- Honeywell MS9535-5 | User Manual - Page 1
METROLOGIC INSTRUMENTS, INC. MS9535 VoyagerBT ® Series Single-Line Hand Held Laser Scanner Installation and User's Guide - Honeywell MS9535-5 | User Manual - Page 2
consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976. Trademarks Metrologic is a registered trademark of Metrologic Instruments, Inc. Products identified in this document are hereby acknowledged as trademarks, registered or otherwise, of - Honeywell MS9535-5 | User Manual - Page 3
Supply 13 Full Speed USB (Powered by the Host Device 14 Establishing Bluetooth Communication Between the Scanner and the Cradle 15 Dynamic Pair Function 15 When the MS9535 Acts as a Client to Other Bluetooth Devices 16 When the MS9535 Acts as a Server to Other Bluetooth Devices 17 The MI9535 - Honeywell MS9535-5 | User Manual - Page 4
Depth of Field by Bar Code Element Width 26 IR Activation Range 27 Cable Removal 28 Cradle Wall Mount 28 Troubleshooting Guide 29 Design Specifications 33 Default Settings - Communication Parameters 35 Upgrading the Flash ROM Firmware 40 Configuration Modes 40 Cradle and Cable Terminations - Honeywell MS9535-5 | User Manual - Page 5
and cradle, future bar code scans will be transmitted from the scanner to the cradle and from the cradle to the host. VoyagerBT scanners can also optionally communicate to other Bluetooth enabled devices. The cradle of the VoyagerBT also works as a battery charger for the scanner. When resting in - Honeywell MS9535-5 | User Manual - Page 6
-5M 70-79004x 00-02544x 70-73524 BASIC KIT Description VoyagerBT Scanner or VoyagerBT Scanner with Memory MS9535 VoyagerBT Wireless Hand Held Laser Scanner Installation and User's Guide* MetroSelect Single-Line Configuration Guide* Wrist Strap Part # MI9535-514 MI9535-541 MI9535-547 MI9535-538 - Honeywell MS9535-5 | User Manual - Page 7
54-54073x Full Speed USB Cable, with Power From Register 54-54200x-N Full Speed USB Cable, with External Power Supply Other items may be ordered for the specific protocol being used. To order additional items, contact the dealer, distributor or call Metrologic's Customer Service Department at - Honeywell MS9535-5 | User Manual - Page 8
(see pages 23) 3 Amber LED (see pages 23) 4 CodeGate Button 5 Output Window, Laser Aperture 6 Speaker (see page 22) 7 Wrist Strap Charging Contacts /Rubber Feet 8 Do not short circuit the charging contacts on the scanner! A short circuit can occur when a metallic object such as a coin, clip - Honeywell MS9535-5 | User Manual - Page 9
. 5 Bluetooth Address Bar Code (see page 23) 6 Wall Mount Hook - Scanner Support 7 Blue LED (see page 23) Page Button 8 When the page button on the cradle is pressed, the scanner will begin to beep and the blue and amber LEDs will alternately flash. To discontinue paging the scanner, press - Honeywell MS9535-5 | User Manual - Page 10
with applicable standards, all circuits connected to the scanner must meet the requirements for SELV power source should meet applicable performance requirements for a limited power source. Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. The output window will - Honeywell MS9535-5 | User Manual - Page 11
Plug the power supply into the AC outlet. The blue LED on the rear of the cradle will stay on. Figure 4. RS232 and Light Pen 6. Turn on the host device. 7. Establish communication between the scanner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication between - Honeywell MS9535-5 | User Manual - Page 12
6. Plug the power supply into the AC outlet. The blue LED on the rear of the cradle will stay on. 7. Turn on the host device. 8. Establish communication between the scanner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication between the scanner and cradle. The - Honeywell MS9535-5 | User Manual - Page 13
the power supply into the AC outlet. The blue LED on the rear of the cradle will stay on. Figure 6. Stand Alone Keyboard 6. Turn on the host device. 7. Establish communication between the scanner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication between - Honeywell MS9535-5 | User Manual - Page 14
Plug the power supply into the AC outlet. The blue LED on the rear of the cradle will stay on. Figure 7. IBM 6. Turn on the host device. 7. Establish communication between the scanner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication between the scanner and - Honeywell MS9535-5 | User Manual - Page 15
