Honeywell MK1650-62B14 Configuration Guide

Honeywell MK1650-62B14 - Metrologic IS1650 - Wired Stationary Barcode Scanner Manual

Honeywell MK1650-62B14 manual content summary:

  • Honeywell MK1650-62B14 | Configuration Guide - Page 1
    MetroSelect® Area Imaging Supplemental Configuration Guide
  • Honeywell MK1650-62B14 | Configuration Guide - Page 2
    Metrologic, MetroSelect, RangeGate, Genesis, CodeSelect, and Focus are trademarks or registered trademarks of Metrologic Instruments, Inc. or Honeywell such marks by Metrologic Instruments, Inc. or Honeywell International Inc. is under license. Other product names mentioned in this manual may be
  • Honeywell MK1650-62B14 | Configuration Guide - Page 3
    Contents Imager Operation Presentation and Trigger Modes In-Stand...1 Out-of-Stand 2 Out-of-Stand / In-Stand Mode Match 2 Pass-Through Settings (MS7580 Only 5 Omnidirectional and/or Linear Imager Modes 6 Aiming and Illumination 8 Data Output ...10 Character Suppression 11 Code Bytes 0 - 9 12
  • Honeywell MK1650-62B14 | Configuration Guide - Page 4
    PDF Options 32 RS232 Software Handshaking 33 Multifunctional USB/IBM Interface 33 Interfaces Additional Interfaces 35 MS7580 Genesis Specific 37 Enter/Exit Configuration Mode 39 Contact Information 41 iv
  • Honeywell MK1650-62B14 | Configuration Guide - Page 5
    multi-try trigger mode, the continuous trigger mode, and the single-trigger mode. These modes can be configured separately for in-stand and out-of-stand imager operation‡. In-Stand ‡ * Presentation Mode In-Stand Multi-Try Trigger Mode In-Stand ³ 420204 ³ 420224 Continuous Trigger Mode In-Stand
  • Honeywell MK1650-62B14 | Configuration Guide - Page 6
     Presentation Mode Out-of-Stand ³ 418304 * Multi-Try Trigger Mode Out-of-Stand ³ 418324 Continuous Trigger Mode Out-of-Stand ³ 418354 Single Trigger Mode Out-of-Stand ³ 418344 In-Stand/Out-of-Stand Mode Match Set In-Stand Mode to Match Out-of-Stand Mode ³ 4202154 * Factory default configuration
  • Honeywell MK1650-62B14 | Configuration Guide - Page 7
    is released. Presentation Mode 5 seconds After Button Release ³ 8238100 The imager reverts to presentation mode when 5 seconds after the button is released. * Factory default configuration. † The term trigger and button are synonymous.  This feature is only supported in the MS7580 Genesis™. 3
  • Honeywell MK1650-62B14 | Configuration Guide - Page 8
    * Enable Trigger Press Timeout In Presentation Mode ³ 124403 Disable Trigger Press Timeout In Presentation Mode ³ 124413 * Factory default configuration.  This feature is only supported in the Focus® product series (i.e., IS1650, MS1890, MS1633, and the MS1690). 4
  • Honeywell MK1650-62B14 | Configuration Guide - Page 9
    -Through Settings In Presentation Mode ³ 127005 Enable 100 milliseconds Pass-Through Timeout ³ 8439100 * Factory default configuration for the MS7580. † The term trigger and button are synonymous.  This feature is only supported in the MS7580 Genesis.  Contact a customer service representative
  • Honeywell MK1650-62B14 | Configuration Guide - Page 10
    † and presentation operations can be configured separately for omnidirectional and linear scan modes. • When a unit is configured to operate as an omnidirectional imager, all 1D and 2D bar codes are scanned omnidirectionally. The only exceptions are Code 128 scanner configuration labels, which
  • Honeywell MK1650-62B14 | Configuration Guide - Page 11
    1D Linear Only in Trigger Operations ³ 120212 Disable 1D Linear Only in Trigger Operations ³ 120202 Enable Linear Only in Presentation Operations ³ 120211 Disable Linear Only in Presentation Operations ³ 120201 Enable 1D Linear Only in Presentation Operations ³ 120210 Disable 1D Linear Only in
