Honeywell HW2000i Owners Manual

Honeywell HW2000i - Portable Inverter Generator Manual

Honeywell HW2000i manual content summary:

  • Honeywell HW2000i | Owners Manual - Page 1
    Inverter Generator Owner's Manual Guide D'Utilisation Manual del Propietario HW1000i HW2000i For product inquires or support, please visit www.honeywellgenerators.com or call toll-free at 1-888-HWHELP1 (494-3571). Pour obtenir des renseignements sur les produits ou pour du soutien
  • Honeywell HW2000i | Owners Manual - Page 2
    on owning a Honeywell inverter generator! WARNING This manual contains important instructions for operating this generator. For your safety, and the safety of others, be sure to read this manual thoroughly before operating the generator. Failure to properly follow all instructions and precautions
  • Honeywell HW2000i | Owners Manual - Page 3
    REMINDERS AND SPECIAL OFFERS FROM HONEYWELL GENERATORS CHECK HERE TO RECEIVE INFORMATION FROM HOME WORK TYPE OF WORK, IF PRODUCT BEING USED FOR PROFESSION: FEATURES INFLUENCING PRODUCT PURCHASE: BRAND REPUTATION EASE OF USE PORTABILITY SIZE / WEIGHT POWER RATING STYLE/APPEARANCE PRICE
  • Honeywell HW2000i | Owners Manual - Page 4
    - $29,999 $30,000 - $49,999 $50,000 - $79,999 $80,000 - $99,999 $100,000 - $124,999 $125,000 - $149,999 $150,000 - $174,999 $175,000 - $199, DISCOVER AMERICAN EXPRESS GAS / RETAIL OTHER NONE HOUSEHOLD INTERESTS: HOME IMPROVEMENT AUTOMOTIVE WORK CAMPING OTHER THANK YOU FOR REGISTERING YOUR PRODUCT
  • Honeywell HW2000i | Owners Manual - Page 5
    Storing Generator ...26 TROUBLESHOOTING ...27 SPECIFICATIONS AND WIRING DIAGRAMS 29 WARRANTIES ...33 NORTHSHORE POWER SYSTEMS CONSUMER LIMITED WARRANTY 33 NORTHSHORE POWER SYSTEMS EMISSIONS CONTROL WARRANTY 34 INDEX ...37 MAINTENANCE PARTS 39 HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 6
    THIS PAGE INTENTIONALLY LEFT BLANK ii www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 7
    KILL YOU IN MINUTES. Generator exhaust contains carbon monoxide. This is a poison you cannot see or smell. NEVER use inside a home Only use OUTSIDE and far or garage, EVEN IF doors away from windows, doors, and and windows are open. vents. HW1000i / HW2000i Inverter Generator Owner's Manual www
  • Honeywell HW2000i | Owners Manual - Page 8
    way. • NEVER tamper with governed speed. Generator sup- plies correct rated frequency and voltage when running at governed speed. • Damage to generator caused by misuse or modification is not covered under Warranty. 2 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 9
    utilice dentro del hogar Utilícelo siempre AFUERA ni del garaje AUNQUE estén y lejos de ventanas, abiertas las puertas y las ventanas. puertas y ventilas. B p/n: 1015 91A H PART NUMBER 101589A 101591A HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 3
  • Honeywell HW2000i | Owners Manual - Page 10
    (732-6458) p/n 101596A SMART START INSTRUCTIONS ALL USERS MUST READ AND UNDERSTAND OWNER'S MANUAL! TOUS LES UTILISATEURS DOIVENT LIRE ET COMPRENDRE LE GUIDE D'UTILISATION! TODOS LOS USUARIOS DEBEN LEER Y COMPRENDER EL MANUAL OPERACIÓN! HW2000i ! 1 MOVE INVERTER OUTSIDE. DÉPLACEZ L'ONDULATEUR
  • Honeywell HW2000i | Owners Manual - Page 11
    : Part Number: AC/DC Voltage: Power Output: Max. Ambient Temp.: Serial Number: HW2000i 101440A 120V/12V 2.0kW 40oC Phase: 1 Frequency: 60Hz Engine RPM: 5000 Fuel: Gasoline Insulation Class: F FIGURE 3: Generator Nameplate Location HW1000i / HW2000i Inverter Generator Owner's Manual www
  • Honeywell HW2000i | Owners Manual - Page 12
    having jurisdiction. • In some areas, generators are required to be registered with local utility companies. • If generator is used at a construction site, there may be additional regulations which must be observed. 6 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 13
    assistance to lift the generator to avoid back or other bodily injury. Accessories Oil Drain Pipe Oil Fill Container Screwdriver Handle FIGURE 5: Inverter Accessories Screwdriver Universal Bit Spark Plug Wrench HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 7
  • Honeywell HW2000i | Owners Manual - Page 14
    . 6. Oil Alert Indicator Light Illuminates red when low oil conditions are present and the generator is running (or while recoil is pulled). The engine will automatically stop to prevent generator damage. 8 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 15
    H-Fuel Valve Controls flow of fuel from fuel tank to carburetor. I- Primer Bulb (HW2000i model only) Provides primer fuel to start engine. J-Choke Control Controls choke valve. Choke control must be in the ON position when starting a cold engine. HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 16
    THIS PAGE INTENTIONALLY LEFT BLANK 10 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 17
