HP XP20000/XP24000 HP StorageWorks MPX200 Multifunction Router User Guide (569
HP XP20000/XP24000 Manual
View all HP XP20000/XP24000 manuals
Add to My Manuals
Save this manual to your list of manuals |
HP XP20000/XP24000 manual content summary:
- HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 1
HP StorageWorks MPX200 Multifunction Router User Guide This user guide describes the MPX200 Multifunction Router, which supports the EVA and XP families of Fibre Channel storage of HP StorageWorks EVA4x00/6x00/8x00 and XP24000/20000 storage systems, configuring LUNs using HP Command View, HP Fibre - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 2
Hewlett-Packard Development Company, L.P. Confidential computer software. Valid license from HP required HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 3
53 iSCSI rules and supported maximums 53 EVA storage system rules and guidelines 54 HP Command View EVA management rules and guidelines 54 EVA storage system software ...55 Features supported for iSCSI hosts 55 Features not supported for iSCSI hosts 55 MPX200 Multifunction Router User Guide 3 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 4
Supported IP network adapters 60 IP network requirements ...60 Setting Setting up SNP for the HP NC3xxx Multifunction Gigabit server adapter 70 iSCSI initiator setup for Apple Mac OS X (single-path 70 Setting up the iSCSI initiator for Apple Mac OS X 70 Setting up storage initiator services and - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 5
HP support 130 Storage system rules and guidelines 130 Fibre Channel switch and firmware support 138 Step 5. Set the MPX200 settings 141 Configure the FCIP routes using the CLI 141 Step 7. Configure FC switch settings Setting up for FCoE connectivity 146 8 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 6
157 Troubleshooting using HP Command View EVA 157 Issues and solutions ...158 HP Command HP Command View EVA issues and solutions 161 9 Support and other resources 163 Intended audience ...163 Related documentation ...163 Contacting HP ...163 HP technical support ...163 Subscription service - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 7
Set ...182 Set alias ...183 Set CHAP ...184 Set chassis ...184 Set FC ...185 Set features ...186 Set iSCSI ...186 Set iSNS ...186 Set Mgmt ...187 Set NTP ...188 Set properties ...188 Set SNMP ...188 Set system ...189 Set restoring router configurations 213 MPX200 Multifunction Router User Guide 7 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 8
notification ...232 Generic notification ...233 D Log messages 235 E HP StorageWorks mpx100/mpx100b to MPX200 Upgrade 259 To upgrade from mpx100/mpx100b 263 Korean notices ...264 Safety notices ...264 Battery replacement notice 264 Taiwan battery recycling notice 265 Power cords ...265 Japanese - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 9
MPX200 configuration 271 Saving the configuration using MPX200 CLI 271 Restoring the configuration using MPX200 CLI 272 Glossary 273 Index 277 MPX200 Multifunction Router User Guide 9 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 10
folder properties 37 21 Host properties ...38 22 iSCSI controller properties: Mgmt Port tab 39 23 iSCSI controller properties: IP Ports tab 40 24 Set iSCSI controller time 41 25 Code Load page for the iSCSI controller 42 26 iSCSI controller shutdown options 42 27 iSCSI controller configuration - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 11
38 Expanded ports ...51 39 Select the Initiators 52 40 Installing the Windows Server 2003 kit 61 41 Installation Wizard 61 42 iSCSI initiator properties: Discovery tab 62 43 Adding a host ...63 44 Virtual disk properties 64 45 Host details ...64 46 Targets tab ...65 47 Select Features page 67 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 12
long-distance links 122 86 MPX200 configuration with remote IP Distance gateway (mpx110 123 87 MPX200 highly Setting IP addresses 140 97 FCIP License Add 140 98 FCoE end-to-end direct-connect EVA storage configuration 145 99 FCoE end-to-end fabric-connect EVA storage configuration 146 100 HP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 13
Using the beacon on command to locate an MPX200 blade 156 111 Using HP Command View EVA to locate a hardware device 156 112 FCIP route ping 158 114 iSCSI controller properties: IP Ports tab 159 115 Virtual disk properties: Host details 160 116 iSCSI initiator properties: Targets tab 160 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 14
configuration maximums 25 4 Supported MPX200 iSCSI maximums 54 5 Support for EVA storage system software with MPX200 iSCSI 56 6 EVA operating system and multipath software support 56 7 MPX200-XP operating system and multipath support 57 8 Supported IP network adapters 60 9 Differences between - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 15
migration capabilities are available for use. For more information on data migration, see the HP StorageWorks MPX200 Multifunction Router Data Migration Solution Guide. The MPX200 is available from HP factory-integrated with an EVA or XP24000/20000 storage system or as a field upgrade to an existing - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 16
and two 8-Gb/s FC ports • rail kit • accessory kit • documentation • redundant power supplies Up to four EVA storage systems, or order separately to upgrade existing EVA storage systems AP772A AP773A HP StorageWorks MPX200 1GbE Upgrade Blade HP StorageWorks MPX200 10-1GbE Base Chassis • one - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 17
HP Storage Works MPX200 5TB Full Chassis Data Migration License HP Storage Works MPX200 Full Chassis 1 Array Data Migration License HP Storage Works MPX200 Full Chassis 3 Array to a single array using a MPX200 Chassis. Includes the license to migrate data from or to a single array on three unique - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 18
10-GbE SFP+ 5m Direct Attach Cable XBR-TWX-0501 (AP820A) For FC switch model support, see Chapter 5 and the SPOCK website at http://www.hp.com/storage/ spock. MPX200 configuration options for EVA You can configure an EVA storage system for simultaneous connectivity to iSCSI and FC attached hosts - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 19
may require reconfiguration of device mappings. Figure 2 MPX200 dual-blade fabric-attached configuration . Figure 3 illustrates a multi-EVA configuration with connectivity for up to four EVA storage systems from a single MPX200 blade. MPX200 Multifunction Router User - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 20
Figure 3 MPX200 single-blade multi-EVA configuration . Figure 4 illustrates a multi-EVA configuration with connectivity for up to four EVA storage systems from dual MPX200 blades. This configuration provides high availability with failover between blades. Figure 4 MPX200 dual-blade multi-EVA - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 21
EVA storage system FP1 FP2 A B FP1 FP2 26639a Figure 5 MPX200 dual-blade direct connect to one EVA configuration . MGMT HP StorageWorks MPX200 XP24000/20000 An XP storage system can be configured for simultaneous connectivity to iSCSI and FC attached hosts. Support for iSCSI to an XP storage - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 22
with failover between blades. Figure 9 MPX200-XP dual-blade fabric-attached configuration . Figure 10 shows a multi-XP configuration with connectivity for up to four XP storage systems from a single MPX200 blade. 22 MPX200 Multifunction Router overview - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 23
Figure 10 MPX200-XP multi-XP fabric-attached configuration . MPX200 Multifunction Router User Guide 23 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 24
• Use of Internet Storage Name Service (iSNS) • Use services) configurations are always configured for separate operation. NOTE: For more information on data migration, see the HP StorageWorks MPX200 Multifunction Router Data Migration Solution Guide. Table 3 describes the MPX200 supported - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 25
configurations that include one 1-GbE blade and one 10-GbE blade, the supported maximums are the 1-GbE values. 210-GbE ports only 3For iSCSI Each initiator, therefore, discovers four times the number of FC targets. HP recommends that you use iSNS to present to the initiator only the Guide 25 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 26
iSCSI provides a mechanism to allocate FC bandwidth to each function. 10-GbE initiators HP recommends that you map servers with 10-GbE NICs for login to the 10-GbE (CHAP) on the MPX200. CHAP is a security protocol that supports the bidirectional (mutual) authentication option and the one-way (target - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 27
chassis in an environment that is compatible with the maximum ambient rated temperature. MPX200 components Figure 11 shows the MPX200 components. MPX200 Multifunction Router User Guide 27 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 28
1. Rack rail, inner (2) 3. Chassis rail (2) 5. Screw, flathead, 10-32 x 1/4 in. (6) 7. Washer, centering (10); for use on racks with square holes only 2. Rack rail, outer (2) 4. Screw, flathead, 6-32 x 1/4 in. (8) 6. Screw, panhead, 10-32 x 3/8 in. (10) Figure 11 MPX200 components . Rack mounting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 29
using four 6-32 x 1/4 in. screws (Figure 13). 1. Rear rack rail 3. Screw, flathead, 6-32 x 1/4 in. Figure 13 Rack rails . 2. Front rack rail MPX200 Multifunction Router User Guide 29 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 30
3. Install the rails in the rack. There are two inner rails and two outer rails. Slide each inner rail into the corresponding outer rail to create a complete rack rail. a. Extend the rack rails to fit the inner dimensions of the rack. The rail flanges on both ends fit inside the rack. b. Make sure - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 31
. screws in the middle hole on each rail flange (Figure 15). 1 1 1. Screws, panhead, 10-32 x 3/8 in. Figure 15 Rear view . 26588b MPX200 Multifunction Router User Guide 31 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 32
5. Route the power cord: a. Starting from the front of the rack, connect the power cord to the MPX200. b. For the left blade, route the cord by following the gap between the chassis and the chassis rail (see Figure 16). c. Repeat for the right blade. NOTE: The right blade requires the power cord to - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 33
HP StorageWorks MPX200 bezel: a. Remove the four 10-32 x 3/8 in. screws that secure the rack rails to the front of the rack. b. Position the bezel support each side of the bezel support plate. d. Install the bezel by pushing it through the white pop-in tabs on the bezel support plate (Figure 17). 1. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 34
34 Installing the MPX200 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 35
instructions for setting up the MPX200 management port, Fibre Channel zoning, HP Command View EVA discovery, setting up the iSCSI IP ports, and setting the date and time. NOTE: FCIP functionality is not completely configured using HP Figure 18 on page 36). MPX200 Multifunction Router User Guide 35 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 36
