Homelite HG5022P Quick Start Guide

Homelite HG5022P Manual

Homelite HG5022P manual content summary:

  • Homelite HG5022P | Quick Start Guide - Page 1
    . (b) If desired, install frame supports and wheels with enclosed hardware. See page 11 of the operator's manual for instructions. 988000-044 2-15-10 (REV:01) b, e For questions or clarification on these CALL Quick Start Guide instructions, contact us at www.homelite.com 1-800-242-4672
  • Homelite HG5022P | Quick Start Guide - Page 2
    un nivel máximo de combustible a 1 de pulgada por debajo de la parte superior del tanque de combustible. (f) Vuelva a colocar la tapa de combustible. las instruccionnes correspondientes en el manual del operador. ¿NECESITA AYUDA? 1-800-242-4672 LLAME AL www.homelite.com Si tiena alguna pregunta
  • 1
  • 2

WARNING:
Do not connect to a building’s electrical system
unless the generator and transfer switch have been
properly installed and the electrical output has
been verified by a qualified electrician
.
3
ADD LUBRICANT
AND FUEL
(a) Move generator ouside to a
flat, level surface.
(b) Remove oil cap/dipstick.
(c)
Use a funnel to pour the supplied lubricant into the
engine. Fill to the upper mark of the oil dipstick. Use
caution to avoid spilling.
(d) Replace oil cap/dipstick.
(e) Remove fuel cap and fill with REGULAR UNLEADED
fuel. Do not overfill. Keep maximum fuel level 1 inch
below the top of the fuel tank.
(f)
Replace fuel cap.
Quick Start Guide
5000 Watt Portable Generator
1
UNPACK GENERATOR
(a)
Do not attempt to lift
generator out of the carton.
Cut each corner of the
carton to open and lay
carton flat.
(b)
Prior to assembly check to
ensure you have all the included items.
If items are missing or damaged call 1-800-242-4672.
Typical Generator Shown
Exhaust Port
Pointed away
from dwelling
openings
2
BASIC ASSEMBLY
(a) Move generator to a flat, level surface.
(b) If desired, install frame supports and wheels with
enclosed hardware. See page 11 of the operator’s
manual for instructions.
For questions or
clarification on these
Quick Start Guide
instructions, contact us at
1-800-242-4672.
Product style and configuration
may vary.
CALL
www.homelite.com
4
MOVE GENERATOR TO SAFE
OPERATING LOCATION
(a)
Move generator outside to a flat, level surface, away
from doors, windows and vents.
5
START GENERATOR
(a)
Turn fuel valve under tank to the ON position.
(b)
Move choke lever fully to the right.
(c)
Select the ON position on the engine switch.
(d)
Start generator by slowly pulling on the recoil starter grip
until resistance is felt. Then pull cord rapidly to overcome
compression to start engine.
(e)
Slowly move choke lever fully to the left as engine
warms.
6
USING GENERATOR
(a)
With generator running, power is now provided to the
receptacles.
(b) Allow generator to
warm up for 3 to 5
minutes, then plug in
items to be powered,
using only grounded
extension cords.
WARNING: DO NOT
overload generator or
electrical cords.
7
SHUT DOWN AND STORAGE
PROCEDURES
(a)
Before shutting engine off, unplug all electrical loads.
(b)
Let engine run for 2 minutes.
(c)
Turn engine switch to OFF.
(d)
Turn fuel valve to OFF.
(e)
If generator is to be stored for longer than 30 days, refer
to the operator’s manual for further instructions.
ITEMS INCLUDED:
Operator’s Manual
Generator with Portability Kit
Engine Lubricant
ITEMS NEEDED:
Utility Knife
7/16 in. Socket Wrench
T27 Torx Driver
Oil Funnel
Unleaded Fuel
WARNING:
This Quick Start Guide is not a substitute for reading the operator’s manual.
To reduce the risk of injury or death, user must read and understand operator’s manual before using this product.
988000-044
2-15-10 (REV:01)
b, e
c
d
a