HP StorageWorks XP Disk Array Configuration Guide for Novell Netware XP24000, XP20000, XP12000, XP10000 Part number: A5951-96055 Seventh edition: September 2007 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 2
L.P. Confidential computer software. Valid license from HP required for possession, use or copying. HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 3
and symbols 7 Conventions for storage capacity values 8 Graphical interface illustrations ...9 HP technical support ...9 Subscription service ...9 HP websites ...9 Documentation feedback ...9 1 Installing and configuring Novell Netware for the XP disk array 11 Features and requirements ...11 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 4
Configuring NetWare 6.x Servers for Cluster Services 27 Installing Cluster Services 27 Creating logical volumes 28 3 Troubleshooting 31 Error conditions ...31 Calling the HP support center ...32 Contact information ...32 Before you call ...32 A Path worksheet 33 Worksheet ...33 B Disk array - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 5
Figures 1..SNMP configuration 13 2..Arbitrated loop fabric topology example 16 3..Multi-cluster environment 18 XP Disk Array Configuration Guide for Novell Netware 5 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 6
Tables 1..Document conventions 7 2..Fabric topology settings 16 3..SAN fabric zoning and LUN security settings 18 4..Error conditions ...31 5..Path worksheet ...33 6..Supported emulations 35 7..Emulation specifications 35 6 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 7
Manager Web Client User's Guide • HP StorageWorks SAN Design Reference Guide You can find these documents from the Manuals page of the HP Business Support Center website: http://www.hp.com/support/manuals In the Storage section, click Disk Storage Systems and then select your product. Document - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 8
clarifying information or specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. Conventions for storage capacity values HP XP storage systems use the following values to calculate physical storage capacity values (hard disk drives): • 1 KB - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 9
• http://www.hp.com/support/manuals Documentation feedback HP welcomes your feedback. To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. XP Disk Array Configuration Guide for Novell Netware - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 10
10 About this guide - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 11
details. • (Recommended) HP StorageWorks XP Remote Web Console, HP StorageWorks XP Command View Advanced Edition Software or HP StorageWorks XP Command View with LUN management feature for configuring disk array ports and paths. • (Recommended) HP StorageWorks XP Array Manger. • (Optional - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 12
. SNMP properties are usually set from the SVP but they can also be set remotely using XP Remote Web Console, or XP Command View . For procedures, refer to the applicable user guide available at: http://www.hp.com/support/manuals. 12 Installing and configuring Novell Netware for the XP disk array - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 13
, use XP Remote Web Console, XP Command View, XP Command View Advanced Edition Software, or XP Array Manager to complete the remaining tasks listed below. If you do not have these programs, your HP service representative can perform these tasks for you. XP Disk Array Configuration Guide for Novell - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 14
host mode for each disk array port to match the host OS. Set the host mode using LUN Manager in XP Remote Web Console (shown), XP Command View, or XP Command View Advanced Edition Software. If these are not available, the HP service representative can set the host mode using the SVP. The host mode - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 15
(AL-PA) or loop ID for each port. For specific values, refer to the HP StorageWorks XP LUN Manager User's Guide applicable to your array. Fabric and connection parameter settings When configuring the disk array, use LUN Manager in XP Remote Web Console, XP Command View, or XP Command View Advanced - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 16
configuration utilities supported by HP and the FCA manufacturer. Installing and configuring the FCAs Install and configure the Fibre Channel adapters using the FCA manufacturer's instructions. Configuring NetWare Client NetWare 6.x 16 Installing and configuring Novell Netware for the XP disk array - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 17
storage environment. ConsoleOne is a free Java utility used to manage network resources. Configure default settings on the next page and click Finish. Fabric zoning and LUN security If you plan to use clustering, install and configure disk array. XP Disk Array Configuration Guide for Novell Netware 17 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 18
shared port Connecting the disk array to the NetWare server The HP service representative connects the disk array to the host by: 1. Verifying operational status of the disk array channel adapters, LDEVs, and paths. 2. Connecting the Fibre Channel cables between the disk array and the fabric switch - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 19
), or XP Command View Advanced Edition Software to define paths (LUNs) between hosts and volumes in the disk array. This process is also called "LUN mapping." In XP Remote Web Console and XP Command View, LUN mapping includes: • Configuring ports • Enabling LUN security on the ports • Creating host - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 20
Record the device number for each new device on the worksheet in "Path Worksheet" on page 33. This information will be useful later during disk partitioning and volume creation. 4. Verify that all new disk devices are listed. Configuring disk devices Configure the disks in the disk array using the - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 21
On the Create a new partition screen, select the desired device, select NSS in the Type box, and click OK. 6. Enter the size of the partition in bytes (B), kilobytes (KB Enter NSSMU at the server console 2. In the main menu, select "Partitions." XP Disk Array Configuration Guide for Novell Netware 21 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 22
or contact Novell customer support. NetWare 5.x 1. On the Available Disk Options screen, click NetWare key. The Segment List of Volume Disk screen displays the existing devices by device number. The Volume assignment column displays "(free configuring Novell Netware for the XP disk array - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 23
/device, enter the desired Volume Quota, then click Next. 5. In the Create Logical Volume - Storage Information window check Activate and Mount in the "On Creation" box, then click Finish. 6. Confirm that the logical volume has been created. XP Disk Array Configuration Guide for Novell Netware 23 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 24