single EVA or XP array. Place an array target port in the same zone as one of the VPG ports (see Figure 19 on page 37). This ensures a single path to the FC port on the router blade and gives you more control of load balancing through the router. 36 Managing the MPX200 using HP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 37
Figure 19 Fibre Channel zone configuration . HP Command View EVA discovery Once the management port IP address is set and the router FC ports are visible to the EVA, you can perform the button (see Figure 20). Figure 20 iSCSI devices folder properties . MPX200 Multifunction Router User Guide 37 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 38
NOTE: HP recommends that you set a static IP address on the management port to ensure connectivity. each blade. Figure 21 Host properties . In the IPv4 or IPv6 box, select Static and set the management port IP address. Figure 22 shows the Management Port tab on the iSCSI Controller Properties page. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 39
. Setting up the iSCSI IP ports Each iSCSI IP port must have an IP address-IPv4, IPv6, or both. Set the IP address on the IP Ports tab on the iSCSI Controller Properties page (see Figure 23). NOTE: A target portal is created for each IP address that you set. MPX200 Multifunction Router User Guide - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 40
on the MPX200 ensures the synchronization of events and assists in troubleshooting. You have three options for setting the date and time (see Figure 24). NOTE: HP recommends using the Network Time Protocol (NTP) settings, if available on your network. This provides redundancy through multiple time - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 41
Figure 24 Set iSCSI controller time . Code load NOTE: HP recommends that you load the latest MPX200 firmware. Check http://www.hp.com/go/mpx200 for updates. You load the firmware from the Code button. The MPX200 reboots upon successful load of the firmware. MPX200 Multifunction Router User Guide 41 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 42
Save function allows you to save the configuration to a file that can be used later as a restoration point. The FRU 42 Managing the MPX200 using HP Command View EVA - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 43
required. To save or restore the MPX200 configuration: 1. Select the desired blade. 2. Click the Set Options button. 3. Click the Save Configuration button. 4. Select the configuration method (see Figure 27). on. NOTE: The beacon turns off after 15 minutes. MPX200 Multifunction Router User Guide 43 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 44
controller Before you remove an iSCSI controller permanently, ensure that all virtual disk presentations have been removed. To remove an iSCSI controller: 1. Select the desired iSCSI controller. 2. Click the Set Options button. 3. Click the Remove controller button (see Figure 30). 4. Click the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 45
Figure 30 iSCSI controller options: Remove controller . MPX200 Multifunction Router User Guide 45 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 46
46 Managing the MPX200 using HP Command View EVA - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 47
for XP 24000/20000 Setting up the MPX200 management If the management port cannot obtain a DHCP address, you must set a static IP address. Static IP addresses are highly recommended admin start command to change settings (see Figure 32). Figure 32 The admin start command . MPX200 Multifunction - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 48
command to setup the management port IP address (see Figure 33). Figure 33 The set mgmt command. . Set up the iSCSI ports The iSCSI ports require an IP address. Use the set iscsi command (see Figure 34). Figure 34 The set iscsi command . Fibre Channel zoning See "Fibre Channel zoning" on page 35 and - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 49
Figure 35 The show vpgroup command . LUN management LUN masking for MPX200 connectivity to XP is accomplished by executing the following procedure. The MPX200 is treated as if it were a Windows FC host to the XP. MPX200 Multifunction Router User Guide 49 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 50
for installing MPIO using the Microsoft generic DSM (Microsoft MPIO Multipathing Support for iSCSI check box). For Windows Server 2008, MPIO is installed separately as a feature. 3. See "Setting up the iSCSI initiator" on page 60 to set up the Windows host and register the IQN name. 4. Install and - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 51
LUN Selection window . 6. Expand the desired ports and select the same LUN from each (see Figure 38). Figure 38 Expanded ports . MPX200 Multifunction Router User Guide 51 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 52
7. Select the initiator and finish (see Figure 39). Figure 39 Select the Initiators . 8. Follow the steps beginning with "Step 3" on page 65 to log in to the target. 52 Managing the MPX200 for XP 24000/20000 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 53
blades. Dual-blade configurations provide for high availability with failover between blades, and are supported as redundant pairs only. iSCSI-connected servers can be configured for access to one to the MPX200. Table 4 lists the supported maximums. MPX200 Multifunction Router User Guide 53 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 54
management functions are integrated in HP Command View EVA. IMPORTANT: The MPX200 requires a specific controlled release of HP Command View EVA. For more information and to receive the supported HP Command View EVA version, contact your HP service representative. 54 MPX200 iSCSI configuration - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 55
using a confined or secured IP network in the data center. EVA storage system software EVA storage system software supported for Fibre Channel hosts, such as HP StorageWorks Continuous Access, Business Copy, Storage System Scripting Utility (SSSU), and Replication Solutions Manager (RSM), are - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 56
StorageWorks Continuous Access EVA HP StorageWorks Continuous Access EVA with HPsupported FCIP gateways iSCSI and Fibre Channel hosts and LUN remote replication are supported. XP storage system rules and guidelines The MPX200 is supported with the following XP storage systems: • XP24000 • XP20000 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 57
XP24000/20000 operating system and multipath software support. Table 7 MPX200-XP operating system and multipath support Operating system Multipath software XP storage iSCSI ports can be in different IP subnets. This requires setting the MPX200 iSCSI gateway feature. For more information, see " - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 58
parameter is set automatically by the HP StorageWorks MPX200 for Enterprise Virtual Array Windows software kit, which is available at http://h18006.www1.hp.com/products/storageworks/evaiscsiconnect/index.html . CAUTION: Using the Registry Editor incorrectly can cause serious problems that may - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 59
access to the same LUN via VMFS • VMware ESX server 4.0/3.5 native multipath solution based on NIC teaming iSCSI initiator operating system considerations follow: • Host-mode setting-VMware • Hardware iSCSI initiator (iSCSI HBA)-Not supported MPX200 Multifunction Router User Guide 59 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 60
hp.com/storage/spock. You must sign up for an HP Passport to enable access. Table 8 lists the IP network adapters supported by the MPX200. Table 8 Supported IP network adapters IPv6 on the HP Command View management server. Setting up the iSCSI initiator This section explains how to set up the iSCSI - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 61
1. Install the HP StorageWorks MPX200 iSCSI kit. a. Start the installer by running Launch.exe. (If you are using a CD-ROM, the installer should start automatically.) b. Click Install iSCSI software package (Figure 40). Figure 40 Installing the Windows Server 2003 kit . For Windows Server 2003, the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 62
Figure 41 Installation Wizard . c. Click the Microsoft iSCSI Initiator icon to open the Control Panel applet. The iSCSI Initiator Properties window opens. d. Select the Discovery tab (Figure 42). Figure 42 iSCSI initiator properties: Discovery tab . e. In the Target Portals section, click Add. A - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 63
HP Command View EVA, set up the iSCSI host and virtual disks. a. Click the EVA Storage Systems icon to start the iSCSI storage presentation. In Figure 43, MPX200-XL is the target EVA storage system from the Operating System list. d. Create a virtual disk and present it to the host you created in Step - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 64
Figure 44 Virtual disk properties . Figure 45 Host details . 64 MPX200 iSCSI configuration rules and guidelines - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 65
to choose the Local Adapter, Source IP, and Target Portal. The Target Portal IP Address is the iSCSI port that this initiator connection is defined. e. Depending on the operating system, open Server Manager or Computer Management. f. Select Disk Management. MPX200 Multifunction Router User Guide 65 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 66
disk. Ideally, the paths would use separate network interface cards (NICs) and a separate network infrastructure (cables, switches, and MPX200 blades). HP . The iSCSI target must support multiple sessions to the same target. The Microsoft iSCSI MPIO DSM supports a set of load-balance policies that - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 67
Multipath I/O check box on the Select Features page (Figure 47). Figure 47 Select Features page . 2. Click Next, and then click Install. MPX200 Multifunction Router User Guide 67 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 68
for iSCSI devices using the MPIO applet (Figure 48 and Figure 49). NOTE: You must present a virtual disk to the initiator to enable the Add support for iSCSI devices check box (see Figure 48). Figure 48 MPIO Properties page before reboot . Figure 49 MPIO Properties page after reboot . 4. Reboot - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 69
Microsoft MPIO Multipathing Support for iSCSI check XP Professional does not support Microsoft MPIO. Microsoft Windows HP NC3xxx Multifunction Gigabit server adapters use SNP to support TCP off-load functionality. For support details, see the latest HP adapter information at http://h18004.www1.hp - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 70
Windows 2003 only. To set up SNP on a Windows 2003 server: 1. Following the manufacturer's installation instructions, install the hardware and software for the NC3xxx Multifunction Gigabit server adapter. 2. Download the SNP package from the Microsoft website: http://support.microsoft.com/kb/ 912222 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 71
(Figure 52). Figure 52 Add static IP address . c. Select a target from the Discovered Targets list and then click Add (Figure 53). MPX200 Multifunction Router User Guide 71 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 72
