HP StoreVirtual 4335 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui
HP StoreVirtual 4335 Manual
View all HP StoreVirtual 4335 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP StoreVirtual 4335 manual content summary:
- HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 1
HP LeftHand Storage SRA for VMware SRM Deployment Guide HP Part Number: AX696-96210 Published: November 2012 Edition: 2 - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 2
© Copyright 2011, 2012 Hewlett-Packard Development Company, L.P. - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 3
TCP/IP connectivity, the protection site and the recovery site. The protection site is the site that is being replicated to the recovery site for disaster recovery. Each site contains HP LeftHand Storage, ESX servers, a Virtual Center Server, and an SRM server. Figure 1 Typical SRM configuration - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 4
in the SRM. Configuring HP LeftHand Storage arrays in the SRM requires the following: • The IP addresses of the SAN/iQ managers. More than two addresses can be input by using a comma or semicolon separator. • The same user name and password in each site. This is the administrative user name and - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 5
LUNs for the SRM to manage. Volumes that are being remote copied only manually are not updated consistently enough to be useful for disaster recovery and the SRM copies since they are usually created to clone a volume in the HP LeftHand Storage, and copies that reside on the same SAN are not useful - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 6
the SRA Table 1 Troubleshooting the SRA Problem Cause Solution The HP LeftHand Storage array does The SRA might not be installed or the Install the SRA and restart the VMware not appear in the drop down list of SRM service has not restarted since SRM Service. arrays for the SRM. the - HP StoreVirtual 4335 | 10.0 HP LeftHand StorageSRA for VMware SRM Deployment Gui - Page 7
2 Documentation feedback HP is committed to providing documentation that meets your needs. To help us improve the documentation, send any errors, suggestions, or comments to Documentation Feedback ([email protected]). Include the document title and part number, version number, or the URL when
HP LeftHand Storage SRA for VMware SRM
Deployment Guide
HP Part Number: AX696-96210
Published: November 2012
Edition: 2