- HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 1
HP StorageWorks XP Disk Array Configuration Guide: Solaris HP XP24000 Disk Array nl HP XP20000 Disk Array nl HP XP12000 Disk Array nl HP XP10000 Disk Array nl HP 200 Storage Virtualization System Abstract This guide provides requirements and procedures for connecting an XP disk array or SVS 200 to a - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 2
Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 3
configuring the FCAs 15 WWN ...15 Setting the disk and device parameters 16 Configuring FCAs with Troubleshooting 27 Error conditions ...27 3 Support and other resources 29 Contacting HP ...29 Subscription service ...29 Related information ...29 HP websites ...30 XP Disk Array Configuration Guide - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 4
Conventions for storage capacity values 30 HP product documentation survey 30 A Disk array supported emulations 31 Supported emulations ...31 Emulation specifications ...31 B Using Veritas Cluster Server to prevent data corruption 35 Using VCS I/O fencing ...35 Glossary 39 Index 43 4 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 5
Figures 1 SNMP configuration 9 2 Point-to-point fabric topology example 15 3 Multi-cluster environment 22 4 Nodes and ports ...36 XP Disk Array Configuration Guide: Solaris 5 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 6
Tables 1 Host group modes (options 12 2 Fabric topology settings 15 3 Max throttle (queue depth) requirements for the devices 16 4 Error conditions ...27 5 Supported emulations 31 6 Emulation specifications 31 7 Port 1A Key Registration Entries 37 8 Port 2A Key Registration Entries 37 6 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 7
from the HP service representative. Features and requirements The disk array has the following features: • Storage capacity: The storage capacity for each model is listed below: Model Maximum drives Maximum Capacity Maximum FC ports XP24000 1152 2.26 PB 224 4GB or 24 8GB XP20000 240 472 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 8
• HP StorageWorks XP Remote Web Console or HP StorageWorks P9000 or XP Command View Advanced Edition Software for configuring disk array ports and paths. • HP StorageWorks XP Array Manager. • Check with your HP representative for other XP software available for your system. Fibre Channel interface - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 9
also be set remotely using P9000 or XP Command View Advanced Edition Software or XP Remote Web Console. For specific procedures, see the applicable user guide. Figure 1 SNMP configuration . RAID Manager command devices HP StorageWorks P9000 RAID Manager Software manages HP StorageWorks XP Business - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 10
After these tasks are finished, use XP Remote Web Console, P9000 or XP Command View Advanced Edition Software, or XP Array Manager to complete the remaining disk array configuration tasks. If you do not have these programs, your HP service representative can perform these tasks for you. Defining - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 11
set the host mode for each host group that is configured on a disk array port to match the host OS. Set the host mode using LUN Manager in XP Remote Web Console (shown) or P9000 or XP Command View Advanced Edition Software. The host mode setting for Solaris is 09. XP Disk Array Configuration Guide - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 12
added, additional host group modes (options) may be configured. The storage administrator must verify if an additional host group mode is required for the host group. For Solaris, host group mode 7 should always be set because this is a prerequisite when using the Sun SAN driver. The disk arrays - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 13
or XP Command View Advanced Edition Software or XP Remote Web Console (shown). Select the settings for each port based on your storage area network topology. Use switch zoning if you connect different types of hosts to the array through the same switch. XP Disk Array Configuration Guide: Solaris 13 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 14
see the HP StorageWorks XP24000/XP20000 LUN Manager User Guide applicable to your array. Fabric and connection parameter settings Set each array port to HP StorageWorks SAN Design Reference Guide at: http://www.hp.com/go/sandesign 14 Installing and configuring Solaris for the XP family of disk arrays - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 15
and configure Fibre Channel adapters (FCAs) that connect the host to the disk array. Loading the operating system and software Follow the manufacturer's instructions to load the operating system and software onto the host. Load all OS patches and configuration utilities supported by HP and the FCA - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 16
