Honeywell MS9535-5 User Manual - Page 38

Electrical, Environmental

Page 38 highlights

DESIGN SPECIFICATIONS Scanner and Cradle Specifications Electrical Scanner: Input Voltage: Cradle: 5.2VDC ± 0.25V 5.0VDC ± 0.25V Cradle Power: 0.6 W Scanner Power: Scanner Current: Operating Sleep Operating Sleep 1.15 W 150 mW 230 mA@5VDC 30mA@ 5VDC Cradle Current: Cradle: 120 mA @ 5VDC DC Transformers: Class II; 5.0V @ 2A Battery Capacity /Recharge Time: 12000 scans per charge / recharge time = 2.5 hours Radio Range: 10 m (33 ft) For regulatory compliance information, see pages 47 - 49. Environmental Temperature: Operating = 0°C to 40° (32° to 104°F) Storage = -20°C to 50°C (-4°F to 122°F) Humidity: 5% to 95% relative humidity, non-condensing Light Levels: Up to 4842 Lux (450 footcandles) Shock: Designed to withstand 1.5 m (5') drops Contaminants: Sealed to resist airborne particulate contaminants Ventilation: None required * All specifications are subject to change without notice. 34

  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • 14
  • 15
  • 16
  • 17
  • 18
  • 19
  • 20
  • 21
  • 22
  • 23
  • 24
  • 25
  • 26
  • 27
  • 28
  • 29
  • 30
  • 31
  • 32
  • 33
  • 34
  • 35
  • 36
  • 37
  • 38
  • 39
  • 40
  • 41
  • 42
  • 43
  • 44
  • 45
  • 46
  • 47
  • 48
  • 49
  • 50
  • 51
  • 52
  • 53
  • 54
  • 55
  • 56
  • 57
  • 58
  • 59
  • 60

34
D
ESIGN
S
PECIFICATIONS
Scanner and Cradle Specifications
Electrical
Scanner:
5.2VDC
± 0.25V
Input Voltage:
Cradle:
5.0VDC
± 0.25V
Cradle Power:
0.6 W
Operating
1.15 W
Scanner Power:
Sleep
150 mW
Operating
230 mA@5VDC
Scanner Current:
Sleep
30mA@ 5VDC
Cradle Current:
Cradle: 120 mA @ 5VDC
DC Transformers:
Class II; 5.0V @ 2A
Battery Capacity
/Recharge Time:
12000 scans per charge / recharge time = 2.5 hours
Radio Range:
10 m (33 ft)
For regulatory compliance information, see pages 47 - 49.
Environmental
Operating = 0°C to 40° (32° to 104°F)
Temperature:
Storage = -20°C to 50°C (-4°F to 122°F)
Humidity:
5% to 95% relative humidity, non-condensing
Light Levels:
Up to 4842 Lux (450 footcandles)
Shock:
Designed to withstand 1.5 m (5’) drops
Contaminants:
Sealed to resist airborne particulate contaminants
Ventilation:
None required
* All specifications are subject to change without notice.