  • Honeywell MK1650-62B14 | Configuration Guide - Page 12
    presentation operations can be configured separately to use the imager's linear illumination as an aiming instrument. * Enable Aiming in Trigger Operations Disable Aiming in Trigger Operations ³ 124000 ³ 124010 * Enable Aiming in Presentation Operations ³ 124011 Disable Aiming in Presentation
  • Honeywell MK1650-62B14 | Configuration Guide - Page 13
    Illumination Group 1 ³ 124002 Disable Illumination Group 1 ³ 124012 * Enable Illumination Group 2 ³ 124003 Disable Illumination Group 2 ³ 124013 * Factory default configuration.  This feature is only supported in the Focus product series (i.e., IS1650, MS1890, MS1633, and the MS1690). 9
  • Honeywell MK1650-62B14 | Configuration Guide - Page 14
    Data Output * Enable Data Output ³ 121205 * Factory default configuration. Disable Data Output ³ 121215 10
  • Honeywell MK1650-62B14 | Configuration Guide - Page 15
    the Character 1 bar code (below left). 4. Scan the three code bytes that represent the character to be suppressed, on page 12. 5. Scan the Enter/Exit Configuration Mode bar code, on page 39. Enable the Suppression of 2 Characters * Disable the Suppression of 2 Characters ³ 115112 ³ 115102 To
  • Honeywell MK1650-62B14 | Configuration Guide - Page 16
    0 - 9 Notes: For additional information on Code Bytes, refer to the Code Bytes Usage section of the MetroSelect Configuration Guide (PN 00-02544). Code Byte 0 ³ 0 ³ 1 Code Byte 1 ³ 2 Code Byte 2 ³ 3 Code Byte 3 ³ 4 Code Byte 4 ³ 5 Code Byte 5 ³ 6 Code Byte 6 ³ 7 Code Byte
  • Honeywell MK1650-62B14 | Configuration Guide - Page 17
    pulled. LED Options * Normal Blue LED Intensity ³ 143100 Low Blue LED Intensity ³ 143110 * Normal White LED Intensity Low White LED Intensity ³ 143102 ³ 143112 * Factory default configuration.  This feature is only supported in the MS7580 Genesis. 13
  • Honeywell MK1650-62B14 | Configuration Guide - Page 18
    14
  • Honeywell MK1650-62B14 | Configuration Guide - Page 19
    Imager Operation - MS1633 Power Save Modes†† Enable Trigger Power-Save * Disable Trigger Power-Save ³ been activated 5 times without a successful decode. Disable IR Power-Save ³ 125304 * Factory default configuration. †† These features are not for use with the MS1690, MS1890, or the IS1650. 15
  • Honeywell MK1650-62B14 | Configuration Guide - Page 20
    RangeGate® Mode†† Enable RangeGate Disable RangeGate ³ 123707 When enabled, the MS1633 will store scanned bar codes into non-volatile memory if the wireless connection has been interrupted. ³ 123717 Note: RangeGate and Inventory Mode are mutually exclusive. If both are enabled, Inventory Mode
  • Honeywell MK1650-62B14 | Configuration Guide - Page 21
    Firmware Version and Address†† Transmit the Firmware Version of the Imager with Bluetooth® Wireless Technology ³ 998044 Transmit the Address of the Imager with Bluetooth Wireless Technology ³ 998045 †† These features are not for use with the MS1690, MS1890 or the IS1650. 17
  • Honeywell MK1650-62B14 | Configuration Guide - Page 22
    bar code. When an item's bar code is scanned, the MS1633 automatically stores the bar code data in its non-volatile memory with a quantity field set to 1. The quantity field can then be modified using the quantity bar codes on page 20. The bar code data is not automatically transmitted to
  • Honeywell MK1650-62B14 | Configuration Guide - Page 23
    will be moved to the left to accommodate the new digit. For example, if the Quantity 5 bar code is scanned after the quantity has been set to 1234 then the 1 will be dropped and the quantity will become 2345. Examples To add a quantity of 5 1. Scan the item's bar code 2. Scan the
