    Projector CP-X505/CP-X605 User's Manual - Network Functions This manual is only intended to explain Network Functions. For safety, operations or any other issues, refer to the all user's manual for this projector. WARNING • Before using the network functions, read the all user's manual for this
  • Hitachi CPX605 | Network Functions - Page 2
    requires maintenance or has encountered an error. (26) Projector Management via SNMP This projector is SNMP (Simple Network Management Protocol) compliant, allowing you to monitor it from a remote location using SNMP software. In addition, the projector is able to send failure & warning alerts to
  • Hitachi CPX605 | Network Functions - Page 3
    ... To use the network functions of this projector, the projector must be configured to suit your network. Consult with your network administrator before connecting the projector to your network. Incorrect network configuration of this projector may cause problems on your network. Connect to the
  • Hitachi CPX605 | Network Functions - Page 4
    can adjust or control the projector via a network from a web browser on a PC that is connected to the same network. NOTE • Internet Explorer 5.5 is especially recommended that all users running Internet Explorer on a Microsoft Windows version prior to Windows XP Service Pack 2 install security update
  • Hitachi CPX605 | Network Functions - Page 5
    and administrator IDs. Item Description Administrator ID User ID Network Information Displays the projector's current network configuration settings. √ √ Network Settings Displays and configures network settings. √ N/A Port Settings Displays and configures communication port settings
  • Hitachi CPX605 | Network Functions - Page 6
    for configuring or controlling the projector via a web browser. Example: If the IP address of the projector is set to 192.168.1.10 will be displayed. Fig. 2 (Logon with administrator ID) Fig. 3 (Logon with user ID) 3) Click the desired operation or configuration item on the main menu located on
  • Hitachi CPX605 | Network Functions - Page 7
    All screen images displayed in this manual are screens of a logon using an administrator ID. Any administrator only functions will not be displayed when using a user ID. Refer to the descriptions in each table. Displays the projector's current network configuration settings. Item DHCP IP Address
  • Hitachi CPX605 | Network Functions - Page 8
    settings. Item IP Configuration DHCP ON DHCP OFF IP Address Subnet Mask Default Gateway Projector Name SysLocation SysContact Description Configures network settings. Enables DHCP. Disables DHCP. Configures the IP address when DHCP is disabled. Configures the Subnet Mask when DHCP is disabled
  • Hitachi CPX605 | Network Functions - Page 9
    ] check box to use the e-mail function. Click the [Apply] button to save the settings. NOTE • The new configuration settings are activated after restarting the network connection. The network connection must be restarted when the configuration settings are changed. The
  • Hitachi CPX605 | Network Functions - Page 10
    ] button to save the settings. NOTE • You can confirm whether the mail settings work correctly using the [Send Test Mail] button. • If you connect the projector to an existing network, consult a network administrator before setting server addresses. 10
  • Hitachi CPX605 | Network Functions - Page 11
    Alert Settings Settings Displays and configures failure & warning alerts. Item Cover Error SNMP Trap Send Mail Mail Subject Mail Text Fan Error SNMP Trap Send Mail Mail Subject Mail Text Description Configures Cover Error alert settings. Click the [Enable] check box to enable SNMP Trap alerts
  • Hitachi CPX605 | Network Functions - Page 12
    Mail Text Temp Error SNMP Trap Send Mail Mail Subject Mail Text Air Flow Error SNMP Trap Send Mail Mail Subject Mail Text Description Configures Lamp Error alert settings. Click the [Enable] check box to enable SNMP Trap alerts for this item. Click the [Enable] check box to enable e-mail alerts
  • Hitachi CPX605 | Network Functions - Page 13
    Time Error SNMP Trap Send Mail Mail Subject Mail Text Cool Error SNMP Trap Send Mail Mail Subject Mail Text Filter Error SNMP Trap Send Mail Mail Subject Mail Text Description Configures Lamp Time Error alert settings. Click the [Enable] check box to enable SNMP Trap alerts for this item. Click the
  • Hitachi CPX605 | Network Functions - Page 14
    the text of the e-mail to be sent. The length of the text can be up to 1024 alphanumeric characters. Lamp Time Alarm Configures Lamp Time Alarm alert settings. Alarm Time Configures the lamp time to alert. SNMP Trap Click the [Enable] check box to enable SNMP Trap alerts for this item. Send
  • Hitachi CPX605 | Network Functions - Page 15
    ) Item Description Filter Time Alarm Configures Filter Time Alarm alert settings. Alarm Time Configures the filter time to alert be up to 1024 alphanumeric characters. "CHANGE THE LAMP" is Configures alert settings for when "CHANGE THE LAMP" is displayed displayed. SNMP Trap Click the [
  • Hitachi CPX605 | Network Functions - Page 16
    settings. Item Daily Schedule Schedule List Sunday Schedule Schedule List Monday Schedule Schedule List Tuesday Schedule Schedule List Wednesday Schedule Schedule List Thursday Schedule Schedule List Friday Schedule Schedule List Saturday Schedule Schedule List 16 Description Configures the daily
