HP StorageWorks XP Disk Array Configuration Guide for IBM AIX XP24000, XP12000, XP10000, SVS200 Part number: A5951-96047 Ninth edition: June 2007 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 2
L.P. Confidential computer software. Valid license from HP required for possession, use or copying. HP products and services are set forth in the express warranty statements accompanying such products and services. Nothing herein should be construed as constituting an additional warranty. HP - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 3
the new devices to volume groups 22 Creating the Journaled File Systems 25 Mounting and verifying the file systems 27 2 Troubleshooting 29 Error conditions ...29 Calling the HP support center ...30 Contact information ...30 Before you call ...30 XP Disk Array Configuration Guide for IBM AIX 3 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 4
A Path worksheet 31 Worksheet ...31 B Disk array supported emulations 33 Supported emulations ...33 Emulation specifications ...33 Disk parameters by emulation type 36 Byte information table ...44 Physical partition size table ...45 Glossary 47 Index 51 4 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 5
Figures 1..SNMP configuration 13 2..Point-to-point fabric topology example 16 3..Multi-cluster environment 18 XP Disk Array Configuration Guide for IBM AIX 5 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 6
Device parameters-read/write timeout and queue type 20 6..Device parameters-queue depth 20 7..Error conditions ...29 8..Path worksheet ...31 9..Supported emulations 33 10..Emulation specifications 33 11..OPEN-3 parameters by emulation type 36 12..OPEN-8 parameters by emulation type 38 13..OPEN - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 7
• HP StorageWorks XP24000 Disk Array: Owner's Guide • HP StorageWorks 200 Storage Virtualization System: Owner's Guide • HP StorageWorks XP LUN Manager User's Guide • HP StorageWorks SAN Design Reference Guide • HP StorageWorks Command View XP Advanced Edition Software Device Manager Web Client User - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 8
, tabs, and check boxes Text emphasis • File specific instructions. NOTE: Provides additional information. TIP: Provides helpful hints and shortcuts. Conventions for storage capacity values HP XP storage systems use the following values to calculate physical storage capacity values (hard disk - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 9
product resources. HP websites For additional information, see the following HP websites: • http://www.hp.com • http://www.hp.com/go/storage • http://www.hp.com/service_locator • http://www.hp.com/support/manuals Documentation feedback HP welcomes your feedback. XP Disk Array Configuration Guide - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 10
To make comments and suggestions about product documentation, please send a message to [email protected]. All submissions become the property of HP. 10 About this guide - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 11
details • (Recommended) HP StorageWorks XP Remote Web Console, HP StorageWorks Command View XP Advanced Edition Software or HP StorageWorks XP Command View with LUN management feature for configuring disk array ports and paths • (Recommended) HP StorageWorks XP Array Manager • (Optional) Check - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 12
. SNMP properties are usually set from the SVP but they can also be set remotely using XP Remote Web Console, XP Command View (XP arrays only), or Command View XP Advanced Edition Software. Refer to the applicable user's guide for procedures. 12 Installing and configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 13
done with XP Remote Web Console, XP Command View (XP arrays only), or Command View XP Advanced Edition Software to . Refer to the applicable user guide for information about how to designate a command device. Installation roadmap Perform the following actions to install and configure the disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 14
for each disk array port to match the host OS. Set the host mode using LUN Manager in XP Remote Web Console (shown), XP Command View (XP arrays only), or Command View XP Advanced Edition Software. If these are not available, the HP service representative can set the host mode using the SVP. The host - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 15
software configuration of the host. Configuring the Fibre Channel ports Configure the disk array Fibre Channel ports by using XP Remote Web Console (shown), XP Command View (XP arrays only), or Command View XP Advanced Edition Software. Select the settings for each port based on your storage area - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 16
, refer to the HP StorageWorks SAN Design Reference Guide at: http://www.hp.com. Figure 2 Point-to-point fabric topology example Table 3 Fabric topology settings Fabric Parameter Connection Parameter ON FC-AL Provides Not supported 16 Installing and configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 17
disk array. Loading the operating system and software Follow the manufacturer's instructions to load the operating system and software onto the host. Load all OS patches and configuration utilities supported by HP nodes share access to the disk array. XP Disk Array Configuration Guide for IBM AIX 17 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 18
through a shared port Connecting the disk array The HP service representative connects the disk array to the host by: 1. Verifying operational status of the disk array channel adapters, LDEVs, and paths. 2. Connecting the Fibre Channel cables between the disk array and the fabric switch or host - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 19
