HP XP1024 HP StorageWorks Disk Array XP operating system configuration guide:
HP XP1024 Manual
View all HP XP1024 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP XP1024 manual content summary:
- HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 1
HP StorageWorks Disk Array XP operating system configuration guide: Linux XP12000 XP10000 XP1024 XP128 This guide describes the requirements and procedures for connecting the XP family of disk arrays to a Linux system and configuring the new disk array for operation with Linux. Part number: A5951- - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 2
. HP shall not be liable for technical or editorial errors or omissions contained herein. Microsoft, Windows, Windows XP, and Windows NT are U.S. registered trademarks of Microsoft Corporation. Linux is a U.S. registered trademark of Linus Torvalds. Disk Array XP operating system configuration guide - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 3
Contents Preface 5 About this guide 5 Intended audience 5 Disk arrays 5 Related documentation 5 Document conventions and symbols 6 HP technical support 7 Subscription service 7 Other HP web sites 7 1 Installation 9 Features and requirements 9 Fibre Channel interface 10 Device emulation - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 4
the mount table 25 Verifying file system operation 25 2 Troubleshooting 27 Error conditions 27 Calling the HP support center 28 Contact information 28 Before you call 29 A Path worksheet 31 B Disk array supported emulations 33 Supported emulations 33 Emulation specifications 34 Glossary 37 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 5
Array XP128: Owner's Guide • HP StorageWorks Disk Array XP1024: Owner's Guide • HP StorageWorks XP10000 Disk Array: Owner's Guide • HP StorageWorks XP12000 Disk Array: Owner's Guide You can find these documents on the storage web site: http://h18006.www1.hp.com/storage/xparrays.html Disk Array XP - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 6
Document conventions and symbols Convention Blue text Bold Italics Blue, underlined: www.hp.com [http:// www.hp.com] Monospace font Monospace, italic font Web site addresses • File and directory names • System output • Code • Commands, their arguments, and argument values • Code variables • Command - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 7
by selecting Business support and then Storage under Product Category. Other HP web sites For additional information, see the following HP web sites: • http://www.hp.com/go/storage • http://www.hp.com/support/ • http://www.hp.com/service_locator • http://www.docs.hp.com Disk Array XP operating - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 8
8 Preface - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 9
. Refer to the adapter documentation for installation details • (Recommended) HP StorageWorks Remote Web Console XP, Command View XP Advanced Edition or Command View XP with LUN management feature for configuring disk array ports and paths • (Recommended) HP StorageWorks LUN Configuration and Security - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 10
Cache LUN XP HP StorageWorks Auto Path XP HP StorageWorks Cluster Extension XP HP StorageWorks Performance Advisor XP Fibre Channel interface The XP family of disk arrays supports these Fibre Channel elements: • Connection speed of 1 Gbps and 2 Gbps • Short-wave non-OFC (open fiber control) optical - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 11
SVP but they can also be set remotely using Remote Web Console XP, Command View XP, or Command View XP Advanced Edition. Refer to the applicable user's guide for procedures. RAID Manager command devices RAID Manager manages Business Copy (BC) or Continuous Access (CA) operations from a host server - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 12
Install and configure the disk array The HP service representative performs these tasks: • Assembling hardware and installing software • Loading the microcode updates • Installing and formatting devices After these tasks are finished, you will use Remote Web Console, Command View, Command View XP - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 13
for the disk array ports After the disk array is installed, you must set the host mode for each disk array port to match the host OS. Set the host mode using LUN Manager in Remote Web Console XP (shown), Command View XP, or Command View XP Advanced Edition. If these are not available, the HP service - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 14
For the XP1024/XP128 arrays, the host mode can also be set at the port information window in Command View XP AE. Setting the System Option Modes The HP service representative sets the System Option Mode(s) based on the operating system and software configuration of the host. 14 Installation - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 15