XP20000, XP24000: Queue_depth 2048 default. CAUTION: The number of issued commands must be completely controlled. Because queuing capacity of the disk array is either 1024 or 2048 per port (depending on the disk array also need to set several other parameters (such as FC fibre support). See the user - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 17
supported with the Sun SAN driver stack. The Sun SAN driver stack also supports current Emulex and Qlogic FCAs. NOTE: Ensure host group mode 7 is set for the XP array and Configuration Guide or Solaris Fibre Channel and Storage Multipathing Administration Guide, and HP StorageWorks MPxIO for Sun - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 18
17. To determine which Emulex FCAs and driver version HP supports with the lpfc driver, contact your HP representative. The lpfc driver is not supported on x86 architecture. Configure Emulex FCAs with the lpfc driver as follows: 18 Installing and configuring Solaris for the XP family of disk arrays - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 19
set Manager/Sun Storage Multipathing. To HP representative to determine which QLogic FCAs and driver version HP supports with the qla2300 driver. The qla2300 driver is not supported on x86 architecture. Configure Qlogic FCAs with the qla2300 driver as follows: XP Disk Array Configuration Guide - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 20
hardware and software products. HP recommends to migrate to different FCAs. Support is limited to legacy environments with Solaris 8 and 9 only. Configure 2 Gbit FCAs differently as explained below. For 1 Gbit FCAs, see the HP StorageWorks XP12000 Disk Array Configuration Guide for Sun Solaris. AMCC - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 21
AMCC/JNI 2 Gbit FCAs • Use JNIC146x driver (version 5.3.1.1). • Edit the FCA driver settings in the /kernel/drv/jnic146x.conf file. For a SAN environment: FcLoopEnabled = 0; FcFabricEnabled = 1; and configure the clustering software on the servers. XP Disk Array Configuration Guide: Solaris 21 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 22
XP Array Manager for the XP24000/XP20000 disk array offer the ability to limit access to a given host to a specific host/WWN. • Security must be enabled for LUN isolation when multiple hosts connect through a shared array port. See the HP StorageWorks SAN Design Reference Guide (http://www.hp.com - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 23
devices. If any devices are missing or if no array devices are shown, check the following: • SAN (zoning configuration and cables) • Disk array path configuration (FCA HBA WWNs, host group 09 and host group mode 7 set, and LUNs defined for the correct array ports) Verify that host group 09 and host - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 24
1. If you want to create a file system, create a file system of your choice on the given disks. For the various file systems you can set specific parameters that can have an impact on performance and are application-dependant. 24 Installing and configuring Solaris for the XP family of disk arrays - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 25
HP XP disk arrays are certified for VxVM support. Be sure to set the driver parameters correctly when you install the FCA. Failure to do so may result in a loss of path failover in DMP. See "Installing and configuring the FCAs" on page 15 and the FCA manufacturer's instructions for setting specific - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 26
install the ASL from the Symantec/Veritas support website (http://support.veritas.com): 1. Select Volume Manager for Unix/Linux as product and search the XP array model for Solaris as the platform. 2. Read the TechFile that appears and follow the instructions to download and install the ASL. After - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 27
HP support representative for assistance. Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: • In XP Remote Web Console per port has not been exceeded. • The disk array host mode is set correctly. The host does not reboot properly - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 28
Error condition Recommended action The disk array responds "Not Ready" Contact HP. or the disk array has displayed "Not Ready" and timed out. The host host hangs. Make sure there are no duplicate disk array TIDs and that disk array TIDs do not conflict with any host TIDs. 28 Troubleshooting - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 29
Disk Array: Owner's Guide • HP StorageWorks XP12000 Disk Array: Owner's Guide • HP StorageWorks XP24000/XP20000 Disk Array Owner's Guide • HP StorageWorks 200 Storage Virtualization System Owner's Guide. • HP StorageWorks XP LUN Manager User's Guide • HP StorageWorks SAN Design Reference Guide • HP - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 30
websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/support/manuals • http://www.hp.com/storage/spock Conventions for storage capacity values HP XP storage systems use the following values to calculate physical storage capacity values (hard disk drives): • 1 KB (kilobyte - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 31