Figure 53 Discovered Targets list . NOTE: The mpx iSCSI port may present several iSCSI targets to the Xtend SAN iSCSI Initiator. Select only one target from the list. d. For ISNS discovery Select Initiator and then enter the iSNS name or IP address in the box (Figure 54). Figure 54 iSNS discovery - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 73
). i. Select the Auto Login check box to configure the initiator to automatically log in to the iSCSI target at system startup. MPX200 Multifunction Router User Guide 73 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 74
j. Click Save. Figure 56 Selecting the newly added target . k. Click Status, select the network node, and then click Login to connect to the MPX target (Figure 57). The target status is Connected and the target status light turns green. Figure 57 Select status . 74 MPX200 iSCSI configuration rules - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 75
Setting up storage for Apple Mac OS X 1. In HP Command View EVA, present the LUNs in again to the target, or reboot the system. 3. Set up the iSCSI drive on the Xtend SAN iSCSI Initiator: a. Open Disk Utilities from the Apple Mac OS X Finder Applications list. b. Multifunction Router User Guide 75 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 76
/.iscsi 2. To configure the initiator and targets, start the iSCSI initiator applet (located in the YaST Control Center under Network Services), and then set the initiator to start at boot time (Figure 59). Figure 59 Configure the iSCSI initiator and targets . 3. Select the Discovered - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 77
4. Log in to the target (Figure 61). Figure 61 Log in to the target . MPX200 Multifunction Router User Guide 77 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 78
iscsiadm command to control discovery and connectivity: # iscsiadm -m discovery -t st -p 10.6.0.33:3260 2. Edit the initiator name: # vi /etc/iscsi/initiatorname.iscsi 3. Start the iSCSI service: # service iscsi start 78 MPX200 iSCSI configuration rules and guidelines - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 79
service command: man iscsi.conf 2. Manually start iSCSI services to test your configuration: /etc text following the colon. If there is a problem starting the iscsi daemon, it is usually due from a previous version of an iSCSI driver, HP recommends that you remove the /etc/.iscsi - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 80
NOTE: The Linux driver supports both Red Hat 3 and SUSE 8. For information on how to logical unit. The symbolic links are named using the Linux devfs naming convention. • The symbolic link disk maps to the whole-disk SCSI device node (for example, /dev/sda or / dev/sdb). • The symbolic links, part1 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 81
sessions are unable to log in immediately due to network or authentication problems, the iscsi-mountall script may time out and fail to mount target configuration changes or network delays). Instead of directly mounting SCSI devices, HP recommends that you do one of the following: • Mount the /dev - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 82
buffered writes may not be committed to disk, and file system corruption may occur. storage for Linux To present EVA storage for Linux: 1. Set up the LUNs by using HP Command View EVA, as described in Step 2 on page 63. 2. Set up the iSCSI drive on the iSCSI initiator. a. Restart the iSCSI services - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 83
2. Configure the VMKernel TCP/IP networking stack for iSCSI support. Configure the VMkernel service console with dedicated virtual switch with a dedicated NIC for iSCSI data traffic. Follow the instructions from VMware. Figure 63 on page 83 shows an example of a configuration. Figure 63 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 84
3. Open a firewall port by enabling the iSCSI software client service: a. Using the VMware VI client, select the server. b. Click the Configuration tab, and then click Security Profile. c. Click the Properties link. The Firewall Properties dialog - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 85
b. Click the Configuration tab, and then click Storage Adapters under Hardware. c. Under iSCSI Software Adapter, choose the available software initiator. d. Click the Properties link of the software adapter. The iSCSI Initiator Properties dialog box is displayed. e. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 86
5. Set up Discovery Addressing for the software initiator: a. Repeat Step 4 to open the iSCSI initiator Properties dialog box. b. Click the Dynamic Discovery tab. c. Click Add to - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 87
and click the Configuration tab. b. Choose Storage Adapters in the hardware panel and click Rescan above the Storage Adapters panel. The Rescan dialog box is details on managing and troubleshooting Solaris iSCSI multipath devices, see the Solaris System Administration Guide: Devices and File Systems - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 88
set: # mpxio-disable="yes"; # mpxio-disable="no"; # Enabling MPxIO for an HP EVA storage array This section explains how to configure a Solaris server to recognize an HP storage array in an iSCSI multipath environment with the MPX200. Editing the scsi_vhci.conf file HP storage arrays are supported - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 89
• With no load balancing • With no failback To configure MPxIO for HP storage arrays, you must add information to the /kernel/drv/ scsi_vhci.conf file: 1. Use a text editor to : load-balance="none"; 3. Change auto-failback to disable: auto-failback="disable"; MPX200 Multifunction Router User Guide 89 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 90
the following lines for the EVA4x00/6x00/8x00 storage arrays: device-type-scsi-options-list = "HP HSV", "symmetric-option"; symmetric-option = 0x1000000; NOTE: You must enter six spaces between HP and HSV. Example: HP storage array settings in /kernel/drv/scsi_vhci.conf # # Copyright 2004 Sun - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 91
-config-list="array_ctrl"; 3. Uncomment all target/LUN pair entries. Example: HP storage array settings in /kernel/drv/sgen.conf . . . # devices on your class="scsi" target=15 lun=0; Creating an sgen driver alias The HP storage array is a self-identifying SCSI device and must be bound to the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 92
Lowercase c is mandatory. 2. Verify the sgen alias setting: #egrep sgen /etc/driver_aliases Example: # rep sgen /etc/driver_aliases sgen "scsa,08.bfcp" sgen "scsa,08.bvhci" sgen "scsiclass,0c" Enable iSCSI target discovery Solaris supports three iSCSI target discovery methods: • SendTargets • Static - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 93
0 ISID: 4000002a0000 Connections: 1 Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.50014380025c417d Alias: TPGT: 0 ISID: iscsi Modifying the target parameter MaxRecvDataSegLen Sun recommends that you set the MaxRecvDataSegLen parameter to 65,536 bytes for each iSCSI Router User Guide 93 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 94
setting: # iscsiadm list target-param Target: iqn.1986-03.com.hp:fcgw.mpx200.0834e00028.b1.01.50014380025c417d #iscsiadm modify target-param -p maxrecvdataseglen=65536 iqn.1986-03.com.hp Monitoring the multipath devices After HP Command View EVA has presented the virtual disks to the Solaris host, - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 95
hp:fcgw.mpx200.0834e00028.b2.01.50014380025c4179 Alias: TPGT: 0 ISID: 4000002a0000 Connections: 1 LUN: 120 Vendor: HP Product: HSV300 OS Device Name: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2 Target: iqn.1986-03.com.hp 120 Vendor: HP Product: HSV300 /scsi_vhci/array-controller@ - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 96
unit. Use this command to verify symmetric mode, load balancing, and auto-failback settings, as well as path and target port information. Example: #mpathadm show lu Unit: /dev/rdsk/c5t600508B4000B15A200005000038E0000d0s2 mpath-support: libmpscsi_vhci.so Vendor: HP Product: HSV300 Revision: 0005 Name - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 97
. NOTE: For raw disk access, the MPIO load-balancing policy must be Failover Only. For file system disk access, all MPIO load-balancing policies are supported. Failover policies are set on a LUN-by-LUN basis. MPIO does not support global failover settings. MPX200 Multifunction Router User Guide 97 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 98
services and Microsoft MPIO. Because the iSCSI driver resides on the QLogic iSCSI HBA, it is not necessary to install the Microsoft iSCSI initiator. Installing the QLogic iSCSI HBA Install the QLogic iSCSI HBA hardware and software following the instructions in the QLogic installation manual - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 99
Configuring the QLogic iSCSI HBA To configure the QLogic iSCSI HBA: 1. Launch the QLogic SMS from the desktop icon or through Start > Programs, and connect to the local host (Figure 70). MPX200 Multifunction Router User Guide 99 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 100
port to configure the QLogic iSCSI HBA. • Configure the HBA Port network settings. • Configure the HBA Port DNS settings (optional). • Configure the SLP Target Discovery settings (optional). • Configure the iSNS Target Discovery settings (optional). Figure 70 Connect to Host window . Figure 71 Start - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 101
. 3. Repeat steps 1 and 2 for each MPX200 you want to add. 4. Click Next. 5. To activate the changes, enter the SMS password: config. 6. Select the Target Settings tab. Verify that the HBA state is Ready, Link Up and that each target entry state is Session Active (Figure 73). Figure 73 Target - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 102
Use the Microsoft iSCSI initiator services to manage the iSCSI target login and LUN load-balancing policies. Installing the HP MPIO Full Featured DSM for EVA Follow the procedure in the Installation and Reference Guide, available at http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 103
Cluster Server for Windows 2003 iSCSI Failover clustering is supported on the HP StorageWorks MPX200 Multifunction Router. For more information, see http://www.microsoft.com/windowsserver2003/technologies/storage/iscsi/ iscsicluster.mspx. Requirements • Operating system: Windows Server 2003 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 104
setting of AABBCCCCBBAA. Table 11 shows possible node settings. Table 11 Node settings Column Head Column Head Node 1 1 Node 2 2 Node 3 3 Node 4 4 When the HP for Windows 2008 iSCSI Failover clustering is supported on the HP StorageWorks MPX200 Multifunction Router. For more information, - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 105
private • two storage, for higher availability and performance • MPIO - use HP DSM or the Microsoft Generic DSM • HP recommends using secret. NOTE: Setting up authentication for your iSCSI devices is optional. If you require authentication, HP recommends that you Multifunction Router User Guide 105 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 106
to which it has access. • Normal-A normal session is unrestricted. CHAP is enforced on both discovery and normal sessions. MPX200 CHAP modes The MPX200 supports two CHAP modes. Once CHAP is enabled, it is enforced for both discovery sessions and normal sessions. You can choose only the CHAP mode - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 107
