Honeywell HPFF12 Operation Manual - Page 31
Mounting Six-Circuit Modules from Honeywell Fire Systems, 2.5 Power-Limited Wiring Requirements
View all Honeywell HPFF12 manuals
Add to My Manuals
Save this manual to your list of manuals |
Page 31 highlights
Power-Limited Wiring Requirements Installation 2.4.2 Mounting Six-Circuit Modules from Honeywell Fire Systems Six-output addressable modules can be mounted directly to the control circuit board as shown in Figure 2.15 for the wall cabinet. This allows wiring to remain in the cabinet. However, the sixoutput module cannot be mounted as shown in the HPFF12CM(E) units when used in the large equipment enclosure. An optional multi-module chassis is available from Honeywell Fire Systems. See Section 2.5, "Power-Limited Wiring Requirements". HPFF12mnt6up.wmf Figure 2.15 Mounting Details for Six-Output Modules from Honeywell Fire System 2.5 Power-Limited Wiring Requirements Power-limited and non-power-limited circuit wiring must remain separated in the cabinet. All power-limited wiring must remain at least 0.25" away from any non-power-limited circuit wiring. Furthermore, all power-limited circuit wiring and non-power-limited circuit wiring must enter and exit the cabinet through different conduits. An example of this is shown below. Your specific application may require different conduit knockouts to be used in the standard cabinet. Any conduit knockouts may be used. For power-limited applications, use of conduit is optional. HPFF12 NAC Expander - P/N 53576:B 11/24/2010 31