    Projector CP-A200 User's Manual (detailed) Technical Example of PC signal Resolution (H x V) H. cases. Refer to the number of display pixels above. • Although the projector can display signals with resolution up to UXGA (1600x1200), the signal will be converted to the projector's panel resolution
  • Hitachi CP-A200 | Technical Manual - Page 2
    are used for the initial settings. The signal timing of some PC models may be different. In such case, adjust the items V POSITION and H POSITION in IMAGE Menu. Back porch (B) Front porch (D) Back porch (b) Front porch (d) Data H. Sync. Active time (C) Sync (A) Data V. Sync. Active time
  • Hitachi CP-A200 | Technical Manual - Page 3
    Connection to the ports Connection to the ports C B A MONITOR OUT COMPUTER IN2 COMPUTER IN1 1 CONTROL Y CB/PB CR/PR VIDEO L R AUDIO IN3 S-VIDEO AUDIO OUT 2 AUDIO IN A COMPUTER IN1, B COMPUTER IN2, C MONITOR OUT D-sub 15pin mini shrink jack • Video signal: RGB separate, Analog, 0.7Vp-p,
  • Hitachi CP-A200 | Technical Manual - Page 4
    Connection to the ports (continued) MONITOR OUT D COMEPUTER IN2F COMPGUTER IN1 1 CONTROL H Y CB/PB CR/PR VIDEO L R AUDIO IN3 S-VIDEO AUDIO OUT 2 AUDIO IN D Y, E CB/PB, F CR/PR (component video) RCA jack x3 • System: 480i@60, 480p@60, 576i@50, 576p@50, 720p@50/60, 1080i@50/60, 1080p@50/60
  • Hitachi CP-A200 | Technical Manual - Page 5
    RGB signal; ex.: SCART connector (jack) SCART cable (plug) Y CB/PB CR/PR VIDEO L R AUDIO IN3 RCA plugs To input SCART RGB signal to the projector, use a SCART to RCA cable. Connect the plugs refer to above ex.. For more reference, please consult your dealer. 5
  • Hitachi CP-A200 | Technical Manual - Page 6
    Connection to the ports (continued) N MONITOR OUT COMPUTER IN2 COMPUTER IN1 1 CONTROL Y CB/PB CR/PR VIDEO L R AUDIO IN3 S-VIDEO AUDIO OUT 2 AUDIO IN N CONTROL D-sub 9pin plug • About the details of RS-232C communication, please refer to the following page. Pin Signal 1 (No connection) 2
  • Hitachi CP-A200 | Technical Manual - Page 7
    RD (3) TD (4) DTR (5) GND (6) DSR (7) RTS (8) DTS (9) RI Connecting the cable RS-232C port of the computer 1. Turn off the projector and the computer. 2. Connect the CONTROL port of the projector with a RS-232C port of the computer by a RS-232C cable (cross). Use the cable that fulfills the speci
  • Hitachi CP-A200 | Technical Manual - Page 8
    projector. Header + Command data ('01H' + '00H' + type (2 bytes) + setting code (2 bytes)) (2) The projector changes the setting based on the above setting code. (3) The projector projector cannot properly receive the command. In such a case code, the projector ignore the excess the projector receives an
  • Hitachi CP-A200 | Technical Manual - Page 9
    F[Lens door error]il 01 00 [Cover error] 05 00 [Air flow error] 00 ( ter 02 00 [Fan error] 07 00 [Cold error] 03 00 [Lamp error] 08 00 [Filter error] BE EF 03 06 00 89 D2 02 00 03 20 00 00 BE EF 03 06 00 EF D2
  • Hitachi CP-A200 | Technical Manual - Page 10
    Reset User Gamma Point 2 User Gamma Point 2 Reset User Gamma Point 3 User Gamma Point 3 Reset User Gamma Point 4 User Gamma Point 4 Reset User Gamma Point 5 User Gamma Point 5 Reset User Gamma Point 6 User Gamma Point 6 Reset User Gamma Point 7 User Gamma Point 7 Reset User Gamma Point 8 User Gamma
  • Hitachi CP-A200 | Technical Manual - Page 11
    RS-232C communication (continued) Names Operation Type Header COLOR TEMP Set HIGH BE EF 03 06 00 CUSTOM-1 (HIGH) BE EF 03 06 00 MID BE EF 03 06 00 CUSTOM-2 (MID) BE EF 03 06 00 LOW BE EF 03 06 00 CUSTOM-3 (LOW) BE EF 03 06 00 Hi-BRIGHT-1 BE EF 03 06 00 CUSTOM-4 (Hi-BRIGHT-1) BE EF 03
  • Hitachi CP-A200 | Technical Manual - Page 12
    RS-232C communication (continued) Names Operation Type COLOR COLOR Reset TINT TINT Reset SHARPNESS SHARPNESS Reset MY MEMORY Load Set MY MEMORY Save Set PROGRESSIVE Set VIDEO NR Set ASPECT Set Get Increment Decrement Execute Get Increment Decrement Execute Get Increment Decrement Execute 1
  • Hitachi CP-A200 | Technical Manual - Page 13
    RS-232C communication (continued) Names Operation Type OVER SCAN OVER SCAN Reset V POSITION V POSITION Reset H POSITION H POSITION Reset H PHASE H SIZE H SIZE Reset AUTO ADJUST COLOR SPACE Set COMPONENT Set C-VIDEO FORMAT Set S-VIDEO FORMAT Set Get Increment Decrement Execute Get Increment
