Honeywell HPTV2404 Specifications

Honeywell HPTV2404 Manual

Honeywell HPTV2404 manual content summary:

  • Honeywell HPTV2404 | Specifications - Page 1
    Honeywell Power Products 12 Clintonville Road Northford, CT 06472 http://www.honeywellpower.com HPTV2404(CB) PRODUCT INSTALLATION DOCUMENT PN 52404:A 01/17/2005 ECN 04-507 HPTV2404(CB): CCTV Power Supply and Distribution Units 1 Overview The HPTV2404 and HPTV2404CB Installation Instructions 1.
  • Honeywell HPTV2404 | Specifications - Page 2
    between power limited wiring (output circuits on HPTV2404CB) and non-power limited wiring. Use separate moisture, and disconnect power before servicing unit. For continuous protection against Support: (800) 627-3473 • Email us: [email protected] 2 HPTV2404(CB) Installation Instructions
  • 1
  • 2

HPTV2404(CB) PRODUCT INSTALLATION DOCUMENT
PN 52404:A
01/17/2005
ECN 04-507
Honeywell Power Products
12 Clintonville Road
Northford, CT 06472
HPTV2404(CB):
CCTV Power Supply and Distribution Units
1 Overview
The
HPTV2404
and
HPTV2404CB
are CCTV power supply and distribution units.
They provide a constant source of
24 VAC with 4 A supply current.
Four individual outputs route power to operate CCTV Cameras and other video
accessories. For overload protection the HPTV2404 uses automotive style fuses and the HPTV2404CB has auto-
resettable PTCs.
2 Specifications
Input 115 VAC, 60 HZ, 1 A.
4 A, 24 VAC (100 VA) supply current.
Four outputs
Note: Individual Output Circuits can be loaded to 3.0 A on HPTV2404 or 2.0 A on HPTV2404CB provided the total
current from all output combined is limited to 4.0 A.
Surge and transient protection.
Transformer has built in thermal protection.
LED Indicator Lights:
Input Power LED (Green) – ON indicates that 24 VAC is present at distribution board
Output Power LEDs (4 Green) – ON indicates that 24 VAC is present at the related output circuit.
Overload Protection (HPTV2404):
Terminal Block Fuse: 3 A, 250 V, 5x20MM Cartridge
Main Secondary Fuse: 5 A, 32 V, Automotive Style
Individual Output Circuit Fuses: 3 A, 32 V, Automotive Style
Overload Protection (HPTV2404CB):
Terminal Block Fuse: 3A, 250V, 5x20MM Cartridge
Individual Output Circuit PTC: Hold Current (2.0 A at 50°C)
SPECIAL NOTE: To reset a PTC that has experienced an overload or short circuit, disconnect power for 5 minutes
to allow the PTC to reset itself.
Power ON/OFF switch.
AC line cord included.
Unit maintains camera synchronization.
Vented enclosure with hinged door and five convenient knockouts.
Design for quick installation.
Maximum temperature range 32°F to 120°F (0°F to 49°C); indoor use only.
Cabinet dimensions 11.5" W x 4.875" D x 10" H (29.21 cm W x 12.38 cm D x 25.4 cm H)
3
Installation Instructions
1.
Unpack product and discard all packing materials.
2.
Pre-drill holes where enclosure is to be mounted.