is represented in the device list for HP-UX. Configuring the Fibre Channel ports Configure the disk array Fibre Channel ports by using Remote Web Console (shown), Command View, or Command View XP AE. Select the settings for each port based on your storage area network topology. Use switch zoning if - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 16
and Connection parameter settings Set each array port to FABRIC ON or OFF with connections of POINT-TO-POINT or FC-AL as shown in the following figures and table. For detailed topology information, refer to the HP StorageWorks SAN Design Reference Guide on the www.hp.com web site. 16 Installation - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 17
host to the disk array. Loading the OS and software Follow the manufacturer's instructions to load the operating system and software onto the host. Load all OS patches and configuration utilities supported by HP and the HBA manufacturer. Disk Array XP operating system configuration guide: Linux 17 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 18
's instructions. On Linux systems, the disk array only supports QLogic and Emulex adapters. Contact your HP service representative for the latest information about supported HBAs. Clustering and fabric zoning If you plan to use clustering, install and configure the clustering software on the servers - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 19
present in the SAN) LUN Security Must be used when multiple hosts connect through a shared port Must be used when multiple cluster nodes connect through a shared port Must be used when multiple cluster nodes connect through a shared port Disk Array XP operating system configuration guide: Linux 19 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 20
all devices. 4. Power on the Linux server. Defining the paths Use Remote Web Console (shown), Command View, or Command View XP AE to define paths (LUNs) between hosts and volumes in the disk array. This process is also called "LUN mapping." In Remote Web Console and Command View, LUN mapping includes - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 21
, and LDEVs for later use in verifying host and device configuration. Verifying new device recognition 1. Verify that the HBA driver is installed using the lsmod command. 2. View the device information in the the /proc/scsi/scsi file. Disk Array XP operating system configuration guide: Linux 21 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 22
HP Model: OPEN-9 Rev: 2105 Type: Direct-Access ANSI SCSI revision: 02 Host: scsi0 Channel: 00 Id: 00 Lun: 02 Vendor: HP HP Model: OPEN-9 Rev: 2105 Type: Direct-Access ANSI SCSI revision: 02 3. Verify that the system recognizes the disk array partitions by viewing the XP disk partitions and - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 23
complete the fdisk command. 5. Other commands that you might want to use include: d to remove partitions q to stop a change 6. Repeat the above steps for each device. Creating the file systems The supported file system for Linux is ext2. Disk Array XP operating system configuration guide: Linux 23 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 24
-t ext2 /dev/device_name. Example # mkfs -t ext2 /dev/sdd 2. Repeat step 1 for each device on the disk array. Creating the mount directories Create mount directories using the mkdir command. Choose names for the mount directories which identify both the logical volume and partition. 1. Enter mkdir - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 25
the editor. 2. Reboot the system. 3. Display the mounted devices using the df -h command and verify that the devices were automounted. Example # df -h Filesystem Size Used Avail Verify file system operation by copying a file to each device. Disk Array XP operating system configuration guide: Linux 25 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 26
26 Installation - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 27
for assistance. See Calling the HP support center. Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: • In Remote Web Console (Status tab) • In Command View Advanced Edition ("Alerts" panel). • In Command View (Event History or Event - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 28
self reboot because the disk array was busy or it logged a panic message. Reboot the host. The disk array responds "Not Ready" or the Contact HP. disk array has displayed "Not Ready" and timed out. The host detects a parity error. Check the HBA and make sure it was installed properly. Reboot the - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 29