Important Notes for VoyagerBT USB Interface Scanners In order for the VoyagerBT to scan and charge properly both the power supply and the USB communication cable must be attached before the host device is turned on. When the scanner is in the cradle and the power supply is connected to the cradle - Honeywell MS9535-5 | User Manual - Page 16
Mode enabled. Scan the following bar code to configure the MI9535-538 for USB Serial Emulation Mode. ³ 316460 The scanner must be charged for a minimum of 3 hours before the scanner can be placed in full operation for the first time. After the initial preparation charge of 3 hrs, the battery will - Honeywell MS9535-5 | User Manual - Page 17
9. Full Speed USB 5. Plug the power supply into the AC outlet. The blue LED on the rear of the cradle will stay on. 6. Turn on the host device. 7. Establish communication between the scanner and cradle. See page 15 for complete instructions on Establishing Bluetooth Communication between the scanner - Honeywell MS9535-5 | User Manual - Page 18
on Establishing Bluetooth Communication between the scanner and cradle. Figure 10. Full Speed USB The scanner must be charged for a minimum of 3 hours before the scanner can be placed in full operation for the first time. After the initial preparation charge of 3 hrs, the battery will only require - Honeywell MS9535-5 | User Manual - Page 19
illuminated. Figure 11. It is important to note that the MS9535 will only communicate with a cradle whose Bluetooth address was the last address scanned. Once a cradle is paired with the MS9535, another scanner can not be paired with that cradle until the original connection is broken. The - Honeywell MS9535-5 | User Manual - Page 20
a Client to Other Bluetooth Devices The MS9535 scanner can also link to other Bluetooth compatible devices such as a desktop computer, laptop computer, or printer. As a default, the MS9535 will act as the client to another Bluetooth device. The devices' Bluetooth address must be scanned to establish - Honeywell MS9535-5 | User Manual - Page 21
COMMUNICATION When the MS9535 Acts as a Server to Other Bluetooth Devices Scan the Provide Service bar code below to enable the MS9535 to act as a server and be detected by another Bluetooth device. This will allow other Bluetooth devices to send inquiries to the scanner and attempt communication - Honeywell MS9535-5 | User Manual - Page 22
or full sleep mode to save power. z To enable normal sleep mode, scan the configuration bar codes in the MetroSelect Single-Line Configuration Guide (MLPN 00-02544x). z To enable full sleep mode, after the laser shuts off, depress the CodeGate button and hold for 3 seconds, the scanner will give - Honeywell MS9535-5 | User Manual - Page 23
. • Do not disassemble or modify batteries. Caution: Danger of explosion if batteries are incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacture. Dispose of used batteries according to the recycle program for batteries as directed by the governing agency - Honeywell MS9535-5 | User Manual - Page 24
charger, the cradle recharges the scanner whenever it is set into place. Even if the scanner's battery is full, the cradle will continue to supply power to the scanner. To order a cradle with charging capabilities only (MLPN 46-46772), contact a Metrologic Customer service representative at 1-800-ID - Honeywell MS9535-5 | User Manual - Page 25
associated with this mode, please consult the MetroSelect Single-Line Configuration Guide (MLPN 00-02544x). Inventory Mode (Specific to MS9535-5M) For light warehousing applications, Metrologic offers the MS9535-5M VoyagerBT with extended memory and a unique feature called Inventory Mode. This mode - Honeywell MS9535-5 | User Manual - Page 26
code, the scanner's white LED will flash and the unit will beep once. When the CodeGate button is pressed for 3 seconds, the scanner will indicate it has entered full sleep mode with a extended beep. Two Beeps When the scanner has a low battery voltage, it will emit two beeps after a successful scan - Honeywell MS9535-5 | User Manual - Page 27
status of the scanner and the current scan. Blue, White & Amber LEDs are off The scanner is not receiving power from the cradle or the scanner's internal battery. The scanner is in full sleep mode. Press the CodeGate button to wake the scanner from full sleep mode. The blue LED will start to flash - Honeywell MS9535-5 | User Manual - Page 28
of Blue and White This indicates the scanner is in configuration mode. Two razzberry tones indicate that an invalid bar code has been scanned while in this mode. If the scanner is in RangeGate active mode, this indicates the SRAM of the scanner becomes full. If the scanner needs to have a Flash ROM - Honeywell MS9535-5 | User Manual - Page 29