    is placed outdoors in a well ventilated area. ‰ Check/add engine oil- IMPORTANT! BEFORE STARTING GENERATOR, FILL WITH ENGINE OIL. See page 18 -p. 21 for instructions on filling, checking, and changing oil. ‰ Check/add fuel-ADD FUEL. See page 22. ‰ Check air filter-See "Air Filter Maintenance
  • Honeywell HW2000i | Owners Manual - Page 18
    appliances plugged in and turned on. • Do not move the generator while it is running. 1. Fill the fuel tank and check oil is to appropriate level. NOTE: The generator starts more easily with a full fuel tank. 2. Place the generator outside on a flat surface free of debris to prevent blocking the
  • Honeywell HW2000i | Owners Manual - Page 19
    engine. Starting Generator Starting Generator 12. After starting, confirm the output ready indicator light is green and stays on. FIGURE 11: Prime Engine NOTE: INITIAL START: Depress the primer bulb 30-50 times to prime the fuel lines. NOTE: If the generator has a low fuel tank or has been run to
  • Honeywell HW2000i | Owners Manual - Page 20
    on horsepower will be greater than this if no carburetor modification is made. NOTICE If engine jetted for high altitude is used at lower altitude, lean air fuel mixture will reduce performance and may over-heat and seriously damage the engine. HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 21
    Heater, Portable Typical Running Watts 3500 500-1440 50-1210 10 900-1200 120 / 30 or less 150 / 30 or less 50 785 1200-2400 (using drying feature greatly increases energy consumption) 1800-5000 60 / 100 65-175 55-250 750* 1200-1875 750-1500 HW1000i / HW2000i Inverter Generator Owner's Manual www
  • Honeywell HW2000i | Owners Manual - Page 22
    4500-5500 Water Pump, Deep Well* 250-1100 TABLE 2. Typical Appliance Running Wattages *Allow up to three times normal running watts for starting this appliance. NOTE: Appliances in grey require a higher wattage output than the inverter generator will produce. NOTICE Starting appliances that
  • Honeywell HW2000i | Owners Manual - Page 23
    when using generator in dusty areas. ‡ HW2000i model only. ** It is recommended that this maintenance task be performed by a service dealer. Every 6 months or 100 hours of use Every year or 200 hours of use X X X** X** HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators
  • Honeywell HW2000i | Owners Manual - Page 24
    the oil level is low, add oil (see "Engine Oil Recommendations") to the oil fill container (included). DO NOT OVERFILL. HW1000i Oil Capacity [qt / ml] 0.26 / 250 TABLE 4. Engine Oil Capacity HW2000i 0.48 / 450 18 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 25
    of the engine fill hole. Hot engine oil can cause severe burns. • ALWAYS stop engine before removing the oil fill cap. 5. Remove the back maintenance cover using the Phil- lips end of the universal screwdriver bit. HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 19
  • Honeywell HW2000i | Owners Manual - Page 26
    Cap Removal 8. Attach the oil drain pipe (do not over tighten) and tilt the generator allowing the oil to completely drain into the oil pan. FIGURE 25: Drain Oil (HW2000i Model) 20 www.honeywellgenerators.com FIGURE 27: Oil Fill Measurement HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 27
    to a conventional unleaded gasoline. NOTICE Oxygenated fuels can damage paint and plastic. Be careful not to spill fuel when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty. HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 21
  • Honeywell HW2000i | Owners Manual - Page 28
    use stale or contaminated gasoline or oil/gasoline mixture. Avoid getting dirt or water in fuel tank. Use fresh gasoline with a pump octane rating of 87 or higher. 1. Stop the generator if the engine is running. Allow to completely cool. 2. Place the generator on a flat, level surface. 3. Remove
  • Honeywell HW2000i | Owners Manual - Page 29
    restrict air flow to the carburetor, which may cause poor engine performance or damage. Never run the generator without the air cleaner assembly the air filter in clean engine oil. FIGURE 36: Air Filter Oiling HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 23
  • Honeywell HW2000i | Owners Manual - Page 30
    Wire brush 1. Stop the generator if the engine is running. Allow to completely cool. 2. Place the generator on a flat, level of skin exposed to used oil with soap and water. NOTE: The engine will smoke during initial start-up if too much oil is left in the / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 31
    Service Spark Plug Service Spark Plug Service To ensure proper engine operation, the spark plug must be properly gapped and free of deposits. WARNING If the engine has been running Parts at the end of this manual. HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 25