Yes Yes NOTE: For the SVS 200, and the XP24000/XP20000/XP12000/XP10000 when connected to external storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host. This allows configuration of external storage LDEVs without losing data. Using any other emulation may - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 32
Note 5 512 Note 6 512 Note 6 512 Note 6 512 Note 6 512 Note 6 SCSI disk SCSI disk SCSI disk SCSI disk SCSI disk OPEN-3*n-CVS OPEN-8*n-CVS OPEN-9*n-CVS OPEN-E*n-CVS OPEN-V*n Note 5 Note 5 Note 5 Note 5 The availability of an emulation depends on the disk array. 32 Disk array supported emulations - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 33
) specified by user) × 1024/720 × n Example For a CVS LUSE volume with capacity = 37 MB and n = 4: # of cylinders = 37 × 1024/720 × 4 = 52.62 × 4 = 53 × 4 = 212 XP Disk Array Configuration Guide: Solaris 33 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 34
is specified in MB, not number of cylinders. The capacity of an OPEN-V CVS volume can be specified in MB or number of cylinders. You set the volume size using XP Remote Web Console or P9000 or XP Command View Advanced Edition Software. 34 Disk array supported emulations - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 35
different ports. The maximum number of reserve keys that can be registered per port for each disk array is 128. Attempts to add additional registration keys will fail if the number exceeds this limit. , the number of registration keys will be equal to 4. XP Disk Array Configuration Guide: Solaris 35 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 36
Figure 4 Nodes and ports . 36 Using Veritas Cluster Server to prevent data corruption - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 37
2 - Disk Group 1 8, 9 - Disk Group 3 0, 1, 2 - Disk Group 1 4, 5,6 - Disk Group 2 - : - WWN visible to Port-2A LU - Disk Group WWNa1 WWNa1 WWNb1 WWNb1 - : - 0, 1, 2 - Disk Group 1 4, 5, 6 - Disk Group 2 0, 1, 2 - Disk Group 1 8, 9 - Disk Group 3 - : - XP Disk Array Configuration Guide: Solaris - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 38
38 Using Veritas Cluster Server to prevent data corruption - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 39
FC-AL FCP FSC HBA HDLM Arbitrated loop physical address. Array Support Libraries. A volume on the disk array that accepts HP StorageWorks Continuous Access or HP StorageWorks Business Copy control operations which are then executed by the array. Control unit. Custom volume size. CVS devices (OPEN - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 40
693 MB. Logical Unit Size Expansion. The LUSE feature is available when the HP StorageWorks LUN Manager product is installed, pool of storage. Open Fibre Control. A general term describing any one of the supported OPEN a disk array. Redundant array of independent disks. Remote service information - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 41
and the other as CU = 01 and LDEV = 00; they are two unique separate virtual storage devices within the array. Volume size customization. Also known as CVS. Veritas Volume Manager. World Wide Name. A unique identifier assigned to a Fibre Channel device. XP Disk Array Configuration Guide: Solaris 41 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 42
42 Glossary - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 43
(s) configuring, 15 Emulex, 18 JNI, 20 Qlogic, 19 Sun, 17 supported, 15 verifying configuration, 21 features, disk array, 7 Fibre Channel connection speed, 8 interface, 8 ports, configuring, 14 supported elements, 8 Fibre Channel adapters, see "FCAs", 7 XP Disk Array Configuration Guide: Solaris 43 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 44
, disk array, 7 S SCSI disk, Fibre Channel interface and term "SCSI disk", 8 security, LUN, 22 server(s), supported, 7 SIMS, 27 storage capacity, 7 storage capacity values conventions, 30 Subscriber's Choice, HP, 29 system option mode, setting, 13 T technical support, 30 HP, 29 troubleshooting - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 45
XP arrays storage capacity, 7 XP Business Copy Software, 9 XP Continuous Access Software, 9 XP LUN Manager, 10 XP Remote Web Console, 8, 9, 10, 13 Z zoning, fabric, 22 XP Disk Array Configuration Guide: Solaris 45 - HP XP20000/XP24000 | HP StorageWorks XP Disk Array Configuration Guide: Solaris - Page 46
46
HP StorageWorks
XP Disk Array Configuration Guide: Solaris
HP XP24000 Disk Array
nl
HP XP20000 Disk Array
nl
HP XP12000 Disk Array
nl
HP XP10000 Disk Array
nl
HP 200 Storage Virtualization System
Abstract
This guide provides requirements and procedures for connecting an XP disk array or SVS 200 to a host system,
and for configuring the disk array for use with the Solaris operating system. This document is intended for system
administrators, HP representatives, and authorized service providers who are involved in installing, configuring,