StorageWorks XP LUN Manager User's Guide or HP StorageWorks Command View XP Advanced Edition Software Device Manager Web Client User's Guide. Note the LUNs and their ports, WWNs, nicknames, and LDEVs for later use in verifying host and device configuration. Verifying host recognition of disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 20
In this example, the emulation type, LDEV number, CU number and array port designation should all be displayed for disk device hdisk3. Configuring disk array devices Disks in the disk array are configured using the same procedure for configuring any new disk on the host. This includes the following - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 21
system. You can adjust the queue depth setting to optimize the I/O performance of the disk array. Displaying the device parameters using the AIX command line At the command line prompt, ASCII session, use the smit -C command. 2. Select Devices. Example XP Disk Array Configuration Guide for IBM AIX 21 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 22
Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance & Resource Scheduling System Environments Processes & Subsystems Applications Using SMIT (information only) 3. Select Fixed Disk 22 Installing and configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 23
Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem of a Volume Group List Contents of a Volume Group Remove a Volume Group Activate a Volume Group Deactivate a Volume Group XP Disk Array Configuration Guide for IBM AIX 23 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 24
SIZE in megabytes PHYSICAL VOLUME names Activate volume group AUTOMATICALLY at system restart? Volume Group MAJOR NUMBER [vg01] 4 [hdisk1] yes [] 7. Enter yes or no in the Activate volume group Repeat these steps for each volume group needed. 24 Installing and configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 25
System Storage Management (Physical & Logical Storage) Security & Users Communications Applications and Services Print Spooling Problem Determination Performance Group of File Systems Verify a File System Backup a File System Restore a File System XP Disk Array Configuration Guide for IBM AIX 25 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 26
Show Characteristics of a Journaled File System Remove a Journaled File System Defragment a Journaled File (in 512-byte blocks). Enter the lsvg command to display the number of free physical partitions and physical partition size. Calculate the maximum size configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 27
of bytes per node. Enter the number of bytes appropriate for the application, or use the default value. Example Add a Journaled File System Type or select values in entry / 551448 46% 6997 5% /usr 5512 32% 66 6% /var 11608 52% 38 0% /tmp XP Disk Array Configuration Guide for IBM AIX 27 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 28
4% 16 1% /hp01 /dev/lv02 14401536 13949392 4% 16 1% /hp02 HACMP and HAGEO do not provide a complete disaster recovery or backup solution and are not a replacement for standard disaster recovery planning and backup/recovery methodology. 28 Installing and configuring AIX for the XP disk array - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 29
to resolve an error condition, ask your HP support representative for assistance. See Calling the HP support center. Error conditions Depending on your system configuration, you may be able to view error messages (R-SIMS) as follows: • In XP Remote Web Console (Status tab) • In Command View XP - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 30
and that disk array TIDs do not conflict with any host TIDs. Calling the HP support center If you are unable to resolve an error condition, contact the HP support center for assistance. Contact information Telephone numbers for worldwide technical support are listed on the HP support web site: http - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 31
LDEV (CU:LDEV) (CU = Device Type SCSI Bus control unit) Number 0:00 Path 1 0:01 0:02 0:03 0:04 0:05 0:06 0:07 0:08 0:09 0:10 Alternate Paths TID: LUN: TID: LUN: TID: LUN: TID: LUN: TID: TID: LUN: TID: LUN: TID: LUN: TID: LUN: XP Disk Array Configuration Guide for IBM AIX 31 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 32
32 Path worksheet - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 33
Yes Yes Yes NOTE: For the SVS200, and the XP24000/XP12000/XP10000 when connected to external storage devices, HP recommends using OPEN-V as the emulation the array makes visible to the host. This allows external storage LDEVs to be configured without losing data. Using any other emulation may cause - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 34
96 15 96 15 128 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 6 Note 1: The availability of an emulation depends on the disk array. Note 2: The devices are defined to the host as SCSI disk devices, even though the interface is Fibre Channel. 34 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 35
/720 × n Example For a CVS LUSE volume with capacity = 37 MB and n = 4: # of cylinders = 37 × 1024/720 × 4 = 52.62 × 4 = 53 × 4 = 212 OPEN-V: The number of cylinders for a CVS LUSE volume =# of cylinders = (capacity (MB) specified by user) × 16/15 × n XP Disk Array Configuration Guide for IBM AIX 35 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 36
of an OPEN-V CVS volume can be specified in MB or number of cylinders. You set the volume size using XP Remote Web Console, XP Command View (XP arrays only), or Command View XP Advanced Edition Software. Disk parameters by emulation type Table 11 OPEN-3 parameters by emulation type Parameter - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 37