the server console. 2. In configuring the Novell NetWare system, verify that NetWare clients can access the new volumes. To verify access: 1. Copy an existing file onto each new volume. 2. Verify that the file was copied successfully. 24 Installing and configuring Novell Netware for the XP disk array - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 25
products with the disk array, contact your HP service representative for the latest information about support and configuration requirements. For assistance with NHAS or SFT III operations, see the Novell user documentation, or contact Novell customer support. Multipath failover The XP disk arrays - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 26
> This command sets the priority level for each path. The ID must be a valid path ID, and the number must be a decimal integer value in the range 1-4,000,000, with 1 being the highest priority and 4,000,000 being the lowest priority. The default value of 0 (zero) indicates that there is no - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 27
server in the cluster. • All servers must be in the same NDS tree. • Cluster Services running on each server in the cluster. • All servers must have a connection to the shared disk array. • All cluster servers configured with the IP protocol and on the same IP subnet. • One client running Windows 98 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 28
default Storage box, then click Finish. 6. Confirm that the logical volume has been created. 7. Map the created Logical Volume as the Network Drive. 8. Confirm the mapped drive. Netware 6.5 1. Enter NSSMU at the server console. 2. In the main menu, select Volumes. 28 Middleware configuration - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 29
3. Press Insert and enter a name for the new volume, then click Next. 4. Select the desired pool/device, enter the desired Volume Quota, then click Next. 5. Review and change volume attributes as necessary. 6. Select Create. XP Disk Array Configuration Guide for Novell Netware 29 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 30
30 Middleware configuration - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 31
resolve an error condition, ask your HP support representative for assistance. See "Calling the HP support center" on page 32. Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: • In XP Remote Web Console (Status tab) • In XP Command - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 32
simplifying the configuration. Calling the HP support center If you are unable to resolve an error condition, contact the HP support center for assistance. Contact information Telephone numbers for worldwide technical support are listed on the HP support web site: http://www.hp.com/support/. Before - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 33
LDEV (CU:LDEV) (CU = Device Type SCSI Bus control unit) Number 0:00 Path 1 0:01 0:02 0:03 0:04 0:05 0:06 0:07 0:08 0:09 0:10 Alternate Paths TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: TID: LUN: TID: LUN: TID: LUN: TID: LUN: XP Disk Array Configuration Guide for Novell Netware 33 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 34
34 Path worksheet - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 35
B Disk array supported emulations This appendix provides information about supported emulations and emulation specifications. Some parameters may not be relevant to your array. Consult your HP representative for information about supported configurations for your system. Supported emulations HP - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 36
number of volumes combined together. For example, with 8 combined volumes: OPEN-V*8. Note 1: The availability of an emulation depends on the disk array. Note 2: The devices are defined to the host as SCSI disk devices, even though the interface is Fibre Channel. 36 Disk array supported emulations - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 37
Raid Manager) is distinguished by -CM on the product name (for example, OPEN-3-CM, OPEN-3-CVS-CM × 4 = 53 × 4 = 212 OPEN-V: The number of cylinders for a CVS LUSE volume = # of cylinders = (capacity (MB) specified by user) × 16/15 × n Example XP Disk Array Configuration Guide for Novell Netware 37 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 38
is specified in MB, not number of cylinders. The capacity of an OPEN-V CVS volume can be specified in MB or number of cylinders. You set the volume size using XP Remote Web Console, XP Command View (XP arrays only), or XP Command View Advanced Edition Software. 38 Disk array supported emulations - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 39
as two-digit hexadecimal numbers. For example, host mode 08 represents an HP-UX host. Logical device. An LDEV is created when a RAID group is carved into pieces according to the selected host emulation mode (that is, OPEN-3, OPEN-8, XP Disk Array Configuration Guide for Novell Netware 39 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 40
Management Protocol. Service processor, which is the PC built into the disk array. The SVP provides a direct interface into the disk array. SVP use is reserved for HP support representatives only. Storage Virtualization System, an appliance that manages multiple disk array storage systems. Target - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 41
View, a software product for managing XP arrays. XP Command View runs on a Windows-based management workstation. HP StorageWorks XP Remote Web Console. A browser-based program installed on the SVP that allows you to configure and manage the disk array. XP Disk Array Configuration Guide for Novell - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 42
42 Glossary - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 43
, 19 type specifications, 36 verifying, 19 disk array(s) connecting, 18 features, 11 installation overview, 13 Not Ready error message, 32 operating system versions, 11 requirements, 11 self reboots, 32 server support, 11 storage capacity, 11 support for middleware products, 25 disk, partitions, 20 - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 44
connecting disk array, 18 HP service representative tasks, 13 overview, 13 interface, Fibre Channel, 11 L logical volumes, 25 cannot be created, 31 LUN(s) creating, 19 mapping, 19 security, 17, 18 M middleware configuration, 25 disk array support, 25 multi-cluster environment, 17 multi-path failover - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 45
support, 27 product manuals, 7 worksheet, path, 33 X XP Array Manager, 11, 13, 15, 19 XP Command View, 11, 13, 15, 19 XP Command View Advanced Edition Software, 11, 13, 19 XP family storage capacity, 11 XP Remote Web Console, 11, 13, 19 Z zoning, fabric, 17, 18 XP Disk Array Configuration Guide - HP XP20000 | HP StorageWorks XP Disk Array Configuration Guide for Novell Netwar - Page 46