  • Honeywell HW2000i | Owners Manual - Page 32
    adjacent to the generator. 4. Remove the fuel cap and drain all the fuel into a con- tainer. FIGURE 44: Draining Fuel 5. When ready to put the generator back into operation, refill with fresh fuel (see page 22). 26 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 33
    Check cord connection. Replace defective cord set. Check electrical appliance/equipment for defects. Disconnect defective appliance/equipment from the generator. Have appliance serviced by qualified repair facility. HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators
  • Honeywell HW2000i | Owners Manual - Page 34
    THIS PAGE INTENTIONALLY LEFT BLANK 28 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 35
    10. HW1000i / HW2000i Inverter Generator Specifications HW2000i 21.3 / 541 20.0 / 508 11.4 / 289.6 58 / 26.3 2000 100 60 120 12-18 104q / 40q 14q / -10q 5000** OHV 4-cycle 125 1.5 / 5.7 0.48 / 450 0.024-0.028 / 0.6-0.7 HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators
  • Honeywell HW2000i | Owners Manual - Page 36
    #18 yellow / green white M step motor/ fuel control overload indicator light fuel economy switch output indicator light ground terminal HW1000i / HW2000i Inverter Generator Owner's Manual DC12V Outlet 5A front panel assembly on / off switch low oil indicator light S oil level N sensor
  • Honeywell HW2000i | Owners Manual - Page 37
    / HW2000i Inverter Generator Owner's Manual #16 black _ AC + AC primary DC breaker 10A DC winding #16 blue secondary DC12V Outlet front panel assembly inverter #14 black AC breaker 20A white M step motor/ fuel control fuel economy switch overload indicator light output indicator
  • Honeywell HW2000i | Owners Manual - Page 38
    THIS PAGE INTENTIONALLY LEFT BLANK 32 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 39
    LIMITED WARRANTY Honeywell Inverter Generator Effective November 1, 2008 LIMITED WARRANTY Northshore Power Systems, LLC, (NSP) will repair or replace, free of charge, to the original retail customer, in North America, any parts of the inverter generator found by NSP or an authorized service center
  • Honeywell HW2000i | Owners Manual - Page 40
    . You are responsible to bring your inverter generator to an authorized NSP Honeywell generator dealer for repairs as soon as a problem exists. Do not return your generator to place of purchase for service. For emissions warranty service, contact your nearest dealer; a listing is available at www
  • Honeywell HW2000i | Owners Manual - Page 41
    the Honeywell Generator Owner's Manual. Any replacement part that is equivalent in performance and durability may be used for maintenance or repairs. QUESTIONS If you have questions regarding your emissions warranty rights and responsibilities, you should contact the Warranty and Service department
  • Honeywell HW2000i | Owners Manual - Page 42
    THIS PAGE INTENTIONALLY LEFT BLANK 36 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 43
    Plug Servicing 25 Specifications 29 Stopping Generator 14 Storage Recommendations 26 T Transfer Switch for backup power 6 Troubleshooting 27 U Unpacking Guidelines 5 W Warranty emissions control 34 limited 33 Wattage, Typical Appliance 15 HW1000i / HW2000i Inverter Generator Owner's Manual www
  • Honeywell HW2000i | Owners Manual - Page 44
    THIS PAGE INTENTIONALLY LEFT BLANK 38 www.honeywellgenerators.com HW1000i / HW2000i Inverter Generator Owner's Manual
  • Honeywell HW2000i | Owners Manual - Page 45
    Screw, Top Maintenance Cover 101759A Spark Plug 101566A HW1000i/HW2000i Maintenance Parts List For part numbers of replacement product labels, see page 3. 101612A 101619A 101622A 101621A 101759A 101566A HW1000i / HW2000i Inverter Generator Owner's Manual www.honeywellgenerators.com 39
  • Honeywell HW2000i | Owners Manual - Page 46
    -1082 USA TEL 1-888-494-3571 www.honeywellgenerators.com P/N: 101435B January 2009 c 2009 Northshore Power Systems, LLC The Honeywell Trademark is used under license from Honeywell International Inc. Honeywell International Inc. makes no representation or warranties with respect to this product
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46

HW1000i
HW2000i
For product inquires or support, please visit www.honeywellgenerators.com or
call toll-free at 1-888-HWHELP1 (494-3571).
Owner’s Manual
Inverter Generator
Manual del Propietario
Si tiene preguntas acerca de los productos o requiere de asistencia, visite
www.honeywellgenerators.com o llame gratis al 1-888-HWHELP1 (494-3571).
Pour obtenir des renseignements sur les produits ou pour du soutien technique,
visitez notre site à l’adresse www.honeywellgenerators.com (en anglais seulement)
ou composez notre numéro sans frais 1-888-HWHELP1 (494-3571).
Guide D’Utilisation