when you execute the set chap command, do one of the following: • From HP Command View EVA, select manually: a. Click Add under Target Portals. b. Enter the IP address of the MPX200 iSCSI port. c. Click Advanced. d. Select the CHAP Login Information check box. MPX200 Multifunction Router User Guide - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 108
to enable CHAP for the MPX200-discovered iSCSI initiator entry: • If the iSCSI initiator is not listed when you execute the set chap command, do one of the follow- ing: • From HP Command View EVA, select Hosts, and then select the Add Host tab. Enter the IQN string. • From the CLI, use - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 109
1. Click Discovery. To manually discover iSCSI target portals: a. Click Add under auth.password = CHAPSecret01 c. Set up the user name and password for the initiator for a discovery session. For example: # To set a discovery session CHAP = CHAPSecret01 MPX200 Multifunction Router User Guide 109 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 110
: [root@sanergy33 iscsi]# iscsiadm --mode node --targetname iqn.1986-03.com.hp:fcgw.mpx200.0840e00002. b1.01.50001fe15006ac39 --login The following is a sample iscsid.conf file for CHAP: CHAP Settings # To enable CHAP authentication set node.session.auth.authmethod # to CHAP. The default is None - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 111
settings MPX200 secret settings Source Setting (example) Microsoft initiator secret settings Action Setting settings. Configure CHAP using settings under the set chap command, do one of the following: • From HP Command View EVA presented target: a. Enter the set chap command. b. Select the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 112
secret (for example: hpstorageworks). e. Click Discovery. • To discover iSCSI target portals manually: a. Click Add under Target Portals. b. Enter the IP address of the iSCSI -direction CHAP during normal session Table 14 lists the settings you use to enable bidirectional CHAP during a discovery - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 113
of secret settings. Configure CHAP using settings that apply not listed when you execute the set chap command, do one of the following: • From HP Command View EVA, select Hosts the MPX200 iSCSI port using the MPX200 CLI: • Enter the set chap command. • Select the appropriate Portal iqn name index that - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 114
Reset. d. Enter the MPX200 iSCSI Presented Target CHAP secret (for example: hpstorageworks). e. Click OK. f. Click Discovery. • To discover iSCSI target portals manually: a. Click Add under Target Portals. b. Enter the IP address of the iSCSI port of the MPX200. c. Click Advanced. d. Select the CHAP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 115
settings MPX200 secret settings Source Setting (example) Microsoft initiator secret settings Action Setting settings. Configure CHAP using settings execute the set chap command, do one of the following: • From HP Command the MPX200 CLI: • Enter the set chap command. • Select the appropriate - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 116
MPX200 iSCSI presented target using the CLI: a. Enter the set CHAP command. b. Select the Presented Target the initiator logs secret (for example: hpstorageworks). e. Click OK. f. Click Discovery. • For manually discovering iSCSI target portals: a. Click Add under Target Portals. b. Enter the IP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 117
description The HP StorageWorks MPX200 Multifunction Router with an FCIP license provides FC SAN extension over an IP network. Used in conjunction with the EVA and XP storage system families and the HP Continuous Access software, the MPX200 enables long-distance remote replication for disaster - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 118
Router 1-GbE Base Chassis with an HP StorageWorks MPX200 Router 1-GbE Upgrade Blade, or an HP StorageWorks MPX200 Multifunction Router 10-1 GbE Base Chassis with an HP StorageWorks MPX200 Router 10-1 GbE Upgrade Blade. Note that FCIP is currently supported only on MPX200 1 GbE ports. See - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 119
to iSCSI is the loss of one 1 GbE port. Figure 79 FCIP impact on existing iSCSI configurations - single fabric per blade . MPX200 Multifunction Router User Guide 119 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 120
for that situation. MPX200 iSCSI/FCIP configurations The MPX200 router supports the following configurations: • Figure 81 MPX200 basic FCIP configuration with -redundant long-distance links • Figure 86 MPX200 configuration with remote IP distance gateway (mpx110) • Figure 87 MPX200 highly- - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 121
HP StoragMePWXo2r0k0s MGMT IOIOI GE4 GE3 FC1 MPX200 Multifun1cGtiobnERBoluatdeer FC2 GE1 GE2 MPX200 E Fabric B2 Remote FC servers Local storage system Remote storage and remote fabrics, allowing device access without merging the fabrics. This can be implemented in all supported MPX200 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 122
Figure 83 MPX200 FCIP with C-series IVR . Figure 84 MPX200 high-availability configuration with one or two long-distance links . Figure 85 MPX200 high-availability configuration with fully-redundant long-distance links . 122 MPX200 FCIP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 123
Figure 86 MPX200 configuration with remote IP Distance gateway (mpx110) . Figure 87 MPX200 highly-redundant configuration with one or two long-distance lists . Figure 88 MPX200 highly redundant pairs of gateways with fully-redundant long-distance links . MPX200 Multifunction Router User Guide 123 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 124
Figure 89 MPX200 simultaneous iSCSI and FCIP with remote dedicated FCIP blade . Figure 90 MPX200 simultaneous iSCSI and FCIP, both local and remote . 124 MPX200 FCIP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 125
in/fan-out relationships): • For Site 1, Site 2 or Site 3 can function as the remote site. • For Site 2 or Site 3, Site 1 can function as the remote site. • Replication between Site 2 and Site 3 is not supported. The following configuration rules apply to Figure 95 (peer-to-peer relationship): • For - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 126
3-site configuration with four MPX200 routers The configuration in Figure 92 provides long-distance link redundancy between all three sites. Figure 92 HP Continuous Access EVA 3-site configuration with four MPX200 routers . 3-site configuration with six MPX200 routers The configuration in Figure 93 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 127
Figure 93 HP Continuous Access EVA 3-site configuration with six MPX200 routers . 3-site configuration with eight MPX200 routers The configuration in Figure 94 3-site redundancy, with a dedicated MPX200 pair for all long-distance links to all three sites. MPX200 Multifunction Router User Guide 127 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 128
Figure 94 HP Continuous Access EVA 3-site configuration with eight MPX200 routers . 3-site configuration with six MPX200 routers and full inter-site connectivity Figure 95 provides long-distance link redundancy and full connectivity between all three sites. 128 MPX200 FCIP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 129
local and one remote, connected through an IP network. HP does not support FCIP connectivity between other gateway models. • FCIP is supported on GbE ports only (GE1, GE2). • The MPX200 Multifunction Router is supported for FCIP extension with HP Continuous Access EVA (see Storage system rules and - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 130
using FCIP with all operating systems and multipath software supported by HP for Continuous Access EVA and XP Continuous Access. For more information, see the HP StorageWorks SAN Design Reference Guide, available at http://www.hp.com/go/ SDGManuals. Storage system rules and guidelines • The MPX200 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 131
bandwidth (see Table 17). • For MPX200 IP management-LAN and WAN are supported. • For XP Continuous Access network requirements, see the SAN Extension chapter in the nl HP StorageWorks SAN Design Reference Guide. Table 17 Network requirements for the MPX200 with XCS and VCS Specification Bandwidth1 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 132
two routes, based on the 30 Mb/s total bandwidth available for FCIP, you would set the MPX200 bandwidth parameter to 15, the available bandwidth for each FCIP route. HP StorageWorks Continuous Access EVA replication solution requires dedicated bandwidth for the intersite link. If other applications - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 133
frames are not supported for use with HP Continuous Access EVA. Compression The MPX200 integrates a software compression option. This option can be set to disable, enable, or auto. When set to auto, the . See Modifying the window size and scaling factor. MPX200 Multifunction Router User Guide 133 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 134
window size and scaling factor in the MPX200 Multifunction Router pairs based on the WAN RTT and link speed. To determine the appropriate window size setting and scaling factor, use the pre-populated tables or the following formula. If the recommended TCP window size and scale factor for a given RTT - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 135
50 25 20 15 10 Window size (bytes) 2M 512K 256K 128K 128K 128K 64K 0 0 0 0 0 0 0 0 0 Scaling factor (2n) 5 4 3 2 2 2 1 0 0 0 Scaling factor (2n) 6 4 3 2 2 2 1 MPX200 Multifunction Router User Guide 135 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 136
5 32K 2.5 32K 1 or less 32K Table 22 OC-3 150 Mb/Sec (Bandwidth = 148 Mb) Round trip time (RTT) in ms 250 100 50 25 20 15 10 5 2.5 1 or less Window size (bytes) 16M 4M 2M 1M 1M 1M 512K 256K 128K 64K Table 23 DS-5 400 Mb/Sec (Bandwidth = 384 Mb) Round trip time (RTT) in ms 250 100 50 25 20 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 137
local site and the remote site (see Figure 77 on page 117): • HP StorageWorks MPX200 Multifunction Router 1-GbE Base Chassis or HP StorageWorks MPX200 Multifunction Router 10-1 GbE Base Chassis. Note that FCIP is currently supported only on MPX200 1 GbE ports. • HP Storage Works MPX200 Half Chassis - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 138
and FC cable, two per site • MPX200 serial console cable adapter, Cat 5e network cable Additional equipment for the local site and remote site (see Figure 84 on page 122 and Figure 86, page 123) is as follows: • HP StorageWorks MPX200 Multifunction Router 1-GbE Upgrade Blade (MPX200 blade for - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 139
set management port or serial console port to a workstation to set the initial MPX200 you are using the MPX200 serial port, the settings are 115,200 baud, 8 bit, 1 stop password at the Password prompt. NOTE: HP recommends that you change the MPX200 guest HP recommends that you change - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 140
