Honeywell 6150V Installation Guide

Honeywell 6150V Manual

Honeywell 6150V manual content summary:

  • Honeywell 6150V | Installation Guide - Page 1
    /VISTA-20P). This mode must be enabled at the control panel. Refer to the control panel's installation and setup guide for information on how to program the chime mode. • Use only zone descriptors supported by this keypad. If using zone descriptors not supported by this keypad, you must turn voice
  • Honeywell 6150V | Installation Guide - Page 2
    the keypad address, voice chime mode, and additional voice keypad mode. Setting The Keypad Address When used with the VISTA-15P/VISTA-20P control panels, address 16 must be assigned to the first Keypad. Additional Keypads must be set at 17 - 23 and must be enabled additionally in control programming
  • 1
  • 2

K0022V2 12/01
Rev. B
ADEMCO 6150V & 6160V
Voice Remote Keypads
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
The ADEMCO 6150V and ADEMCO 6160V are addressable
remote keypads designed for use with ADEMCO control
panels and provide the following features:
Backlit Display
Voice Chime
Programmable Function
Keys
Voice Status
Message Center
Built-in Sounder
Notes:
When used with the ADEMCO VISTA-15P/VISTA-
20P control panels, address 16 must be assigned to
the first keypad.
Additional keypads must be
assigned to address 17 – 23.
Refer to Setting The
Keypad Options.
Keypad keys are continuously backlit for convenience.
Permanent display backlighting is an option on some
controls (refer to the control panel’s instructions for
details).
Voice Chime should only be enabled when used with
control panels that support the "chime by zone" mode
(e.g., VISTA-15P/VISTA-20P).
This mode must be
enabled at the control panel.
Refer to the control panel's
installation and setup guide for information on how to
program the chime mode.
Use only zone descriptors supported by this
keypad.
If using zone descriptors not supported
by this keypad, you must turn voice status and
voice chime off.
Table 1 is a list of applicable zone
descriptors and index entries.
Refer to
the control
panel’s installation and setup guide for information
about how to program zone descriptors.
KEYPAD DISPLAYS AND LEDS
The keypads have the following display features:
Model
Fixed
Word
Display
2-Line
Alpha
Display
2-Digit
Zone
Identifier
Custom
Zone
Descriptors
6150V
X
X
6160V
X
X
The following table identifies the keypad’s LEDs and
associated functions:
LED
Function
ARMED
Lights red when the system is armed in any mode.
READY
Lights green when the system is "ready" to be
armed.
MESSAGE
Flashes red when message waiting or lights red
(steady) when in record mode.
PROGRAMMABLE FUNCTION KEYS
The keypad's programmable function keys [A, B, C] are
normally used for keypad panic functions, but they can be
programmed for other special functions instead.
If they are
programmed for other special functions, the associated
keypad key pairs still provide the respective panic alarm (if
programmed).
Refer to the control panel’s Installation &
Setup Guide for details.
Function
Keys
Equivalent Key Pairs
A
[1] and [*]
B
[*] and [#]
C
[3] and [#]
D
NONE
Function keys must be held down for at
least 2 seconds to activate the programmed
function.
If functions other than panics are assigned
to
the
programmable
function
keys,
programmed panics must be initiated by
pressing the programmed key pair.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
symbols (i.e., fire, police, personal emergency, etc.) is
provided.
These labels can be placed on or next to the keys
to identify each key's function for the end user (as
determined by the capability and programming of the
control panel; refer to the installation and setup guide for
the control panel).
6160V-001-V1
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
1
OFF
4
MAX
7
INSTANT
READY
2
AWAY
5
TEST
8
CODE
0
3
STAY
6
BYPASS
9
CHIME
#
SIDE
VIEW
D
C
B
A
WIRING AND INSTALLATION
Keypads can be surface mounted using drywall anchors or
to a single- or double-gang electrical box.
1.
Remove the case back
by pushing up the two "snaps"
along the keypad’s bottom edge and pulling the case
apart.
See diagram above.
2.
Route wiring from the control panel
through the
opening in the case back.
3.
Mount the case back
to a wall or electrical box.
4.
Wire directly from the keypad’s terminal block
to
the terminal block on the control board. (See Wiring
Table that follows.)
Wiring Table (All Keypads)
Keypad
Control Panel
Wire Color
G
Data In
Green
– Aux Pwr (GND)
Black
+
+ Aux. Pwr
Red
Y
Data Out
Yellow
5.
Re-attach the keypad
to the case back.
6.
Remove clear protective film from LEDs (6160V