optionally2 Set optionally Depends on configuration of CV3 Set optionally Set optionally Set optionally Set optionally Set optionally 8,192 Set optionally 8,192 8,192 8,192 8,192 8,192 8,192 1,024 1,024 1,024 1,024 Set optionally 1,024 1,024 1,024 XP Disk Array Configuration Guide for IBM AIX 37 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 38
Disk category dt Control type ns Sectors/tracks nt Tracks/cylinder nc Number of all cylinders OPEN-8 Winchester SCSI 96 15 9,966 rm Number of rotations of the disk on configuration of CV1 Set optionally2 Set optionally Depends on configuration of CV1 38 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 39
1,024 1,024 1,024 1,024 1,024 1,024 1,024 Emulation Type OPEN-9*n (n=2 to OPEN-9 CVS 36) Winchester Winchester SCSI SCSI OPEN-9 CVS*n (n=2 to 36) Winchester SCSI XP Disk Array Configuration Guide for IBM AIX 39 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 40
on configuration of CV1 Set optionally Set optionally Set optionally Set optionally Set optionally 8,192 8,192 Set optionally2 Set optionally Depends on configuration of CV3 Set optionally Set optionally Set optionally Set optionally Set optionally 8,192 8,192 40 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 41
Number of all cylinders OPEN-E Winchester SCSI 96 15 19,759 rm Number of rotations of the disk configuration of CV1 6,300 6,300 Set optionally Set optionally OPEN-E CVS*n (n=2 to 36) Winchester SCSI 116 15 Depends on configuration of CV3 6,300 Set optionally XP Disk Array Configuration Guide - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 42
Set optionally Set optionally 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 Set optionally2 Set optionally Depends on configuration of CV3 Set optionally Set optionally Set optionally Set optionally Set optionally 8,192 8,192 8,192 8,192 8,192 8,192 8,192 8,192 42 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 43
-x CVS volume can be obtained by the following calculation ( means round up to integer): The number of cylinders = (specified capacity in megabytes from SVP or remote console) × 1,024 / 720 × n where n is the number of concatenated volumes for LUSE. XP Disk Array Configuration Guide for IBM AIX 43 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 44
Category OPEN-3 OPEN-8 OPEN-9 OPEN-3/8/9 CVS OPEN-3/8/9*n CVS OPEN-E OPEN-L OPEN-x CVS LU product name Number of bytes per Inode OPEN-3 OPEN-3*2 to OPEN-3*28 4096 OPEN-3*29 to OPEN-3*36 8192 OPEN 16384 OPEN-3 CVS, OPEN-9 CVS, OPEN-E CVS, OPEN-V CVS 4096 44 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 45
Physical partition size table Table 16 Physical partition size Category LU product name OPEN-3 OPEN-8 OPEN-9 OPEN-E OPEN-L OPEN-x*n CVS OPEN-3 OPEN-3*2 to OPEN-3*3 OPEN-3*4 to OPEN-3*6 32 64 128 256 8 16 32 64 128 256 16 32 64 128 256 64 128 256 2 XP Disk Array Configuration Guide for IBM AIX 45 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 46
Category LU product name 1801 to 2300 2301 to 7000 7001 to 16200 13201 to 32400 32401 to 64800 64801 to 126000 126001 to 259200 259201 - 518400 518401 and higher Physical partition size in megabytes 4 8 16 32 64 128 256 512 1024 46 Disk array supported emulations - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 47
-L: 36 GB OPEN-V: User-defined custom size Disconnecting a failed unit or path and replacing it with an alternative unit or path in order to continue functioning. Fibre Channel. Fibre Channel arbitrated loop. Fibre Channel Protocol. Host bus adapter. XP Disk Array Configuration Guide for IBM AIX 47 - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 48
Protocol. Service processor, which is the PC built into the disk controller. The SVP provides a direct interface into the disk array. SVP use is reserved for HP support representatives only. Storage Virtualization System, an appliance that manages multiple disk array storage systems. Target - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 49
View, a software product for managing XP arrays. XP Command View runs on a Windows-based management workstation. HP StorageWorks XP Remote Web Console. A browser-based program installed on the SVP that allows you to configure and manage the disk array. XP Disk Array Configuration Guide for IBM AIX - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 50
50 Glossary - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 51
, 21 recognition, 19 type specifications, 34 verifying, 19 volume groups, 22 disk array(s) configuration, 14 connecting, 18 features, 11 installation overview, 13 Not Ready error message, 30 operating system versions, 11 self reboots, 30 server support, 11 storage capacity, 11 system requirements - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 52
"SCSI disk", 12 security, LUN, 17 server, support, 11 SIMS, 29 SNMP configuration, 13 storage capacity, 11 storage capacity values conventions, 8 Subscriber's Choice, HP, 9 System Option Mode, setting, 15 T technical support, 30 HP, 9 service locator website, 9 topology, fabric, 16 troubleshooting - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 53
11, 19 XP Array Manager , 14 XP arrays storage capacity, 11 XP Business Copy Software, 13 XP Command View, 11, 13, 14, 15, 19 XP Continuous Access Software, 13 XP RAID Manager command devices, 13 XP Remote Web Console, 11, 13, 14, 15, 19 Z zoning, fabric, 17 XP Disk Array Configuration Guide for IBM - HP XP24000 | HP StorageWorks Disk Array XP operating system configuration guide - Page 54
54
HP StorageWorks
XP Disk Array Configuration Guide for IBM AIX
XP24000, XP12000, XP10000, SVS200
Part number: A5951–96047
Ninth edition: June 2007