initial parameters. Follow the on-screen prompts to configure the management port (or press Enter to accept the default settings, as shown in Figure 96): Figure 96 Setting IP addresses . The management port is now configured with the appropriate IP address and network parameters. IMPORTANT: If you - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 141
setting documented in this guide for the actual bandwidth and RTT of the link. • For recommendations on setting compression see IP performance tuning, page 131. NOTE: HP recommends that you accept the default settings Local) Subnet Mask Gateway IP Address Remote IP Address MTU Size (0=Normal, 1= - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 142
port], 1 (Must be set for all MPX200 FCIP FC ports regardless of storage types) • B-Switch# portcfggport [slot/ port] ,1 (set for all MPX200 FCIP based routing, set the Continuous Access EVA data replication protocol to HP FC Data Replication Protocol. • For exchange-based routing, use HP SCSI FC - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 143
links and firmware version 1. To determine whether a firmware upgrade is necessary, go to the SPOCK website at http:// www.hp.com/storage/spock. You must sign up for an HP Passport to enable access. Upgrade accordingly. 2. Use the CLI ping command to verify FCIP link connectivity. 3. Verify that the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 144
144 MPX200 FCIP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 145
Multifunction Router provides FCoE target functionality. Used with the HP StorageWorks arrays, the MPX200 enables FCoE connectivity over a 10-GbE link at no additional cost. FCoE features include: • 10-GbE model only • Support enabled with firmware version 3.2.2.0 (minimum) by default, no license - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 146
section "FCoE configurations" on page 145. 2. Set up the Converged Network Adapter (CNA). For more information regarding CNA configuration, see the Converged Network Adapter Installation Guide at: http://bizsupport1.austin.hp.com/bc/docs/support/SupportManual/c02018539/ c02018539.pdf a. Install the - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 147
host CNA. If multiple fabrics exist, create zones where redundancy requires it. There are two ways to identify the FCoE ports on the MPX200: • In HP Command View EVA, see the FC Ports tab of the iSCSI Controller 0X in the Hardware folder (see Figure 100): Figure 100 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 148
Figure 101 FCoE show fc command . 148 MPX200 FCoE feature description - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 149
belongs to the host. e. Select the appropriate operating system. f. Click the Add host button (see Figure 102). Figure 102 Host type . MPX200 Multifunction Router User Guide 149 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 150
5. Create a virtual disk and assign it to the FCoE host. Note that the host has its own icon. Each host entry has only one WWPN associated with it, so any host with multiple port CNAs must have an entry for each (see Figure 103). Figure 103 Host properties . 150 MPX200 FCoE feature description - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 151
6. Add FCoE targets to the FCoE zone. After the first virtual disk/LUN is presented, the FCoE targets are dynamically created and mapped. In Figure 104, if you mouse over /LUN assignments for the same or additional hosts. Figure 104 Host Details display . MPX200 Multifunction Router User Guide 151 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 152
152 MPX200 FCoE feature description - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 153
troubleshoot problems. Diagnostic information is also available through diagnostics, HP Command View EVA, and the CLI event logs and error messages. MPX200 chassis diagnostics Chassis diagnostics are indicated by the chassis LEDs (see Figure 105). NOTE: The USB port is unmarked and is not supported - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 154
voltage? • If yes, proceed to the next step. • If not, make the necessary repairs. If the problem persists, proceed to the next step. 3. Replace the MPX200 blade. System Fault LED is illuminated The System Fault that the MPX200 is operating normally (Figure 106). 154 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 155
LED indicates that the MPX200 blade beacon is ON. There are two ways to identify the location of an MPX200 blade: MPX200 Multifunction Router User Guide 155 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 156
button. Use the Locate ON and Locate OFF buttons to control the blue LED (Figure 111). Figure 111 Using HP Command View EVA to locate a hardware device . MPX200 log data The MPX200 maintains a log that can be view statistics, use the CLI command show stats. 156 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 157
ping command is the most basic network troubleshooting tool that is available to troubleshoot FCIP route problems. This command runs a diagnostic in command. Figure 112 FCIP route ping command . Troubleshooting using HP Command View EVA You can use HP Command View EVA to display the properties for - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 158
2: In HP Command View EVA, for each controller, click the IP ports tab, and then expand TCP properties under Advanced Settings. There should be connections available; if not, choose another IP port to log in to or log out from any unused connections (Figure 114). 158 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 159
the target to which the EVA LUN was assigned. Solution 2: The EVA LUN was assigned to a different iSCSI host than was expected. EVA-presented virtual disk not seen by initiator Solution: The initiator must log in to the appropriate iSCSI target. Match the virtual - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 160
Figure 115 Virtual disk properties: Host details . Figure 116 iSCSI initiator properties: Targets tab . Windows initiators may display Reconnecting if NIC MTU changes after in Solution. Log out of the sessions and log in again to re-establish the Connected state. 160 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 161
HP Command View EVA and the MPX200 is down, use the following options: • Option 1: Refresh using the iSCSI Controller button. • Option 2: • If the Ipv4 management port IP address is set IP address is set, enter a HP Command View EVA management server. HP supported Virtual disk operation supported - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 162
process may have been interrupted; try again. Invalid iSCSI controller code load file extension. Ensure that the correct file is being used. 162 Diagnostics and troubleshooting - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 163
Virtual Array user guide for your array • HP StorageWorks SAN Design Reference Guide You can also find the documents referenced in this guide on the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals For EVA documents, go to Storage and select Disk Storage - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 164
www.hp.com/go/storage • HP Partner Locator: http://www.hp.com/service_locator • HP Software Downloads: http://www.hp.com/support/downloads • HP Software Depot: http://h20293.www2.hp.com • HP Single Point of Connectivity Knowledge (SPOCK) http://www.software.hp.com • HP StorageWorks SAN manuals: http - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 165
conventions Convention Blue text: Table 26 Blue, underlined text: http://www.hp.com Bold text Italic text Monospace text Monospace, italic text Monospace, bold : Provides clarifying information or specific instructions. NOTE: Provides additional information. MPX200 Multifunction Router User - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 166
. • Extend only one rack component at a time. Racks can become unstable if more than one component is extended. Product warranties For information about HP StorageWorks product warranties, see the warranty information website: http://www.hp.com/go/storagewarranty 166 Support and other resources - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 167
command line. Moves the cursor to the end of the command line. Authority requirements You must be in an administrator (Admin) session to perform various set commands. Note that: • Commands for monitoring tasks are available to all accounts. MPX200 Multifunction Router User - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 168
• Commands for configuration tasks are available only in an Admin session. An account must have admin authority to execute the admin start command, which opens an Admin session (see admin command). Commands This section lists and describes the MPX200 CLI commands in alphabetical order. Admin Opens - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 169
. stats Resets the statistics counters. Examples: The following examples show the clear commands: MPX200 (admin) #> clear logs MPX200 (admin) #> clear stats MPX200 Multifunction Router User Guide 169 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 170
the command displays the current date, which does not require an Admin session. NOTE: Always set the time using Greenwich Mean Time (GMT) and Universal Transverse Mercator (UTM). You must for the blade: MPX200 (admin) #> exit HP StorageWorks MPX200 #> 170 Command referencecommand reference - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 171
Port (1=FC1 ) GE Port (1=GE1 ) IP Address (IPv4 or IPv6; 0=IPv6 Link Local) Subnet Mask Gateway IP Address Remote IP Address MTU Size (0=Normal, 1=Jumbo, 2=Other) TCP Window Size (0=8KB, 1=16KB, 2=32KB) Window Scaling (0=Enable and the ENTER key to do so. MPX200 Multifunction Router User Guide 171 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 172
FCIP Route FCIP Interfaces FC & GE (0=Enable, 1=Disable) IP Address (IPv4 or IPv6; 0=IPv6 Link Local) Subnet Mask Gateway IP Address Remote IP Address MTU Size (0=Normal, 1=Jumbo, 2=Other) TCP Window Size (0=8KB, 1=16KB, 2=32KB) Window Scaling (0=Enable, 1=Disable) Window Scaling Factor (Min - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 173
. The following example shows the help command for the chassis: MPX200 #> help admin [begin | end | start | stop | cancel] blade [1 | 2] exit help MPX200 Multifunction Router User Guide 173 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 174
| isns | mgmt | ntp | properties | snmp | system | vpgroups] set alias set chap set chassis set fc [] set features set iscsi [] set isns set mgmt set ntp set properties set snmp [trap_destinations []] set system set vpgroups [vpgroup index] show [chap | chassis | fc - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 175
transfer the firmware image file to the router's /var/ftp directory. To activate the new firmware, you must reboot the router. MPX200 Multifunction Router User Guide 175 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 176
Authority Syntax Keywords Admin session add initiat- mod or remove add Adds an initiator to the router's database. mod Modifies the settings of an initiator. remove Removes a logged-out initiator. You cannot remove an initiator that is currently logged in. Example 1: MPX200 (admin - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 177
): 0 Index (WWNN,WWPN/iSCSI Name 0 20:00:00:20:37:fd:8b:ab,22:00:00:20:37:fd:8b:ab MPX200 Multifunction Router User Guide 177 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 178
