HP Tc4100 hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters
HP Tc4100 - Server - 256 MB RAM Manual
View all HP Tc4100 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP Tc4100 manual content summary:
- HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 1
Fibre Channel topologies · Power distribution configuration Server Configuration Parameter Server Type Number of nodes Clock speed Number of CPUs BIOS CPU cache RAM Number of power supplies Specification HP Tower Server tc4100 Two Each node must be the same server type, but nodes may differ - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 2
order Local Storage Controller Driver Physical drive location Disk drives SCSI bus SCSI IDs System software Navigator CD-ROM Operating system Service pack HP Surestore Auto Path VA Specification Added cards may be installed in any appropriate slot, considering the server default boot order provided - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 3
FC connector Hubs or Switches Specification One or two per Virtual Array enclosure Consult your HP Reseller or HP storage specialist if planning configurations that may require support for additional MSCS clusters or additional non-clustered servers. 18 GB, 15K rpm, product numbers A6191A or A6228A - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 4
version from Navigator CD-ROM or HP technical support web site. For other NICs, any vendor-supported driver. Client LAN Configuration Parameter Network Connection NIC Quantity Model Driver Specification Any LAN One, minimum Any model that is on both the HP Tested Products List and the Microsoft - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 5
tc4100nt71-74 HP VA 7100 Dual HBA Cluster Public Network Server 1 Private Network Server 2 FC Hub/Switch FC Hub/Switch (LUN owner) Primary Active Path* Secondary Path for Failover *Preferred path mode only. 4/15/02 5 - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 6
tc4100nt71-74 HP VA 7400 Dual HBA Cluster Public Network Server 1 Private Network Server 2 FC Hub/Switch FC Hub/Switch HOST FC HOST FC (Redundancy Group1 owner) (Redundancy Group 2 owner) Primary path for RG 1* Secondary path for RG 2 *Preferred path mode only. Primary path for RG 2* - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 7
NL_Port optical fiber or copper cables optical fiber cable tc4100 Brocade Switch VA7X00 Brocade Switch tc4100 F_Port N_Port N_Port N_Port optical fiber cable Switched Fabric with Two Hubs or Switches and Two HBAs Supported Topologies for the HP tc4100, Virtual Array Cluster 4/15/02 7 - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 8
tc4100nt71-74 Power Cabling to Separate Power Circuits 4/15/02 8 - HP Tc4100 | hp tc4100 virtual array config guide for Microsoft NT 4.0 Clusters - Page 9
Versions 15 April 2002 01 April 2002 Updated topology diagram. Initial release tc4100nt71-74 ãCopyright 2002, Hewlett-Packard Company 4/15/02 9
HP Tower Server tc4100 with
HP Surestore Virtual Array 7100/7400
Windows NT
±
4.0 Enterprise Edition
Cluster Configuration Guide
Introduction
This document defines the server cluster configurations supported by Hewlett-Packard for interconnection of
two HP tc4100 servers and one HP VA 7100 or 7400 disk drive enclosure, with Microsoft
±
Cluster Server
software.
These configurations provide high server cluster availability and minimize single points of failure
(SPOFs).
Hewlett-Packard will support any cluster configuration that conforms to the guidelines of this
document.
Deviations from the supported configurations can result in an inoperative cluster, an operating
cluster with degraded performance, or hidden SPOFs.
Therefore, deviations are not supported.
For
revision/update information on this document, refer to
Versions
on page 9.
Cluster Configuration Elements
This section identifies the hardware components, system software, network interfaces, and power distribution
arrangement required to build an operational server cluster supported by Hewlett-Packard.
The various
server cluster elements are listed below, and their associated configuration data is detailed in separate tables
and illustrations that follow.
±²
Server configuration
±²
Shared storage configuration
±²
Intra-cluster (heartbeat) LAN configuration
±²
Client LAN configuration
±²
FC cabling configuration
±²
Supported Fibre Channel topologies
±²
Power distribution configuration
Server Configuration
Parameter
Specification
Server
Type
HP Tower Server tc4100
Number of nodes
Two
Each node must be the same server type, but nodes may differ in their CPU clock
speeds and cache sizes, and amounts of main memory.
Clock speed
1.40 GHz, or any CPU within the same processor family
Number of CPUs
Two
BIOS
Version 4.06.12 RI, or later
CPU cache
Any size
RAM
Recommended 512 MB, minimum.
Must be HP.
Number of power
supplies
One standard, two required for redundancy
4/15/02
1