the scanner configuration has failed. If the scanner does not respond after reconfiguring, return the scanner for repair to an authorized service center. Two Razzberry Tones with Steady White When the scanner scans a bar code without establishing Bluetooth communication first, the scanner will emit - Honeywell MS9535-5 | User Manual - Page 30
SCANNER OPERATION Depth of Field by Bar Code Element Width* Minimum Bar Code Element Width A B C D E F G H J K mm .13 .15 - - .19 - .25 .33 .53 - mils 5.2 5.7 - - 7.5 - 10 13 21 - Figure 12. Depth of Field by Bar Code Element Width * All specifications are subject to - Honeywell MS9535-5 | User Manual - Page 31
SCANNER OPERATION IR Activation Range Figure 13. IR Activation Range * All specifications are subject to change without notice. 27 - Honeywell MS9535-5 | User Manual - Page 32
scanner, Metrologic recommends that the power on the host device is off and the power supply Release 4. You will hear a Metrologic provides two #7 wood screws for securing the cradle to the wall. z Figure 15 provides the pilot hole dimensions for securing the cradle base. z Install the cradle base - Honeywell MS9535-5 | User Manual - Page 33
has no LEDs, beeper or laser when out of the cradle. The scanner's internal battery is not supplying power to scanner. Place the scanner into the cradle to recharge the battery. The scanner locks up after the first scan. The white LED stays on and the unit razzes twice. Communication has not - Honeywell MS9535-5 | User Manual - Page 34
TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The scanner emits 3 beeps on power up. A non-volatile RAM failure may have occurred. Contact a Metrologic customer service representative, if the unit will not hold the configuration. The scanner emits a continuous razz tone on power - up - Honeywell MS9535-5 | User Manual - Page 35
TROUBLESHOOTING GUIDE Symptoms Possible Causes Solution The scanner scans a bar code, but locks up after the first scan. The white LED stays on. The scanner is configured to support some form of host handshaking but is not receiving the signal. If the scanner is setup to support ACK/NAK, RTS/ - Honeywell MS9535-5 | User Manual - Page 36
TROUBLESHOOTING GUIDE Symptoms The scanner scans the bar code but there is no data. The scanner scans but the data is not correct. The scanner is transmitting each character twice. Possible Causes The scanner configuration is not correctly. Solution Make sure the scanner is configured for the - Honeywell MS9535-5 | User Manual - Page 37
Read: (Maximum number will vary based on symbology & density) Roll, Pitch, Yaw: 42°, 68°, 52° Beeper Operation: 7 tones or no beep Blue laser on, ready to scan Scanner LED Indicators: White good read Amber Cradle LED indicators: Blue battery full connection status Mechanical Length: 198 - Honeywell MS9535-5 | User Manual - Page 38
± 0.25V 5.0VDC ± 0.25V Cradle Power: 0.6 W Scanner Power: Scanner Current: Operating Sleep Operating Sleep 1.15 W 150 mW 230 mA@5VDC 30mA@ 5VDC Cradle Current: Cradle: 120 mA @ 5VDC DC Transformers: Class II; 5.0V @ 2A Battery Capacity /Recharge Time: 12000 scans per charge / recharge time - Honeywell MS9535-5 | User Manual - Page 39
of the scanner and cradle can be "configured" - that is, enabled or disabled. The scanner and cradle are shipped from the factory configured to a -of Stand UPC/EAN Code 128 Code 93 Codabar Interleaved 2 of 5 (ITF) MOD 10 check on ITF Code 11 Code 39 Full ASCII Code 39 Default * * * * RS232 - Honeywell MS9535-5 | User Manual - Page 40
9 9 9 Paraf Support ITF 9 9 9 9 9 ITF Symbol Lengths Variable 9 9 9 9 9 Minimum Symbol Length 3 9 9 9 9 9 Symbol Length Lock None 9 9 9 9 9 Bars High as Code 39 * 9 9 Spaces High as Code 39 9 9 Bars High as Scanned 9 9 Spaces High as Scanned 9 9 Poll light - Honeywell MS9535-5 | User Manual - Page 41
* Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check digit on Code 39 Transit Mod 10/ITF 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 9 Transmit MSI-Plessy Parity Baud Rate 9 Scanner: Space 9 Cradle: None 9600 - Honeywell MS9535-5 | User Manual - Page 42
DEFAULT SETTINGS - COMMUNICATION PARAMETERS Parameter UPC Prefix UPC Suffix Carriage Return Line Feed-Disabled by default in KBW Tab Prefix Tab Suffix "DE" Disable Command "FL" Laser Enable Command DTR Handshaking support RTS/CTS Handshaking Character Message RTS/CTS XON/XOFF Handshaking ACK/NAK - Honeywell MS9535-5 | User Manual - Page 43