  • Hitachi CPX605 | Network Functions - Page 17
    Settings Schedule Setting (Continued) Item Specific date No1 Schedule Month/Day Schedule List Specific date No.2 Schedule Month/Day Schedule List Specific date No.3 Schedule Month/Day Schedule List Specific date No.4 Schedule Month/Day Schedule List Specific date No.5 Schedule Month/Day Schedule
  • Hitachi CPX605 | Network Functions - Page 18
    for display of transfer image data. Click the [Register] button to add new commands to the Schedule List. Click the [Delete] button to delete commands from the Schedule list. Date/Time Settings Displays and configures the date and time settings. Item Current Date Current Time Description
  • Hitachi CPX605 | Network Functions - Page 19
    must be restarted when the configuration settings are changed, The network connection can be restarted using [Network Restart] on the main menu. • If you connect the projector to an existing network, consult a network administrator before setting server addresses. • To enable the SNTP function
  • Hitachi CPX605 | Network Functions - Page 20
    Administrator Password Re-enter the above password for verification. User authority Configures the User ID and Password. User ID Configures the User ID. The length of the text can be up to 32 alphanumeric characters. User Password Configures the User Password. The length of the text can be up
  • Hitachi CPX605 | Network Functions - Page 21
    Settings Security Settings (Continued) Item Description Network Control Configures the Authentication Password for the The new configuration settings are activated after restarting the network connection. The network connection must be restarted when the configuration settings are changed. The
  • Hitachi CPX605 | Network Functions - Page 22
    the up and down arrow keys on the PC. Most of the items have a submenu. Refer to the table below for details. Controls the projector. Item Main Power Input Source Picture Mode Blank On/Off Mute Freeze Magnify Picture Brightness Contrast Gamma Color Temp Color Tint Sharpness Active Iris MyMemory
  • Hitachi CPX605 | Network Functions - Page 23
    Projector Control Projector Control (Continued) Item Description Image Aspect Selects the Aspect setting. Over . Component Selects the Component terminal setting. C-Video Format Selects the Video Format setting. S-Video Format Selects the S-Video Format setting. M1-D Selects the M1-D
  • Hitachi CPX605 | Network Functions - Page 24
    Audio-M1-D input terminal. Assigns the Audio-Video input terminal. Assigns the Audio-S-Video input terminal. Assigns the Audio-Component input terminal to shut off the projector when no signal is detected. Assigns the functions for the MY BUTTON1 buttons on the included remote control. Assigns the
  • Hitachi CPX605 | Network Functions - Page 25
    lamp. Displays the usage time for the current filter. Displays the current power status. Displays the current input signal source. Displays the Blank On/Off status. Displays the current Mute On/Off status. Displays the current Freeze On/Off status. Network Restart Restarts the projector's network
  • Hitachi CPX605 | Network Functions - Page 26
    the SMTP Port configuration settings have changed. Click [Network Restart] and configure the following items. 6) C lick [Mail Settings] and configure each item. Refer to the [Mail Settings] item in [Configuring and Controlling the Projector via a Web Browser] for further information. 7) Click the
  • Hitachi CPX605 | Network Functions - Page 27
    Click [Alert Settings] on the main menu. 9) Select and configure each alert item. Refer to [Alert Settings] in [Configuring and Controlling the Projector via a Web Browser] for further information. 10) Click the [Apply] button to save the settings. Failure/Warning e-mails are formatted as follows
  • Hitachi CPX605 | Network Functions - Page 28
    Alerts to a specified PC. NOTE • It is recommended that SNMP functions be carried out by a network administrator. • SNMP management software must be installed on the computer to monitor the projector via SNMP. SNMP settings (9) Configure the following items via a web browser to use SNMP. Example
  • Hitachi CPX605 | Network Functions - Page 29
    Controlling the Projector via Scheduling The projector can be automatically controlled via scheduling. NOTE • You can schedule the following control events: Power ON/OFF, Input Source and Transferred Image Display. • There are 3 types of Scheduling, 1) daily 2) day of the week 3) specific date
  • Hitachi CPX605 | Network Functions - Page 30
    the Projector via a Web Browser] for further information. 3) Click the [Apply] button to save the settings. NOTE • A Network Restart been set correctly. Replace the battery by following the instructions on replacing the battery. (User's Manual - Operating Guide : Replacing Internal Clock battery)
  • Hitachi CPX605 | Network Functions - Page 31
    ] check box to enable scheduling. 5) Enter the Date (Month/Day) for specific date scheduling. 6) Click [Add] and set the hour, command and parameters When the schedule function is used, the power cord must be connected to the projector and the outlet and the power switch must be turned on, [ | ].
