Hikvision DS-2TP21B-6AVF/W Configuration Guide

Hikvision DS-2TP21B-6AVF/W Manual

Hikvision DS-2TP21B-6AVF/W manual content summary:

  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 1
    042120NA How To Configure Highly Accurate DS-2TP21B-6AVFW Thermographic Handheld Camera 1. General Parameters • Temperature Measurement Range 86°− temperature on measured body surface temperature could be reduced. © 2020 Hikvision USA Inc. All Rights Reserved. 18639 Railroad Street, City of
  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 2
    , except for tripod adapters that should be purchased together with the products, tripods that meet the standards could be purchased locally. © 2020 Hikvision USA Inc. All Rights Reserved. 18639 Railroad Street, City of Industry, CA 91748 • Phone: +1 909-895-0400 • Fax: +1 909-595-0788 Questions
  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 3
    User Interface of this handheld thermographic camera is as shown below. Figure 3, Interface • Configuration Notes 1. Go to Settings >> Local Settings >> Thermography Settings. 2. Set Emissivity to 0.98. 3. Set Distance to the actual distance between the camera and measured object. © 2020 Hikvision
  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 4
    as required. When the measured value exceeds the set value, the displayed Max Temp. Value turns red and flashes, as shown below. © 2020 Hikvision USA Inc. All Rights Reserved. 18639 Railroad Street, City of Industry, CA 91748 • Phone: +1 909-895-0400 • Fax: +1 909-595-0788 Questions: techsupport
  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 5
    or for outdoor measurements are not recommended normally. Under these circumstances, the temperature measurement accuracy may not meet the same standard. © 2020 Hikvision USA Inc. All Rights Reserved. 18639 Railroad Street, City of Industry, CA 91748 • Phone: +1 909-895-0400 • Fax: +1 909-595-0788
  • Hikvision DS-2TP21B-6AVF/W | Configuration Guide - Page 6
    042120NA First Choice for Security Professionals Technical Support © 2020 Hikvision USA Inc. All Rights Reserved. 18639 Railroad Street, City of Industry, CA 91748 • Phone: +1 909-895-0400 • Fax: +1 909-595-0788 Questions: [email protected] • www.hikvision.com 6
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6

042120NA
© 2020 Hikvision USA Inc. All Rights Reserved.
18639 Railroad Street, City of Industry, CA
91748
Phone: +1 909-895-0400
Fax: +1 909-595-0788
Questions:
www.hikvision.com
1
How To Configure Highly Accurate
DS-2TP21B-6AVFW Thermographic Handheld Camera
1.
General Parameters
Temperature Measurement Range
86
°-
113
°
F (30.0
°-
45.0
°
C)
Temperature Measurement Accuracy
0.9
°
F (±0.5
°
C)
Camera Resolution
Thermal: 160 × 120, Optical: 640 × 480
Operating Environment
A stable indoor environment without wind or direct sunlight
Working temperature: 50
°-
95
°
F (10
°-
35
°
C)
2.
Installation
Installation Cautions
The performance of this temperature-screening scheme is greatly affected by the
environment. This scheme would apply only to indoor environments or scenarios with
calm air and consistent temperature. Besides, the relative installation location of
devices also greatly affects the temperature measurement accuracy. In order to improve
measurement accuracy, the installation environment has to meet certain requirements:
-
Select installation environments with one-direction path to ensure that cameras
capture the full faces of all passing persons. It is recommended that people stop
movement during measurements.
-
Select indoor environments with calm air and consistent temperature condition.
Outdoor environments with rapid temperature changes are not recommended.
-
If this scheme is used in entrance scenes that connect indoor and outdoor
environments, it is suggested that the installation location be kept at a certain
distance from the entrance (such as customs or security checkpoints). Persons
coming in from outdoors should stay indoors for more than five minutes before the
measurement. In these ways, the influence of the outdoor temperature on
measured body surface temperature could be reduced.