1 20:00:00:20:37:fd:8a:b0,22:00:00:20:37:fd:8a:b0 2 20:00:00:20:37:fd:9c:f7,22:00:00:20:37:fd:9c:f7 3 20:00:00:20:37:fd:8d:00,22:00:00:20:37:fd:8d:00 Please select a Target from the list above ('q' to quit): 0 LUN WWULN Vendor 0 20:00:00:20:37:fd:8b:ab:00:00:00:00:fc:b7:3f:fa SEAGATE Please select - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 179
IPv6. Authority Syntax Admin session ping Example: MPX200 (admin) #> ping A list of attributes with formatting and current values will follow. Enter a MPX200 Multifunction Router User Guide 179 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 180
level, quit returns you to the chassis management level. The following example shows the quit command for the blade: MPX200 (admin) #> quit HP StorageWorks MPX200 #> Reboot Restarts the blade firmware. Authority Syntax Example: Admin session reboot 180 Command referencecommand reference - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 181
command deletes all LUN mappings, as well as all persistent data for targets, LUNs, initiators, VPG settings, log files, iSCSI and management IP addresses, FC and Ethernet port statistics, and passwords. This FTP the debug capture file from the blade. MPX200 Multifunction Router User Guide 181 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 182
. Configures general router parameters, as well as parameters for the FC, iSCSI, and management ports. Authority Admin session Syntax set Keywords alias chap alias chap chassis fc [] features iscsi [] isns mgmt ntp properties snmp [trap_destinations []] system - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 183
" on page 186. Sets the iSCSI port parameters. See "set iSCSI command" on page 186. Sets the Internet Simple Name Service (iSNS) parameters. See "set iSNS command" on page 186. Sets the management port parameters. See "set mgmt command" on page 187. Sets the NTP parameters. See "set NTP command" on - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 184
. Set CHAP Configures the CHAP parameters. Authority Syntax Admin session set chap Example: MPX200 (admin) #> set chap hp:fcgw.mpx200.0834e00025.b1.0 1 iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.1 2 iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.01.50001fe150070ce9 3 iqn.1986-03.com.hp - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 185
rack 14 All attribute values that have been changed will now be saved. Set FC Configures an FC port. Authority Syntax Keywords Admin session set fc [] [] The number of the FC port to be 2 that have been changed will now be saved. MPX200 Multifunction Router User Guide 185 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 186
set on the router before applying a new key. Authority Syntax Admin session set features Set iSCSI Configures an iSCSI port. Authority Syntax Keywords Admin session set iSCSI port to be configured. Example: MPX200 (admin) #> set iscsi 1 A list of attributes with formatting and current values - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 187
[Manual ] 1 All attribute values that have been changed will now be saved. Example 2: The following example shows how to use the set mgmt command to set a static address: MPX200 (admin) #> set attribute values that have been changed will now be saved. MPX200 Multifunction Router User Guide 187 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 188
to do so. CLI Inactivity Timer (0=Disable, 1=15min, 2=60min) [15min ] CLI Prompt (Max=32 Characters) [HP StorageWorks MPX200 ] All attribute values that have been changed will now be saved. Set SNMP Configures general SNMP) properties and eight trap destinations. Authority Syntax Admin session - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 189
(admin) #> set snmp A list The following example shows the set snmp command for configuring an SNMP trap destination: MPX200 (admin) #> set snmp trap_destinations A list of values that have been changed will now be saved. Set system Configures the blade's system-wide parameters. Authority - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 190
WAN, 3=Data Migration) [iSCSI Connectivity] Target Presentation Mode (0=Auto, 1=Manual) [Auto ] Lun Mapping (0=Enable, 1=Disable) [Disabled ] Controller ] All attribute values that have been changed will now be saved. Set VPGroups Sets VPGs on the blade. Allows you to enable or disable VPGs, and - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 191
on page 193. Displays FC port information. See "show FC command" on page 194. Displays the current settings for a particular FCIP route or for all FCIP routes. See "show fciproutes command" on page 194. Displays initiators LUN mask command" on page 196. MPX200 Multifunction Router User Guide 191 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 192
iscsi [port_num] Displays iSCSI port and configuration information. See "show iSCSI command" on page 196. isns [port_num] Displays the router's iSCSI name server (iSNS) configuration. See "show iSNS command" on page 197. logs [last_x_entries] Displays the router's logging information. See "show - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 193
/36C/37C/41C Power Cooling Module 1 Status Installed Power Source Connected Fan1/Fan2/Fan3 Healthy/Healthy/Healthy Blade 2 Information (Right Slot Status Online Product Name HP StorageWorks MPX200 Symbolic Name Blade-2 Serial Number 0836E00018 MPX200 Multifunction Router User Guide 193 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 194
03.07 Frame Size 2048 Execution Throttle 64 Connection Mode Loop Programmed Connection Option Loop Preferred Show fciproutes Displays the current settings for a particular FCIP route or for all FCIP routes. Authority Syntax Keywords None show fciproutes [link_id] [link_id] Route number to display - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 195
FCIP Link Status FC Port GE Port GE Link Status Local IP Address Remote IP Address Subnet Mask Gateway IP Address MTU Size TCP Window Size Window Scaling Window Initiator Information Initiator Name iqn.1991-05.com.microsoft:server1 Alias IP Address 0.0.0.0 MPX200 Multifunction Router User Guide 195 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 196
: MPX200 (admin) #> show iscsi iSCSI Port Information iSCSI Port GE1 Port Status Enabled Link Status Up iSCSI Name iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.0 Firmware Revision 3.00.01.57 Current Port Speed 1Gb/FDX Programmed Port Speed Auto MTU Size Jumbo 196 Command - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 197
entire router event log. Example: MPX200 #> show logs 01/01/2008 00:00:13 System 3 Tuesday 01 January 12:13 AM MPX200 Multifunction Router User Guide 197 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 198
select a LUN from the list above ('q' to quit): 1 LUN Information WWULN 50:00:1f:e1:50:07:0c:e0 LUN Number 0 VendorId HP ProductId HSV210 ProdRevLevel 5000 Portal 1 Lun Size 0 MB Lun State Online Show LUNs Displays LUN information for each target. Authority Syntax None show - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 199
GE port connections. It does not display information about free space in the /var/ftp/directory. Authority Syntax None show memory MPX200 Multifunction Router User Guide 199 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 200
Example: MPX200 #> show memory Memory Units Free/Total Physical 415MB/1002MB Buffer Pool 6866/8960 Nic Buffer Pool 0/0 Process Blocks 8192/8192 Request Blocks 8192/8192 Event Blocks 2048/2048 Control Blocks 2048/2048 Sessions 2048/2048 Connections: GE1 256/256 GE2 256/256 GE3 256/256 GE4 256/256 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 201
configured FCIP routes. Displaying bytes/sec (initiator mode read)... (Press any key to stop display) GE1 GE2 GE3 GE4 FC1 FC2 MPX200 Multifunction Router User Guide 201 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 202
presented_targets iscsi Presented Target Information iSCSI Presented Targets Name iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.01.50001fe150070ce9 Alias WWNN 50:00: 50:00:1f:e1:50:07:0c:e9 Name iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.02.50001fe150070ce9 Alias WWNN 50:00: - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 203
:00:1f:e1:50:07:0c:e0 WWPN 50:00:1f:e1:50:07:0c:e9 Name iqn.1986-03.com.hp:fcgw.mpx200.0834e00025.b1.04.50001fe150070ce9 Alias WWNN 50:00:1f:e1:50:07:0c:e0 WWPN 50: 's SNMP configuration and any configured traps. Authority Syntax None show snmp MPX200 Multifunction Router User Guide 203 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 204
Read Community Public Trap Community Private System Location System Contact Authentication traps Disabled System OID 1.3.6.1.4.1.3873.1.5 System Description HP StorageWorks MPX200 Trap Destination 1 IP Address 10.0.0.5 Trap Port 1024 Trap Version 2 Show stats Displays the blade statistics for - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 205
Xmited 55036896842234 PDUs Rcvd 2655246170 Data Bytes Rcvd 0 I/O Completed 1815115669 Unexpected I/O Rcvd 0 iSCSI Format Errors 0 Header Digest Errors 0 Data Digest Errors 0 MPX200 Multifunction Router User Guide 205 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 206
Version SW Version Boot Loader Version No. of FC Ports No. of iSCSI Ports Telnet SSH Temp (Front/Rear/CPU1/CPU2) HP StorageWorks MPX200 Blade-1 iSCSI Server Connectivity Enabled Disabled 0851E0014 20694-03 3.0.1.2 0.97.0.4 2 2 Enabled Enabled 42C/31C/34C/34C 206 Command referencecommand reference - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 207
:44 21:01:00:c0:dd:13:16:45 Example 2: The following example shows the show vpgroups command for all VPGs: MPX200 Multifunction Router User Guide 207 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 208
MPX200 #> show vpgroups VpGroup Information Index 1 VpGroup Name VPGROUP_1 Status Enabled WWPNs 21:00:00:c0:dd:13:16:44 21:00:00:c0:dd:13:16:45 Index VpGroup Name Status WWPNs 2 VPGROUP_2 Enabled 21:01:00:c0:dd:13:16:44 21:01:00:c0:dd:13:16:45 Index VpGroup Name Status WWPNs 3 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 209
.35.9.1 459.1ms 465.6ms 480.0ms 7 172.35.14.17 495.3ms 483.0ms 505.9ms Traceroute completed in 7 hops. MPX200 Multifunction Router User Guide 209 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 210
210 Command referencecommand reference - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 211
in. 3. Enter an account name and password. To log on to a switch through the serial port: 1. Configure the workstation port with the following settings: • 115,200 baud • 8-bit character • 1 stop bit • No parity 2. When prompted, enter an account name and password. MPX200 Multifunction Router User - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 212
Name Router Chassis Name Serial Number 0834E00019 HW Version 20697-03 A Fan Speed Normal Blade 1 Information (Left Slot Status Online Product Name HP StorageWorks MPX200 Symbolic Name Blade-1 Serial Number 0834E00008 HW Version 20694-03 A SW Version 3.0.1.0rc2a Temp (Front/Rear/CPU1/CPU2) 44C/33C - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 213
of configuration: • Management port configuration requires the use of the following commands: • The "set mgmt command" on page 187 • The "show mgmt command" on page 200 • iSCSI port Guest login ok, access restrictions apply. ftp> bin 200 Type set to I. MPX200 Multifunction Router User Guide 213 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 214