for Individual Code types 9 9 9 Editing 9 9 9 9 9 Inter Scan-Code delay Configurable 800 µsec 9 (100 µsec steps) Function/control Key Support Minimum Element width Configurable in 5.6 µsec steps 1 msec 9 9 RangeGate Enabled 9 9 9 9 9 Authenticate 9 9 9 9 9 MTLG - Honeywell MS9535-5 | User Manual - Page 44
to this guide for instructions. The MetroSelect Single-Line Configuration Guide can be downloaded for FREE from Metrologic's website (www.metrologic.com). MetroSet2 This user-friendly Windows-based configuration program allows you to simply 'point-and-click' at the desired scanner options. This - Honeywell MS9535-5 | User Manual - Page 45
and power ports located on the bottom of each MI9535-5xx cradle. The number of ports and type of connection varies by cradle model and the interface required. The following charts provide the pinout information for the different cradle models and interfaces available. Figure 17. MI9535-514 Full - Honeywell MS9535-5 | User Manual - Page 46
CRADLE AND CABLE TERMINATIONS Cradle Pinout Connections Figure 18. Cradle MI9535-538 MI9535-538 Low Speed USB Port 10-Pin, RJ45 Pin Function 1 10 Shield Ground USB Type B Pin Function 1 VCC 2 D- 3 D+ 4 Ground Figure 19. Cradle MI9535D540 MI9535D540 Full Speed USB 10-Pin, RJ45 - Honeywell MS9535-5 | User Manual - Page 47
CRADLE AND CABLE TERMINATIONS Cradle Pinout Connections Figure 20. Cradle MI9535C540 MI9535C540 Full Speed USB 10-Pin, RJ45 Pin Function 1 Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 RTS Output 5 CTS Input 6 D+ 7 USB +5V 8 D- 9 Reserved 10 Shield Ground 43 - Honeywell MS9535-5 | User Manual - Page 48
Cable Connector Configurations (Host End) RS232/Light Pen Cable MLPN 54-54000x-N Pin Function 1 Shield Ground 2 RS232 Transmit Output 3 RS232 Receive Input 4 DTR Input/Light Pen Source 5 Power/Signal Ground 6 Light Pen Data 7 CTS Input 8 RTS Output 9 +5VDC 9-Pin D-Type Connector USB Cable MLPN - Honeywell MS9535-5 | User Manual - Page 49
CABLE TERMINATIONS Cable Connector Configurations Full Speed USB Cable with power from Register MLPN 54-54073x Pin Function 1 +5VDC 2 D- 3 D+ 4 Ground 5 Ground 6 +12V 7 +12V 8 Ground USB A Plus Power Type Connector Full Speed USB Cable with external Power Supply MLPN 54-54200x-N Pin - Honeywell MS9535-5 | User Manual - Page 50
-3 Pin Function 1 Keyboard Clock 2 Keyboard Data 3 No Connect 4 Power Ground 5 +5 Volts DC Pin Function 1 PC Data 2 No Connect 3 Power Ground 4 +5 Volts DC 5 PC Clock 6 No Connect 5-Pin DIN, Female 6-Pin DIN, Male Metrologic will supply an adapter cable with a 5-pin DIN male connector - Honeywell MS9535-5 | User Manual - Page 51
to service the laser scanner. Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in Manuale può provocare delle esposizioni a raggi laser rischiose. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser - Honeywell MS9535-5 | User Manual - Page 52
instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case the user will may cause undesired operation. The radiated output power of this intentional wireless radio is far below - Honeywell MS9535-5 | User Manual - Page 53
radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to - Honeywell MS9535-5 | User Manual - Page 54
its Blackwood, New Jersey, U.S.A facility and its Suzhou, China facility. The MS9535 VoyagerBT scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9535 VoyagerBT scanners are free of all defects in material, workmanship and design - Honeywell MS9535-5 | User Manual - Page 55
use of the specific equipment, circuits, and devices represented by or contained in the METROLOGIC products that are physically transferred to the user, and only to the extent of METROLOGIC's license rights and subject to any conditions, covenants and restrictions therein. Other worldwide patents - Honeywell MS9535-5 | User Manual - Page 56
power accessories 2, 3 address bar code......... 5, 15, 16, 17 amber LED see indicator authenticate 39 B battery 18, 19, 20, 33, 34 beep see indicator blue LED see indicator Bluetooth configuration 22 connector 41-46 cradle 2, 5, 15, 17-21, 40 current 34 customer service 50 D DC see power - Honeywell MS9535-5 | User Manual - Page 57
INDEX pin-hole 28 pinout 41-46 power 3, 18, 19, 33, 34 R range 21, 26, 27, 34, 35 Alone Keyboard see interface suppliment 38 symbol 36 T tone see indicator transformer see power troubleshooting 29-32 U upgrade 40 USB see interface V ventilation 18, 34, 36 voltage 34 W warranty 50 - Honeywell MS9535-5 | User Manual - Page 58
54 - Honeywell MS9535-5 | User Manual - Page 59
- Honeywell MS9535-5 | User Manual - Page 60