  • Honeywell MK1650-62B14 | Configuration Guide - Page 24
    Quantity Codes†† Quantity 0 ³ Q0 Quantity 5 ³ Q5 Quantity 1 ³ Q1 Quantity 6 ³ Q6 Quantity 2 ³ Q2 Quantity 7 ³ Q7 Quantity 3 ³ Q3 Quantity 8 ³ Q8 Quantity 4 Quantity 9 ³ Q4 ³ Q9 †† This feature is not for use with the MS1690, MS1890, or the IS1650. 20
  • Honeywell MK1650-62B14 | Configuration Guide - Page 25
    Transmit Entry Counter†† ³ 123914 Optional field transmitted with the bar code data that is a count of the number of transmissions used to transmit the entire buffer. Transmit Number of Records†† ³ 998051 Will transmit the number of records and the number of bar codes currently stored as a 5-digit
  • Honeywell MK1650-62B14 | Configuration Guide - Page 26
    Enable Inventory Beep†† ³ 123912 When enabled MS1633 will beep after transmitting each inventory record. * Disable Inventory Beep ³ 123902 Delete Last Record†† ³ 998063 When scanned, this bar code will delete the last bar code stored. Clear Inventory Records†† ³ 998049 When scanned, this bar code
  • Honeywell MK1650-62B14 | Configuration Guide - Page 27
    ³ 200522 ³ 200512 Enable Normal and Inverse Color Data Matrix Decoding ³ 200532 * Disable Data Matrix Decoder ³ 200502 Enable Rectangular Data Matrix Symbol Decoding ³ 100511 * Factory default configuration. * Disable Rectangular Data Matrix Symbol Decoding ³ 100501 23
  • Honeywell MK1650-62B14 | Configuration Guide - Page 28
    decoding† of Data Matrix symbols when the upper tiles in the symbol are shifted in the symbol relative to the bottom tiles. ³ 125405 * Factory default configuration † Enabling these options will increase decoding time for all bar codes. 24
  • Honeywell MK1650-62B14 | Configuration Guide - Page 29
    scan the Enable Data Matrix Normal Size bar code above. Enable Data Matrix, Small Size† Enable Data Matrix Very Small Size† ³ 325412 ³ 325422 * Factory default configuration. † Enabling these options will increase decoding time for all bar codes. 25
  • Honeywell MK1650-62B14 | Configuration Guide - Page 30
    QR Code Enable Normal Video QR Code ³ 200612 Enable Inverse Video QR Code ³ 200622 Enable Normal and Inverse QR Code ³ 200632 * Disable QR Code ³ 200602 MaxiCode Enable MaxiCode ³ 100614 * Factory default configuration. 26 * Disable MaxiCode ³ 100604
  • Honeywell MK1650-62B14 | Configuration Guide - Page 31
    Aztec Enable Normal Video Aztec Decoding ³ 100610 * Disable Normal Video Aztec Decoding ³ 100600 Enable Inverse Video Aztec Decoding ³ 100611 * Factory default configuration * Disable Inverse Video Aztec Decoding ³ 100601 27
  • Honeywell MK1650-62B14 | Configuration Guide - Page 32
    a structured append header will be stored in the imager's memory buffer. The imager will transmit the concatenated message once every component of CodeSelect feature will not work. The CodeSelect timeout setting determines how much time will be allowed between Factory default configuration. 28
  • Honeywell MK1650-62B14 | Configuration Guide - Page 33
    Postal Enable Australia Post ³ 126217 * Disable Australia Post ³ 126207 Enable Japan Post ³ 126216 * Disable Japan Post ³ 126206 Enable KIX Code ³ 126215 * Factory default configuration. * Disable KIX Code ³ 126205 29
  • Honeywell MK1650-62B14 | Configuration Guide - Page 34
    Enable PLANET Code ³ 126214 * Disable PLANET Code ³ 126204 Enable POSTNET Code ³ 126213 * Disable POSTNET Post ³ 126203 Enable B & B' Fielded POSTNET ³ 126212 * Factory default configuration 30 * Disable B & B' Fielded POSTNET ³ 126202