on a new blade any time it is detected in the chassis. 200 Type set to I. ftp> put HP StorageWorks MPX200_FRU.bin 200 PORT command successful. 150 Opening BINARY mode data connection for 'HP StorageWorks MPX200_FRU.bin'. 226 Transfer complete. ftp: 6168 bytes sent in 0.00Seconds 6168000.00Kbytes - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 215
supports SNMP versions 1 and 2 and a QLogic Management Information Base (MIB) (see "Management Information Base " on page 216). You may format traps using SNMP version 1 or 2. SNMP parameters You can set authentication failures. The default is disabled. MPX200 Multifunction Router User Guide 215 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 216
trap configuration parameters SNMP trap configuration lets you set up to eight trap destinations. Choose from Trap IP address to which the SNMP traps are sent. A maximum of eight trap addresses are supported. The default address for traps is 0.0.0.0. Trap port1 Port number on which the trap is - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 217
4 = RARP Read-only Method by which the port gets its IP address. InetAddressType Read-only IP address type: ipv4 or ipv6. MPX200 Multifunction Router User Guide 217 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 218
Syntax Access Description qsrNetMask Syntax Access Description qsrGateway Syntax Access Description qsrMacAddress Syntax Access Description qstNwLinkStatus Syntax Access Description qsrNwLinkRate Syntax Access Description InetAddress Read-only IP address of the port. InetAddress Read-only Subnet - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 219
port in a given role. qsrFcPortNodeWwn Syntax Access Description PhysAddress Read-only World Wide Name of the node that contains this port. MPX200 Multifunction Router User Guide 219 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 220
qsrFcPortWwn Syntax Access Description qsrFcPortId Syntax Access Description qsrFcPortType Syntax Access Description qsrFcLinkStatus Syntax Access Description qsrFcLinkRate Syntax Access Description PhysAddress Read-only World Wide Name for this port. PhysAddress Read-only Interface's 24-bit FC - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 221
of the initiator. qsrIsInitAlias Syntax Access Description SnmpAdminString Read-only Alias for the iSCSI initiator. qsrIsInitAddressType Syntax Access InetAddressType Read-only MPX200 Multifunction Router User Guide 221 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 222
Description qsrIsInitAddress Syntax Access Description qsrIsInitStatus Syntax Access Description qsrIsInitOsType Syntax Access Description qsrIsInitChapEnabled Syntax Access Description Type of iSCSI initiator's IP address (IPv4 or IPv6). InetAddress Read-only IP address of the iSCSI initiator. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 223
-only Vendor ID for the LUN. qsrLunProductId Syntax Access Description SnmpAdminString Read-only Product ID for the LUN qsrLunProdRevLevel Syntax SnmpAdminString MPX200 Multifunction Router User Guide 223 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 224
Access Description qsrLunSize Syntax Access Description qsrLunState Syntax Access Description qsrLunVPGroupid Syntax Access Description qsrLunVPGroupname Syntax Access Description Read-only Product revision level for the LUN Unsigned32 Read-only Size of the LUN (in megabytes) Integer 1 = online, 2 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 225
SnmpAdminString Read-only VP group name or host group name. qsrVPGroupWWNN Syntax Access Description VpGroupWwnnAndWwpn Read-only Worldwide port number (WWPN) MPX200 Multifunction Router User Guide 225 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 226
qsrVPGroupStatus Syntax Access Description Integer: 0 = enabled; 1 = disabled Read-only Maintain the status of the VP group (enabled/disabled) 226 Simple Network Management Protocol setup - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 227
data being measured by this sensor. qsrSensorIndex Syntax Access Description Unsigned32 Not accessible A positive integer identifying each sensor of a given type. MPX200 Multifunction Router User Guide 227 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 228
qsrSensorUnits Syntax Access Description qsrSensorValue Syntax Access Description qsrUpperThreshold Syntax Access Description qsrLowerThreshold Syntax Access Description qsrSensorState Syntax Access Description INTEGER Celsius = 1 Read-only Unit of measurement for the sensor. Integer32 Read-only - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 229
FC ports on the system. qsrNoOfGbEPorts Syntax Access Description Unsigned32 Read-only Quantity of gigabit Ethernet ports on the system. qsrAgentVersion MPX200 Multifunction Router User Guide 229 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 230
down notification indicates that the specified network port is down. The next time the port comes up, this event is sent with the qsrEventSeverity object set to clear. qsrNwPortDown uses the following objects: 230 Simple Network Management Protocol setup - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 231
next time the port comes up, this event is sent with the qsrEventSeverity object set to clear. qsrFcPortDown uses the following objects: • qsrFcLinkStatus • qsrEventTimeStamp • qsrEventSeverity objects: • qsrBladeSlot • qsrEventTimeStamp • qsrPresTgtMapped MPX200 Multifunction Router User Guide 231 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 232
is not normal. When the sensor returns to the normal state, this event is sent with the qsrEventSeverity object set to clear. qsrSensorNotification uses the following objects: • qsrSensorValue • qsrSensorState • qsrEventTimeStamp • qsrEventSeverity Sensor notifications are sent for the following - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 233
2) • Router configuration change • Blade number (1 or 2) • Management port configuration change • Blade number (1 or 2) • Firmware upgrade complete • Blade number (1 or 2) • Reboot blade MPX200 Multifunction Router User Guide 233 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 234
• Blade number (1 or 2) 234 Simple Network Management Protocol setup - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 235
task management command. 41004 QLBA_ProcessTrb: Processing unsupported head of queue App tag command Error Processing unsupported head-ofqueue task management command. MPX200 Multifunction Router User Guide 235 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 236
segment. iSCSI login failed due to unsupported version number in received login PDU. iSCSI login PDU contains invalid initiator name. The format and character set used to form the initiator name is invalid. iSCSI target login was attempted to a portal (iSCSI1 or iSCSI2) on which the target is not - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 237
due to a CHAP authentication error. iSCSI login rejected due to a CHAP key error. Failed to allocate an object for Set Port Info IOCTL processing: PortType: 0 = FC, 1 = iSCSIPortId: 0 = FC1 or iSCSI1(GE1), 1 = FC2 router as part of its discovery process. MPX200 Multifunction Router User Guide 237 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 238
QLBI_Passthru: Invalid data App length %d bytes 41717 QLBI_Passthru: Invalid data App length %d bytes 41750 QLBI_Ioctl: ERROR: Operation (0x%x) not supported in this App mode 41768 QLBI_GetLunList: REPORT LUNS App command failed 41769 QLBI_GetLunList: REPORT LUNS command failed with CHECK - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 239
to the iSNS server failed. Failed to allocate memory for TPB extension. Failed to allocate data segment descriptor (DSD) (buffer length %d). MPX200 Multifunction Router User Guide 239 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 240
feature login. Info iSCSI session discovery login. Info iSCSI login of Initiator: %s. Info iSCSI login of Target: %s. FC login occurred, origin xx (1 = Info adapter, 2 = target, 3 = initiator), VP (virtual port) xx, ID (loop ID) xx. Info FC login occurred with port ID xx.xx.xx. Info FC - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 241
processor failed DRAM diagnostic. iSCSI processor failed to return diagnostic results. Fatal Response queue entry contains an invalid handle. Fatal Set NVRAM reboot timer failed. Fatal Port disable reboot timer failed. Fatal Fatal Fatal Fatal Port enable reboot timer failed. iSNS response - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 242
loader timeout iSCSI 70938 #%d: ql_adapter_up: Failed iSCSI to initialize adapter 72351 #%d: QLProcSrblessiSNS- iSCSI Response: Invalid handle %x Fatal failed. iSCSI processor NVRAM invalid (checksum error). iSCSI controller Set Flash command failed. iSCSI controller failed to load firmware. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 243
to receive a heartbeat from the iSCSI processor for the specified number of seconds. iSCSI processor (adapter) failed to provide a heartbeat for x seconds. iSCSI processor failed to complete an abort request. out while attempting to reconnect with the iSNS. MPX200 Multifunction Router User Guide 243 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 244
74705 74746 #%d: QLProcessSystemError: iSCSI Restart RISC #%d: QLInitializeFW: MBOX_CMD_INITIALIZE_FIRMWARE failed %04x %04x %04x %04x %04x %04x iSCSI 74784 #%d: QLUpdateInitiatorData: No more room in Initiator iSCSI Database. 74800 #%d: QLSetTargetData: No more room in Target Database. - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 245
RISC #%d: QLUtmReceiveIo: Path 106583 invalid/FW No resource count FC %x 106589 #%d: QLIoctlEnable: Adapter FC disabled 106590 #%d: QLIoctlEnable: Initial- FC ize FW error Fatal FC processor firmware load was received by the driver in an IOCTL request. MPX200 Multifunction Router User Guide 245 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 246
#%d: QLIoctlRunDiag: Dia- 106592 gnostic loopback command FC failed %x % %x %x 106593 #%d: QLIoctlDisable: Re-ini- FC tialize adapter failed 106803 #%d: QLIsrEventHandler: Link FC down (%x) #%d: QLIsrEventHandler: Unex- 106813 pected async event (%x), FC MB1=%x, MB2=%x, MB3=%x, MB4= %x, - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 247
controller reported failure status for a Get Firmware State command. Request to reset the FC processor (adapter) received from IOCTL interface. FC loop initialization process (LIP) occurred. The LIP type is the FC processor's mailbox 1, 2, and 3 registers. MPX200 Multifunction Router User Guide 247 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 248
error Error Error Error Error Error Error Error Error Error Error Error Error Error Error Error Error Error Error Error RPC (remote procedure call) server initialization entry point. Get System API memory allocation failed. Get System Advanced API memory allocation failed. Get Management - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 249
. Info iSCSI port configuration has changed. Info iSNS configuration has changed. Info NTP configuration has changed. Info VLAN configuration has changed. MPX200 Multifunction Router User Guide 249 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 250