  • Hitachi CP-A200 | Technical Manual - Page 14
    RS-232C communication (continued) Names Operation Type FRAME LOCK - Set COMPUTER1 FRAME LOCK - Set COMPUTER2 COMPUTER IN1 Set COMPUTER IN2 Set D-ZOOM D-ZOOM Reset D-SHIFT V D-SHIFT V Reset D-SHIFT H D-SHIFT H Reset KEYSTONE V KEYSTONE V Reset KEYSTONE H KEYSTONE H Reset PERFECT FIT Set PERFECT
  • Hitachi CP-A200 | Technical Manual - Page 15
    RS-232C communication (continued) Names Operation Type PERFECT FIT Right Top corner -V PERFECT FIT Left Bottom corner -H PERFECT FIT Left Bottom corner -V PERFECT FIT Right Bottom corner -H PERFECT FIT Right Bottom corner -V PERFECT FIT all corners Reset PERFECT FIT Left side distortion
  • Hitachi CP-A200 | Technical Manual - Page 16
    RS-232C communication (continued) Names Operation Type MONITOR OUT - Set COMPUTER1 MONITOR OUT - Set VIDEO MONITOR OUT - Set S-VIDEO MONITOR OUT - Set COMPUTER2 MONITOR OUT - Set COMPONENT MONITOR OUT - Set STANDBY VOLUMECOMPUTER1 VOLUMECOMPUTER2 VOLUMECOMPONENT VOLUME-S-VIDEO VOLUME-VIDEO
  • Hitachi CP-A200 | Technical Manual - Page 17
    RS-232C communication (continued) Names Operation Type AUDIO-COMPUTER1 Set AUDIO-COMPUTER2 Set AUDIO-COMPONENT Set AUDIO-S-VIDEO Set AUDIO-VIDEO Set AUDIO OUT STANDBY Set REMOTE RECEIVE. Set FRONT REMOTE RECEIVE. Set TOP REMOTE FREQ. Set NORMAL REMOTE FREQ. Set HIGH AUDIO1 AUDIO2 AUDIO3 Turn off
  • Hitachi CP-A200 | Technical Manual - Page 18
    03 06 00 9B D0 01 00 Get BE EF 03 06 00 08 D3 02 00 *Your projector may not support all of these language. Please check the LANGUAGE menu to find the supported languges. 05 30 05 30 05 30 05 30 05 30 05 30 05 30 05 30 05
  • Hitachi CP-A200 | Technical Manual - Page 19
    communication (continued) Names Operation Type BLANK On/Off START UP MyScreen LOCK MESSAGE TEMPLATE TEMPLATE On/Off AUTO SEARCH AUTO ON AUTO OFF LAMP TIME LAMP TIME Reset FILTER TIME FILER TIME Reset MY BUTTON-1 Set TURN OFF TURN ON Get Set MyScreen ORIGINAL TURN OFF Get Set TURN OFF
  • Hitachi CP-A200 | Technical Manual - Page 20
    RS-232C communication (continued) Names Operation Type MY BUTTON-2 MY SOURCE MAGNIFY H Position at Magnify V Position at Magnify FREEZE CLOSED CAPTION DISPLAY CLOSED CAPTION MODE CLOSED CAPTION CHANNEL COMPUTER1 COMPUTER2 COMPONENT S-VIDEO VIDEO INFORMATION MY MEMORY PICTURE MODE FILTER
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20

1
Projector
CP-A200
User's Manual (detailed)
Technical
Resolution (H x V)
H. frequency (kHz)
V. frequency (Hz)
Rating
Signal mode
720 x 400
37.9
85.0
VESA
TEXT
640 x 480
31.5
59.9
VESA
VGA (60Hz)
640 x 480
37.9
72.8
VESA
VGA (72Hz)
640 x 480
37.5
75.0
VESA
VGA (75Hz)
640 x 480
43.3
85.0
VESA
VGA (85Hz)
800 x 600
35.2
56.3
VESA
SVGA (56Hz)
800 x 600
37.9
60.3
VESA
SVGA (60Hz)
800 x 600
48.1
72.2
VESA
SVGA (72Hz)
800 x 600
46.9
75.0
VESA
SVGA (75Hz)
800 x 600
53.7
85.1
VESA
SVGA (85Hz)
832 x 624
49.7
74.5
Mac 16” mode
1024 x 768
48.4
60.0
VESA
XGA (60Hz)
1024 x 768
56.5
70.1
VESA
XGA (70Hz)
1024 x 768
60.0
75.0
VESA
XGA (75Hz)
1024 x 768
68.7
85.0
VESA
XGA (85Hz)
1152 x 864
67.5
75.0
VESA
1152 x 864 (75Hz)
1280 x 960
60.0
60.0
VESA
1280 x 960 (60Hz)
1280 x 1024
64.0
60.0
VESA
SXGA (60Hz)
1280 x 1024
80.0
75.0
VESA
SXGA (75Hz)
1280 x 1024
91.2
85.0
VESA
SXGA (85Hz)
1600 x 1200
75.0
60.0
VESA
UXGA (60Hz)
1280 x 768
47.7
60.0
VESA
W-XGA (60Hz)
1400 x 1050
65.3
60.0
VESA
SXGA+ (60Hz)
1280 x 800
49.7
60.0
VESA
1280 x 800 (60Hz)
NOTE
• Be sure to check jack type, signal level, timing and resolution before
connecting this projector to a PC.
• Some PCs may have multiple display screen modes. Use of some of these
modes will not be possible with this projector.
• Depending on the input signal, full-size display may not be possible in some
cases. Refer to the number of display pixels above.
• Although the projector can display signals with resolution up to UXGA
(1600x1200), the signal will be converted to the projector’s panel resolution before
being displayed. The best display performance will be achieved if the resolutions
of the input signal and projector panel are identical.
• Automatic adjustment may not function correctly with some input signals.
• The image may not be displayed correctly when the input sync signal is a
composite sync or a sync on G.
Example of PC signal