  • Honeywell MK1650-62B14 | Configuration Guide - Page 35
    Enable UPU Decoding ³ 126211 * Disable UPU Decoding ³ 126201 Enable Royal Mail 4 Code ³ 126210 * Disable Royal Mail 4 Code ³ 126200 Enable Zero-FCC Australia Post ³ 126412 * Factory default configuration. * Disable Zero-FCC Australia Post ³ 126402 31
  • Honeywell MK1650-62B14 | Configuration Guide - Page 36
    Codablock Options Enable Codablock A ³ 126410 Enable Codablock F ³ 126411 PDF Options Enable Transmit \ as \ ³ 115113 * Enable Transmit \ as \\ ³ 115103 * Factory default configuration. 32 * Disable Codablock A ³ 126400 * Disable Codablock F ³ 126401
  • Honeywell MK1650-62B14 | Configuration Guide - Page 37
    RS232 Software Handshaking Enable ]V Handshaking ³ 125210 An "]V" response from the host indicates reception of imager data. Disable ]V Handshaking ³ 125200 Multifunctional USB/IBM® Interface† Dual Interface Defaults† ³ 999923 † This feature is not for use with the MS1633. 33
  • Honeywell MK1650-62B14 | Configuration Guide - Page 38
    34
  • Honeywell MK1650-62B14 | Configuration Guide - Page 39
    Enable Beeper ON/OFF Commands ³ 125211 Enables beeper on/off commands with internal USB and IBM interfaces. 3rd Generation IBM 46xx Defaults ³ 999952 First, scan the bar code. Then, scan the IBM Reserve code #2. * Factory Default Configuration † These features are not for use with the MS1633. 35
  • Honeywell MK1650-62B14 | Configuration Guide - Page 40
    Note: Feature is for PDF codes only. * Send 00 for Last Block Label Identifier USB ³ 116310 Note: Feature is for PDF codes only. Full Speed USB Keyboard Interface Enable Full Speed USB Keyboard Interface Defaults ³ 999940 * Factory Default Configuration † These features are not for use with the
  • Honeywell MK1650-62B14 | Configuration Guide - Page 41
    Configuration Settings ³ 998071 Load USB Configuration Settings ³ 998072 Load Keyboard Wedge Configuration Settings ³ 998073 Load RS485 Configuration Settings ³ 998074 Recall Configuration for Currently Connected Interface ³ 998080  This feature is only supported in the MS7580 Genesis
  • Honeywell MK1650-62B14 | Configuration Guide - Page 42
     ³ 998075 Apply Settings to RS232 Interface ³ 998076 Apply Settings to the Current Interface ³ 998081 Apply Settings to USB Interface ³ 998077 Apply Settings to Keyboard Wedge ³ 998078 Apply Settings to RS485 Interface ³ 998079  This feature is only supported in the MS7580 Genesis. 38
  • Honeywell MK1650-62B14 | Configuration Guide - Page 43
    Enter/Exit Configuration Mode Enter Exit Configuration Mode ³ 999999 39
  • Honeywell MK1650-62B14 | Configuration Guide - Page 44
    40
  • Honeywell MK1650-62B14 | Configuration Guide - Page 45
    .com Mexico Tel: 55.5365.6247 Fax: 55.5362.2544 Email: [email protected] North America Tel: 856.537.6400 866.460.8033 (Customer Service) 888.633.3762 (Technical Support) Fax: 856.537.6474 Email: [email protected] South America (Outside Brazil) Tel: 55.11.5182.7273 Fax: 55.11.5182.7198
  • Honeywell MK1650-62B14 | Configuration Guide - Page 46
    Fax: 852-2511-3557 India India Sales Office Tel: +91 80 4125 6718 Fax: +91 80 4125 6719 Email: [email protected] Japan Tel: 81-3-3839-8511 Fax: 81-3-3839-8519 Email: [email protected] Korea Korea Sales Office Tel: (82) 2-6205-5379 Fax: (82)-2-3444-3980 Email: info@kr
  • Honeywell MK1650-62B14 | Configuration Guide - Page 47
  • Honeywell MK1650-62B14 | Configuration Guide - Page 48
    Honeywell Scanning & Mobility 90 Coles Road Blackwood, NJ 08012-4683 00-05252 Rev B June 2009
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48

MetroSelect
®
Area Imaging Supplemental
Configuration Guide