151894 qapisetlunmask_1_svc: Lun- User Info LUN mask was added for LUN %d. mask added for LUN %d 151895 qapisetlunmask_1_svc: Lun- User mask removed for LUN %d Info LUN mask was removed for LUN %d. qapisetmgmintfc151896 params_1_svc:Management port User Info Management port configuration - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 251
Setting the fan User speed to normal sysTempMon: Temperature back 152144 to safe value. Front: %dC User Rear: %dC CPU1: %dC CPU2: %dC sysTempMon: Critical Temper152145 ature, Shutting Down Front: User %dC Rear: %dC CPU1: %dC CPU2: %dC QL3022:ql3xxx_probe: Adapter Router User Guide 251 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 252
237572 "Failed to kill sys killer System %d\n" 237573 Temperature over high threshold %d System 249862 Temperature is back to nor- System mal range %d Error Error Info Failed to kill system task. Router temperature has exceeded the high temperature threshold. Router temperature has returned to - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 253
hd Error App %x AdditionalErrorStatus %x at line %d Error An error occurred on an I/O that was issued for a migration job. The description provides the job id, source and destination lun ids, as well as the error. 56321 QLMP_Logout: Virtual Target App Logged out An array Router User Guide 253 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 254
job. Info Failed to stop a migration job. Info Did not find a Migration job for the associated LUN object. Info A set array was performed on one of the arrays. Encountered an error while Info updating the migration log entry. Some migration log entries might be missing. Info Group with - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 255
serial schedule Info delayed time to invalid if the last serial schedule job was removed. Info Failed to Create a Migration Job. MPX200 Multifunction Router User Guide 255 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 256
Table 32 FCIP log messages ID Log Message Module type #%d: QLTimer: VP %d discover 119144 a reject device PID FC %02x%02x%02x #%d: QLFlashGetNvram: Inval120278 id Serial Link Control 0x%x FC for port %d 139930 FcipRoute#%d Failed with User Memory Allocation Error 139931 FcipRoute#%d - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 257
Remote remote peer has been interrupted. Check the Ethernet cabling and path to the remote peer. Indicates an error in the received FCIP PDU Framing. The router will disconnect and reconnect with the remote remote the remote router The remote peer terminated the reconnect to the remote router. The - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 258
Info Info Info Error Error Info A TCP client attempted to connect to the router, but the IP address did not match the address of the remote router specified in the route definition. Check the route definition, check for network rogues fishing for open TCP ports. Router was not able to open - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 259
HP StorageWorks EVA, HP Command View EVA, SSSU, EVA iSCSI Connectivity Kit that access the iSCSI storage. a. For Windows, mpx100. 5. Use the HP Command View EVA GUI Disks\mpx100\mpx100-D002" 6. Use the HP Command View EVA GUI or run SSSU to delete iSCSI hosts. 7. Remove the iSCSI Controllers in HP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 260
iSCSI service. ii. Configure MPIO - multipath -v3 & multipath -ll to verify. iii. Mount drives. b. Windows: i. On the Targets tab of the iSCSI Initiator applet, click the Refresh button. ii. Log in to proper targets. iii. Rescan devices and use Disk Management to mount disks. 260 HP StorageWorks - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 261
with the instruction manual, may cause this equipment without the approval of Hewlett-Packard could result in the product not meeting not expressly approved by Hewlett-Packard Company may void the product. Laser device All HP systems equipped with a laser performance standards set by government - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 262
not operate controls, make adjustments, or perform procedures to the laser device other than those specified herein. • Allow only HP authorized service technicians to repair the laser device. Certification and classification information This product contains a laser internal to the fiber optic (FO - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 263
érique de la classe A respecte toutes les exigences du Règlement sur le matériel brouilleur du Canada. BSMI notice Japanese notice MPX200 Multifunction Router User Guide 263 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 264
or mistreated. Replacement is to be done by an HP authorized service provider using the HP spare part designated for this product. For more information about battery replacement or proper disposal, contact an HP authorized service provider. WARNING! Your switch contains an internal lithium manganese - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 265
system or return them to HP, an authorized HP Partner, or their agents. For more information about battery replacement or proper disposal, contact an HP authorized reseller or service provider. Taiwan battery recycling notice The Taiwan EPA requires dry battery manufacturing or importing firms in - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 266
For more information about where you can drop off your waste equipment for recycling, contact your local city office, your household waste disposal service, or the shop where you purchased the product. Dutch notice Verwijdering van afgedankte apparatuur door privé-gebruikers in de Europese Unie Dit - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 267
de recyclage des appareils mis au rebut, veuillez contacter les autorités locales de votre région, les services de collecte des ordures ménagères ou le magasin dans lequel vous avez acheté ce produit. German in dem Sie das Gerät erworben haben. Greek notice MPX200 Multifunction Router User Guide 267 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 268
Hungarian notice Italian notice Smaltimento delle apparecchiature da parte di privati nel territorio dell'Unione Europea Questo simbolo presente sul prodotto o sulla sua confezione indica che il prodotto non può essere smaltito insieme ai rifiuti domestici. È responsabilità dell'utente smaltire le - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 269
o ambiente e a saúde das pessoas. Para obter mais informações sobre locais que reciclam esse tipo de material, entre em contato com o escritório da HP em sua cidade, com o serviço de coleta de lixo ou com a loja em que o produto foi adquirido. Slovakian notice MPX200 Multifunction Router User - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 270
Slovenian notice Spanish notice Eliminación de residuos de equipos eléctricos y electrónicos por parte de usuarios particulares en la Unión Europea Este símbolo en el producto o en su envase indica que no debe eliminarse junto con los desperdicios generales de la casa. Es responsabilidad del usuario - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 271
information is saved and restored using the MPX200 CLI commands or HP Command View EVA (see " Saving or restoring the MPX200 configuration the MPX200 using a Telnet session to the management port or the console port: Username: guest Password: password 2. Enter the following command: MPX200 Guide 271 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 272
log in: Username: ftp Password: ftp 2. Enter the following command to set the FTP transfer type to binary: ftp> bin 3. Enter the following command in to the MPX200 using a Telnet session to the management port or console port: Username: guest Password: password 5. Enter the following command: MPX200> - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 273
storage system that contains multiple disk or tape drives. A disk array, for example, is differentiated from a disk enclosure, in that the array has cache data in the face of constantly changing technology. Data migration service. A technology that simplifies data migration jobs with minimum downtime - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 274
supporting iSCSI, a user or software application issues a command to store or retrieve data on a SCSI storage remote/local replication on the entire HP StorageWorks Enterprise Virtual Array (EVA) family. The Replication Solutions Manager Software integrates with HP Business Copy EVA Software and HP - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 275
storage-device endpoint of a SCSI session. Initiators request data from targets (usually disk drives, tape drives, or other media devices). Typically, a SCSI peripheral device is the target but an adapter favor of SSH for remote access. world wide node zoning Configuring a set of Fibre Channel - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 276
276 Glossary - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 277
168 agent shutdown notification, 230 agent startup notification, 230 Apple Mac storage setup, 75 Apple Mac OS X iSCSI initiator, 57 Apple Mac iSCSI initiator, 70 array, 273 authority requirements, 167 B bandwidth, 273 battery replacement notice, 264 beacon command, 169 blade command, 169 C CHAP, 273 - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 278
set, 182 set alias, 183 set chap, 184 set chassis, 184 set fc, 185 set features, 186 set iscsi, 186 set isns, 186 set mgmt, 187 set ntp, 188 set properties, 188 set snmp, 188 set system, 189 set related documentation, 163 documentation HP website, 163 E EVA, 273 EVA storage systems, 54 exit command, - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 279
troubleshooting, 157 I image command, 175 initiator command, 176 initiator object table, 220 initiator setup Linux, 75 VMware, 82 initiators 10-GbE, 26 number of paths required, 25 number of, 25 Input Power LED, 153 Installation planning, 24 IP network adapters supported storage HP EVA storage array - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 280
set alias command, 183 set chap command, 184 set chassis command, 184 set command, 182 set fc command, 185 set features command, 186 set iscsi command, 186 set isns command, 186 set mgmt command, 187 set ntp command, 188 set properties command, 188 set snmp command, 188 set system command, 189 set - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 281
HP, 164 support fabric, 56 Fibre Channel switch, 56 multipath software, 56 operating system, 56 supported maximums, SUSE Linux installing and configuring, 75 System Alert LED, 154 system information objects, 229 T tabs Connected Targets, 78 Discovered Targets, 76 Target Settings, 101 Taiwan battery - HP XP20000/XP24000 | HP StorageWorks MPX200 Multifunction Router User Guide (569 - Page 282
282
HP StorageWorks
MPX200 Multifunction Router User Guide
This user guide describes the MPX200 Multifunction Router, which supports the EVA and XP families of Fibre
Channel storage systems for integrated iSCSI connectivity, FCIP, FCoE (EVA only), and data migration. The
MPX200 hardware is integrated with up to four EVA or XP24000/20000 storage systems and HP Command
View EVA (EVA only) to deliver multi-protocol capabilities, including Fibre Channel, iSCSI, FCIP, and FCoE. This
document is intended for system administrators with knowledge of HP StorageWorks EVA4x00/6x00/8x00
and XP24000/20000 storage systems, configuring LUNs using HP Command View, HP Fibre Channel SANs,
Ethernet, TCP/IP networking, iSCSI, FCIP, FCoE.
Part Number: 5697-0568
Seventh edition: August 2010