  • Hitachi CPX605 | Network Functions - Page 32
    e-SHOT (Still Image Transfer) Display e-SHOT (Still Image Transfer) Display The projector can display a still image that is transferred via the network. Communication Port The following port is used for e-SHOT. TCP #9716 (9) NOTE • e-SHOT is not available via communication ports which are used for
  • Hitachi CPX605 | Network Functions - Page 33
    The network connection can be restarted using [Network Restart] on the main menu. e-SHOT (Still Image Transfer) Transmission e-SHOT transmission requires an exclusive application for your PC. You can download it from the Hitachi web site. Refer to the manual for the application for instructions. 33
  • Hitachi CPX605 | Network Functions - Page 34
    Command Control via the Network Command Control via the Network You can configure and control the projector via the network using RS-232C commands. web browser when command control is used. Example: If the IP address of the projector is set to 192.168.1.10: 1) Enter [https://192.168.1.10] into the
  • Hitachi CPX605 | Network Functions - Page 35
    Click the [Apply] button to save the settings. * See Note2. NOTE1 • The Authentication Password will be the same for [Network Control Port1 (Port: 23)], [Network Control Port2 (Port: 9715)], and [Image Transfer Port (Port: 9716)]. NOTE2 • The new configuration settings are activated after restarting
  • Hitachi CPX605 | Network Functions - Page 36
    Command Control via the Network Command format Command formats differ among the different communication ports. TCP #23 You can use the RS-232C commands without any changes. The reply data
  • Hitachi CPX605 | Network Functions - Page 37
    Command Control via the Network Reply Data format The connection ID (the data is same Reply 0x1C Error code 2 bytes Reply Data 0x1D 2 bytes Reply Status code 0x1F 2 bytes Reply 0x1F Authentication Error code
  • Hitachi CPX605 | Network Functions - Page 38
    Command Control via the Network Automatic Connection Break The TCP connection will be automatically disconnected after there is no communication for 30 seconds after being established. Authentication The projector does not accept commands without authentication success when authentication is enabled
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38

±
Projector
CP-X505/CP-X605
User’s Manual – Network Functions
This manual is only intended to explain Network Functions.
For safety, operations or any other issues, refer to the all user's manual for this
projector.
• Before using the network functions, read the all user's manual
for this projector carefully to ensure your projector is set up correctly.
• After reading, keep the manuals in a safe place for future reference.
WARNING
• The information in this manual is subject to change without notice.
• The manufacturer assumes no responsibility for any errors that may appear in
this manual.
• The reproduction, transfer or copy of all or any part of this document is not
permitted without express written consent.
NOTE
Contents
Network Functions
..................................................................
2
Settings
...................................................................................
6
Projector Control
...................................................................
22
Failure & Warning Alerts via E-mail
......................................
26
Projector Management via SNMP
..........................................
28
Controlling the Projector via Scheduling
..............................
29
e-SHOT(Still Image Transfer) Display
...................................
32
Command Control via the Network
.......................................
34
Trademark acknowledgment
• Windows is a registered trademark of Microsoft Corporation.
• Netscape is a registered trademark of Netscape Communications Corporation.
• JavaScript is a registered trademark of Sun Microsystems, Inc.
All other trademarks are the properties of their respective owners.