512 MB BBWC -Cache and BBWC - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 35
is powered off and, observing the safety and antistatic procedures documented in the HP ProLiant and HP Smart Arrays for HP ProLiant Servers user guides, remove the cover and PCI cage from the HP D2D and disconnect the failed card from the cable. Replace it with the new card (1) and secure it to the - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 36
P212 controller is seated properly and the cable to the BBWC is secure. 5. Replace the PCI cage and cover, as described in the appropriate HP ProLiant Maintenance and Service guide, and power on the HP D2D Backup System. 6. HP D2D4106/4112 Backup Systems only: Reinstate the SAAP license. a. Reboot - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 37
G1) Overview The following HP D2D Backup Systems use the HP SmartArray P400 RAID controller fitted with 512 MB RAM and one BBWC (battery backed write cache). • HP StoreOnce D2D4004 and D2D4009 G1 • HP StoreOnce D2D2500 series (HP D2D2502/3/4) G1 IMPORTANT: The HP D2D4112 G1 Backup System uses the - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 38
cable. 1. Power off the HP D2D backup System. Remove the cover and PCI cage from the HP D2D, as described in the appropriate HP ProLiant Maintenance and Service guide "HP Smart Arrays for HP ProLiant Servers user guide". Figure 35 Location of LEDs on the P400 controller card 3. Make sure the HP D2D - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 39
. Do not use the cable supplied with the replacement card. It is not long enough to connect to the BBWC. 5. Replace the PCI cage and cover, as described in the appropriate HP ProLiant Maintenance and Service guide, and power on the HP D2D Backup System. Replacing the HP Smart Array P400 controller - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 40
the equipment, consult the safety information and user documentation provided with the server and P800 controller before attempting the installation. Part numbers The replacement kit has a part number of 381513-B21. The component parts have the following part numbers: • P800 card: 398647-001 • 512 - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 41
replacing the P800 controller, refer to "HP Smart Arrays for HP ProLiant Servers User Guide". The replacement P800 controller is supplied without the BBWC batteries. The BBWCs must be removed from the failed board and installed on the replacement board. Instructions for doing this are also provided - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 42
Service guides • HP D2D4100 Series and D2D4300 Series Backup System Capacity Upgrade Kit Installation Instructions • HP StoreOnce D2D Backup System Best Practices for Performance Optimization You can find these documents from the Manuals page of the HP Business Support Center website: http://www.hp - HP StoreOnce D2D4106i | HP D2D Gen2 and Gen1 Backup Systems Maintenance and Serv - Page 43
self repair (CSR) programs allow you to repair your HP product. If a CSR part needs replacing, HP ships the part directly to you so that you can install it at your convenience. Some parts do not qualify for CSR. Your HP-authorized service provider will determine whether a repair can be accomplished
HP StoreOnce
D2D Backup System rack models
nl
service and maintenance guide
Abstract
This guide is intended for users who maintain the following rack-mounted models of the HP StoreOnce D2D Backup System:
•
HP D2D4324 G2 (12–disk)
•
HP D2D4312 G2 (12–disk)
•
HP D2D4112 and HP D2D4106 G2 (12–disk)
•
HP D2D2502 and 2504 G2 (4–disk)
•
HP D2D4112 G1 (12–disk)
•
HP D2D4004 G1 (6–disk)
•
HP D2D4009 G1 (12–disk)
•
HP D2D2502, 2503 and 2504 G1 (4–disk)
The architecture of these D2D Backup Systems is based upon established HP ProLiant and HP Smart Array RAID controller
products, which have their own user and service and maintenance guides. This document provides information on only those
aspects that are not covered in the existing guides.
Please note that there is a separate document for Gen2E products that were introduced after March 2012. This document is
called:
HP StoreOnce D2D Backup System maintenance and service guide Addendum for Gen2E models
.
HP Part Number: EH985-90937
Published: April 2012
Edition: Sixth