information available: • Technical support registration number (if applicable) • Product serial numbers • Product model names and numbers • Applicable error messages • Operating system type and revision level • Detailed, specific questions Disk Array XP operating system configuration guide: Linux 29 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 30
30 Troubleshooting - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 31
A Path worksheet LDEV (CU:LDEV) (CU = Device control unit) Type 0:00 0:01 0:02 0:03 0:04 0:05 0:06 0:07 0:08 0:09 0:10 0:11 0:12 0:13 : LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: LUN: Disk Array XP operating system configuration guide: Linux 31 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 32
32 Path worksheet - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 33
XP Model Emulation Supported LUSE CVS OPEN-3 Yes Yes Yes OPEN-8 Yes Yes Yes XP128 OPEN-9 Yes Yes Yes XP1024 OPEN-E Yes Yes Yes XP10000 OPEN-K XP12000 OPEN-L Yes Yes OPEN-M OPEN-V Yes Yes LUSE & CVS Yes Yes Yes Yes Disk Array XP operating system configuration guide: Linux - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 34
96 15 96 15 96 15 96 15 128 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 *Capacity = (512 x number of blocks) ÷ 10242 34 Disk array supported emulations - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 35
-3 CVS volume with capacity = 37 MB: # of cylinders = ↑37 × 1024/720↑ = ↑52.62↑ (rounded up to next integer) = 53 cylinders OPEN-V: The number of cylinders for a CVS volume = # of cylinders = ↑ (capacity (MB) specified by user) × 16/15 ↑ Disk Array XP operating system configuration guide: Linux 35 - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 36
cylinders = ↑ (capacity (MB) specified by user) × 1024/720 ↑ × n Example For a CVS LUSE volume with capacity = 37 MB and n = 4: # of cylinders = ↑37 × 1024/720↑ × 4 = ↑52.62↑× 4 = 53 × size using Remote Web Console, Command View or Command View Advanced Edition. 36 Disk array supported emulations - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 37
Business Copy XP. BC lets you maintain up to nine local copies of logical volumes on the disk array. CA HP StorageWorks Continuous Access XP. CA lets you create and maintain duplicate copies of local logical volumes on a remote disk array. Command View (CVXP) HP StorageWorks Command View XP - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 38
only a single LDEV. The LUSE feature allows a LUN to be associated with 1 to 36 LDEVs. Essentially, LUSE makes it possible for applications to access a single large pool of storage. The LUSE feature is available when the HP StorageWorks LUN Configuration Manager product is installed. 38 Glossary - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 39
disks. remote console PC The PC running HP StorageWorks Remote Control XP. Remote Control (RC) HP StorageWorks Remote Control XP. A software product used for managing XP arrays. Remote Web Con- HP StorageWorks XP Remote Web Console. A browser-based sole (RWC) program installed on the SVP - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 40
; one is identified as CU = 00 and LDEV = 00, and the other as CU = 01 and LDEV = 00; they are two unique separate virtual storage devices within the XP array. Volume size customization. Synonymous with CVS. World Wide Name. A unique identifier assigned to a Fibre Channel device. 40 Glossary - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 41
, 34 disk array(s) connecting, 20 device emulations, 33 features, 9 installation overview, 12 Not Ready error message, 28 operating system versions, 9 requirements, 9 self reboots, 28 server support, 9 storage capacity, 9 document, 5 document conventions, 6 documentation HP web sites, 5 E emulation - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 42
12 storage web site, 7 Subscriber's Choice web site, 7 technical support, 7, 28 I installation connecting disk array, 20 HP service representative tasks, 12 overview, 12 procedures, 12 interface, Fibre Channel, 10 L LDEV(s) designate at least one as a command device, 11 Linux partitions, 11 server - HP XP1024 | HP StorageWorks Disk Array XP operating system configuration guide: - Page 43
documentation, 5 Remote Web Console, 9, 11, 12, 20 requirements and features, 9 Resource Manager XP, 10 S SCSI disk, Fibre Channel interface and term "SCSI disk", 10 Secure Manager XP, 19 security, LUN, 18, 19 server restarting, 20 support, 9 SNMP configuration, 11 software, optional, 9 storage
HP StorageWorks
Disk Array XP operating system
con
fi
guration guide: Linux
XP12000
XP10000
XP1024
XP128
This guide describes the requirements and procedures for connecting the XP family of disk arrays to a
Linux system and con
fi
guring the new disk array for operation with Linux.
Part number: A5951–96094
Seventh edition: (November 2005)